Attachment C - Drawings.pdf
PDF 24 MB Posted
- Attached to
- Replace and Remediate Courtyards 1, 3, & 4 (Project No. 605-22-408) Federal contract opportunity
- Solicitation number
- 36C26224B0003
About this file
This federal contract opportunity solicitation seeks to renovate three patient courtyards at the VA Loma Linda Healthcare System facility in Loma Linda, California. The project will be completed in three phases, renovating one courtyard per phase. Work includes general construction, alterations, mechanical, electrical and utility system work, as well as necessary demolition and removal of existing structures. All work must be performed in accordance with solicitation terms and conditions, specifications, drawings when available, and applicable local and VA building codes. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Award Notice (Contract 36C26224C0149).pdf | ||
| Amendment 0004 (SF30) - Solicitation 36C26224B0003.pdf | ||
| RFI Notice - Solicitation No. 36C26224B0003.pdf | ||
| Attachment E - Lead and Asbestos Survey.pdf | ||
| Amendment 0003 (SF30) - Solicitation 36C26224B0003.pdf | ||
| Attachment A - Statement of Work (SOW) - Revised (29 Feb 2024).pdf | ||
| Attachment B - Specifications (Updated Section 01 45 00).pdf | ||
| Attachment F - Structural Complete Set.pdf | ||
| Amendment 0002 (SF30) - Solicitation 36C26224B0003.pdf | ||
| Amendment 0001 (SF30) - Solicitation 36C26224B0003.pdf | ||
| Pre-Bid Site Visit Sign-In Sheet (36C26224B0003).pdf | ||
| Solicitation (SF 1442) - 36C26224B0003.pdf | ||
| Attachment D - Wage Determination (CA20240026).pdf | ||
| Attachment A - Statement of Work (SOW).pdf | ||
| Attachment B - Specifications.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
GI001
COVER SHEET REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
REPAIR & REMEDIATE COURTYARDS 1, 3, & 4 : 605-22-408
LOMA LINDA, CALIFORNIA
VA LOMA LINDA HEALTHCARE SYSTEM
SHEET INDEX
SHEET NUMBER SHEET NAME
11_PLUMBING
P001 PLUMBING COVER SHEET - SYMBOLS & LEGENDS
P002 PLUMBING COVER SHEET - GENERAL NOTES
PD201 PLUMBING DEMOLITION PLAN - COURTYARD 1
PD202 PLUMBING DEMOLITION PLAN - COURTYARD 3
PD203 PLUMBING DEMOLITION PLAN - COURTYARD 4
PP101 PLUMBING PLAN - LEVEL 1 INTERSTITIAL - COURTYARD 1
PP102 PLUMBING PLAN - LEVEL 1 INTERSTITIAL - COURTYARD 3
PP103 PLUMBING PLAN - LEVEL 1 INTERSTITIAL - COURTYARD 4
PP201 PLUMBING PLAN - LEVEL 2 - COURTYARD 1
PP202 PLUMBING PLAN - LEVEL 2 - COURTYARD 3
PP203 PLUMBING PLAN - LEVEL 2 - COURTYARD 4
PP901 PLUMBING ISOMETRICS - COURTYARD 1
PP902 PLUMBING ISOMETRICS - COURTYARD 2
PP903 PLUMBING ISOMETRICS - COURTYARD 3
SHEET INDEX
SHEET NUMBER SHEET NAME
00_GENERAL
GI001 COVER SHEET
GI002 VICINITY MAP, SYMBOLS AND NOTES
GI003 ICRA PLAN - LEVEL 2
GI004 ICRA PLAN - LEVEL 1
GI005 ICRA
07_STRUCTURAL
SS001 GENERAL NOTES
SS201 ENLARGED CANOPY FRAMING PLANS
SS301 FRAMING DETAILS
08_ARCHITECTURAL
AD101 DEMOLITION PLAN - COURTYARD 1
AD102 DEMOLITION PLAN - COURTYARD 3
AD103 DEMOLITION PLAN - COURTYARD 4
AS100 OVERALL COURTYARD PLAN - LEVEL 2
AS111 ENLARGED COURTYARD PLAN - LEVEL 2
AS121 CONCRETE PAVING PLAN (CLIN-0001, BASE BID)
AS122 CONCRETE PAVING PLAN (CLIN-0002)
AS141 SHADING DEVICE PLAN
AS201 CANOPY & DETAILS
AS300 BUILDING SECTION - COURTYARD #1
AS301 BUILDING SECTION - COURTYARD #3
AS302 BUILDING SECTION - COURTYARD #4
AS401 WALL SECTIONS & DETAILS
AS900 PERSPECTIVE VIEW - COURTYARD #1
AS901 PERSPECTIVE VIEW - COURTYARD #3
AS902 PERSPECTIVE VIEW - COURTYARD #4
Revisions: Date:
0 COLUMN GRID LINE
DOOR NUMBER
SYMBOL
DETAIL - SECTION
POSITION ON SHEET
SHEET NUMBER
DETAIL - PLAN/ RCP
POSITION ON SHEET
SHEET NUMBER
WALL SECTION
POSITION ON SHEET
SHEET NUMBER
EXTERIOR ELEVATION
POSITION ON SHEET
SHEET NUMBER
INTERIOR ELEVATION
POSITION ON SHEET
SHEET NUMBER
EXTERIOR WALL TYPE TAG
EXTERIOR WINDOW
SIGN TYPE, SEE SIGNAGE
SCHEDULE
DRAWING NUMBER
DRAWING SCALE
VIEW TITLE
NOTES BY NUMBER
DRAWING REVISION
LEVEL DATUM
LEVEL NAME
LEVEL ELEVATION
NORTH ARROW
INTERIOR WINDOW
GRAPHIC SCALE
0 4'-0" 8'-0" 16'-0"
-G D
XX
XX
XXXX
7'-0" R 3'-11"
100°
SIM
X
X-XXX
DIMENSION TO FACE OF FINISH,
FACE OF CONCRETE, COLUMN
CENTERLINE, OR AS NOTED.
CENTERLINE
X
X X
X
A101
SIM
A101
SIM
ROOM TAG (FOR SPECIALTY PLANS)
ROOM NAME
ROOM NUMBER
FLOOR FINISH
ROOM NAME
XXXX
FLOR
BASE
WALL
CEIL BASE TYPE
WALL FINISH
CEILING TYPE
CEILING HEIGHT
A
A101
SIM
Name Elevation
1/8" = 1'-0"
AC1
INTERIOR PARTITION TYPE TAGA3
Room name
Room name
ROOM NAME
ROOM NUMBER
ROOM AREA
INSULATION (IF NEEDED)
ROOM TAG (FOR STANDARD PLANS)
BATT. INSULATION
CAST IN PLACE CONCRETE
CAST STONE
CONCRETE MASONRY/CMU
EARTH IN SECTION
FACE BRICK
GYP./GYPSUM BOARD
MARBLE
PARTICLE BOARD/PLYWOOD
ROOF INSULATION
STUCCO
CONTINUOUS WOOD BLOCKING
DISCONTINUOUS WOOD BLOCKING
FINISHED WOOD
OWNER
ARCHITECT
O'BRIEN ENGINEERING, INC.
CONSTRUCTION MANAGER
MECHANICAL, PLUMBING, AND
ELECTRICAL ENGINEERS
O'BRIEN ENGINEERING, INC.
