This is a Bill of Materials for RFQ SSPR462939 outlining the complete procurement specification for a NETZSCH DIL 502 Expedis® Automatic Apparatus for Thermomechanical Analysis with SiC furnace and turbo pump system.

The bill of materials comprises 26 line items from NETZSCH Instruments North America, LLC, including the primary dilatometer unit (DIL 502 Expedis Select) with double measuring system, capable of measuring dimensional changes from -180°C to 1600°C with 1 nanometer resolution across a ±10,000 micrometer measuring range. Supporting hardware includes an air-cooled high-temperature SiC furnace, protective alumina tubes, furnace components (flange, return pipe, switch valve supplement), and a manual operation high vacuum pumping system with turbomolecular pump. Software deliverables encompass Proteus 9.x data acquisition software with ExpertMode interface and four software extensions: Auto-Evaluation (SW-EVDILTMA-OPTION), c-DTA analysis (SW-CDTA-OPTION), and Identify curve recognition database system (SW-IDENT-OPTION). Consumables and accessories include sample holder kits in both alumina and graphite configurations, calibration standards (Indium, Tin, Bismuth, Zinc, Aluminum, Silver, Gold, Nickel), reference materials with certificates, and accessories such as spacers and crucibles. Additional services include installation and commissioning by NETZSCH service engineer (with temperature range -180°C to 1600°C), UL/CSA field evaluation and certification per North American standards, operating instructions, instrument poster, and a one-year preventative maintenance agreement covering annual system calibration. The system requires a customer-provided computer meeting specified requirements (Intel Core i3 Gen 8 minimum, 8GB RAM minimum, Windows 10/11 64-bit Professional/Enterprise). Standard electrical design operates at 115V (±10%), single phase, 60 Hz. Freight charges are listed as a separate line item with domestic equivalent notation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item Country of Origin Commodity Code Manufacturer Quantity Part Number Description

NETZSCH

Instruments

North America, LLC

1 DIL502SEA22.000-00

Dilatometer DIL 402 Expedis Select with double measuring system. Maximum temperature range: -180 to 1600°C, depending on the selected furnace systems and cooling units. Horizontal double pushrod dilatometer for determination of dimensional changes as a function of temperature in double or differential mode on the basis of DIN EN 821, DIN 51045, ASTM E831 or ASTM E288. The basic unit is characterized by the following properties: - Two novel “NanoEye” optoelectronic sensors with unmatched resolution over the entire measuring range allow direct sequential measurement of samples of different lengths and with different expansion behavior at maximum precision.

- Automatic sample length measurement eliminates the need for additional measuring tools. - “MultiTouch” sample positioning function for reliable positioning of the sample independent of the user. - Constant and adjustable contact force – force is continuously measured and regulated – hence ideal for sensitive or very soft samples - Optional force modulation with variable wave shapes (rectangular triangular, sinusoidal, steps, ramps and single pulse) with adjustable frequency. - Maintenance-free, friction-free measurement system design.

- color touch display for important functions for measurement and Calibration. - colored LED status bar with clear indication of the instrument status and measurement progress. - The dilatometer can be equipped with a mass flow controller for one gas path, optionally for three gas paths, and an additional channel for a wide variety of sample chamber conditions. - Vacuum-tight construction with integrated temperature control of measuring cell for reproducible results. - Furnace guidance, manually operated, to take up two furnace systems. - Optional Oxygen Trap System (OTS system) to absorb even the most minute residual traces of oxygen.

