This document outlines a federal contract opportunity for infrastructure upgrades at the VA Greater Los Angeles Healthcare System's Los Angeles Ambulatory Care Center. The solicitation seeks general construction, alteration, mechanical, electrical and utility system upgrades to support deployment of the Department of Veterans Affairs' new Electronic Health Record Modernization system. Work will be performed in a functioning hospital and includes necessary demolition, removal of existing structures, and completion of other unspecified items. All work must comply with applicable local, VA and building codes. This opportunity is reserved exclusively for verified Service-Disabled Veteran-Owned Small Businesses and has a magnitude between $2-5 million. The North American Industry Classification code is 236220. The Department of Veterans Affairs will issue an invitation for bid on or about May 21, 2021 via sam.gov. A site visit will also be scheduled. Interested parties should contact the identified contracting specialist.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WELDED HOLLOW

METAL FRAME

DOOR - SEE

DOOR SCHED.

INSULATION

JAMB ANCHOR

INSERT CLIP

#16 GA. METAL STUD

(1) LAYER OF 5/8"

THK. TYPE `X' GYP. BD.

WELDED HOLLOW

METAL FRAME

DOOR - SEE

SCHEDULE

INSULATION

FULL HT.

#16 GA. METAL STUD

HEADER

(1) LAYER OF 5/8" THK.

TYPE `X' GYP. BD. ON

3'-0"

H E

I G

H T

T

O

M A

T C

H

E

X I S

T

2" 2"

DOOR

DOOR FRAME

(E) FLOORING

(N) TRANSITION STRIP

(N) VIYNL COMPOSITE TILE

SEE FIN. SCHE.

1A-41

EXAM ROOM

CORRESPONDING

GRADE II BRAILLE

FONT SIZE AND MATERIALS

TO MATCH EXISTING

B444A

TELECOM

ROOM

MATERIAL: TO MATCH EXISTING

DIMENSIONS: 0.3125"X9.0"X9.0"

COPY METHOD: ROOM NUMBERS: LASER CUT

ROOM ID: PLOTTER CUT VINYL

TYPE STYLE: HELVETICA MED. 1.00"

COLORS: TO MATCH EXISTING

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

DOOR SCHEDULE

REV

DOOR NO.

DOOR

DOOR

TYPE

DOOR MAT.

DOOR

FINISH

FRAME

MAT.

FRAME

TYPE

FRAME

FINISH

FIRE RATING HWSET DETAILS REMARKS

MARK

SIZE (W x H x THK.)

B444A 3'-0"X HT. MATCH EXISTING 1 SCW FF HM 1 FF HW1 1&2/AE601 PROVIDE CARD READER

SCALE: 3"= 1'-0"

DOOR JAMB

SCALE: 3"= 1'-0"

DOOR HEAD

ABBREVIATIONS:

FF

HM

SCW

FACTORY FINISH

HOLLOW METAL

SOLID CORE WOOD

DOOR TYPE 1

FRAME TYPE 1

SCALE: 3"= 1'-0"

TRANSITION STRIP (O-1)

SCALE: 3"= 1'-0"

ROOM IDENTIFICATION SIGNAGE

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

ARCHITECT/ENGINEERS/CONSULTANTS:

AutoCAD SHX Text Office of

AutoCAD SHX Text Facilities

AutoCAD SHX Text Management

AutoCAD SHX Text

EHRM INFRASTRUCTURE

AutoCAD SHX Text

UPGRADES

AutoCAD SHX Text

VA LAACC MEDICAL FACILITY

AutoCAD SHX Text 03-11-2021

AutoCAD SHX Text

691GE-20-202

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

RITA KALWANI

AutoCAD SHX Text F

AutoCAD SHX Text C

AutoCAD SHX Text

EXP. 3-31-2021

AutoCAD SHX Text No. C 14658

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text H

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text F

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text L

AutoCAD SHX Text H

AutoCAD SHX Text T

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text

RK

AutoCAD SHX Text

NC

AutoCAD SHX Text

DOOR SCHEDULE

AutoCAD SHX Text

AE601

AutoCAD SHX Text

PHARMACIST

B201

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

N

SCALE: 1/4"= 1'-0"

PARTIAL FIRST FLOOR FINISH PLAN A114 COMPUTER ROOM

F-1 (EXISTING RAISED FLOOR)

F-X

C-X

W-X

B-X

FLOOR FINISH

FLOOR BASE FINISH

WALL FINISH

CEILING FINISH

F-2 (NEW RESILIENT SHEET FLOORING)

N

SCALE: 1/4"= 1'-0"

PARTIAL FIRST FLOOR FINISH PLAN

B122 TR ROOM

F-2

B-1

COMPUTER ROOM

A114

TR ROOM

B122

N

SCALE: 1/4"= 1'-0"

PARTIAL SECOND FLOOR FINISH PLAN

B201 TR ROOM

TR ROOM

B201

TR ROOM

A312

F-2

F-2

N

SCALE: 1/4"= 1'-0"

PARTIAL THIRD FLOOR FINISH PLAN

A312 TR ROOM

SCALE: 1/4"= 1'-0"

PARTIAL FOURTH FLOOR FINISH PLAN

B444A TR ROOM

TR ROOM

B444A

F-2

N

SCALE: 1/4"= 1'-0"

PARTIAL FIFTH FLOOR FINISH PLAN

A502 TR ROOM

TR ROOM

A502

F-2

STORAGE

B444

F-3

INTERIOR FINISH SCHEDULE LEGEND

FLOOR

F-1 EXISTING RAISED

FLOOR

MANUFACTURER:

PRODUCT:

COLOR:

EXISTING

F-2

VIYNL COMPOSITE

TILE

MANUFACTURER:

PRODUCT:

COLOR:

AMRSTRONG

EXCELION SDT

ARMOR GRAY #51951

F-3 SOLID VIYNL FLOOR

TILE

MANUFACTURER:

PRODUCT:

COLOR:

ARMSTRONG

EXCELON IMPERIAL TEXTURE DIAMOND 10 TECH

TO MACTH EXISTING OR COOL WHITE #Z1899

BASE

B-1 RUBBER BASE

(SIZE: 4" HIGH)

MANUFACTURER:

PRODUCT:

COLOR:

MANNINGTON

BURKEBASE TYPE TP

TO MACTH EXISTING OR CREAM 205

WALL

W-1 FIELD PAINT MANUFACTURER:

COLOR:

DUNN EDWARDS

SWISS COFFEE DEW341 RL#008

CEILING

C-1 PAINTED GYP

BOARD

MANUFACTURER:

COLOR:

DUNN EDWARDS

SWISS COFFEE DEW341 RL#008

C-2 CLEAN ROOM VL ON

EXISTING GRID

MANUFACTURER:

COLOR:

AMRSTRONG

WHITE

C-3 ACOUSTICAL

CEILING TILE

MANUFACTURER:

PRODUCT:

COLOR:

GRID:

ARMSTRONG

ULTIMA

WHITE-ULTIMA TEGULAR FINE TEXTURE

24"x24"

OTHER

O-1 TRANSITION STRIP MANUFACTURER:

COLOR:

SCHLUTER

RENO-T- ALUMINUM

W-1

C-1

B-1

W-1

C-1

B-1

W-1

C-1

B-1

W-1

C-3

B-1

W-1

C-1

B-1

W-1

C-1

FINISH SCHEDULE

ROOM NO. ROOM NAME FLOOR BASE

WALLS

CEILING

CEILING

HEIGHTS

REMARKS

NORTH EAST SOUTH WEST

A114 COMPUTER ROOM F-1 EXISTING W-1 W-1 W-1 W-1 C-2 EXISTING

B122 TR ROOM F-2 B-1 W-1 W-1 W-1 W-1 C-1 MATCH EXIST.

B201 TR ROOM F-2 B-1 W-1 W-1 W-1 W-1 C-1 MATCH EXIST.

B263K TR ROOM EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING

A312 TR ROOM F-2 B-1 W-1 W-1 W-1 W-1 C-1 MATCH EXIST.

B444 STORAGE F-3 B-1 W-1 W-1 W-1 W-1 C-3 MATCH EXIST.

B444A TR ROOM F-2 B-1 W-1 W-1 W-1 W-1 C-1 MATCH EXIST.

A502 TR ROOM F-2 B-1 W-1 W-1 W-1 W-1 C-1 MATCH EXIST.

F-1

W-1

C-2

N

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN.