COR, MR. BRIAN PORTER
VA LOMA LINDA HEALTHCARE SYSTEM
VAN LEUVEN ST
VICINITY MAP
NOT TO SCALE
N
RAIL ROAD
B E
N T
O N
S T
SHEPARDSON DR
B E
LL
A
IR
E
S T
P O
P
LA
R S
T
R
IC
H M
O N
T R
D
B E
N T
O N
S T
B E
N T
O N
S T
COLE ST
PROSPECT AVE
BARTON RD BARTON RD BARTON RD
B E
N T
O N
S T
LO
M
A L
IN
D
A R
D
M O
U N
T A
IN
V
IE
W
A V
E M
O U
N T
A
IN
V
IE
W A
V E
M O
U N
T A
IN
V
IE
W
A V
E
VA LOMA LINDA
HEALTHCARE SYSTEM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
GI002
VICINITY MAP, SYMBOLS AND
NOTES
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
DRAWING LEGENDABBREVIATIONS
ACT. ACTUAL
ADJ. ADJUSTABLE
A.F.F. ABOVE FINISH FLOOR
A.F.S. ABOVE FINISH SLAB
AGG. AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
ALUM. ALUMINUM
BLDG. BUILDING
BK. BRICK
BM. BEAM
CAB. CABINET
CPT. CARPET
C.J. CONTROL JOINT
CENTERLINE
CG CORNER GUARD
CLG. CEILING
COL. COLUMN
CONC. CONCRETE
COND. CONDITION
CONT. CONTINUOUS
C.T. COUNTERTOP
DBL. DOUBLE
DEMO. DEMOLITION
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
DN. DOWN
DWG. DRAWING
E.W.C. ELECTRIC WATER COOLER
EA. EACH
E.J. EXPANSION JOINT
EXP. EXPANSION
E.W. EACH WAY
EXT. EXTERIOR
EXIST. EXISTING
F.E.C. FIRE EXTINGUISHER CABINET
F.D. FINISH DIMENSION
F.D.V.B. FIRE DEPARTMENT VALVE BOX
F.F. FINISH FLOOR
FIN. FINISH(ED)
FRT. FIRE RETARDANT TREATED
G.I. GALVANIZED IRON
G.B./GYP.BD. GYPSUM BOARD
GA. GAUGE
GALV. GALVANIZED
GL. GLASS
H.M. HOLLOW METAL
H.S. HORIZONTAL IN SPLASH
I.C.U. INTENSIVE CARE UNIT
ICRA INFECTION CONTROL RISK ASSESSMENT
INT. INTERIOR
INSUL. INSULATION
I.T.C. INSTALLED THIS CONTRACT
K.S. KNEE SPACE
LAM. LAMINATED
LAV. LAVATORY
L.L.V. LONG LEG VERTICAL
L.L.H. LONG LEG HORIZONTAL
MANUF. MANUFACTURER
MAX. MAXIMUM
MECH. MECHANICAL
MIN. MINIMUM
M.O. MASONRY OPENING
MTL./MET. METAL
MNT. MOUNTED
N/A NOT APPLICABLE
NOM. NOMINAL
N.T.S. NOT TO SCALE
N.I.C. NOT IN CONTRACT
O.C. ON CENTER
O.D. OVERFLOW DRAIN
O.H/OPP.H. OPPOSITE HAND
P.D. PLAN DIMENSION
PLAS. LAM. PLASTIC LAMINATE
P.T. PORCELAIN TILE
P.T.D. PAPER TOWEL DISPENSER
RB RUBBER BASE
R./REV. REVISED/REVERSE
R./RAD. RADIUS
REINF. REINFORCE
REF. REFERENCE/REFER TO
REQ'D REQUIRED
R.D. ROOF DRAIN
RM. ROOM
R.O. ROUGH OPENING
SCHED. SCHEDULED
SAB. SOUND ATTENUATION BATTS
SHT. SHEET
SIM. SIMILAR
SL. SLOPE
STL. STEEL
S.S. STAINLESS STEEL
S.S.V. SOLID SURFACE VENEER
SUSP. SUSPENDED
S.V. SHEET VINYL
T.A.S. TEXAS ACCESSIBILITY STANDARDS
T.B. TACK BOARD
T.D.H. TEXAS DEPARTMENT OF HEALTH
TEMP. TEMPERED GLASS
THK. THICK
TOIL. TOILET
TYP. TYPICAL
U.C. UNDER COUNTER
UCR UNDER COUNTER REFRIGERATOR
U.L. UNDERWRITERS LABORATORIES
U.N.O. UNLESS NOTED OTHERWISE
UR. NEW URINAL
VCT VINYL COMPOSITION TILE
V.T. VINYL TILE
VERT. VERTICAL
W.C. NEW WATER CLOSET
WDW. WINDOW
WD. WOOD
WH WATER HEATER
W/ WITH
W/O WITHOUT
MATERIALS LEGEND GENERAL NOTES
1. THE CONTRACT DRAWINGS AND THE PROJECT MANUAL COMPRISE THE CONTRACT
DOCUMENTS. CONTRACTOR(S) SHALL BE FAMILIAR WITH ALL ASPECTS OF THE CONTRACT
DOCUMENTS, BEFORE SUBMITTING A BID.
2. THESE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. IN THE EVENT OF
OMISSION OF NECESSARY DIMENSIONS, CONTRACTOR SHALL NOTIFY THE COR.
3. VERIFY ALL DIMENSIONS, GRADES, AND EXISTING CONDITIONS AT JOB SITE. WHERE
DIMENSIONS ARE LABELED "VERIFY", THE CONTRACTOR SHALL NOTIFY THE COR IF DIMENSION
VARIES FROM DIMENSION SHOWN PRIOR TO CONSTRUCTION.
4. ALL DIMENSIONS ON PLANS ARE TO THE FACE OF FINISHED WALL, OR CONCRETE UNLESS
NOTED OTHERWISE.
5. CONTRACTOR MAY USE A CRANE AS PART OF CONSTRUCTION AND DEMOLITION OF THIS
SCOPE OF WORK. IF CONTRACTOR USES OVERHEAD CRANE, A CRANE OPERATIONAL AND
SAFETY PLAN MUST BE SUBMITTED TO THE COR FOR APPROVAL BEFORE ANY SUCH
OPERATIONS ARE AUTHORIZED TO BEGIN.
CLIN ITEM DESCRIPTIONS
CLIN 0001, BASE BID: CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT,
SUPERVISION AND TESTING FOR RENOVATING COURTYARDS 1, 3, & 4 AS DESCRIBED IN THE
CONTRACT DOCUMENTS.
CLIN 0002: DEDUCTIVE ALTERNATE TO ELIMINATE COLOR / STAINING AND PATTERN OF CONCRETE.
CLIN 0003: DEDUCTIVE ALTERNATE TO ELIMINATE TENSILE CABLE SUPPORTED SHADING DEVICES
FOR COURTYARDS 1, 3, & 4.
5,960 SF
COURTYARD #4
CY02-4
6,020 SF
COURTYARD #3
CY02-3
4,022 SF
COURTYARD #1
CY02-1
EXIST. BLDG.
DESIGNATED ELEVATOR
USED BY CONTRACTOR
COORD. W/ COR
GENERAL ICRA NOTES:
A. REFER GI005 FOR DESCRIPTION OF REQUIRED INFECTION CONTROL
B. IN ADDITION TO INFECTION CONTROL REQUIREMENTS LISTED ON GI005, CONTRACTOR SHALL
PROVIDE FLOOR COVERINGS ALONG INDICATED HALL ROUTE TO PREVENT DAMAGE AND SOILING
OF HOSPITAL FLOORING.
C. CONTRACTOR MUST COVER DEMOLISHED MATERIAL DURING REMOVAL THROUGH HOSPITAL
CORRIDORS. CONTRACTOR MUST SUBSEQUENTLY CLEAN ANY SPILLAGE OF MATERIAL IN
HOSPITAL CORRIDORS IMMEDIATELY.
D. CONTRACTOR IS RESPONSIBLE FOR PREVENTING ANY DAMAGE TO EXISTING HOSPITAL FINISHES
DURING DEMOLITON AND CONSTRUCTION ACTIVITIES. TO PREVENT WEAR AND DAMAGE ON
HOSPITAL FLOORING, CONTRACTOR SHALL NOT EXCEED RECOMMENDATION OF 400 POUNDS PER
AXLE FOR MATERIALS TRANSPORTED THROUGH THE CORRIDORS ON CARTS OR
DOLLIES. BEFORE BEGINNING TRANSPORTATION THROUGH CORRIDORS, CONTRACTOR SHALL
VERIFY CONDITION OF HALLWAY FLOORING. CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR
ENSURING NO DAMAGES TO HOSPITAL MATERIALS AND FINISHES DURING CONSTRUCTION
ACTIVITIES, AND SHALL REPAIR AND REPLACE ANY DAMAGED FINISHES AT NO ADDITIONAL COST
TO THE GOVERNMENT.