The DIL 502 Expedis Select in figures:

Accuracy of the automatic length measurement: 0.03 mm Resolution over the entire measuring range: 1 nm Measuring range: ± 10000 µm Sample length: 0 mm to 52 mm Sample diameter: 8 mm Force range: 10 mN to 3 N in 0.2-mN steps Temperature accuracy: 1 K Temperature precision: 0.1 K Temperature resolution: 0.001 K Temperature stability (isothermal): ± 0.02 K Gas atmospheres: Inert, oxidizing under static and dynamic conditions vacuum

NETZSCH

Instruments

North America, LLC

1 SW-9-DIL502SE

Proteus software 9.x for DIL 502 Expedis Select for data acquisition, storage and evaluation under MS WINDOWS with ExpertMode user interface. ExpertMode allows access to the complete software functionality, many settings and detailed help documentation. (Hardware requirements: up-to-date PC with MS Windows and printer per technical datasheet)

NETZSCH

Instruments

North America, LLC

1 SW-EVDILTMA-OPTION

Software extension for DIL and TMA instruments for Auto-Evaluation with three independent functions for "Metal Melting", "Glass Transition/Softening" and "Sintering Steps". The functions "Metal Melting" automatically evaluates the onset of the step in the dL signal occuring during melting of a metal sample. The function "Glass Transition/Softening" automatically evaluates the onset of a glass transition and the maximum of dL due to softening of a sample. The mean CTE (Coefficient of Thermal Expansion) values before and after the glass transition are furthermore evaluated. The function "Sintering Steps" automatically evaluates the dL steps occuring during sintering of a sample. After performing automatic evaluation, the results can be recalculated manually.

(Required: Latest basic software package of Proteus version 9.x)

NETZSCH Instruments North America, LLC., DIL 502 Select w/ SiC Furnace and Turbo Pump - DIL 502 Expedis® Automatic Apparatus for Thermomechanic Analysis with horizontal sample arrangement Temperature range according to the selected furnace consisting of:

Bill of Materials for RFQSSPR462939

NETZSCH

Instruments

North America, LLC

1 DIL40200A03.020-00 Furnace flange with manual screw cap for manually moved furnace guidance

NETZSCH

Instruments

North America, LLC

1 DIL5020A810.000-00

Air-cooled high-temperature tube furnace with exchangeable SiC heating element, prepared for exchangeable protective tube made of alumina or fused silica (for gas transit).

Very suitable for high temperature applications (e.g. technical ceramics, sintering processes, metals, etc.). For higher sample throughput, prepared for optional cooling device for rapid cooling.

sample temperature: RT to 1600°C furnace temperature: 1650°C control thermocouple: type S

NETZSCH

Instruments

North America, LLC

1 6.219.1-71.1.00 Protective tube of Al2O3, for gas flow, complete, with support flange, maximum temperature 1650°C

NETZSCH

Instruments

North America, LLC

1 DIL40200A84.080-00

Return pipe for the furnace gas outlet made of corrosion-resistant stainless steel for the vacuum-tight closure of the furnace – including valve, holder and hose connection to discharge gases or connect to an evacuation system.

For furnaces DIL5020A801.000-00; 802.000-00;803.000-00; 804.000-00;

805.000-00; 810.000-00; DIL40200A81.000-00; 82.000-00, 83.000-00;

84.000-00; 84.500-00 as well as DIL402G0A81.000-00, 82.000-00, 83.000-00, 84.000-00 6.219.1-21.0.00 and -23.0.00 (from 2007) 6.219.1-26.0.00, 6.219.6-21.0.00 and -23.0.00 (from 2007) and 6.219.6-26.0.00

NETZSCH

Instruments

North America, LLC

1 DIL40200A84.550-00

Switch valve supplement (24V DC) for fast cooling using compressed air, inlet pressure 1.5 bar max. absolute (0.5 bar overpessuress) for furnaces DIL5020A810.000-00 and DIL40200A84.500-00 Precondition: filtered, pure and oilfree air.

NETZSCH

Instruments

North America, LLC

2 DIL40200A61.000-00

Double tube design sample holder kit of Al2O3, for sample lengths 0 ...