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231, OCT 1978

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

ARCHITECT/ENGINEERS/CONSULTANTS:

AutoCAD SHX Text Office of

AutoCAD SHX Text Facilities

AutoCAD SHX Text Management

AutoCAD SHX Text

EHRM INFRASTRUCTURE

AutoCAD SHX Text

UPGRADES

AutoCAD SHX Text

VA LAACC MEDICAL FACILITY

AutoCAD SHX Text 03-11-2021

AutoCAD SHX Text

691GE-20-202

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

RITA KALWANI

AutoCAD SHX Text F

AutoCAD SHX Text C

AutoCAD SHX Text

EXP. 3-31-2021

AutoCAD SHX Text No. C 14658

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text H

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text F

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text L

AutoCAD SHX Text H

AutoCAD SHX Text T

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text

RK

AutoCAD SHX Text

NC

AutoCAD SHX Text

FINISH PLANS AND SCHEDULES

AutoCAD SHX Text

AF101

1" 1" 12" MIN

MI

N

3" 11 2"

MI

N

21 4"

MIN 3 4" 3

4" MIN MIN 6"

5 8"

MI

N CONCRETE FILL

CONCRETE FILL

MI

N

11 2"

CONCRETE FILL

6"

UNISTRUT P1000

MIN 8" L

HILTI 2-3

8" Ø KB TZ

W/ MIN 2 IN EMBED

EMBED INTO CONC

(ICC-ESR-1917)

P1000

A A

A-A

GENERAL NOTES

ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO SPECIFICATIONS,

PLANS AND ALL GOVERNING ORDINANCES.

ALL WORK SHALL COMPLY WITH IBC 2018, VA H-18-8 SEISMIC DESIGN

REQUIREMENTS

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE

JOB PRIOR TO STARTING CONSTRUCTION AND THE CONTRACTING OFFICER,

ARCHITECT OR ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY

DISCREPANCIES OR INCONSISTENCIES. DO NOT SCALE DIMENSIONS, WHERE NO

DIMENSIONS ARE PROVIDED, CONSULT WITH CONTRACTING OFFICER FOR

CLARIFICATION BEFORE PROCEEDING WITH THE WORK.

ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS OR AND

CODE REQUIREMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN

EXPENSE AND AT NO EXPENSE TO THE GOVERNMENT OR THE CONTRACTING OFFICER.

IF CLARIFICATIONS ARE REQUIRED, THE CONTRACTOR SHALL SUBMIT A RFI AND CONTACT

VA PROJECT MANAGER AND CONTRACTING OFFICER PRIOR TO PROCEEDING WITH THE

WORK.

ALL SYMBOLS AND ABBREVIATIONS USED IN THE DRAWINGS ARE CONSIDERED

TO BE CONSTRUCTION STANDARDS. IF CLARIFICATIONS ARE REQUIRED, THE

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER PRIOR TO

PROCEEDING WITH THE WORK.

NO OPENINGS, POCKETS, NOTCHES, BLOCKOUTS, ETC. ARE ALLOWED IN

STRUCTURAL ELEMENTS UNLESS DETAILED ON THE STRUCTURAL DRAWINGS.

NOTIFY THE ARCHITECT OR ENGINEER OF RECORD OF ANY OPENINGS,

POCKETS, ETC. SHOWN BY OTHER DRAWINGS BUT NOT SHOWN ON THE

STRUCTURAL DRAWINGS.

THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT

THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES INCLUDE BUT NOT

LIMITED TO BRACING, SHORING, ETC. OBSERVATION VISITS TO THE SITE BY THE

CONTRACTING OFFICER, ARCHITECT, OR ENGINEER SHALL NOT INCLUDE THE

INSPECTION OF BRACING, SHORING, ETC.

CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IF PLACED ON FRAMED

FLOORS, ROOF, ETC. THE LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD OF

20 PSF (POUNDS PER SQUARE FOOT) UNLESS APROVED OTHERWISE BY

ENGINEER OF RECORD.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATION PROCEDURES

INCLUDING LAGGING, SHORING, AND PROTECTION OF ADJACENT PROPERTY,

STRUCTURES, STREET, AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL,

STATE AND LOCAL SAFETY ORDINANCES.

SEE MECHANICAL, ELECTRICAL AND/OR ARCHITECTURAL DRAWINGS FOR

LOCATION AND SIZE OF PIPE, VENT, DUCT, OTHER SIMILAR OPENINGS, AND

EMBEDDED OR ATTACHED ITEMS.

NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL

NOTES AND TYPICAL DETAILS.

DO NOT SCALE DRAWINGS.12.

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC

FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF

SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF

RESPONSIBILITY TO THE CONTRACTING OFFICER PRIOR TO THE

COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER IBC 2018

SEC 1704.4

13.

1. SPECIAL INSPECTION PER IBC 2018 CHAPTER 17 BY A PERSON WHOSE QUALIFICATIONS ARE ACCEPTABLE TO THE STRUCTURAL ENGINEER OF RECORD AND SHALL BE REQUIRED FOR THE FOLLOWING WORK:

A. POST INSTALLED ANCHORS WEDGE AND EPOXY ANCHORS.

3. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO DEMONSTRATES COMPETENCE TO THE SATISFACTION OF THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR THE DESIGN OF THE

THE STRUCTURE FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR

OPERATION REQUIRING SPECIAL INSPECTION.

4. DUTIES AND RESPONSIBILITIES OF THE SPECIAL INSPECTOR:

THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH:

A. THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE INSPECTOR SHALL NOT ALTER, MODIFY, ENLARGE, OR WAIVE ANY OF THE REQUIREMENTS OF THE DOCUMENTS.

5. WHERE SPECIAL INSPECTION REQUIREMENTS DUPLICATE THE REQUIREMENTS OF OTHER SPECIFIED

TESTING, DUPLICATE INSPECTIONS SHALL NOT BE REQUIRED

SPECIAL INSPECTION PER 2018 IBC

(N) NEW

(E) EXISTING

U.N.O. UNLESS NOTED OTHERWISE

TYP TYPICAL CONDITION

@ AT

W/ WITH

EQUIV EQUIVALENT

RM ROOM

Ø DIAMETER

CONN CONNECTION

PLATE

CLR CLEARCONT CONTINUOUS

FDN FOUNDATION

FTG FOOTING

MTL METAL

OPP HD OPPOSITE HAND

PL.

LEGEND

DOUBLEDBL

INFO INFORMATION

MOD MODULE

T TOP

B BOTTOM

CONC CONCRETE

H.S.B HIGH STRENGTH BOLT

1. TESTING OF ANCHORS SHALL BE AS PER IBC 2018

2. ALL FIELD INSTALLED CONCRETE EXPANSION ANCHORS SHALL BE

APPROVED FOR THE TYPE AND INSTALLATION, FOR ITS APPLICATION, AND

MATERIALS. EXPANSION ANCHORS SHALL BE HILTI KWIK BOLT TZ (

ICC-ESR-1917) HILTI - HSL 3 (ICC-ESR-1545) OR APPROVED EQUIVALENT.

EQUIVALENT ANCHORS SHALL HAVE AN APPROVED 1CC NUMBER.

3. EXPANSION ANCHORS SHOWN IN THESE DOCUMENTS SHALL BE TESTED AS

FOLLOWS: (HARDROCK OR LIGHTWEIGHT CONCRETE)

ANCHOR SIZE TORQUE (FT-lb)

8" 25

2" 40

8" 60

4" 110

WHERE EQUIVALENT ANCHORS ARE USED TORQUE VALUES SHOULD BE AS

STATED IN THE ICC REPORT.

1. POWDER DRIVEN FASTENERS SHALL BE HILTI AS PER ICC-ESR-2269 OR APPROVED EQUAL.

BASE

MATERIAL

STEEL

FASTENER

TYPE

MINIMUM

EBEDMENT

MINIMUM

EDGE DISTANCE

MINIMUM

SPACING

CONCRETE

X-U STEEL 1/2" 1"

X-U W/ DX-KWIK 11

2 " 3" 4"

S-001

GENERAL NOTES & DETAILS

SEISMIC DESIGN DATA:

SEISMIC IMPORTANCE FACTOR

MAPPED SPECTRAL RESPONSE: S 1

SITE CLASSIFICATION: D

SPECTRAL RESPONSE:

DS D1

SEISMIC DESIGN CATEGORY: D

I = 1.5

S = 1.972 S = 0.703

S = 1.578 S = ASCE 7-16

SEISMIC SYSTEM - DEMANDS ON NON STRUCTURAL COMPONENTS

SHEAR

COMPONENTS AMPLIFICATION FACTOR ap = 2.5

Fp = 0.4 ap Sds Wp ( R / I )

( 1 +2 )Z h

COMPONENTS RESPONSE FACTOR Rp = 2.5

P P ap = 1.0

OVER STRENGTH FACTOR Ωo = 2.5

REDUNDANCY FACTOR p = 1.0

SCALE

SCALE

SCALE

SCALE

P

INSPECTION REPORT SHALL BE PROVIDED TO THE VA PROJECT MANAGER, CONTRACTING

OFFICER, ENGINEER OR ARCHITECT OF RECORD WITHIN ONE WEEK OF INSPECTION.

2.

THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE VA PROJECT

MANAGER, CONTRACTING OFFICER, ARCHITECT OR ENGINEER OF RECORD, AND THE

CONTRACTOR. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF

THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, SUBMIT A COMPLETE LIST

OF ALL OUTSTANDING DISCREPANCIES ON A WEEKLY BASIS TO THE CONTRACTING VA

PROJECT MANAGER, CONTRACTING OFFICER, AND ARCHITECT OR ENGINEER OF RECORD,

UNTIL ALL CORRECTIONS HAVE BEEN COMPLETED.

B.

C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING WEATHER THE

WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE INSPECTOR'S

KNOWLEDGE, IN CONFORMANCE WITH APPROVED PLANS AND SPECIFICATIONS AND THE

APPLICABLE WORKMANSHIP PROVISIONS OF THE BUILDING CODE.

JB JUNCTION BOX (ELECTRICAL)

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

"L

1A

1A

45°45

" M

IN

(E ) 7

" T

HK

FI

EL

D

VE

RI

FY

S-301

S-301

3"

2'-0" MAX.

EA. DIRECTION

TYP.

S-301

EQUIPMENT ANCHORAGE DETAILS

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

BT BT

MAIN LOBBY

C1-71

PASSANGER

ELEVATOR

LOBBY

C1-1

WAITING

C1-59

RECEPTION

B102

B100

FILES

B124

CORRIDOR

C1-58

ELEVATOR

LOBBY

C1-72

TOILET

A101

TOILET

A100

CORRIDOR

C1-76

CONTROL ROOM

A104

POLICE

A103

AGENT

CASHIER

A105

SERVICE

ELEVATOR

LOBBY

CA-79

OFFICE

A113A

STAFF

TOILET

A112

CHIEF

A102A

OFFICE

A102

CORRIDOR

C1-90

COMPUTER ROOM

A114

MEDICAL/ GENERAL

STORAGE

A126

SERVICE

ENTRY

C1-91

SOILED LINEN

A125

PEST CONTROL

OFFICE

A124

PEST CONTROL

WORKROOM

A123

MED GAS

A122

FLAM. STOR.

A121

OFFICE

A120

HAC

A118

STAFF

TOILET

A119

OFFICE

A126A

LOCKABLE

STOR.

A126B

A114A

CHIEF

A127C

A127D

PROS. REP.

A127B

PROS. REP.

A127A

CORRIDOR

C1-94

A111

A110

CLERKS

A127

A127E

DRESSING

A129A

WORK ROOM

A129

VOLUNTEER

COORDINATOR

A130

VETS ASSIST

A128

OFFICE

A113B

OFFICE

A113C

OFFICE

A113D

OFFICE

A113E

KEYPUNCH&

EQUIPMENT

A113

OFFICE

A113G

STOR.

A113F

A115B

LOCK SHOP

A115D

ENGINEERING

SHOP

A115

ENGINEERING

OPERATION SSECTION

A115B

SUPERVISING ENG.

OPERATION

A115A

PAINT

STORAGE

A115E

PARKING EQUIP.

STORAGE

A117

C1-84A

HAC

A116

A114B

CORRIDOR

C1-84

VA POLICE

A106

SUPERVISOR

A106B

A106C

LOCKER

A106A

TRASH HOLDING

A108

HAC

C1-60

WAITING

C1-49

EL. CL.

A131A

EL. CL.

A131B

HAC

A131C

ON CALL

A131D

ISOLATION

BEDROOM

A131G

TOILET

A131E

TOILET

A131L

ANTREROOM

A131K

STORAGE

A131M

RECOVERY BEDS

A131

CORRIDOR

C1-40

CORRIDOR

A131P

CONTROL

STATION

A131F

EQUIP.

STORAGE

A133

HAC

A132

DRESSING

A134

LOCKER

A134A

DRESSING

A134C

PRE-OP

HOLD

A135

TOILET

A134B

CLEAN

UTILITY

A136

PATIENT

TOILET

A131H

STAFF

TOILET

A131I

A131J

CORRIDOR

C1-45

CORRIDOR

C1-42

O.R.

SUPERVISOR

A141

SPD

STORAGE

A139

LIGHT/ DARK

ROOM

A140

HOLDING

A138

RAD.

EQUIP

A137

ENDOSCOPY #2

A142

TOILET

A142A

CORRIDOR

C1-33

OPERATING

ROOM #2

A153

OPERATING

ROOM #1

A152

SURGICAL

CORRIDOR

C1-34

LIFE

SUPPORT

A145

ANESTHESIOLOGIST

A154

ANESTH. GAS

STORAGE

A155

ANESTHESIA

WORK ROOM

A156

INSTR. PREP/

STORAGE

A157

MECHANICAL

A158

A151

STER.

A151C

A144A

DECONTAM

A144

ENDOSCOPY #1

A143

CART

WASH

A151B

TELE. CL.

A147

CLEAN

PROCESSING

A151D

EL. CL.

A146

TOILET

A143A

EQUIP.

STORAGE

A151A

STAFF

LOUNGE

A150

CORRIDOR

C1-30

MALE

LKRS/ SHWR/ TOILET

A148

FEMALE

L/S/T

A149

CORRIDOR

C1-28

A158-A

CHIEF

SERV. OFF

B128H

STUDENT

OFFICE

B128G

CLINICAL PHARM.

TEACH COOR. OFFICE

B128E

RESIDENT

OFFICE

B128C

SURGEON

LOUNGE

A160

DICTATION

A160A

HAC

A159

HAC

B128A

CONSULTATION

B126

CONSULTATION

B127

CORRIDOR

C1-22

DRUG

INFORMATION

B128B

CLERICAL

WORK AREA

B440

CLIN. PHARM.

OFFICE

B128I

CLERICAL/

CLASSROOM

B128K

STAFF

TOILET

B128J

CORRIDOR

C1-23

WAITING

C1-20

DISPENSING

STATION

B128S

ACTIVE

STORAGE

B1280

CORRIDOR

C1-2

CORRIDOR

C1-3

ACTIVE

STORAGE

B128M

SUPERVISOR

OFFICE

B128N1

PRE-PACKAGING

BULK COMPOUNDING

B128N

INACTIVE

STORAGE

B128P

CONTROLLED

SUBSTANCE STOR.

B128D

DRUG RECEIVING

AND BREAKOUT

B128L

ELEC. CL.

B129

TELE. CL.

B130

CORRIDOR

B128

CONSULTATION

B131

CONSULTATION

B132

MECHANICAL

B135

DISPENSING

B134

VAULT

B134A

CORRIDOR

C1-14

B135A

HAC

B133

SPECIMEN

TOILET

B136

REHAB

TECH

B137

PSYCHOLOGIST

B139

CHIEF

D.D.T.C.

B143

PSYCHOLOGIST

B141

SOCIAL

WORKER

B144

SOCIAL

WORKER

B145

SOCIAL

WORKER

B147

SOCIAL

WORKER

B148

SOCIAL

WORKER

B149

SOCIAL

CLERICAL

B150

CONFERENCE

GROUP THE.

B153

CORRIDOR

C1-11

SOCIAL

WORKER

B142

SOCIAL

WORKER

B140

SOCIAL

WORKER

B138

NURSE

B158

NURSE

B157

TREATMENT

B155

SOCIAL

CLERICAL

B151

TOILET

B152

TOILET

B154

B156

RECEPT. POLICE

CONTROL ROOM

B156A

CORRIDOR

C1-5

C1-9

WAITING

B156B

CORRIDOR

C1-4

CORRIDOR

C1-56

PHYSICIANS

ASSISTANT

B125

IT ROOM

B122

CLERICAL

OFFICE

B119

OBSERV &

TREATMENT

B108

CLEAN

UTILITY

B107

TOILET

B107C

CONSULTATION

B111

HSE

STAFF

B110

EXAM

B109

CORRIDOR

C1-63

MED

ROOM

B106

SOILED

UTILITY

B105

NURSE

STATION

B104

EXAM

ROOM

B117

EXAM

ROOM

B115

EXAM

ROOM

B113

CORRIDOR

C1-62

SECURITY

HOLDING

B103A

PATIENT

HYGENIE

B103

CORRIDOR

C1-64

EXAM

ROOM

B114

STAFF NURSE

WALKIN CLOSET

B116

EXAM

ROOM

B118

EXAM

ROOM

B120

EXAM

ROOM

B121

CORRIDOR

C1-55

FIRE SPRINKLER

CLOSET

A110A

STAFF

TOILET

B146

NURSE

TOILET

B112

INTERVIEW

B218

CORRIDOR

C2-26

CORRIDOR

C2-44

GROUP

ROOM

A227

ADP TRAINING

IRM SERVICE

A259

CLINIC

RECEPTION

C2-72

SUPERVISOR

A259A

TELE.CL

A261

CANTEEN

A255

H.A.C.