E. COORDINATE WITH COR TO USE THIS CORRIDOR OUTSIDE OF OPERATIONAL HOURS.
ICRA PLAN LEGEND
PRIMARY ROUTE FOR CONSTRUCTION MATERIALS FLOW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
GI003
ICRA PLAN - LEVEL 2 REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
3/64" = 1'-0"
ICRA PLAN - LEVEL 2
N
DESIGNATED ELEVATOR
USED BY CONTRACTOR
COORD. W/ COR
GENERAL ICRA NOTES:
A. REFER GI005 FOR DESCRIPTION OF REQUIRED INFECTION CONTROL
B. IN ADDITION TO INFECTION CONTROL REQUIREMENTS LISTED ON GI005, CONTRACTOR SHALL
PROVIDE FLOOR COVERINGS ALONG INDICATED HALL ROUTE TO PREVENT DAMAGE AND SOILING
OF HOSPITAL FLOORING.
C. CONTRACTOR MUST COVER DEMOLISHED MATERIAL DURING REMOVAL THROUGH HOSPITAL
CORRIDORS. CONTRACTOR MUST SUBSEQUENTLY CLEAN ANY SPILLAGE OF MATERIAL IN
HOSPITAL CORRIDORS IMMEDIATELY.
D. CONTRACTOR IS RESPONSIBLE FOR PREVENTING ANY DAMAGE TO EXISTING HOSPITAL FINISHES
DURING DEMOLITON AND CONSTRUCTION ACTIVITIES. TO PREVENT WEAR AND DAMAGE ON
HOSPITAL FLOORING, CONTRACTOR SHALL NOT EXCEED RECOMMENDATION OF 400 POUNDS PER
AXLE FOR MATERIALS TRANSPORTED THROUGH THE CORRIDORS ON CARTS OR
DOLLIES. BEFORE BEGINNING TRANSPORTATION THROUGH CORRIDORS, CONTRACTOR SHALL
VERIFY CONDITION OF HALLWAY FLOORING. CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR
ENSURING NO DAMAGES TO HOSPITAL MATERIALS AND FINISHES DURING CONSTRUCTION
ACTIVITIES, AND SHALL REPAIR AND REPLACE ANY DAMAGED FINISHES AT NO ADDITIONAL COST
TO THE GOVERNMENT.
E. COORDINATE WITH COR TO USE THIS CORRIDOR OUTSIDE OF OPERATIONAL HOURS.
ICRA PLAN LEGEND
PRIMARY ROUTE FOR CONSTRUCTION MATERIALS FLOW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
GI004
ICRA PLAN - LEVEL 1 REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
3/64" = 1'-0"
ICRA PLAN - LEVEL 1
GENERAL ICRA NOTE:
A. INFORMATION PROVIDED ON THIS SHEET IINCLUDES INFECTION
CONTROL REQUIREMENTS AS PROVIDED BY THE VA.
CONTRACTOR TO COMPLY WITH ALL APPLICABLE INFECTION
CONTROL REQUIREMENTS. CONTRACTOR TO COORDINATE
WITH COR FOR ANY CLARIFICATION REQUIRED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
GI005
ICRA REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
1 OF 8 2 OF 8 3 OF 8 4 OF 8
5 OF 8 6 OF 8 7 OF 8 8 OF 8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006 972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/23 RLW BWTRevisions: Date:
1151 W. PIONEER PKWY. (817) 277-6686
ARLINGTON, TX 76013
Texas Registered Engineering Firm F-8284 C 2022 Copyright R. L. Woods & Associates, LLC
Structural and Forensic Engineering R. L. Woods & Associates, LLC
01-03-23
ISSUE FOR BID
OEI - LBL Joint Venture LLC
SS001
GENERAL NOTES
FLOOR
FLANGE
FIXED CONNECTION
KIPS
JOISTS
JOINT
INTERMEDIATE
INTERIOR
INSIDE FACE
INSIDE DIAMETER
INFORMATION
HORIZONTAL LOAD
HORIZONTAL
HIGH POINT
HEIGHT
HEADED STUD
GYPSUM BOARD
GRADE BEAM
GRADE
GENERAL
GALVANIZED
GAGE OR GAUGE
FOUNDATION
FOOTING
FINISHED FLOOR
FINISH(ED)
FAR SIDE
FACE TO FACE
EXTERIOR
EXISTING
EXPANSION JOINT
EXPANSION
EQUAL(EQUALLY)
ENGINEER
ELEVATOR
ELEVATION
ELECTRICAL
EACH WAY
EACH FACE
EACH
DRAWING
DOWN
DOWELS
DOUBLE
DIMENSION
DIAMETER
DIAGONAL BRACE
DIAGONAL
DEAD LOAD
DETAIL
COORDINATE
CONSTRUCTION JOINT
CONTINUOUS
CONNECTION(S)
CONDENSING UNIT
CONCRETE MASONRY UNIT
CONCRETE
COMPRESSION
- K.
- INTERM.
- JST(S)
- JT.
- INT.
- I.F.
- I.D.
- INFO.
- GR.
- GYP. BD.
- H.L.
- HORIZ.
- H.P.
- HT.
- H.S.
- G.B.
- GEN.
- GALV.
- GA.
- FDN.
- FTG.
- FL.
- FLG.
- F.C.
WELDED WIRE MESH (FABRIC)
X-BRACING
WORK POINT
WATERSTOP
WITH
WOOD
WIND LOAD
WEIGHT
- XB
- W.P.
- WD.
- W/
- W.L.
- W.W.F.
- WT.
- W.S.
UNLESS OTHERWISE NOTED
TOP OF STRUCTURAL CONCRETE
TOP OF STRUCTURAL STEEL
TRANSVERSE
TOTAL LOAD
TOP OF WALL
VERTICAL
TYPICAL
TOP OF PIER CAP
TOP OF PIER
TOP OF METAL DECK
TOP OF JOIST
TOP OF FOOTING
TOP OF BEAM
TOP & BOTTOM
TONGUE & GROOVE
- T.O.S.C.
- VERT.
- U.N.O.
- TYP.
- TRAN.
- T.L.
- T.O.W.
- T.O.S.S.
- T.O.P.C.
- T.O.P.
- T.M.D.
- T.O.J.
- T.O.F.
- T.O.B.
- T & B
- T & G
- DRWG.
- FIN. FL.
- FIN.
- F.S.
- F/F
- EXT.
- EXIST. ; (E)
- E.J.
- EXP.
- ELEC'L.
- EQ.
- ENGR.
- ELEV.
- EL.
- E.W.
- E.F.
- EA.
- DET.
- DIA. OR
- DN.
- DWL(S)
- DBL.
- DIM.
- D.B.
- DIAG.
- D.L.
- CONN.(S)
- COORD.
- C.J.
- CONT.
- CU
- CMU
- CONC.
- C.
- V.SHEAR
TEMPERATURE
TOP CHORD EXTENSION
SYMMETRICAL
STRUCTURAL
STRUCTURE
THICK
TENSION
SUPPORT
SPECIFICATIONS
SLIP CONNECTION
STIRRUPS
STIFFENER
STEEL
STANDARD
SPACE
SIMILAR
SHEET
- THK.
- TEMP.
- TCX
- SYMM.
- SUPT.
- STRUCT'L.
- STRUCT.
- T.
- STIR.
- STIFF.
- STL.
- STD.
- SPEC.
- SP.
- S.C.
- SIM.
- SHT.
REMAINDER
SAWN JOINT
ROOF DRAIN
ROOF TOP UNIT
RIGID FRAME
SECTION
SCHEDULE
REQUIRED
REINFORCING
PROJECTION
PRECAST CONCRETE
PIPE BRACE
REFER
RADIUS
POINT
PLATE
- REM.
- SECT.
- SCHED.
- S.J.
- R.D.
- RTU
- R.F.
- REQ'D.
- REINF.
- REF.
- RAD.
- PROJ.
- P/C
- PT.
- P.B.
L- P ; PL.
COLUMN
CLEAR
CHANNEL
CENTERED
CENTER LINE
CENTER TO CENTER
CEILING
BUILDING LINE
BUILDING
BRIDGING
BOTTOM CHORD EXTENSION
BOTTOM
BOTH WAYS
BLOCKING
BETWEEN
BEARING
BEAM
BASE PLATE
BACK TO BACK
AIR HANDLING UNIT
AIR CONDITIONER
AT
ARCHITECTURAL
APPROXIMATE
ANGLE
AND
ANCHOR BOLT
ALTERNATE
ADJACENT
ADDITIONAL
ABOVE FIN. FL.