52 mm and sample diameters up to 8 mm, with holding tube, 2 pushrods and sample thermocouple type S, includes a set of sample supports for samples Ø 4 mm, 6 mm and 8 mm, maximum temperature 1600°C

NETZSCH

Instruments

North America, LLC

2 6.219.1-92.7.00 Standard from high pure polycrystalline Al2O3, Ø 6 mm x 12 mm, with manufacturer's certificate (verified expansion values)

NETZSCH

Instruments

North America, LLC

1 DIL40200A15.030-00

MFC gas control block for installation inside the instrument, with 3 inputs and 2 outputs, for non-corrosive and non-explosive gases/gas mixtures, calibrated for N2, default conversion factors for O2, He, Ar, CO2 and synthetic air, other gases/gas mixtures on request, flow rate 5 ml/min up to 250 ml/min with a resolution of 1 ml/min with N2, for software-programmed control and registration of the gas flows This MFC is only suitable for factory-installation in a new device.

Instruments

North America, LLC

1 DIL50200A15.060-00

Additional MFC gas flow control block for installation in the basic system, to complement an existing MFC, with an input and an output to the purge gas line, possibility to use the gas outside the device and flow through an external component. For non-corrosive and non-explosive gases/gas mixtures, calibrated for N2, default conversion factors for O2, He, Ar, CO2 and synthetic air, other gases/gas mixtures on request, flow rate 5 ml/min up to 250 ml/min with a resolution of 1 ml/min with N2, for software-programmed control and registration of the gas flow (useable with MFC types DIL40200A15.030-00 and DIL40200A15.010-00)

NETZSCH

Instruments

North America, LLC

1 DIL40200A43.000-00

High vacuum pumping system for manual operation turbomolecular pump (30 l/s), with mounted driving electronics, two-stage vane-type rotary pump for rough vacuum, with vacuum measuring tube (115/230 V, 50/60 Hz)

NETZSCH

Instruments

North America, LLC

1 TXTPOS002-PC

A computer will be provided by the customer. The PC requirements are:

- Intel Core i3 Gen. 8, Core i5 Gen. 11 recommended

- min. 8 GB RAM, 16 GB RAM recommended

- 50 GB free hard disk space, > 250 GB SSD recommended

- Screen resolution minimum 1280x1024, Full-HD recommended (1920x1080)

- 1 free USB 2.0 port Supported operating systems:

- Windows 10/11 64-bit Professional/Enterprise (Windows 10 as of version 1809 LTSC and higher) For accessories such as valve boxes, humidity generators, QMS, GC/MS or FTIR-devices additional interface connections may be required (typically USB)

NETZSCH

Instruments

North America, LLC

1 SW-CDTA-OPTION

Software extension c-DTA for Proteus.

Software extension c-DTA for TG/STA/DIL/TMA instruments for adding c-DTA evaluation Features:

- Calculation and graphic presentation of the c-DTA curve together with additional measuring curves (optional)

- Ability to evaluate onset-, peak-, inflection point, end temperature, area, automatic peak search

- Tabulated printout or ASCII file export of the c-DTA values

- Determination of single values of the c-DTA curve (Prerequisite: Proteus basic software version 9.x.)

Instruments

North America, LLC

1 SW-IDENT-OPTION

Software-Extension „Identify for Proteus The Software-Extension „Identify" is a Curve Recognition and Database System for Thermal Analysis (currently for signals of type DSC, TGA, c-DTA, Cp, dL/L0, and DMA). Automatic recognition and classification of the actual measurement curve based on a database search. Identify serves for example for material recognition and quality control. The results of Identify appear after only one click on the active curve. The database contains NETZSCH libraries with approximately 1400 entries from the fields ceramics/inorganics, metals and alloys, polymers, organics, food, cosmetics and pharmaceuticals as well as chemical elements The user may extend the database with own libraries containing own measurements and literature data. Users’ libraries can be stored for example in the computer network and shared with other users and extended simultaneously.

The active measurement curve can be superimposed with one or several selectable database entries. By means of an alphabetical search filter, database entries can be searched. Database curves can be restored and edited. Filtering is furthermore possible with respect to measurement conditions or the existence of caloric effects.

A quality control (QC) functionality indicates if the actual measurement curve is – within user-defined thresholds - in agreement with selected database entries (QC: PASS!) or not (QC: FAIL!).