A258

CHIEF

SURGICAL

SERVICE

A250

STAFF

BREAK ROOM

A242

CORRIDOR

C2-50

INTERNIST

A212

ASSESSMENT

ROOM

B216

MECHANICAL

B240

TEAM

OFFICE

B246

TOILET

B243

TEAM

OFFICE

B249

CASE

MANAGER

A233

WAITING

C2-70

CORRIDOR

C2-45

CORRIDOR

C2-86

PHYSICIAN ASST

MEDICAL SERVICE

A214

EXAM

ROOM #4

A237

MECHANICAL

A262

PASSENGER ELEVATOR LOBBY

C2-1

SERVICE

ELEVATOR LOBBY

C2-3

SURGICAL

NURSE

A240

EXAM

ROOM #1

A248

ELEC.CL

A260

C2-86A

EXAM

ROOM #2

A246

CORRIDOR

C1-26

INTERNIST

A213

CORRIDOR

C2-55

INTERVIEW

A222

MALE

LOCKER

A252

CANTEEN

OFFICE

A254

AFGE

LOCAL 2297

A263

STAFF

PODIATRIST

A239

CORRIDOR

C2-83

SPD NURSING

SERVICE

A232

EMPLOYEE'S

LOUNGE

A257

C O

R R

I D

O R

C

C O

R R

I D

O R

C

EXAM

ROOM

A204

STRETCHER STORAGE

C2-43

(TEMP)

EKG PROCEDURE

ROOM

A216

GROUP

ROOM

B226

FEMALE

LOCKER

A253

HUD VASH SPA 4

STAFF VETERAN

MEETING ROOM

A264

CORRIDOR

C2-53

CORRIDOR

C2-80

STAFF

TOILET

A238

UTILITY

A224

MEDICAL

TREATMENT

B203

INTERVIEW

A218

PHYSICIAN

OFFICE

A208

INTERVIEW

A217

MECHANICAL

A211

CORRIDOR

C2-44

ELEC. CL.

A266

TELE. CL.

A267

INTERVIEW

B224

INTERVIEW

A220

C O

R R

I D

O R

C

MEDITATION

B200

INTERVIEW

B221

CORRIDOR

C2-34

ASSESS

ROOM

A215

EXAM

ROOM

A206

INTERVIEW

A221

EXAM

ROOM

B207

EXAM

ROOM

B211

TEAM

OFFICE

B255

TOILET

A223

INTERVIEW

B225

INTERVIEW

A219

INTERVIEW

B218

EXAM

ROOM

B205

WAITING

C2-37

NURSE

A202

CHIEF

NEURO

SERVICE (?)

B239

INTERVIEW

B217

INTERNIST

B212

PULMONARY

LAB (?)

B212

EXAM

ROOM

B209

INTERNIST

B214

CORRIDOR

C2-2

INTERVIEW

B219

OFFICE

B244

HAC

B213

EXAM

ROOM

B230

EXAM

ROOM

B231

INTERVIEW

B220

CORRIDOR

C2-16

INTERVIEW

B223

PHYSICIAN

OFFICE

B229

WAITING

C2-22

PRIMARY CARE

TEAM B

B234

TELE. CL.

B264

ELEC. CL.

B265

CALL CENTER

B263F

CONFERENCE

ROOM

B256

EXAM

ROOM

B228

INTERNIST

B227

TOILET

B238A

CORRIDOR

C2-63

STORAGE

B241

INTERVIEW

B222

C O

R R

I D

O R

C

IRM

SERVICE

B258

CALL CENTER

B263E

CALL CENTER

B263

TEAM

OFFICE

B242

CALL CENTER

B263J

TEAM

OFFICE

B250

VEST

B252

FEMALE

TOILET

B266

CONFERENCE

ROOM

B247

B263G

HOUSE (?)

STAFF

B235

CLERK

B261A

STORAGE

B261B

TEAM

OFFICE

B248

RECORD REVIEW

ROOM

B263C

OPEN

PLAN

B245

CORRIDOR

C2-4

MALE

TOILET

B267

BREAK ROOM

B263A

COPY

B245A

VESTIBULE

C2-65

CHIEF MED.

REC

B263D

CORRIDOR

C2-67

RE-PRODUCTION &

MECHANICAL

B260

B263H

MAIL

ROOM

B261

CONFERENCE

ROOM

B263B

B263I

HAC

B259

AFGE

LOCAL 2297

A258

CORRIDOR

C2-56

SECRETARY

A251

HAC

A265

MSA

OFFICE

A249

EXAM

ROOM

A247

EXAM

ROOM

A245

CHIEF

SURGERY SERVICE

A243

C O

R R

I D

O R

C

DRESSING

ROOM

A234

HAC

A241

EXAM

ROOM #3

A244

STUDENT

EXAM

A235

WHC RN

A228

PHYSICIAN

ASSISTANT

A230

GYNECOLOGY

EXAM

A229

EXAM

ROOM

A210

EXAM

ROOM

A209

EXAM

ROOM

A205

EXAM

ROOM

A207

NURSE

A203

CORRIDOR

C2-39

EXAM

ROOM

B208

CASE

MANAGER

B210

C O

R R

I D

O R

C

PHARMACIST

B201

EXAM

ROOM

B206

MED. ADMIN

SERV.

A201

NURSE

PRACTITIONER

B202

MEDICAL

EQUIPMENT

B204

EXAM

ROOM

B238

EXAM

B237

HOUSE

STAFF

B236

PHYSICIAN (?)

ASSISTANT

B232

NURSE

B233

CORRIDOR

C2-21

RE-PRODUCTION &

EMBOSSING

B262

PODIATRY

EQUIP. STOR.

A231

INTERVIEW

A226

INTERVIEW

A225

CORRIDOR

C2-15

MIND/ BODY THERAPY

ROOM

A353

CORRIDOR

C3-51

PASSENGER

ELEVATOR

LOBBY

C3-1

SECRETARY

A341

RESEARCH

WORKROOM

A340

C

O

R

R

I

D

O

R

C

ELEC. CL.

A336A

TELECOM CL.

A336B

C

O

R

R

I

D

O

R

C

GARDEN ROOM

S02

LIBRARY

A337

C

O

R

R

I

D

O

R

C

WALK-IN

REFRIGERATOR

A330B

HAC

A330

CHIEF

TECH

A330A

TOILET

A330

TOILET

A328

CORRIDOR

C3-40

SPECIMEN

COLLECTION

A327

CORRIDOR

C3-27

LAB & RADIOLOGY

WAITING

S-03

ELEC. CL.

S-06

MECHANICAL

S14

CYSTOSCOPY

A306

CORRIDOR

C3-23

FILM

VIEWING

A316A

TOILET

A307B

RADIOLOGY

FLUOROSCOPY

A305

FILM

LIBRARY

A316

ULTRASOUND

A311

TOILET

A310B

SCRUB &

GOWNING

A306A

CORRIDOR

C3-21

GENERAL

RADIOLOGY

A307

GENERAL

RADIOLOGY

A310

CORRIDOR

C3-15

CORRIDOR

C3-22

CORRIDOR

C3-4

ELEC. CL.

B303

CORRIDOR

C3-2

CORRIDOR

C3-5

SOUND SUIT

AREA

B358A

CORRIDOR

C3-6

CORRIDOR

C3-12

WAITING

S-09

B362A

RES

OFFICE

B326

OPTOM

STUD.

B320

EYE EXAM

B317

EXAM

B312

EVOKED

POTENTIAL

EXAM

B315

CORRIDOR

C3-68

CORRIDOR

C3-64

CHIEF

OPHTHALMOLOGY

B327

CORRIDOR

C3-67

FEMALE

TOILET

B318A

STUDENT

CUBICLE

B318

HAC

B316

EYE EXAM

B324

VIS

FIELDS

B313

ASSIST. CHIEF

STAFF

FOR RESEARCH

A342

WORKROOM

CLERICAL

A336C

CORRIDOR

C3-24

C

O

R

R

I

D

O

R

C

CORRIDOR

C3-16

CORRIDOR

C3-11

TELE. CL.

B304

CORRIDOR

C3-28

TELE CL.

S-05

MECHANICAL

B358

OPTOM

STUD.

B321

STAFF

OPTOMETRIST

B323

CHIEF

OPTOMETRY

B325

RECEPT.

B310A

SOCIAL

WORKER

B328

CORRIDOR

C3-63

CORRIDOR

C3-18

B316A

EYE EXAM

B322

DARKNESS

ADAPTATION

B314

EAR & THROAT

EXAM

B310

MALE

TOILET

B318A

OPTOM

STUD.