ABBREVIATIONS USED ON STRUCTURAL DRAWINGS
L- BP
L- C
- COL.
- CL.
- C
- CNTRD.
- C/C
- CLG.
- B.L.
- B.W.
- BLDG.
- BRDG.
- BCX
- BOT.
- BLK'G.
- BTWN.
- BRG.
- BM.
- APPROX.
- B/B
- AHU
- A/C
- ARCH'L.
- L
- A.F.F.
- A.B.
- ALT.
- ADJ.
- ADDT'L.
- MIN.MINIMUM
PERPENDICULAR
PENETRATION
OUTSIDE FACE
OUTSIDE DIAMETER
OPPOSITE HAND
OPENING(S)
PERIMETER
OPPOSITE
ON CENTER
NOT TO SCALE
MOMENT CONNECTIONS
MISCELLANEOUS
NEAR SIDE
NUMBER
MOMENT
- PERP.
- PERIM.
- PEN.
- O.F.
- O.D.
- O.H.
- OPP.
- OPNG.(S)
- O.C.
- NO.
- N.T.S.
- N.S.
- M.C.
- MISC.
- M.
LESS THAN OR EQUAL TO
LARGER THAN OR EQUAL TO
LONG LEG VERTICAL
MECHANICAL
MANUFACTURER
MEZZANINE
METAL
MAXIMUM
MATERIAL
LOW POINT
LONG LEG HORIZONTAL
LONGITUDINAL
LIVE LOAD
- LLV
- MEZZ.
- MET.
- MECH'L.
- MAX.
- MAT'L.
- MFR.
- L.P.
- LLH
- LONG.
- L.L.
DEFORMED BAR ANCHOR - DBA.
LONG SIDE VERTICAL - LSV
NEW - (N)
FIELD VERIFY - F.V.
1. Design loads are as follows:
A. Roof live loads 20 PSF B. Roof dead loads (Canopy System) 7 PSF C. Ground snow loads: 0 PSF D. Wind pressure: unless noted otherwise, per ASCE 7-16 for:
i. Basic wind speed = 105 mph (Risk Category IV).
ii. Exposure C.
iii. Component and cladding wind pressure, PSF, for Wind Area = 10 SF:
a. Roof Overhang Zone 1: -35.88 E. Seismic provisions for overall building (assumed per ASCE 7-16):
a. Seismic Risk Category: IV.
b. Seismic Importance Factor: 1.5
c. Mapped Spectral Response Acceleration Parameters:
Ss =2.261g S1 =.9030g
d. Spectral Response Coefficients: Sds = 1.809; Sd1 = 1.204
e. Site Class: E
f. Seismic Design Category: F
g. Seismic Force Resisting System: Dual systems with intermediate moment frames capable of resisting at Least 25% of prescribed seismic loading
h. Design Base Shear: n/a
i. Seismic Response Coefficient (CS) = 0.5426
j. Analysis procedure: Equivalent Frame Method
F. Seismic provisions for canopies - assumed as non-structural appendages (per ASCE 7-16):
a. Component application factor: 2.5.
b. Component Importance Factor: 1.0
c. Component Response Factor: 1.5
2. Modifications to structure were designed in accordance with the IBC 2021 edition.
3. Consult structural engineer if design weights of canopies differ from those indicated on structural plans.
4. All existing conditions shall be field verified.
5. Contractor shall verify all dimensions prior to start of construction.
6. General contractor shall be responsible for coordination of other trades (Mech'l, Elec'l, etc.) Prior to fabrication and installation of materials.
7. General contractor shall be responsible for coordination of architectural and structural drawings prior to fabrication, forming, or placement of materials. General contractor shall report discrepancies immediately to architect and shall proceed with construction only after discrepancy has been resolved.
8. The details designated as "Typical Details" apply generally to the drawings in all areas where conditions are similar to those shown in the details.
1. Structural steel shall conform to AISC “Specification For The Design, Fabrication And Erection Of Structural Steel For Buildings”, latest edition.
2. All structural steel wide flange shapes shall be ASTM A992 (grade 50). HSS shapes shall be A500
gr. B. Standard pipe shall be ASTM A53, grade B. All other structural steel shall be A36.
3. Welded construction shall conform to the American Welding Society “Structural Welding Code”, D1.1
4. All welding shall be performed by welders certified with the last 12 months.
5. Full and partial penetration welds performed in the field shall be ultrasonically tested.
6. When welds are not called-out on drawings, they are minimum size continuous fillet welds in accordance with AWS D1.1.
7. All welds shall be made using E70 series electrodes.
8. All bolted connections shall use ASTM F3125 bolts unless noted otherwise. Temporary erection bolts may be ASTM A307
9. All bolts exposed to the elements shall be hot dipped galvanized or group 1, alloy 304 stainless steel 10.Submit structural steel shop drawings to architect for approval prior to fabrication.
11.All structural steel shall be shop primed. Primer shall be gray oxide with minimum 2 mil dry thickness.
12.Temporary construction bracing of the structural steel frame shall remain in place until after the floor and roof deck attachments have been completed and all permanent bracing has been installed.
13.The lifting and erection of pre-assembled elements, such as trusses or pre-fabricated framing, are considered special erection conditions. The selection of lift points and erection techniques are the responsibility of the contractor. Locate and provide sufficient lift points to prevent overstress and/or distortion of any components within the assembly. Provide temporary strong-backs, stiffeners and/or lifting devices as required.
1. Design and construction of premanufactured awnings and canopies are considered delegated designs and are the responsibility of the manufacturer. Canopy manufacturer shall coordinate connections to structure with Structural Engineer of Record.
2. Awnings and canopies shall be designed and constructed in accordance with the local building code.
3. Connections to building must be to structural members. Connections to wall veneers will not be allowed.
4. The contractor shall coordinate the manufacturer's work with all trades and conform to performance and appearance criteria indicated in sections and details provided by the architect.
5. Submit shop drawings and connection details for review.
6. Provide structural calculations, sealed by an engineer licensed to practice in any US state.
7. Design loads and structural performance criteria shall be as follows:
A. Wind: see general notes for wind speed and exposure. Design for uplift forces specified by the building code, limit vertical deflection to l/180. Wind controls uplift loading.
B. Seismic: see general notes for seismic design parameters. Seismic controls lateral loading. Limit lateral deflection to l/240.
C. Gravity:
i. Roof live load: 20 psf.
ii. Roof dead load: structure weight + weight of applied materials.
D. Deflections limits: LL= l/240; total load = l/180.
1. Shop drawings and/or product data for the following items are to be submitted to the structural engineer for review:
A. Canopy shop drawings and calculations B. Structural steel shop drawings and data
2. General contractor shall pre-check all shop drawings before submission to the engineer for review.
All submittals materials must bear the review stamp of the general contractor.
3. Allow 10 working days after date of delivery to the architect for engineer's review of shop drawings.
4. The use of reproductions of theses contract drawings, including the use of electronic files, by any contractor, subcontractor, erector, fabricator, or material supplier in lieu of the independent preparation of shop drawings signified their acceptance of all information shown hereon as correct and obligates themselves to any job expense, real or implied, arising due to any errors that may occur thereon. Such use of reproductions of these contract documents will not be allowed without prior consent from the engineer.
