Attachment B - Salient Characteristics

SPECIFICATIONS

DESCRIPTION SPECIFICATION

Load Capacity1

Lift Back Tilt Foot (footrest fully extended) Foot (footrest retracted)

725 lb (328.9 kg) 400 lb (181.4 kg) 725 lb (328.9 kg) 150 lb (68 kg) 200 lb (90.7 kg)

Weight of Chair2

550 Standard Base 550 Swivel Base 550 Mobile Base

308 lb (139.7 kg) 370 lb (167.8 kg) 301 lb (136.5 kg)

Shipping Weight of Chair3

550 Standard Base 550 Swivel Base 550 Mobile Base

363 lb (164.7 kg) 428 lb (194.1 kg) 359 lb (162.8 kg)

Shipping Weight of Upholstery Kit 550 Seamless/Designer Upholstery Kit 33 lb (15 kg)

Table Top Range 550 Standard Base 550 Swivel Base and Mobile Base

18.75-39 in (47.6-99 cm) 18.75-37 in (47.6-94 cm)

Back Section Range 0°± 2.2° (horizontal) to 85°± 2.2°

Table Top Tilt Range 0° ± .6° to 30°± .6° Range is limited when back section is at or lower than 20° below horizontal to avoid collision.

Foot Section Range 0° ± 2.2° (horizontal) to 90°± 2.2°

Foot Extension Range 7 in (17.78 cm) Range is limited depending on Tilt angle, Lift, and footrest angle.

Foot Control IPX6 Rated

Hand Control IPX6 Rated

General Dimensions (w/headrest & footrest fully extended) 25 in (63.5 cm) wide (does not include arms) x 80 in (203.2 cm) long

Power Cord Plugs: U.S.A. standard 3 prong and IEC 60320-C13 (self-retaining)

Electrical Ratings 100-240VAC (47-63 Hz); 7 Amps

Fuse Replacement (2) 5mm x 20mm 4 Amp 250V Time-Delay Glass Tube Type Fuse

Duty Cycle Intermittent Operation, 10% Duty Cycle Example: (1) minute on (9) minutes off

Classification Class 1, Type B Applied Part, Ordinary Equipment, Intermittent Operation donovan.conley Highlight donovan.conley Highlight donovan.conley Highlight donovan.conley Highlight donovan.conley Highlight donovan.conley Highlight

SPECIFICATIONS

DESCRIPTION SPECIFICATION

Listing/Approvals ETL, IEC 60601-1:2005 Ed.3+A1;C1:2014

AAMI ES60601-1:2005+A1

CSA C22.2#60601-1:2014 Ed.3 IEC 60601-1-2:2014 Ed.4

1Load Capacity will vary depending on placement and distribution of load on the section of the chair.

2Weight may vary due to product variation.

3Weight may vary due to variation in weight of shipping materials.