B319

EXAM

B311

SOUND

SUITE 3

B353A

SOUND

SUITE 3

B353B

SOUND

SUITE 2

B352

SOUND

SUITE 2

B352A

B362A

SOUND

SUITE 1

B362

WAITING

B353

CORRIDOR

C3-48

ELEVATOR

LOBBY

C3-3

STORAGE

A354

STAFF

TOILET

A352

CORRIDOR

C3-52

INVESTIGATOR

A343

INVESTIGATOR

A345

INVESTIGATOR

A346

COMMON USE

ROOM

A347

HAC

A344

LAB

SERVICE

A338C

SECRETARY

A338D

STUDENT

CUBICLE

A338B

PHOTOCOPY

MICROFORM

A338

LIBRARIAN

A338A

ADP

A331

CORRIDOR

C3-42

HOUSE STF/

STUDENT CUBICLE

A329A

EQUIP.

STORAGE

A329

CORRIDOR

C3-44

CORRIDOR

C3-43

CHEMISTIRY

HEMOTOLOGY

URINE AND FECES

A331A

MICROBIOLOGY

A331C

TOXICOLOGY

IMMUNOLOGY

A331D

STERILIZATION &

SOLUTION PREP.

A329F

ELEC. CL.

A303

DRESS

A322A

DRESS

A326

CHEST

X-RAY

A325

FILM

STOR.

A323

EQUIP.

STOR.

A322

CHIEF

RADIOLOGY

A321

CLEAN

UTILITY

A320

X-RAY

TECNOLOGIST

A319

LIGHT

ROOM

A324

DARK

ROOM

A304C

HAC

A304D

DRESS

A304A

TOILET

A304B

TOLIET

A306B

UROLOGIST

A303

SOILED

UTILITY

A308

TOILET

A311A

DRESS

A307A

DRESS

A310A

TR

A312

HAC

C-40

STAFF

PHYS.

A313

STAFF

PHYS.

A314

CONSULT

A315

FILM

PROG

C-06

GRAPHIC

ILLUSTRATIONS

B357

CORRIDOR

C3-20

MEDICAL

MEDIA

STUDIO

B359

TRANIEE

B358

CONSULT

B308

CONSULT

B306

CONSULT

B307

CONSULT

B305

INSTRUMENT

CALIBRATION

STORAGE

B361

CORRIDOR

C3-7

HEARING AID

CLERK

S-10

AUDIO

OFFICE

B348

AUDIO

OFFICE

B351

AUDIO

OFFICE

B346

AUDIO

OFFICE

B347

AUDIO

OFFICE

B344

ACOUSTICAL

IMPEDANCE

TESTING

B350

ELECTRO

NYSTO.

B349

AURAL

REHAB

B345

APHASIA

ROOM

B343

AUDIO

OFF

B342

AUDIO

OFF

B341

AUDIO

OFF

B340

SECRETARY

B339

SPEECH

PATH.

B338

SPEECH

PATH.

B337

SPEECH

PATH.

B335

EAR

MOLD

FABRICATION

B333

CORRIDOR

C3-10

CLERICAL

RECEPTIONIST

B330

EAR & THROAT

EXAM

B330

CHIEF

E.N.T.

B329

TOILET

B334

GROUP

THERAPY

B423

DAY

ROOM

C-01

PYSCHIATRIST

B424

SOCIAL

WORKER

B425

CHIEF

DAY

TREATMENT

B426

OCCUP.

THERAPIST

B427

SECRETARY

WAITING

B428 TOILET

B422

CERAMICS

WORK

ROOM

B420

STORAGE

B421

EDUCATIONAL

THERAPY

B418

STORAGE

B429

A.D.L.

TOILET

B431

A.D.L.

KITCHEN

B431

OCCUP.

MECHANICAL

B432

CORRIDOR

C4-15

QUIET

ROOM

B415

RECEPTION

B417

KITCHEN

B419

DAY TREAT.

CENTER VEST.

X

HAC

B416

ACTIVITY &

EXERCISE

AREA

B411

SOCIAL

WORKER

B433

PHYSICIANS

ASSIST.

B434

SECRE.

WAITING

B435

RESIDENT

STUDENT

B436

SHOWER

B409

UTILITY

STORAGE

B412

TELE

CLOSET

B414

ELEC

CLOSET

B413

CORRIDOR

C4-16

CORRIDOR

C4-4

CORRIDOR

C4-17

DRESSING

B408

SHOWER

B407

CHIEF

REHAB

MED CENTER

B437

PHYSICIANS

OFFICE

B438

PHYCHOLOGY

B433

CORRIDOR

C4-25

PHYSICIANS

OFFICE

B440

NURSE

B441

COORD.

ALC. DEPT.

TREATMENT

B443

MECHANICAL

A409

THERAPIST

OFFICE

B405

TOILET

X

HDYROTHERAPY

B403

HAC

B442

GROUP

THERAPY

B444

TOILET

A401

TOILET

B401

VESTIBULE

B401B

CORRIDOR

C4-2

STORAGE

A402

SECRETARY ALC.

DEPT. WAITING

A404A

SOCIAL

WORKER

A407

SOCIAL

WORKER

A404

SOCIAL

WORKET

ASSIST.

A406

CORRIDOR

C4-27

SLEEP

LAB.

A403

SOCIAL

WORKER

A408

SOCIAL

WORKER

A405

TRAINEE

OFFICE

A412

TRAINEE

OFFICE

A413

TRAINEE

OFFICE

A414

EVOKED

POTENTIAL

LAV

A415

SOCIAL

WORKER

A410

SOCIAL

WORKER

A411

CHIEF

SOCIAL WORK

SERVICE

A411

SOCIAL

WORKER

A418

SOCIAL

WORKER

A417

SOCIAL

WORKER

A416

TELE

CLOSET

X

ELEC

CLOSET

X

SOCIAL WORK

WAITING

A416C

PSYCHOLOGY

WAITING

X

CORRIDOR

C4-30

TRAINEE

OFFICE

A421

X

B424A

B423A

B424B

DRESSING

B406A

REHAB

MED

SERVICE

B413E

WAITING

B406A

ELECTROMYOG.

EXAM

ROOM

B402

VESTIBULE

A401A

TRAINEE

OFFICE

A422

CLERICAL

A423

SECRETARY

A420

SECRETARY

A426

CLOSET

A426A

CLOSET

A420A

CORRIDOR

C4-26

HAC

A425

CORRIDOR

C4-12

MULTIPURPOSE

A424

STORAGE

A430

BIOFEEDBACK

A428

OBSERVATION

A429

CORRIDOR

C4-13

TRAINEE

OFFICE

A438

TRAINEE

OFFICE

A437

TRAINEE

OFFICE

A435

TRAINEE

OFFICE

A433

GROUP

THERAPY

A432

GROUP

TEC

A431

CHIEF

PSYCHOLOGY

SERVICE

A427

PSYCHOLOGY

TECH

A434

PSYCHOLOGIST

A436

TRAINEE

OFFICE

A439

OBSERV

A440

GROUP

THERAPY

A444

CORRIDOR

C4-16

CORRIDOR

C-15

PSYCHOLOGIST

A441

PSYCHOLOGIST

A442

PSYCHOLOGIST

A443

MECHANICAL

A445

CHIEF

PSYCHIATRY

A450

HOUSE

STAFF

A451

CONSULTATION

A452

CONSULTATION

A453

SOCIAL WORKER

A455

PSYCHOLOGIST

A458

PSYCHOLOGIST

A460

PHYSICIAN

OFFICE

A462

CONFERENCE

A463

CHIEF

MENTAL

HYG.

A465

CHIEF

MENTAL

HYG.

A465

PHYSICIAN

OFFICE

A466

PHYSICIAN

OFFICE

A467

PHYSICIAN

OFFICE

A470

CORRIDOR

C-18

TREATMENT

A469

PHYSICIAN

OFFICE

A468

NURSE

A464

TOILET

A461

HAC

A459

HOUSE

STAFF

A457

SOCIAL

WORKER

A456

SOCIAL

WORKER

A454

ELEC CL.

A447

TELE CL.

A446

PHYSICIAN

OFFICE

A448

SECRETARY

WAITING

A449

CORRIDOR

C-19

CORRIDOR

C-20

CORRIDOR

C-17

CORRIDOR

C-22

SERVICE ELEV.

LOBBY

C-11B

PASSENGER ELEV.

LOBBY

C-11A

TR ROOM

B444A

DN.

ELEV.

ELEV.

ELEV.

ELEV.

ELEV.

ELEV.

UP

CORRIDOR

C-10

DENT

RESEARCH

A535

ORAL

SURGERY

A534

DENT

RESEARCH

A533

DENT

RESEARCH

A532

GEN

TREAT

A531

INSTR.

PREP

A530

CORRIDOR

C-7

SOILED

SPD

A534

GEN

TREAT

A527

GEN

TREAT

A524

COORDINATOR

A525

GEN

TREAT

A523

STORAGE

A521

GEN

TREAT

A520

CLEAN SPD

CART

A528

GEN

TREAT

A538

GEN

TREAT

A537

CORRIDOR

C-9

GEN

TREAT

A539

GEN

TREAT

A540

PATIENT

TOILET

A526

CLOSET

A522A

PROSTH. LAB.