1. An independent testing lab shall be engaged to perform quality control testing and inspections.
2. Contractor shall cooperate and coordinate activities with testing lab.
3. Testing lab shall perform the following services:
A. Provide general inspection of structural steel connections with visual inspection of all field welds.
4. Special inspections are not required for this project.
GENERAL NOTES
GENERAL CONDITIONS
STRUCTURAL STEEL
PREMANUFACTURED AWNINGS AND CANOPIES
SHOP DRAWING REVIEW AND SUBMITTAL NOTES
TESTING LAB SERVICES
/2
7/
:1 1:
A
M
23 22 21 20 19 18
K
L
K.5
112'-6"
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
'-0
'-0
'-0
(E) W24x68(E) W24x61(E) W24x68(E) W24x68(E) W24x61
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E) W8x10
(E) C12x20.7
NEW CANOPY
1/S S3
111213141516
E.5
F
E
'-0
'-0
'-0
112'-6"
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
(E) W24x68 (E) W24x61 (E) W24x68 (E) W24x68 (E) W24x61
(E ) W x1
(E) C12x20.7
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E ) W x1
(E) W8x10
NEW CANOPY1/S
S3
NEW CANOPY1/S
S3
SS201
ENLARGED CANOPY
FRAMING PLANS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006 972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/23 RLW BWTRevisions: Date:
1151 W. PIONEER PKWY. (817) 277-6686
ARLINGTON, TX 76013
Texas Registered Engineering Firm F-8284 C 2022 Copyright R. L. Woods & Associates, LLC
Structural and Forensic Engineering R. L. Woods & Associates, LLC
01-03-23
ISSUE FOR BID
OEI - LBL Joint Venture LLC
N
SCALE: 1/8" = 1'-0"
1 ENLARGED CANOPY FRAMING PLAN - COURTYARD 1
KEY PLAN
N
SCALE: 1/8" = 1'-0"
2 ENLARGED CANOPY FRAMING PLAN - COURTYARD 4
/2
7/
:1 2:
FLOOR EL.
GRID
2'- 6 1
5/1 6"
5'- 3 1
1/1 6"
8 3 /8"
F.
V.
F.
V.
C CANOPY CONN.L
EXIST. W24 BEAM,
REF. PLAN
NEW L3x3x1/4
3/SS301
2/SS301
3"
3'-0 1/2" F.V.
EXIST. C12x20.7
EXIST. 1/2"Ø RODS @ 11'-3" O.C.
NEW C10x15.3
STUCCO VENEER
EA. LEG
2"3/16
EXIST. C12x20.7
EXIST. 1/2"Ø RODS
@ 11'-3" O.C.
NEW C10x15.3
STUCCO VENEER
4"3/16
C CANOPY CONN.L
NEW L3x3x1/4
EXIST. 1/2"Ø RODS
@ 11'-3" O.C.
NEW C10x15.3
STUCCO VENEER
8 3 /8"
4/S S3
COMPRESSION SPACERS
BY CANOPY MFR.
2" 4"
2"
2" 3" 3" 2"
NEW VERT. CHANNEL
THRU-BOLTS BY
CANOPY MFR.
2"3/16
SS301
FRAMING DETAILS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006 972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/23 RLW BWTRevisions: Date:
1151 W. PIONEER PKWY. (817) 277-6686
ARLINGTON, TX 76013
Texas Registered Engineering Firm F-8284 C 2022 Copyright R. L. Woods & Associates, LLC
Structural and Forensic Engineering R. L. Woods & Associates, LLC
01-03-23
ISSUE FOR BID
OEI - LBL Joint Venture LLC
CANOPY SECTION
1 TYPICAL DETAIL
SCALE: 1/2" = 1'-0"
2 DETAIL
SCALE: 1" = 1'-0"
3 DETAIL
SCALE: 1" = 1'-0"
4 DETAIL
SCALE: 3" = 1'-0"
/2
7/
:1 2:
GENERAL NOTES:
1. REMOVE ALL LANDSCAPE IMPROVEMENTS AND ROOFING
SYSTEMS EXCEPT ROOF STRUCTURE. REFER TO THE PHOTOS
AND SECTION DETAIL ON THIS SHEET FOR MORE DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
MATERIALS IN THE FIELD AND REPORT ANY DISCREPANCIES
TO THE COR.
3. THE CONTRACTOR SHALL COORDINTE WITH COR FOR HOURS
OF DEMOLITION
4. THE CONTRACTOR DEMOLISHES AND REMOVES ELECTRICAL
COMPONENTS THAT ARE NO LONGER REQUIRED. THE
CONTRACTOR SHALL ROUTE CONDUCTORS BACK TO THE
NEAREST JUNCTION BOX. REMOVE CONDUCTORS AND
CONDUITS AS REQUIRED.
5. THE CONTRACTOR IS TO COORDINATE WITH COR REGARDING
EXISTING FURNITURE BEFORE DEMOLITION BEGINS.
FURNITURE SHALL EITHER BE RETURNED TO VA OR DISPOSED
OF BY THE CONTRACTOR AT THE DIRECTION OF THE COR.
6. REFER TO PD201, PD202, AND PD203 FOR PLUMBING
DEMOLITION.
23 22 21 20 19 18
K
L
K.5
COURTYARD #1
SOFFIT ABOVE
SOFFIT ABOVE
1 1
DEMOLITION PLAN LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
BOUNDARY OF DEMOLITION
TRENCH DRAIN TO BE DEMOLISHED
AREA DRAIN TO BE DEMOLISHED
KEY PLAN
3 4
EXIST. STRUCT. BEAM TO REMAIN
EXIST. COMPOSITE DECKING
TO REMAIN
EXIST. STRUCT. SLAB
TO REMAIN
FINISH SLAB W/ WIRE MESH
TO BE REMOVED
EXIST. LIQUID WATERPRROFING
TO BE REMOVED
V A
R
IE
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AD101
DEMOLITION PLAN - COURTYARD
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
N
1/8" = 1'-0"
DEMOLITION PLAN - COURTYARD 1
3" = 1'-0"
TYPICAL SECTION DETAIL - DEMOLITION
DEMOLITION KEYNOTES...
KEY VALUE KEYNOTE TEXT
1 EXISTING PAVING INCLUDING MULCH AND RIVER
ROCK REMOVED. SEE SECTIONAL DETAIL FOR
DEMOLITION.
2 EXISTING PLANTERS REMOVED. PATCH AND
REPAIR DAMAGED PORTION OF WALL TO MATCH
EXISTING AFTER DEMOLITION.
3 EXISTING STAIRS AND RAMPS REMOVED. PATCH
AND REPAIR DAMAGED PORTION OF WALL TO
MATCH EXISTING AFTER DEMOLITION.
4 EXISTING CANOPY REMOVED. PATCH AND
REPAIR DAMAGED PORTION OF WALL TO MATCH
EXISTING AFTER DEMOLITION.
5 EXISTING ELECTRICAL COMPONENTS REMOVED.
6 EXISTING BOLLARD W/ CARD READER TO
REMAIN
GENERAL NOTES:
1. REMOVE ALL LANDSCAPE IMPROVEMENTS AND ROOFING
SYSTEMS EXCEPT ROOF STRUCTURE. REFER TO THE PHOTOS
AND SECTION DETAIL ON THIS SHEET FOR MORE DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
MATERIALS IN THE FIELD AND REPORT ANY DISCREPANCIES
TO THE COR.
3. THE CONTRACTOR SHALL COORDINTE WITH COR FOR HOURS
OF DEMOLITION
4. THE CONTRACTOR DEMOLISHES AND REMOVES ELECTRICAL
COMPONENTS THAT ARE NO LONGER REQUIRED. THE
CONTRACTOR SHALL ROUTE CONDUCTORS BACK TO THE
NEAREST JUNCTION BOX. REMOVE CONDUCTORS AND
CONDUITS AS REQUIRED.
5. THE CONTRACTOR IS TO COORDINATE WITH COR REGARDING
EXISTING FURNITURE BEFORE DEMOLITION BEGINS.
FURNITURE SHALL EITHER BE RETURNED TO VA OR DISPOSED
OF BY THE CONTRACTOR AT THE DIRECTION OF THE COR.
6. REFER TO PD201, PD202, AND PD203 FOR PLUMBING
DEMOLITION.
23 22 21 20 19 18
E.5
F
COURTYARD #3
E
SOFFIT ABOVE
SOFFIT ABOVE
2 2 2
DEMOLITION PLAN LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
BOUNDARY OF DEMOLITION
TRENCH DRAIN TO BE DEMOLISHED
AREA DRAIN TO BE DEMOLISHED
KEY PLAN
3 4
1 1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AD102
DEMOLITION PLAN - COURTYARD
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
N
1/8" = 1'-0"
DEMOLITION PLAN - COURTYARD 3
DEMOLITION KEYNOTES...
KEY VALUE KEYNOTE TEXT
1 EXISTING PAVING INCLUDING MULCH AND RIVER
ROCK REMOVED. SEE SECTIONAL DETAIL FOR
DEMOLITION.
