This document includes a solicitation for a 10 Gigabit Ethernet circuit between buildings in Portsmouth, New Hampshire and Philadelphia, Pennsylvania. Vendors are requested to provide, install, and maintain the circuit with a committed information rate of 10 Gigabits per second and availability of at least 99.5%. Quotes are due by July 20, 2020 and the selected vendor must pass a 72-hour soak test conducted by the Defense Information Systems Agency Global Operations Center at Scott Air Force Base in Illinois. The solicitation also includes technical requirements for the circuit such as maximum frame delay and jitter.

View the file

Other files

File Type Posted
HC101320QA811.v2.pdf PDF
Attachment C - Vendor Block Diagram Sample and Maps.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT B - HC101320QA811

TESTING REQUIREMENTS:

(A). VENDOR MUST PROVIDE LIGHT LEVEL READINGS (SIGNAL STRENGTH IN DBM) ON

EXTENSION FROM COMMERCIAL POP TO GOVERNMENT SERVICE DELIVERY POINT (SDP) AT

THE "A" AND "Z" LOCATION PRIOR TO CIRCUIT TURN OVER TO THE GOVERNMENT

ENSURING LEVELS ARE WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -3 TO -9 DBM.

(B). VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO

INSTALLATION AT THE "A" AND "Z" LOCATIONS.

(C). VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING AND

IMPLEMENTATION GROUP UPON RECEIPT OF A VALID ORDER TO ESTABLISH THE

COORDINATION AND ACTIVATION PROCESS. 618-418-8627

(D). PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST FROM THE

DROP SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN

THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THEIR OR LOCAL

EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE

"Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN THE

COMMERCIAL DEMARC AND THE GOVERNMENT'S SDP. VENDOR MUST ENSURE

TEST SETS ARE PLACED AT THE DROP SIDE AT THE "A" LOCATION AND AT

THE "Z" LOCATION. TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER

TO THE GOVERNMENT FOR ACCEPTANCE TESTING.

CIRCUIT SPECIFICATIONS:

1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) VENDOR PROVIDED 10G ETHERNET SIGNAL TO THE DISA ROUTERS.

- 10GIGABIT ETHERNET OVER OTN (OTU2), OTU2 CIRCUIT WILL CARRY

10GBE LAN PHY PAYLOAD, THE VENDOR WILL DEMONSTRATE THAT THE

PAYLOAD STRUCTURE IDENTIFIER (PSI) BYTE IN COLUMN 15, ROW 4 OF

THE OTU2 FRAME CAN TRANSPORT VALUE 0X09 BIDIRECTIONALLY ERROR

FREE.

- REFERENCE: PARA 17.4.1, ITU-T G.709/Y.1331 (06/2016) MAPPING

OF GFP FRAMES INTO AN EXTENDED OPU2 PAYLOAD AREA.

- 10GIGABIT ETHERNET - LAN PHY INTERFACE REQUIRED AT COMMERCIAL

DEMARC AT THE "A" AND "Z "LOCATIONS.

(B) FIBER TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL

HANDOFF-10GB ETHERNET-LAN-PHY-SINGLE MODE FIBER), 1310NM. "SC" OR

"LC" CONNECTORS AS DETERMINED BY SITE SURVEY. NOTE: WHEN

EXTENDED REACH OPTICS ARE USED THAT CHANGE THE TX/RX WAVELENGTH

OF THE OPTIC, THE VENDOR WILL NOTIFY THE GOVERNMENT 30 DAYS PRIOR

TO DELIVERY.

(C) COMMITTED INFORMATION RATE (CIR): 10GB

(D) ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM

TRANSMISSION UNIT (MTU) OF 9000 OCTETS (BYTES) JUMBO FRAMES.

(E) NO NETWORK INTERFACE UNIT, DEDICATED PATH.

(F) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS

IAW ITU-T.Y.1564 (02/2016) ETHERNET SERVICE ACTIVATION

- SIMPLE CIR VALIDATION TEST WITH EMIX PATTERN ADDFH. NOTE:

ETHERNET FRAME SIZE DESIGNATOR 'H' (PHYSICAL MTU) IS EQUAL TO

9000 BYTES.

(G) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24

HOURS A DAY, SEVEN DAYS PER WEEK, MONTHLY PERFORMANCE OF 99.5%

AVAILABILITY OR BETTER.

(H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECIEPT OF

TROUBLE.

(I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY

CIRCUIT OUTAGES.

(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.

(K) TELECOMM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE ADMINISTRATION

MONITORING OF ETHERNET CIRCUIT.

MINIMUM TECHNICAL SPECIFICATIONS

SPECIFIC FORMAT TO BE USED IS:

LINE RATE: 10.3125 GIGABITS/S, +- 100 PPM

LINE CODE: OPTIC

1. TEST AND ACCEPTANCE: CIRCUITS SHALL PASS A FULLY

DOCUMENTED SATISFACTORY 72 HOUR SOAK TEST BY DISA GOC AT

SCOTT AFB, IL. PRIMARY: (C) 618-418-8627 (D) 418-8627.

2. ERROR PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN

THE FOLLOWING PARAMETER THRESHOLDS TO BE ACCEPTABLE:

AVAILABILITY SHALL BE GREATER THAN 99.5% OR BETTER.

FRAME LOSS SHALL BE EQUAL TO ZERO WHEN TESTING AT 10 GIGABIT

HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564 STANDARDS.

3. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL

BE GREATER THAN 24 HOURS.

4. ROUND TRIP DELAY (RTD): RTD SHALL BE MEASURED OVER THE

10GB CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 10

MILLISECONDS PER 350 MILES MEASURED AS THE GREAT CIRCLE

DISTANCE BETWEEN THE "A" AND "Z" LOCATIONS.

5. ROUND TRIP DELAY VARIANCE (JITTER) SHALL BE NO MORE THAN

3MS.