A522

ELEC

CL

A541

TELE

CL

A541

CORRIDOR

C-8

GEN

TREAT

A519

GEN

TREAT

A518

PROG

COOR.

A517

PREVENT

DENTISTRY

A516

INTERVIEW

A503

WAITING

C06

RECEPTION

COUNTER

A504

EXAM

OPERATORY

A515

EXAM

CORRIDOR

C513A

DARK

ROOM

A513

DARK

MECHANICAL

A514

XRAY 1

A512

XRAY 2

A511

STUDIO

CLASSROOM

LOUNGE

A510

GERIAT

OFFICE

A509

HAC

A508

CHIEF

DENT

SERVICE

A505

ASSIST

CHIEF

OFFICER

A506

STOR

A507

M. TOILET

A501

IT

CLOSET

A502

F TOILET

B501

VEST

A502A

VEST

B501A

SERVICE ELEV.

LOBBY

C-12

PASSENGER ELEV.

LOBBY

C-11

CHIEF

PERSONNEL

B506

SECRETARY

B505

PERSONAL

MGT. SPECIALITS

B504

PERSONAL

MGT. SPECIALITS

B503

PERSONAL

MGT. SPECIALITS

B502

CORRIDOR

C-04

WAITING

C-05

ASSIST

CHIEF

B507

STOR

B508

PLACEMENT &

EXAM ROOM

B509

CLERK/ FILES

PERSONNEL

B510

CHIEF

FISCAL

SERVICE

B512E

ASSIST

CHIEF

B512A

ACCOUNTING

B512D

FINANCE

B512C

PAYROLL

B512B

SECRETARY

B512F

ELEC.

CL

B511

WORK AREA

B512

MECHANICAL

B521

CORRIDOR

C-03

CORRIDOR

C-02

COORDINATOR

H.S.R.O.

B524

AA/COS

B525

X

B526

CHIEF

OF STAFF

B527

SECRETARY

B531

SECRETARIES

B529

CORRIDOR

C-01

ASS. DIR.

B528

DIRECTOR

B530

CORRIDOR

B533A

TOILET

B533

REP CONS

CONFERENCE

B540

CHIEF

ENGINEER

B519

CLERICAL/

SECRETARY

B517

FELLOWSHIP&

INTERNS

B515

TELE

CL

B513

STOR

B512G

DRAFTING

B520

X

B518

FIRE SAFETY

B516

HOUSE

STAFF

B514

CONFERENCE

B538

CLERICAL

B354

CLOSET

B356

HAC

B352

Q.A. COORD.

B522

COORDINATOR

EDUCATION

B523

SA/DIR

B535

HEALTH

SYST. OFFICE

B537

REP CONS

AFFAIR

B539

RECOVERY

A536

N

SCALE: 1/32"= 1'-0"

FIRST FLOOR MECHANICAL PLAN (TR B122)

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

BT BT

N

SCALE: 1/32"= 1'-0"

SECOND FLOOR MECHANICAL PLAN (TR B201 AND B263K)

N

SCALE: 1/32"= 1'-0"

THIRD FLOOR MECHANICAL PLAN (TR A312)

N

SCALE: 1/32"= 1'-0"

FOURTH FLOOR MECHANICAL PLAN (TR B444A)

N

SCALE: 1/32"= 1'-0"

FIFTH FLOOR MECHANICAL PLAN (TR A502)

CORRIDOR

C1-4

PHYSICIANS

ASSISTANT

B125

IT ROOM

B122

EXAM

ROOM

B121

MECHANICAL

A211

CORRIDOR

C2-39

EXAM

ROOM

B208

CASE

MANAGER

B210

PHARMACIST

B201

EXAM

ROOM

B206

NURSE

B441

COORD.

ALC. DEPT.

TREATMENT

B443

MECHANICAL

A409

HDYROTHERAPY

B403

HAC

B442

GROUP

THERAPY

B444

SOCIAL

WORKER

A407

SOCIAL

WORKET

ASSIST.

A406

CORRIDOR

C4-27

MEDITATION

B200

CORRIDOR

C2-63CALL CENTER

B263E

CALL CENTER

B263

FEMALE

TOILET

B266

CLERK

B261A

STORAGE

B261B

RECORD REVIEW

ROOM

B263C

MALE

TOILET

B267

BREAK ROOM

B263A

VESTIBULE

C2-65

CHIEF MED.

REC

B263D

CORRIDOR

C2-67

RE-PRODUCTION &

MECHANICAL

B260

MAIL

ROOM

B261

CONFERENCE

ROOM

B263B

RE-PRODUCTION &

EMBOSSING

B262

N

SCALE: 1/4"= 1'-0"

PARTIAL 1ST FLR - TR B122 MECH PLAN

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

BT BT

N

SCALE: 1/4"= 1'-0"

PARTIAL 2ND FLR - TR B201 MECH PLAN

N

SCALE: 1/4"= 1'-0"

PARTIAL 4TH FLR - TR B444 MECH PLAN

N

SCALE: 1/4"= 1'-0"

PARTIAL 2ND FLR - TR B263K MECH PLAN

MECHANICAL

S14

CYSTOSCOPY

A306

CORRIDOR

C3-23

FILM

VIEWING

A316A

TOILET

A307B

RADIOLOGY

FLUOROSCOPY

FILM

LIBRARY

A316

ULTRASOUND

A311

TOILET

A310B

CORRIDOR

C3-21

GENERAL

RADIOLOGY

A307

GENERAL

RADIOLOGY

A310

CORRIDOR

C3-15

CORRIDOR

C3-22

ELEC. CL.

CORRIDOR

C3-24

CORRIDOR

C3-16

TECNOLOGIST

UROLOGIST

A303

SOILED

UTILITY

A308

TOILET

A311A

DRESS

A307A

DRESS

A310A

TR

A312

HAC

C-40

STAFF

PHYS.

A313

STAFF

PHYS.

A314

CONSULT

A315

FILM

PROG

C-06

CORRIDOR

C3-20

TRANIEE

B358

CORRIDOR

C-7

PREVENT

DENTISTRY

A516

INTERVIEW

A503

RECEPTION

COUNTER

A504

EXAM

OPERATORY

A515

EXAM

CORRIDOR

C513A

DARK

ROOM

A513

DARK

MECHANICAL

A514

XRAY 1

A512

XRAY 2

A511

STUDIO

CLASSROOM

LOUNGE

A510

CHIEF

DENT

SERVICE

A505

M. TOILET

IT

CLOSET

A502

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

BT BT

N

SCALE: 1/4"= 1'-0"

PARTIAL 3RD FLR - TR A312 MECH PLAN

N

PARTIAL 5TH FLR - TR A502 MECH PLAN

PHYSICIANS

ASSISTANT

B125

IT ROOM

B122

EXAM

ROOM

B121

EXAM

ROOM

B208

PHARMACIST

B201

EXAM

ROOM

B206

HDYROTHERAPY

HAC

B442

GROUP

THERAPY

B444

CALL CENTER

B263E

CORRIDOR

C3-21

ELEC. CL.

CORRIDOR

C3-16

TR

A312

HAC

C-40

RECEPTION

COUNTER

A504

EXAM

CORRIDOR

C513A

XRAY 1

A512

XRAY 2

A511

HAC

A508

CHIEF

DENT

SERVICE

A505

ASSIST

CHIEF

OFFICER

A506

STOR

A507

IT

CLOSET

A502

F TOILET

B501

CORRIDOR

C1-90

COMPUTER ROOM

A114

A114A

A127C

A127D

A111

A110

A114B

N

SCALE: 1/4"= 1'-0"

PARTIAL 1ST FLR - TR B122 PIPING PLAN

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

BT BT

N

SCALE: 1/4"= 1'-0"

PARTIAL 2ND FLR - TR B201 PIPING PLAN

N

SCALE: 1/4"= 1'-0"

PARTIAL 4TH FLR - TR B444 PIPING PLAN

N

SCALE: 1/4"= 1'-0"

PARTIAL 2ND FLR - TR B236 PIPING PLAN

N

SCALE: 1/4"= 1'-0"

PARTIAL 3RD FLR - TR A313 PIPING PLAN

N

SCALE: 1/4"= 1'-0"

PARTIAL 5TH FLR - TR A502 PIPING PLAN

N

PARTIAL 1ST FLR - COMPUTER ROOM A114 PIPING PLAN

F

N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

BT BT

DIFFUSER MOUNTING DETAIL

CONDENSATE

DRAINAGE DETAIL

CHILLED WATER

COIL PIPING DETAIL

HORIZONTAL FAN COIL UNIT

MOUNTING DETAIL

4 1

PIPE SUPPORTS DETAIL

FAN COIL UNIT CONTROL

ARCHITECTURE

EXISTING BACNET SYSTEM

LEGEND

SINGLE LINE DIAGRAM SYMBOLS

GENERAL NOTES

TELECOMMUNICATION SYMBOLS

APPLICABLE CODES

ABBREVIATIONS

F I N

A L

S

U B

M I T

T A

L

12-J MAUCHLY

IRVINE, CALIFORNIA 92618

TEL: (949) 450-8420

FAX: (949) 450-8424

A R C H I T E C T U R E + E N G I N E E R I N G C O N S T R U C T I O N M A N A G E M E N T

GENERAL NOTES (CONT.)

