This document is an Attachment B Salient Characteristics specification for a Visionix Retinomax K+5 or Equivalent autorefractor and keratometer. The Department of Veterans Affairs (VA) is seeking to procure two units through a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside solicitation under NAICS code 339112. The medical device must be an FDA-registered, handheld, portable autorefractor capable of taking measurements on patients in various positions, with specific technical requirements including a rechargeable battery, LCD display, and measurement capabilities for refractive errors ranging from -20.00 to +20.00 diopters, with cylinder ranges up to +/- 10 diopters and a minimal pupil size measurement of 3.0mm. The solicitation (36C26225Q1358) will result in a single Firm-Fixed Price (FFP) award and is being conducted using simplified acquisition procedures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26225Q1358_1.docx | DOCX document | |
| Copy of Attachment A - 36C26225Q1358 Visionix Rentinomax Brand Name or Equivalent.xlsx | XLSX spreadsheet | |
| 36C26225Q1358.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Visionix Retinomax K+5 or Equivalent
a) The unit must be an FDA registered autorefractor (refractometer) and keratometer. *An autorefractor is a portable medical device used to accurately measure an individual's refractive error, which is the basis for glasses or contact lens prescriptions. *A keratometer (ophthalmometer), is an instrument used to measure the curvature of the cornea that assists with fitting contact lenses.
· Unit must offer refractive and keratotomy evaluations
· Unit must be handheld and portable.
· Unit must be capable of taking measurements on a patient who is partially or fully reclined (supine)
· Unit must function on a rechargeable battery and have an LCD display.
· Unit must offer autorefraction in plus or minus cylinder format with a range on spherical component -20.00 diopters to +20.00 diopters, cylinder range up to +/-10 diopters
· Unit must offer autokeratometry with range up to +/- 10 diopters
· Unit must provide a minimal pupil size measurement of 3.0mm
· Unit must offer astigmatism detection. *A condition where the eye is not perfectly round.