PRODUCT DESCRIPTION

For

NON-EXPENDABLE EQUIPMENT

GE Healthcare MAC VU360 Brand Name or Equal Electrocardiographs

Prepared By:

Strategic Acquisition Center Department of Veterans Affairs 10300 Spotsylvania Avenue, Suite 400 Fredericksburg, VA 22408

1. SCOPE OF WORK:

The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Electrocardiograph product line as a candidate for a VA-wide (otherwise referred to as “national”) Requirements contract award.

Electrocardiographs (also called 12-lead ECG or EKG machines) are used to detect the electrical signals associated with cardiac activity by means of electrodes positioned on the skin. These instruments include a computerized unit that can process the average of the ECG signals, compare those signals with an internal algorithm, and print out the ECG along with an interpretation that can be used as an auxiliary tool by the cardiologist. Further, Electrocardiographs are used to diagnose cardiac abnormalities, determine a patient's response to drug therapy, and reveal trends or changes in heart function. Electrocardiographs differ from ECG monitors, which provide a continuous real-time display of the ECG waveform and other physiologic measurements on a screen and warn of potentially life-threatening or precursor rhythms.

The Vendor must demonstrate the ability to meet all requirements of the solicitation. The objective is to provide Electrocardiographs to be used by clinicians throughout the VA medical centers and facilities.

2. REQUIREMENT

This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” which requires the vendor indicate that each product being offered is an “equal” product to the GE MAC VU360 Electrocardiograph. For each equal product, the vendor must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The vendor must also clearly identify the item by brand name (if any) and make/model number. Finally, the vendor must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer, and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.

CLIN
Manufacture
Part Number
Description
0001
GE
2030360-021
MAC VU360 US GOV 15-LEAD ECG, 12SL, LAN (includes 0001AA – 0001AH)
0001AA
GE
2030360-001
MAC VU360 Configuration – Identifies the configuration
0001AB
GE
2030360-723
MAC VU360 CAM AHA W/Leadwires, mounting arm/bracket
0001AC
GE
2030360-027
MAC VU360 English Language
0001AD
GE
2030360-15
MAC VU360 North American Power Cord
0001AE
GE
60Hz
60Hx AC Filter
0001AF
GE
Set-Letter
Letter Paper Setting for Mac VU360
0001AG
GE
2108406-207
United States (USA) (Identifies country of origin)
0001AH
GE
2030360-110
MAC VU360 Edelivery Software Entitlement
0002
GE
2030360-039
MAC VU360 USGOV FIPS Wireless A/B/G/N
0003
GE
2030360-040
MAC VU360 ACS/Critical values - records a resting ECG with ACS interpretation statement and displays critical value notifications in the order in which they are detected.
0004
GE
2030360-043
MAC VU360 External Barcode w/Mounting HW - Integral barcode scanner used to enter patient data
0005
GE
2086800-001
MAC VU360 Easy Clean Trolley, height adjustable with rear/front bins
0006
GE
2091358-001
ECG WIFI - LAN GE Install and Configuration per cart charge (includes 0006AA)
0006AA
GE
Install Carts
Installation of resting ECG System
0007
GE
2036984-001
BTRY FLEX-3S3P 11.1V 18650 LI-ION SMBUS
0008
GE
CE2018410-001
Clinical Education training for healthcare facilities with less than or equal to carts. This package includes Pre-Work Videos, 2 Days of Onsite Training, 1, 30-minute remote training follow up session. This package does not include Pre-Workflow Analysis.
0009
GE
2091358-002
Advanced wireless network support (802.1X Authentication/PEAP/TTLS)

The Department of Veterans Affairs (VA) is seeking vendors who can provide the GE MAC VU360 Electrocardiograph and associated equipment as listed above or equal commodities which meet all of the following salient characteristics (SC):

CLIN 0001

Part Number 2030360-021 MAC VU360 US GOV 15-LEAD ECG, 12SL, LAN (includes 0001AA – 0001AH)

SC
Salient Characteristics
Method of Evaluation
Location in Literature
1
Shall have a 10” minimum LCD/LED display screen
Literature
2
Shall have an alphanumeric keyboard
Literature
3
Shall have a Gain/Sensitivity setting of at least 5, 10, or 20mm/mV.
Literature
4
Shall offer an integral bar-code scanner for entering patient data.
Literature
5
Shall have a minimum internal storage capacity of 200 ECG waveforms
Literature
6
Shall have a printer supporting Z-fold thermal paper with perforations and grid.
Literature
7
Shall have pacemaker detection capabilities.
Literature
8
Shall be capable of 12 or 15-lead ECG acquisition.
Literature
9
Shall have an AC or rechargeable battery power supply.
Literature
10
Shall have an algorithm for ECG interpretation which includes gender-specific criteria.
Literature
11
Shall have lead hook-up confirmation capability.
Literature
12
Shall offer the integral MUSE™ Cardiology Information System.
Literature
13
Shall offer the capability to transmit data using FIPS LAN or wireless LAN network.
Literature
14
Shall offer an integral cart/trolley to enable unit portability.
Literature