AutoCAD SHX Text

ELECTRICAL SYMBOL, LEGEND AND NOTES

AutoCAD SHX Text E001

AutoCAD SHX Text

SWITCH.

AutoCAD SHX Text

CIRCUIT BREAKER.

AutoCAD SHX Text

FUSE.

AutoCAD SHX Text

TRANSFORMER.

AutoCAD SHX Text

GROUND.

AutoCAD SHX Text

CONTACTS.

AutoCAD SHX Text J

AutoCAD SHX Text

CONDUIT ROUTED CONCEALED IN WALLS OR ABOVE CEILING.

AutoCAD SHX Text

CONDUIT ROUTED BELOW FLOOR SLAB OR BELOW GRADE.

AutoCAD SHX Text

HOMERUN TO PANELBOARD OR EQUIPMENT INDICATED. NUMBER OF

AutoCAD SHX Text

ARROWHEADS EQUALS NUMBER OF CIRCUITS IN CONDUIT.

AutoCAD SHX Text

CONDUIT TURNING DOWN.

AutoCAD SHX Text

CONDUIT TURNING UP.

AutoCAD SHX Text

JUNCTION BOX

AutoCAD SHX Text

PANELBOARD.

AutoCAD SHX Text

LIGHTING CONTACTOR.

AutoCAD SHX Text

MAGNETIC MOTOR STARTER.

AutoCAD SHX Text 1.

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text M

AutoCAD SHX Text

MANUAL MOTOR STARTER WITH TOGGLE SWITCH AND THERMAL OVERLOAD.

AutoCAD SHX Text

DISCONNECT SWITCH, SURFACE MOUNTED, 600V,30A, 3 POLE, NEMA 1 ENCLOSURE

AutoCAD SHX Text

(UNLESS OTHERWISE INDICATED).

AutoCAD SHX Text

MOTOR, NUMBER INDICATES HP

AutoCAD SHX Text

AutoCAD SHX Text

3P/ 30A/ NEMA 1/ NF

AutoCAD SHX Text

NF-NON FUSED

AutoCAD SHX Text

AF-AMP FUSE (SIZE AS INDICATED)

AutoCAD SHX Text

FM-FUSE PER MANUFACTURES'S RECOMMENDATIONS

AutoCAD SHX Text

NEMA TYPE ENCLOSURE

AutoCAD SHX Text

AMPACITY

AutoCAD SHX Text

NO. OF SWITCHED POLES

AutoCAD SHX Text BEFORE SUBMITTING BID, THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH THE JOB CONDITION, SERVICE REQUIREMENTS BY UTILITY COMPANY AND CONNECTIONS, AND OTHER CONDITIONS INCLUDING TRANSFORMER PAD, ALL NECESSARY PULL BOXES, JUNCTION BOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS, CONDUIT FITTINGS, SERVICE COMPONENTS, PANELBOARDS, ETC., WHETHER SHOWN ON DRAWINGS OR NOT, TO MAKE A COMPLETE AND OPERABLE ELECTRICAL SYSTEM WITHOUT ADDITIONAL COST TO VA. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL LOCAL LAWS, RULES AND REGULATIONS OF ALL LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION. IN CASE OF CONFLICT BETWEEN REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. FOLLOW THE LOCAL LAWS, RULES AND REGULATIONS FOR ANY CONFLICTS BETWEEN THE CONTRACT DRAWINGS AND THE LAWS, RULES AND REGULATIONS. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE ALL REQUIRED INSPECTIONS FOR THE EXECUTION OF THE WORK UNDER THIS CONTRACT. HE SHALL FURNISH ALL INSTRUMENTS AND PERFORM ALL TESTS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. HE SHALL ALSO CORRECT ALL FAILURES AND REPLACE ANY DAMAGED PORTIONS OF THE WORK RESULTING FROM THE TESTS. THE COST OF THE FOREGOING ITEMS SHALL BE PAID BY THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE CLOSELY WITH THE VA PROJECT MANAGER, CONTRACTING OFFICER AND OTHER TRADES FOR ALL PHASES AND SCHEDULING OF WORK, AND AUTHORIZED IN WRITING BY THE VA PROJECT MANAGER AND CONTRACTING OFFICER AT LEAST TWO WEEKS PRIOR TO THE EXECUTION OF ANY WORK. ALL MATERIAL FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW AND UL LISTED, FREE FROM ALL DEFECTS, AND SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE OF THE WORK. INFORMATION ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT OR OUTLETS. ELECTRICAL CONTRACTOR (E.C.) SHALL COORDINATE WITH GENERAL CONTRACTOR (G.C.) AND WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF ALL LIGHTING FIXTURES, CEILING MOUNTED OUTLETS AND EQUIPMENT. CONTRACTOR SHALL COORDINATE CEILING SYSTEMS AND FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED CEILINGS. ALL RECEPTACLES & OUTLET MOUNTING HEIGHTS AND EXACT LOCATION SHALL BE COORDINATED WITH G.C. AND ELEVATION TO MATCH EXISTING ONES AS POSSIBLE. ALL RECESSED LIGHTING FIXTURES, PANELBOARDS, SWITCHES, ETC., MOUNTED IN FIRE RATED STRUCTURES SHALL BE ENCLOSED WITH AN APPROVED ENCLOSURE CARRYING THE SAME FIRE RATING AS THE STRUCTURE.

AutoCAD SHX Text ELECTRICAL OUTLETS ON OPPOSITE SIDES OF FIRE RATED WALLS AND PARTITIONS MUST BE SEPARATED BY MINIMUM DISTANCE OF 24 INCHES HORIZONTALLY, PER SPECIFICATION SECTION "26 05 33" PART "3.11.E". PER U.B.C. 4304, OPENINGS IN FIRE RATED WALLS GREATER THAN 16 SQ. INCHES MUST BE FIRE STOPPED. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS, ETC., TO MAINTAIN THE FIRE RATING. FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENT PENETRATING INTO FIRE RATED ENVELOPES, SPACES ETC. PORTIONS OF THE CEILING SYSTEMS MAY BE INACCESSIBLE. THEREFORE, THE CONTRACTOR SHALL STRATEGICALLY LOCATE ACCESS BOXES, ETC., WHICH SHALL BE READILY ACCESSIBLE. ALL LIGHTING FIXTURE WIRING, BALLASTS, J-BOXES, ETC. SHALL BE ACCESSIBLE FROM FIXTURE OPENING. ALL WIRING AND ELECTRICAL EQUIPMENT INSTALLED FOR MECHANICAL AND PLUMBING EQUIPMENT SHALL BE IN ACCORDANCE WITH DIVISIONS 22 & 23 AND ASSOCIATED DRAWINGS. CONTRACTOR TO OBTAIN THE REQUIRED MECHANICAL AND PLUMBING DRAWINGS AND PROVIDE ALL EQUIPMENT, RACEWAYS, WIRING, ETC., AS INDICATED THEREON AS PROVIDED UNDER THE ELECTRICAL WORK. ALL FINAL CONNECTIONS TO VA FURNISHED EQUIPMENT SHALL BE MADE BY THE CONTRACTOR UNLESS OTHERWISE NOTED. VERIFY ELECTRICAL CHARACTERISTICS AND U.L. LISTING PRIOR TO CONNECTION. THE CONTRACTOR SHALL VERIFY THE LOAD INPUT VOLTAGE OF ALL EQUIPMENT PRIOR TO INSTALLATION. ACCEPTING ANY EQUIPMENT RESULT IN LOAD INCREASE SHALL BE THE RESPONSIBILITY OF CONTRACTOR. PROVIDE AN ADDITIONAL JUNCTION BOX OR PULL BOX (SIZE AS REQUIRED) WHERE THE NUMBER OF CONDUCTORS OR TELECOM CABLES EXCEEDS THE MAXIMUM ALLOWED FOR A GIVEN JUNCTION POINT OR OUTLET. CONDUCTORS SHALL BE THHN/THWN 600 VOLT INSULATION COPPER UNLESS OTHERWISE NOTED. USE PROPER TEMPERATURE RATING OF CONDUCTORS BASED ON THE AMBIENT AIR TEMPERATURE WHERE CONDUCTORS ARE BEING USED. HIGHER AMPACITY CONDUCTORS AND LARGER RACEWAY SHALL BE PROVIDED TO OFFSET THE AMPACITY CORRECTION FACTORS AS INDICATED IN NEC TABLE 310 AND ELSEWHERE IN CODE.

