Attachment B - MAGNETOM Components Salient Characteristics.docx

DOCX document 22 KB Posted

Attached to
6525--SIEMENS MAGNETOM SOFTWARE & COMPONENTS AMENDMENT 0002
Solicitation number
36C26226Q1082
Issued by

About this file

This is an attachment detailing salient characteristics for Siemens MAGNETOM Vida/Vida Fit MRI system components and software being procured by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 under solicitation number 36C26226Q1082. The procurement is structured as a combined synopsis/solicitation and Request for Quotation (RFQ) under FAR Part 13 Simplified Acquisition Procedures, with the government intending to award a single firm-fixed-price contract to a qualified NAICS 334510 business with fewer than 1,250 employees through full and open competition.

The required components include specific Siemens OEM hardware and software modules for the existing 3T MRI system used for clinical and research purposes by the Radiology Department. Key items specified include the myExam LiverLab Assist workflow module (mandatory), Pseudo Continuous Arterial Spin Labeling (PCASL) technique software, 2D and 3D Arterial Spin Labeling (ASL) brain perfusion imaging capabilities, and multiple flexible receiver coils including Shoulder Shape 16, Hand/Wrist 16, and Foot/Ankle 16 coils featuring Tim 4G technology and SlideConnect/DirectConnect connection systems. All components must include OEM manuals, guides, and cleaning instructions, with system hardware and software included in the complete OEM MRI configuration. Offerors must demonstrate that quotations meet the specified physical, functional, and performance characteristics outlined in the attachment; any responses failing to meet these requirements will be considered non-responsive.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT B - Salient Characteristics

The Siemens MAGNETOM Vida/Vida Fit MRI System Components

· Must have myExam LiverLab Assist workflow module

· Must have all system hardware and software included in the OEM MRI configuration

· OEM manuals, guides, cleaning instructions

Qty
Part No.
Item Description
1
14461562
PCASL #BM

Blood labeling technique Pseudo Continuous Arterial Spin Labeling (PCASL).

1
14482844
Arterial Spin Labeling 3D

ASL is a non-contrast-enhanced brain perfusion technique. A 3D volume is acquired with high SNR by using a turbo gradient spin echo technique and an ASL preparation module to achieve clinically feasible scan times.

3D ASL provides generation of relative CBF maps. For multi-TI experiments bolus arrival time maps can be generated.

1
14456221
Shoulder Shape 16 #Vi

The Shoulder Shape 16 combines the known benefits of Tim 4G coil technology with new highly flexible materials, resulting in unmatched image quality, high patient comfort and easy handling. The Shoulder Shape 16 for examinations of the left or right shoulder consists of an iPAT-compatible 16-channel shoulder coil in a flexible shoulder cup that can be shaped around small and large shoulders. An L-shaped cushion for easy positioning of the patient is included. The 16-element coil with 16 integrated pre-amplifiers ensures maximum signal-to-noise ratio. Shoulder Shape 16 will be connected via a SlideConnect plug for fast and easy coil set-up and patient preparation.

1
14418513
Hand/Wrist 16 #Sk

The new Tim 4G coil technology with Dual Density Signal Transfer and SlideConnect Technology combines key imaging benefits: excellent image quality, high patient comfort, and unmatched flexibility.

Hand/Wrist 16 for examinations of the left or right hand and wrist region consists of a base plate and an iPAT compatible 16-channel coil and allows high-resolution imaging of the wrist and the hand within one examination. Hand/Wrist 16 will be connected via a SlideConnect plug for fast and easy patient preparation.

1
14418514
Foot/Ankle 16 #Sk

The new Tim 4G coil technology with Dual Density Signal Transfer and DirectConnect Technology combines key imaging benefits: excellent image quality, high patient comfort, and unmatched flexibility.

Foot/Ankle 16 for examinations of the left or right foot and ankle region consists of a base plate and an iPAT compatible 16-channel coil and allows high-resolution imaging of the foot and ankle within one examination. Foot/Ankle 16 is a cable-less coil and will be connected via DirectConnect for fast and easy patient preparation.

1
14475452
myExam LiverLab Assist

myExam LiverLab Assist is a system guided workflow to examine the hepatic fat and iron status.

1
14409110
Arterial Spin Labeling 2D

ASL is a non-contrast-enhanced brain perfusion technique. EPI sequence enhanced for ASL (Arterial Spin Labeling) with preparation module (inversion pulse, saturation pulses) and selectable prospective motion correction. Perfusion-weighted color maps and relative cerebral blood flow (relCBF) color maps are calculated with Inline technology.

File details come from the government source that posted it. Updated .