2 EXISTING PLANTERS REMOVED. PATCH AND
REPAIR DAMAGED PORTION OF WALL TO MATCH
EXISTING AFTER DEMOLITION.
3 EXISTING STAIRS AND RAMPS REMOVED. PATCH
AND REPAIR DAMAGED PORTION OF WALL TO
MATCH EXISTING AFTER DEMOLITION.
4 EXISTING CANOPY REMOVED. PATCH AND
REPAIR DAMAGED PORTION OF WALL TO MATCH
EXISTING AFTER DEMOLITION.
5 EXISTING ELECTRICAL COMPONENTS REMOVED.
6 EXISTING BOLLARD W/ CARD READER TO
DEMOLITION PLAN LEGEND:
EXISTING TO BE DEMOLISHED
EXISTING TO REMAIN
BOUNDARY OF DEMOLITION
TRENCH DRAIN TO BE DEMOLISHED
AREA DRAIN TO BE DEMOLISHED
GENERAL NOTES:
1. REMOVE ALL LANDSCAPE IMPROVEMENTS AND ROOFING
SYSTEMS EXCEPT ROOF STRUCTURE. REFER TO THE PHOTOS
AND SECTION DETAIL ON THIS SHEET FOR MORE DETAILS.
2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
MATERIALS IN THE FIELD AND REPORT ANY DISCREPANCIES
TO THE COR.
3. THE CONTRACTOR SHALL COORDINTE WITH COR FOR HOURS
OF DEMOLITION
4. THE CONTRACTOR DEMOLISHES AND REMOVES ELECTRICAL
COMPONENTS THAT ARE NO LONGER REQUIRED. THE
CONTRACTOR SHALL ROUTE CONDUCTORS BACK TO THE
NEAREST JUNCTION BOX. REMOVE CONDUCTORS AND
CONDUITS AS REQUIRED.
5. THE CONTRACTOR IS TO COORDINATE WITH COR REGARDING
EXISTING FURNITURE BEFORE DEMOLITION BEGINS.
FURNITURE SHALL EITHER BE RETURNED TO VA OR DISPOSED
OF BY THE CONTRACTOR AT THE DIRECTION OF THE COR.
6. REFER TO PD201, PD202, AND PD203 FOR PLUMBING
DEMOLITION.
111213141516
E.5
F
COURTYARD #4
E
SOFFIT ABOVE
SOFFIT ABOVE
EXIT LIGHT TO REMOVED AND
RELOCATE UNDER NEW CANOPY
KEY PLAN
3 4
3 5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AD103
DEMOLITION PLAN - COURTYARD
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
N
1/8" = 1'-0"
DEMOLITION PLAN - COURTYARD 4
DEMOLITION KEYNOTES...
KEY VALUE KEYNOTE TEXT
1 EXISTING PAVING INCLUDING MULCH AND RIVER
ROCK REMOVED. SEE SECTIONAL DETAIL FOR
DEMOLITION.
2 EXISTING PLANTERS REMOVED. PATCH AND
REPAIR DAMAGED PORTION OF WALL TO MATCH
EXISTING AFTER DEMOLITION.
3 EXISTING STAIRS AND RAMPS REMOVED. PATCH
AND REPAIR DAMAGED PORTION OF WALL TO
MATCH EXISTING AFTER DEMOLITION.
4 EXISTING CANOPY REMOVED. PATCH AND
REPAIR DAMAGED PORTION OF WALL TO MATCH
EXISTING AFTER DEMOLITION.
5 EXISTING ELECTRICAL COMPONENTS REMOVED.
6 EXISTING BOLLARD W/ CARD READER TO
25.5
25.5
8.5
8.5
CC
DD
C.5C.5
D.5D.5
E.5E.5
FF
GG
25.4
25.4
F.5F.5
JJ
HH
G.5G.5
J.5J.5
H.5H.5
KK
LL
MM
NN
K.5K.5
L.5L.5
M.5M.5
AS111
AS111
AS111
40'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 40'-6" 22'-6" 25'-4" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
'-6
'-6
'-6
'-6
'-6
'-6
'-0
'-6
'-6
5,960 SF
COURTYARD #4
CY02-4
6,020 SF
COURTYARD #3
CY02-3
4,022 SF
COURTYARD #1
CY02-1
EXIST. BLDG.
'-0
110'-6"
110'-6"
'-0
110'-6"
'-0
EE
AS122
AS122
AS122
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AS100
OVERALL COURTYARD PLAN -
LEVEL 2
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
3/64" = 1'-0"
OVERALL FLOOR PLAN - LEVEL 2
L
K.5
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
'-0
R
ID
G E
RIDGE
4,022 SF
COURTYARD #1
CY02-1
EXISTING BUILDING
AS401
S L O
P E
D
S L O
SLOPE
DN
AS300
S L O
S L O
SLOPE
DN
SLOPE
DN
SLOPE
DN
AS300
+6 1/2"
+0" TRENCH DRAIN
+6"
AS300
+2 1/2" TRENCH DRAIN W/
GRATE
-1/4" TRENCH DRAIN W/
GRATE - TYP.
+5 1/2"
AS300
+3"
1/4"
SLOPE
+5 1/2"
+0" TRENCH DRAIN
+0" TRENCH DRAIN
EXPANSION
JOINT
EXPANSION
JOINT
EXPANSION
JOINT
CANOPY
ABOVE - TYP.
S L O
S L O
-1/4" AREA DRAIN - TYP.
+4"
-1/4" AREA DRAIN - TYP.
+4"
-1/4" TRENCH DRAIN W/ GRATE
+4"+4"+4"
+3 1/2"
+4 1/2"
+2 1/2" TRENCH
DRAIN W/ GRATE
RIDGE +6"
23 22 21 20 19 18
E.5
F
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
6,020 SF
COURTYARD #3
CY02-3
SLOPE
DN
SLOPE
DN
S L O
SLOPE
DN
SLOPE
DN
S L O
SLOPE
DN
SLOPE
DN
S L O
AS301
AS301
AS301
AS301
S L O
S L O
S L O
S L O
S L O
S L O
S L O
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
RIDGE +6"
+4"+4"+3 1/2"+4"+4"
+4"+4"+4"+4"+4" +4"
TRENCH DRAIN
W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN
W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN
W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN W/ GRATE
-1/4" - TYP.
+3 1/2" +4"+3 1/2"
+3 1/2"
+3 1/2" +3 1/2"
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
DASHED LINE
INDICATES SOFFIT
ABOVE
DASHED LINE
INDICATES SOFFIT
ABOVE
AS141
EXPANSION
JOINT
EXPANSION
JOINT
TRENCH DRAIN
TRENCH DRAIN
W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN
W/ GRATE
+2-1/2" - TYP.
+0"
E
'-0
111213141516
E.5
F
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
5,960 SF
COURTYARD #4
CY02-4
AS302
SLOPE
DN
SLOPE
DN
S L O
SLOPE
DN
SLOPE
DN
S L O
SLOPE
DN
SLOPE
DN
S L O
S L O
S L O
S L O
S L O
S L O
S L O
S L O
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
SLOPE
DN
AS302
AS302
AS302
DASHED LINE
INDICATES SOFFIT
ABOVE
DASHED LINE
INDICATES SOFFIT
ABOVE
CANOPY
ABOVE
AS401
TYP
AS401
TYP
AS401
TYP
EXPANSION
JOINT
EXPANSION
JOINT
CANOPY
ABOVE
+4"+4"+3 1/2"+4"+4"
+4"+4"+4"+4"+4" +4"
TRENCH DRAIN
W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN W/ GRATE
-1/4" - TYP.
TRENCH DRAIN W/
GRATE
-1/4" - TYP.
+3 1/2" +4" +3 1/2" +3 1/2" +3 1/2"
TRENCH DRAIN W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN W/ GRATE
+2-1/2" - TYP.
+3 1/2"
1' -0
1' -0
TRENCH DRAIN W/ GRATE
+2-1/2" - TYP.
TRENCH DRAIN W/ GRATE
+2-1/2" - TYP.
