This is an attachment document outlining the salient characteristics for a Request for Quotation (RFQ) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22. The solicitation number 36C26226Q0836 seeks a contractor to supply a Siemens MAGNETOM Vida/Vida Fit MRI System or equivalent equipment for use by the Radiology Department to detect irregularities and potential life-threatening conditions in areas such as the central nervous system and cardiac system. This is a combined synopsis/solicitation for commercial items under FAR Part 13 Simplified Acquisition Procedures, with the Government intending to award a single Firm-Fixed Price contract through an SDVOSB set-aside to businesses meeting NAICS Code 334510 with a size standard of 1,250 employees.
The solicitation requires offeror quotations to demonstrate compliance with the salient physical, functional, or performance characteristics specified in the attachment; failure to meet these specifications will result in the submission being deemed non-responsive. The technical specifications are listed on a Brand Name or Equal basis per FAR 52.211-6, with the provided information intended to be descriptive rather than restrictive, indicating the quality level that will be satisfactory. Attachment A contains the schedule listing line-item numbers, items, quantities, and units of measure. Offerors bear full responsibility for ensuring their submissions demonstrate compliance with all specified requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26226Q0836.docx | DOCX document | |
| Attachment A - Siemens MAGNETOM Vida Vida MRI Brand Name or Equal.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT A – SALIENT CHARACTERISTICS
The Siemens MAGNETOM Vida/Vida Fit MRI System OR EQUIVALENT
· Must have PCASL #BM
· Vendor must have Arterial Spin Labeling 3D
· Must have Shoulder Shape 16 #Vi Coil
· Must have Hand/Wrist 16 #Sk Coil
· Must have Foot/Ankle 16 #Sk Coil
· Must have myExam LiverLab Assist workflow module
· Must have all system hardware and software included in the OEM MRI configuration
· OEM manuals, guides, cleaning instructions
| Qty |
| Part No. |
| Item Description |
| 1 |
| 14461562 |
| PCASL #BM |
Blood labeling technique Pseudo Continuous Arterial Spin Labeling (PCASL).
| 1 |
| 14482844 |
| Arterial Spin Labeling 3D |
ASL is a non-contrast-enhanced brain perfusion technique. A 3D volume is acquired with high SNR by using a turbo gradient spin echo technique and an ASL preparation module to achieve clinically feasible scan times.
3D ASL provides generation of relative CBF maps. For multi-TI experiments bolus arrival time maps can be generated.
| 1 |
| 14456221 |
| Shoulder Shape 16 #Vi |
The Shoulder Shape 16 combines the known benefits of Tim 4G coil technology with new highly flexible materials, resulting in unmatched image quality, high patient comfort and easy handling. The Shoulder Shape 16 for examinations of the left or right shoulder consists of an iPAT-compatible 16-channel shoulder coil in a flexible shoulder cup that can be shaped around small and large shoulders. An L-shaped cushion for easy positioning of the patient is included. The 16-element coil with 16 integrated pre-amplifiers ensures maximum signal-to-noise ratio. Shoulder Shape 16 will be connected via a SlideConnect plug for fast and easy coil set-up and patient preparation.
| 1 |
| 14418513 |
| Hand/Wrist 16 #Sk |
The new Tim 4G coil technology with Dual Density Signal Transfer and SlideConnect Technology combines key imaging benefits: excellent image quality, high patient comfort, and unmatched flexibility.
Hand/Wrist 16 for examinations of the left or right hand and wrist region consists of a base plate and an iPAT compatible 16-channel coil and allows high-resolution imaging of the wrist and the hand within one examination. Hand/Wrist 16 will be connected via a SlideConnect plug for fast and easy patient preparation.
| 1 |
| 14418514 |
| Foot/Ankle 16 #Sk |
The new Tim 4G coil technology with Dual Density Signal Transfer and DirectConnect Technology combines key imaging benefits: excellent image quality, high patient comfort, and unmatched flexibility.
Foot/Ankle 16 for examinations of the left or right foot and ankle region consists of a base plate and an iPAT compatible 16-channel coil and allows high-resolution imaging of the foot and ankle within one examination. Foot/Ankle 16 is a cable-less coil and will be connected via DirectConnect for fast and easy patient preparation.
| 1 |
| 14475452 |
| myExam LiverLab Assist |
myExam LiverLab Assist is a system guided workflow to examine the hepatic fat and iron status.
| 1 |
| 14409110 |
| Arterial Spin Labeling 2D |
ASL is a non-contrast-enhanced brain perfusion technique. EPI sequence enhanced for ASL (Arterial Spin Labeling) with preparation module (inversion pulse, saturation pulses) and selectable prospective motion correction. Perfusion-weighted color maps and relative cerebral blood flow (relCBF) color maps are calculated with Inline technology.