Algorithms for curve recognition are adjustable by the user by selecting an algorithm type and special algorithm parameters. Identify can either apply automatically suitable algorithm settings under consideration of the current measurement, or just apply the last-used algorithm settings.

The search temperature range can be selected by the user.

The results of Identify can be printed or exported in a file as a customizable report.

For each PC, the installation of one single instrument having the Identify option is sufficient to use it for other supported instruments.

Prerequisite: Most recent version of Proteus basic software, as of version 9.x and up

NETZSCH

Instruments

North America, LLC

1 6.223.5-91.3.30

Calibration sample kit with 8 substances 400 mg each (Indium, Tin, Bismuth with >10 ppm silver, Zinc, Aluminum, Silver, Gold, Nickel) for DSC/DTA calibration of enthalpy and temperature Temperature range ambient ... 1500°C, in wooden case with foam lining and certificate of compliance, for use in Al2O3 crucibles

NETZSCH

Instruments

North America, LLC

1 6.219.1-93.1.00

Crucible support from Al2O3 ( Ø 6 x 25 mm) and 5 crucibles from Al2O3 for cDTA® calibration Also required: DTA calibration kit 6.223.5-91.3.00 or 6.223.5-91.1.00 and SW-CDTA-69x.1B or SW-CDTA-80x.1B

NETZSCH

Instruments

North America, LLC

2 NGB800322 Spacer from Al2O3, Ø 8 x 0.63 mm thick

NETZSCH

Instruments

North America, LLC

1 AI-DIL502.01

Installation and commissioning of the instrument including basic instruction by a NETZSCH service engineer. Price is valid for DIL 502 Expedis with 1 furnace, temperature range from -180° to 1600°C.

Travelling and lodging costs depending on each country (included or not)

Instruments

North America, LLC

1 BA-DIL502-DIG Operating instructions DIL502 digital

NETZSCH

Instruments

North America, LLC

1 NGB828426 Instrument Poster DIL 502 Expedis

NETZSCH

Instruments

North America, LLC

1 UL-CSA

Field Evaluation and certification of the instrument according to US OSHA regulations (“UL” resp. “NRTL” certification) and/or according to Canadian SCC/CSA regulations. The instrument is prepared by the manufacturer to comply with North American standards and regulations.

The Field Evaluation is usually done at NETZSCH Instruments North America, LLC by an OSHA listed NRTL (Nationally Recognized Testing Laboratory) and/or Canadian SCC accredited CO/TO (Certification resp. Testing Organization) prior to the shipment to the customer. At discretion of NETZSCH and in agreement with the customer the Field Evaluation can alternatively be performed at the customer’s site in connection with the installation of the instrument. A respective certification label is applied to the instrument and the official Field Evaluation Report is provided to the customer.

NETZSCH

Instruments

North America, LLC

1 DIL40200A79.000-00

Double tube design sample holder kit of graphite, for sample lengths 0...52mm and sample diameter up to 8 mm max, with holding tube, 2 pushrods and sample thermocouple, sheathed, type D (W3%Re-W25%Re), sheath from molybdenum, includes a set of sample supports for samples Ø 4 mm, 6 mm and 8 mm, maximum temperature 2000°C

NETZSCH

Instruments

North America, LLC

1 PM-400

Netzsch PM Agreement (400 Series): covers one preventative maintenance visit per year, including system calibration. Maintenance agreements automatically renew annually on the anniversary date, unless cancelled prior to renewal. Renewal reminders will be sent 30 days prior to the contract anniversary date. Maintenance visits are scheduled based on Netzsch’s availability, with one visit during the 12 month contract term guaranteed.

26 ** ** ** 1 FREIGHT CHARGES FREIGHT CHARGES

- OR Domestic Equivalent -

Voltage/Frequency: 115V (± 10%) / 60 Hz - The standard electrical design of the instrument is for a line voltage of 115 V, single phase, 60 Hz.

Please note differing power requirements of some special items (e.g. power supply, cooling systems and sample preparation machines).