E
'-0
RIDGE +6"
FLOOR PLAN LEGEND:
TRENCH DRAIN W/ GRATE
AREA DRAIN
GENERAL NOTES:
A. ALL AREA DRAINS 1 1/2" BELOW EXIST. FIN. FLOOR OF BLDG.
B. REPAIR ALL THE WALLS WHICH ARE CURRENTLY COVERED BY
PLANTER BEDS. REPAIRS TO MATCH ADJACENT WALL FINISHES.
+X" TOP OF CONC. OR DRAIN ABOVE F.F.
- X" TOP OF CONC. OR DRAIN BELOW F.F.
KEY PLAN
3 4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AS111
ENLARGED COURTYARD PLAN -
LEVEL 2
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 1
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 3
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 4
N
N N
L
K.5
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
'-0
4,022 SF
COURTYARD #1
CY02-1
EXISTING BUILDING
13'-9 1/2" 15'-9 1/4" 15'-9 1/4" 11'-1" 11'-1" 10'-2 3/4" 10'-3 1/4" 11'-2 1/2" 11'-3 1/2"
5' -8
/2
4'
-4
/4
4' -4
/4
4'
-4
/4
4' -4
/4
4'
-4
/2
4' -2
/4
4'
-2
4' -2
4'
-2
4' -2
3'
-9
23 22 21 20 19 18
E.5
F
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
6,020 SF
COURTYARD #3
CY02-3
E
'-0
10'-3" 10'-3" 11'-9" 11'-9 1/4" 11'-3" 12'-3" 10'-3" 10'-3" 11'-3" 11'-3 1/4"
5' -8
4'
-7
/4
4' -6
/4
4'
-7
4' -7
4'
-7
/4
4' -7
/2
4'
-7
/2
4' -7
/2
4'
-7
/2
4' -7
/2
3'
-6
111213141516
E.5
F
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
5,960 SF
COURTYARD #4
CY02-4
E
'-0
3' -6
4'
-7
/4
4' -7
/2
4'
-7
/2
4' -7
/2
4'
-7
/2
4' -7
/4
4'
-7
4' -7
4'
-6
/4
5' -1
/4
5'
-2
10'-2 7/8" 10'-3 1/8" 11'-8 7/8" 23'-0 1/8" 12'-3" 10'-2 7/8" 12'-3 1/8" 10'-3" 10'-3"
PAVING PATTERN PLAN LEGEND:
PAVING MATERIAL 1 (ARCHITECTURAL LIGHT GRAY COLORED CONCRETE - BROOM FINISH)
PAVING MATERIAL 4 (ARCHITECTURAL TAN COLORED CONCRETE - BROOM FINISH)
PAVING MATERIAL 2 (ARCHITECTURAL GRAY COLORED CONCRETE - BROOM FINISH)
PAVING MATERIAL 3 (ARCHITECTURAL CHARCOAL COLORED CONCRETE - BROOM FINISH)
GENERAL NOTES:
A. PATTERN TO BE CREATED BY 1/4" WIDE X 1" DEEP SAW CUT IN CONC. PAVING
B. ALL LINES FOR PAVEMENT DESIGN SHOWN ARE CONTROL JOINT U.N.O.
C. CONTRACTOR TO SUBMIT FOR APPROVAL SHOP DRAWINGS ILLUSTRATING AND DIMENSIONING
DESCRIPTION OF PROPOSED PROCESS & SEQUENCING TO ACHIEVE PROPOSED TEXTURES AND
COLORS.
FLOOR PLAN LEGEND:
TRENCH DRAIN
AREA DRAIN
KEY PLAN
3 4
BID OPTION:
CLIN 0001, BASE BID - CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SUPERVISION
AND TESTING FOR RENOVATING COURTYARDS 1, 3, & 4 AS DESCRIBED IN THE CONTRACT
DOCUMENTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AS121
CONCRETE PAVING PLAN
(CLIN-0001, BASE BID)
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 1 (PATTERN)
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 3 (PATTERN)
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 4 (PATTERN)
N
L
K.5
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
'-0
4,022 SF
COURTYARD #1
CY02-1
EXISTING BUILDING
CONTROL JOINT - TYP.
13'-9 1/2" 15'-9 1/4" 15'-9 1/4" 11'-1" 11'-1" 10'-2 3/4" 10'-3 1/4" 11'-2 1/2" 11'-3 1/2"
5' -8
/2
4'
-4
/4
4' -4
/4
4'
-4
/4
4' -4
/4
4'
-4
/2
4' -2
/4
4'
-2
4' -2
4'
-2
4' -2
3'
-9
23 22 21 20 19 18
E.5
F
E
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
6,020 SF
COURTYARD #3
CY02-3
'-0
CONTROL JOINT - TYP.
10'-3" 10'-3" 11'-9" 11'-9 1/4" 11'-3" 12'-3" 10'-3" 10'-3" 11'-3" 11'-3 1/4"
3' -6
4'
-7
/2
4' -7
/2
4'
-7
/2
4' -7
/2
4'
-7
/2
4' -7
/4
4'
-7
4' -7
4'
-6
/4
4' -7
/4
5'
-8
111213141516
E.5
F
E
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
112'-6"
'-0
'-0
5,960 SF
COURTYARD #4
CY02-4
'-0
CONTROL JOINT - TYP.
10'-3" 10'-3" 11'-9" 11'-9 1/4" 11'-3" 12'-3" 10'-3" 12'-3 1/4" 10'-3" 10'-3"
5' -2
5'
-1
/4
4' -6
/4
4'
-7
4' -7
4'
-7
/4
4' -7
/2
4'
-7
/2
4' -7
/2
4'
-7
/2
4' -7
/4
3'
-6
KEY PLAN
3 4
PAVING PATTERN PLAN LEGEND:
PAVING MATERIAL 2 (ARCHITECTURAL GRAY COLORED CONCRETE-BROOM FINISH)
GENERAL NOTES:
A. PATTERN TO BE CREATED BY 1/4" WIDE X 1" DEEP SAW CUT IN CONC. PAVING
B. ALL LINES FOR PAVEMENT DESIGN SHOWN ARE CONTROL JOINT U.N.O.
C. CONTRACTOR TO SUBMIT FOR APPROVAL SHOP DRAWINGS ILLUSTRATING AND
DIMENSIONING DESCRIPTION OF PROPOSED PROCESS & SEQUENCING TO ACHIEVE
PROPOSED TEXTURES AND COLORS.
BID OPTION
• CLIN 0002 - DEDUCTIVE ALTERNATE TO ELEMINATE COLOR / STANING AND PATTERN OF
CONCRETE.
FLOOR PLAN LEGEND:
TRENCH DRAIN
AREA DRAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AS122
CONCRETE PAVING PLAN
(CLIN-0002)
REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 1 (PAVING)
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 3 (PAVING)
1/8" = 1'-0"
ENLARGED COURTYARD PLAN - COURTYARD 4 (PAVING)
N
LEVEL 2
118' - 0"
23 22 21 20 19 18
2ND FL. PLATFORM
127' - 11"
LEVEL 4
154' - 0"
4TH FL. PLATFORM
163' - 11"
PENTH. FL.
172' - 0"
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
PENTH. 2 FL
186' - 9"
EXIST. RAILING - TYP.
TENSILE STRUCTURE
WITH PES/PVC - TYP.
DESIGN BY MANUF.
SEE GENERAL NOTE 1
23 22 21 20 19 18
K
L
K.5
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
'-0
'-0
TENSILE STRUCTURE
WITH PES/PVC - TYP.
DESIGN BY MANUF.
SEE GENERAL NOTE 1
10'-4 1/2"
4' -1
1/
4"
EXIST. RAILING
EXIST. RAILING
23 22 21 20 19 18
E.5
F
AS141
TENSILE STRUCTURE
WITH PES/PVC - TYP.
DESIGN BY MANUF.
EXIST. RAILING
EXIST. RAILING
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
'-0
'-0
E
111213141516
E.5
F
TENSILE STRUCTURE
WITH PES/PVC - TYP.
DESIGN BY MANUF.
