Attachment C-Equipment Listing.xlsx
XLSX spreadsheet 15 KB Posted
- Attached to
- J065--Hemodialysis Equipment Maintenance
- Solicitation number
- 36C25226Q0096
About this file
The file is an Equipment Listing attachment (Attachment C) for a VA hemodialysis water filtration equipment maintenance contract with Evoqua Water Technologies, LLC at the Edward Hines Jr. VA Hospital. The detailed spreadsheet outlines comprehensive maintenance requirements for multiple water systems, including a CWP 102H System, MHX Portables, and various filtration components, with specific service frequencies ranging from monthly to annually. The maintenance schedule covers tasks such as system performance reviews, tank head rebuilding, carbon filter rebed, membrane cleaning, pre and post filter inspections, water testing (including LAL and bacteria tests), chemical disinfection, and unscheduled/emergency work.
The related federal contract opportunity is a sole source procurement under VA Great Lakes Acquisition Center (GLAC) with NAICS Code 811210, intended to be a firm fixed-price contract for a base year and four one-year option periods. The solicitation (36C25226Q0096) requires potential alternative vendors to submit capability statements by 10:00 AM on 11/24/2025, demonstrating their ability to meet the water filtration system maintenance requirements. The contract will cover all labor, transportation, parts, and expertise for preventive maintenance, emergency repairs, and recurring water testing on the filtration systems at the Hines, IL VA Hospital location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25226Q0096.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Covered Equipment | |||||||||||||||||
| Vendor functional Code | Serial Numbers | Equipment Description | EE # | ||||||||||||||
| FLOC's: 0022431842, 0022431843 | 1369829, 1371816 | CWP 102H System | NA, NA | ||||||||||||||
| FLOCS's: 0022431834, 0022431835, | 1381384, 1381385, 1381386, | MHX Portables (7) | 114977, 114975,114976 | ||||||||||||||
| 0022431836, 0022431837, 0022431838, | 1381387, 1383780, 1383783, | 114974, 116275, 116274 | |||||||||||||||
| 0022431839, 0022431840 | 1383876 | 116276 | |||||||||||||||
| Schedule of Services | |||||||||||||||||
| 2 | System Performance Review (W3TSP7312) | SI0002 | Monthly | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| 4 | Rebuild Tank Head (2850,NHWBP) (W3TSP7034:includes: W2T132346-1, W2T913251-1, Labor 1 HR) | SRV1001 | Annually | 4 | |||||||||||||
| 4 | Carbon Filter Rebed, 7 cu.ft. (W3T572487:includes:W3T572487-7, W2T911945-4, W3T577797-1, W2T913121-1, W2T913131-1, LABOR-3 HR) | SRV1010 | Annually | 4 | |||||||||||||
| 2 | Clean Membranes (W3TSP4638:includes: W2T934418 -.25, W2T912365-.25, LABOR (4 HR)) | 4000-0215 | Semi-Annually | 2 | 2 | ||||||||||||
| 2 | CWP Annual Preventative Maintenance Kit (W3T577722-every 12 months, W3T577723-every 24 months, W3T577669-every 48 months) | 4000-0092 | Annually | 2 | |||||||||||||
| 2 | Inspect & Replace RO Pre Filter (W3TSP4603) | SI5000 | Monthly | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| 2 | FILTER,DEPTH,SW,PP,1M,4-1/2"X20",DOE (W2T913146) | ME42007 | Monthly | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| 2 | Inspect & Replace Post Filter (W3TSP4602) | SI5120 | Annually | 2 | |||||||||||||
| 2 | Filter, RenaPure, 20", 222, FLAT (W3T590100) | W3T590100 | Annually | 2 | |||||||||||||
| 4 | Rental DI Tanks, 14x47, 3.6 cu.ft. (W5TDIMB10360FSQR) | 920-01-047 | Semi-Annually | 4 | 4 | ||||||||||||
| 1 | AAMI (W3TSP7119)Test City Water (Customer to Pull) | AAMI TEST | Annually | 1 | |||||||||||||
| 2 | AAMI (W3TSP7119) RO Product (Customer to Pull) | AAMI TEST | Semi-Annually | 2 | 2 | ||||||||||||
| 90 | LAL Water Test (W3TSP7171) (Customer to Pull) | LAL TEST | Monthly | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | ||
| 90 | Bacteria Water Test (W3TSP7170) (Customer to Pull) | BACTERIA TEST | Monthly | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | ||
| 6 | LAL Water Test (W3TSP7171) (Evoqua to Pull) | LAL TEST | Monthly | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | ||
| 6 | Bacteria Water Test (W3TSP7170) (Evoqua to Pull) | BACTERIA TEST | Monthly | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | ||
| 1 | LEAVE GALLON MINNCARE HD AS NEEDED (W2T912234) | 3029764 | Monthly | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
| 1 | TEST,STRIP,MINNCARE HD,RESID,100 (W2T912238 ) | 3029795 | Quarterly | 1 | 1 | 1 | 1 | ||||||||||
| 2 | CWP Extended Coverage (W3TSP3048) | 4000-1092 | Annually | 2 | |||||||||||||
| 1 | Annual Cleaning of Temperature Blending Valve (W3TSP4539 ) | 4000-1101 | Annually | 1 | |||||||||||||
| 1 | Annual Calibration of Booster Pump (W3TSP7356) | 4000-1102 | Annually | 1 | |||||||||||||
| 7 | Portable Performance Review (W3TSP7037) | 4000-0089 | Monthly | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
| 7 | Portable Chemical Disinfection (Multiple) (W3TSP4707:includes: W2T912235-.1, W2T912238-.1, W2T912239-.25, LABOR-1 HR) | 4000-0083 | Quarterly | 7 | 7 | 7 | 7 | ||||||||||
| 7 | Portable Cleaning (High and Low) (W3TSP4638: includes: W2T934418-.1, W2T912365-.1, Labor-2hr) | 4000-0060 | Quarterly | 7 | 7 | 7 | 7 | ||||||||||
| 7 | Inspect & Replace RO Pre Filter (W3TSP4603) | SI5000 | Monthly | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
| 7 | FILTER,5M,9-7/8IN (W2T913469) | ME40696 | Monthly | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
| 7 | Inspect & Replace 1 Carbon Block PTG-520® Filter (W3TSP4763) | 4000-0073 | Quarterly | 7 | 7 | 7 | 7 | ||||||||||
| 7 | Carbon Block PTG (W2T912087) | 3027145 | Quarterly | 7 | 7 | 7 | 7 | ||||||||||
| 7 | AAMI (W3TSP7119) | AAMI TEST | Semi-Annually | 7 | 7 | ||||||||||||
| 7 | LAL Water Test (48 Hour) (W3TSP7171) (Evoqua to Pull) | LAL TEST | Monthly | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
| 7 | Bacteria Water Test (W3TSP7170) (Evoqua to Pull) | BACTERIA TEST | Monthly | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
| 1 | Unscheduled/Emergency (W3TSP7001) | (W3TSP7001) | |||||||||||||||
| RO system operation verification | quarterly | ||||||||||||||||
| Carbon tank rebed x 2 | annually | ||||||||||||||||
| RO unit - storage tank vent filters | semi annually | ||||||||||||||||
| RO unit- control panel resistivity monitor | annually | ||||||||||||||||
| UV sterilizer - bulb replacement | annually | ||||||||||||||||
| DI mixed bed polishing tanks x 2 | quarterly | ||||||||||||||||
| final filter endotoxin replacement | semi annually | ||||||||||||||||
| disinfection of central systems (after hours, Sunday) | monthly | ||||||||||||||||
| unscheduled/emergency work on RO system |