EXIST. RAILING
EXIST. RAILING
22'-6" 22'-6" 22'-6" 22'-6" 22'-6"
'-0
'-0
E
GENERAL NOTES:
1. CONTRACTOR TO PROVIDE TENSILE SUPPORTED SHADING
STRUCTURE AS GENERALLY INDICATED HEREIN. SHADING DEVICE
SHALL CONSIST OF TENSILE CABLSE IN A GRID PATTERN
GERNERALLY FOLLOWING THE DIMENSIONS PROVIDED. EXACT
DIMENSIONS SHALL BE AS PROVIDED BY THE MANUFACTURER.
2. SHADING ELEMENTS SHALL BE PES/PVC MATERIAL EITHER LIGHT
BLUE OR LIGHT GREY IN COLOR. SHADING DEVICE SHALL BE
DESIGNED FOR EXTERIOR USAGE AND SHALL BE RESISTANT TO
WEATHERING. EXACT MATERIALS AND CONFIGURATION SHALL BE
AS PROVIDED BY THE MANUFACTURER.
3. SHADING DEVICE SHALL BE SECURED ON ALL SIDES TO EXISTING
STRUCTURE. METHOD OF ATTACHMENT SHALL BE PER
MANUFACTURER'S RECOMMENDATION.
4. BEFORE CONTRACTOR OBTAINS OR INSTALLS SHADING DEVICE,
CONTRACTOR MUST PROVIDE COMPLETE SHOP DRAWINGS
FROM THE MANUFACTURER TO THE COR FOR APPROVAL. SHOP
DRAWINGS MUST INCLUDE STRUCTURAL ENGINEERING DESIGN
WITH SEAL FOR METHOD OF ATTACHMENT TO EXISTING
STRUCTURE.
KEY PLAN
3 4
BID OPTION:
CLIN 0001, BASE BID - CONTRACTOR TO PROVIDE ALL LABOR,
MATERIALS, EQUIPMENT, SUPERVISION AND TESTING FOR
RENOVATING COURTYARDS 1, 3, & 4 AS DESCRIBED IN THE
CONTRACT DOCUMENTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AS141
SHADING DEVICE PLAN REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
1/8" = 1'-0"
BUILDING SECTION - TYP
1/8" = 1'-0"
SHADING PLAN - COURTYARD 1
1/8" = 1'-0"
SHADING PLAN - COURTYARD 3
1/8" = 1'-0"
SHADING PLAN - COURTYARD 4
N
AS201
8'-0"
9 1/4" 3" 3" 5'-5 1/2" 6" 9 1/4"
C.L. HANGER ROD
C.L. LOWER ANCHOR
TS 3 X 3 X 1/4" STEEL HANGER TUBE
WELDED TO PL 8" X 7" X 0.500
3" X 6" WIDE X 0.078 FLAT SOFFIT
EXTR. ALUM. INTERLOCKING
DECKING
EXTR. ALUM. 8" FASCIA
3/8" - 16 X 1 1/4" HEX HEAD
TRHREAD ROLLING SCREW
3/8"Ø MACHINE BOLT ASSEMBLY
2"Ø DRAIN HOLE FIELD LOCATE
& INSTALL DRAIN STUB
EXIST. EXTR. WALL
METAL DECK
4' -0
3/8" - 16 X 1 1/4" HEX
HEAD THREAD
ROLLING SCREW
2" X 3" X 0.25 SPACER
#12 - 24 5PT X 1 1/4"
DECKING TEK SCREW
EXTR. ALUM. 8" FASCIA
3" X 6" WIDE X 0.078 FLAT
SOFFIT EXTR. ALUM.
INTERLOCKING DECKING
1/2"Ø 24" THRU THREADED
ROD W/ WASHERS, NUTS &
3"Ø X 0.25 PLTD STEEL
BACKING PLATE
4"
EXIST. STOREFRONT & DOOR
EXIST. EXTR. WALL
FLASHING - PROVIDED BY MANUF.
SEALANT BY CANOPY INSTALLER
AS201
NEW EXIT SIGN - LIGHTED
SEALANT
EXIST. WALL
ALUM. COUNTER FLASHING
ALUM. FLASHING
ALUM. CANOPY
ALUM. CANOPY FRAME
SAW CUT JOINT
AS201
2" DIA. DRAIN HOLE
FIELD LOCATE &
INSTALL DRAIN STUB
EXTR. ALUM. 8" FASCIA
FLAT SOFFIT EXTR. ALUM.
INTERLOCKING DECKING
LINE OF EXIST. EXTR. WALL
EXIST. STOREFRONT
4' -0
8'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
AS201
CANOPY & DETAILS REPAIR & REMEDIATE
COURTYARDS 1,3, & 4
LOMA LINDA, CA
605-22-408
01/03/2023 KL CH
ISSUE FOR BID
01/03/2023
1" = 1'-0"
CANOPY DETAIL - PLAN
1" = 1'-0"
CANOPY DETAIL - SECTION
3" = 1'-0"
CANOPY DETAIL - ALUM. FLASHING
1" = 1'-0"
CANOPY DETAIL - CEILING PLAN
KL K.5
2ND FL. PLATFORM
127' - 11"
SLOPE DN
EXIST. METAL DECK EXIST. METAL DECKEXIST. STRUCTURAL
CONC. SLAB
EXIST. STRUCTURAL
CONC. SLAB ON MTL. DECK
EXIST. STRUCTURAL
CONC. SLAB ON MTL. DECK
CONC. PAVING ON 1/2"
WATERPROOFING
TRENCH DRAIN TRENCH DRAIN
SLOPE DN
6"
1/ 4"
1/ 4"
4,022 SF
COURTYARD #1
CY02-1
4'-2" 1'-6" 21'-11 1/2" 20'-10" 1'-6" 2'-3"
V A
R
IE
S
V A
R
IE
S
LEVEL 2
118' - 0"
KL K.5
2ND FL. PLATFORM
127' - 11"
4,022 SF
COURTYARD #1
CY02-1
SLOPE DN
EXIST. METAL DECK EXIST. METAL DECKEXIST. STRUCTURAL
CONC. SLAB
EXIST. STRUCTURAL
CONC. SLAB ON MTL. DECK
EXIST. STRUCTURAL
CONC. SLAB ON MTL. DECK
CONC. PAVING ON 1/2"
WATERPROOFING
TRENCH DRAIN TRENCH DRAIN
SLOPE DN
1/
2"
1/
2"
6"
4'-2" 1'-6" 21'-11 1/2" 20'-10" 1'-6" 2'-0"
V A
R
IE
S
V A
R
IE
S
LEVEL 2
118' - 0"
KL K.5
2ND FL. PLATFORM
127' - 11"
4,022 SF
COURTYARD #1
CY02-1
EXIST. METAL DECK EXIST. STRUCTURAL
CONC. SLAB
EXIST. STRUCTURAL
CONC. SLAB ON MTL. DECK
EXIST. STRUCTURAL
CONC. SLAB ON MTL. DECK
CONC. PAVING ON 1/2"
WATERPROOFING
SLOPE DN
TRENCH DRAIN TRENCH DRAIN
SLOPE DN
4'-2" 1'-6" 21'-11 1/2" 20'-10" 1'-6" 3'-8"
1/
2"
6"
1/
2"
LEVEL 2
118' - 0"
23 22 21 20 19 18
2ND FL. PLATFORM
127' - 11"
7'-9"7'-0"7'-9"6'-9"7'-0"6'-9"7'-7"7'-0"7'-7"7'-6"8"7'-2"7'-2"8"7'-2"7'-2"8"7'-2"
4,022 SF
COURTYARD #1
CY02-1
1/ 4" 2" 1/ 4" 2" 1/ 4" 3
1/ 2"
1/
2"
1/
2"
1/
2"
3"
1/ 4"
SLOPE DNSLOPE DN SLOPE DNSLOPE DN SLOPE DNSLOPE DN SLOPE DNSLOPE DN SLOPE DNSLOPE DNSLOPE DN SLOPE DN
EXIST. METAL DECK EXIST. STRUCTURAL
CONC. SLAB
CONC. PAVING ON 1/2"
WATERPROOFING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
APPROVING OFFICIAL:
COR, Mr. Brian Porter
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
O'Brien Engineering, Inc., Managing Partner
Carrollton, TX 75006
972-233-2288
2340 E. Trinity Mills Rd. Ste 220 www.obrieneng.com
A/E:
OEI - LBL Joint Venture LLC O'Brien Engineering, Inc., Carrollton, TX 75006
9…