AutoCAD SHX Text DO ALL DRILLING, CUTTING, CHANNELING AND PATCHING REQUIRED TO ELECTRICAL WORK AND INDICATED OR HEREIN SPECIFIED. ALL HOLES, CURBS, ETC,. IN FLOORS, CEILINGS AND WALLS SHALL BE PATCHED, UNLESS INDICATED OTHERWISE. PAINT ALL EXPOSED ELECTRICAL RACEWAYS, CABINETS, ENCLOSURES AND FITTINGS TO MATCH IN COLOR ADJACENT SURFACES IN FINISHED AREAS. BRANCH CONTROL CIRCUITING MAY NOT BE INDICATED ON THESE PLANS. CONTRACTOR IS RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE WITH PLAN NOTES AND AS PERMITTED BY LATEST NATIONAL ELECTRICAL CODE (N.E.C.) AND ANY LOCAL SUPPLEMENT. CONTRACTOR SHALL SUBMIT FINISH DRAWINGS AS A PART OF SHOP DRAWING SUBMITTAL TO ARCHITECT AND AUTHORITY HAVING JURISDICTION.

AutoCAD SHX Text 20.

AutoCAD SHX Text 21.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text 4.

AutoCAD SHX Text 5.

AutoCAD SHX Text 7.

AutoCAD SHX Text 8.

AutoCAD SHX Text 9.

AutoCAD SHX Text 10.

AutoCAD SHX Text 11.

AutoCAD SHX Text 12.

AutoCAD SHX Text 13.

AutoCAD SHX Text 14.

AutoCAD SHX Text 15.

AutoCAD SHX Text 16.

AutoCAD SHX Text 17.

AutoCAD SHX Text 6.

AutoCAD SHX Text 18.

AutoCAD SHX Text

EXISTING FEEDER

AutoCAD SHX Text E

AutoCAD SHX Text OUTLET BOXES AND J-BOXES: BOXES SHALL BE GALVANIZED, PRESSED STEEL BOXES WITH KNOCKOUTS AND SHALL BE A MINIMUM 1 1/2" DEEP. BOXES FOR USE WITH RECEPTACLES AND OUTLETS SHALL BE A NOMINAL 4" BY 2" OR 4" BY 4" UNLESS NOTED OTHERWISE. BOXES SHALL UTILIZE SCREW ON COVERS. INSTALLING BACK BOXES FOR ELECTRICAL DEVICES BACK TO BACK IN INTERIOR WALLS IS NOT ACCEPTABLE. LIGHTING FIXTURES FURNISH AND INSTALL LIGHTING FIXTURES OF THE TYPE SPECIFIED ON THE DRAWINGS. PROVIDE APPROPRIATE MOUNTING HARDWARE FOR THE CEILING TYPE INDICATED ON THE ARCHITECTURAL DRAWINGS. FIELD VERIFIES EXISTING CEILINGS. ENERGY SAVING LAMPS, BALLASTS AND LED DRIVERS OF THE TYPE INDICATED BY THE FIXTURE SCHEDULE OR THE DRAWINGS SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. (BALLASTS & FLUORESCENT LUMINAIRES AND LED FIXTURES SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION.) EMERGENCY LIGHTING SHALL BE PROVIDED PER U.B.C. OR LOCAL CODE AND SHALL BE DESIGNED TO PROVIDE MINIMUM REQUIRED ONE FOOTCANDLE AT EGRESS PATH AS REQUIRED. GROUNDING: PROVIDE INSULATED GROUNDING CONDUCTOR IN ALL CONDUITS WITH LIGHTING AND POWER CIRCUITS. SIZE PER NEC TABLE 250.122. PROVIDE GROUND CLAMPS AND ELECTRICAL TAPE FOR ALL EXPOSED GROUNDING CONNECTIONS. PROVIDE COATED OR WRAPPED EXOTHERMIC WELDS FOR ALL UNDERGROUND CONNECTIONS. TERMINATE GROUNDING CONDUCTOR AT EQUIPMENT GROUNDING LUG. THE CONTRACTOR IS REQUIRED TO PROPERLY FIRE-STOP ANY WALL, CEILING OR FLOOR PENETRATIONS UTILIZED FOR THE PLACEMENT OF COMMUNICATIONS CABLING AND ELECTRICAL CIRCUITS/FEEDERS WITH APPROVED FIRE-STOPPING COMPOUND AND ACCORDING TO LOCAL AND NATIONAL CODES. ALL PENETRATED STRUCTURES ARE TO BE RETURNED TO ORIGINAL CONDITION AND FIRE RATING. THE CONTRACTOR SHALL PROVIDE LABEL ON EACH FIRE STOPPING ASSEMBLY TO IDENTIFY FIRE-STOPPING BRAND, MODEL AND SYSTEM NUMBER, HR RATING, INSTALLATION COMPANY, INSTALLATION DATE AND JOB/REFERENCE NUMBER. CONTRACTOR SHALL PROVIDE LOGGING DATA FOR ALL THE PENETRATIONS/FIRE STOPPINGS IN ELECTRONIC FORMAT AND SUBMIT TO VA FOR REVIEW AND APPROVAL AND FOR FUTURE RECORD. FOR ALL NEW TELECOM BACKBONE CABLES AND HORIZONTAL CABLES AT BOTH ENDS (AT TELECOM CABINETS/RACKS AT MCR AND TR'S AND AT OUTLETS), E.C. SHALL PROVIDE PERMANENT PARALLEL (IN-LINE) LABELS FOR CABLES AND PROVIDE PERMANENT MOUNTED LABELS AT EACH OUTLET. ALL LABELS SHALL BE PROVIDED WITH SPECIFIC IDENTIFICATION AS REQUIRED AND SHALL BE ANSI/TIA/EIA606C COMPLIANT. PROVIDE PERMANENT MOUNTED LABELS FOR ALL NEW ELECTRICAL AND TELECOM EQUIPMENT INCLUDING NEW UPS'S, ELECTRICAL PANEL, DISCONNECT SWITCHES, TELECOM CABINETS, RACKS AND CABINET/RACK MOUNTED EQUIPMENT, ET.C. ALL NEW LABELING SHALL BE COORDINATED WITH VA PROJECT MANAGER AND VA OIT, AND SHALL MEET SPECIFICATION SECTION "26 05 11" AND PART "5.1.5" OF "VA INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES (VERSION 3.0)". CONTRACTOR SHALL REQUEST STANDARD EXCEL FILE FOR TELECOM LABELING FROM VA PROJECT MANAGER, PRIOR TO PROJECT STARTS, AND SHALL UPDATE THE EXCEL FILE AND SUBMIT TO VA BEFORE PROJECT IS FINISHED.

AutoCAD SHX Text 24.

AutoCAD SHX Text CONDUITS: CONDUITS SHALL BE EMT, RIGID OR INTERMEDIATE FLEXIBLE STEEL TYPE. FLEXIBLE STEEL CONDUIT SHALL BE MANUFACTURED IN ACCORDANCE WITH UL-1, USED ONLY FOR LIGHTING FIXTURE CONNECTION, SHORT MOTOR CONNECTION OR FOR THE EQUIPMENT REQUIRING VIBRATION ISOLATION. LENGTH IS LIMITED TO 72" MAXIMUM. A GROUND WIRE IS REQUIRED IN ALL FLEXIBLE CONDUITS. CONCEAL ALL CONDUITS, UNLESS OTHERWISE NOTED. NEW CONDUCTORS SHALL NOT BE INSTALLED IN EXISTING CONDUIT WITH EXISTING CONDUCTORS.

AutoCAD SHX Text 22.

AutoCAD SHX Text 25.

AutoCAD SHX Text 26.

AutoCAD SHX Text 27.

AutoCAD SHX Text

CONDUIT SLEEVE.

AutoCAD SHX Text

NOT ALL THE SYMBOLS AND LEGENDS ON THIS SHEET ARE USED FOR THE PROJECT.

AutoCAD SHX Text

NEW EXIT SIGN

AutoCAD SHX Text NEW 2'X4' LED LIGHT FIXTURE. LOW CASE LETTER INDICATES SWITCH CONTROL DESIGNATION. UPPER CASE LETTER INDICATES FIXTURE TYPE

AutoCAD SHX Text

EX

AutoCAD SHX Text

WALL MOUNTED JUNCTION BOX

AutoCAD SHX Text

COMBINATION VOICE/DATA OUTLET 2"X4" BOX, WALL MOUNTED (THREE RJ45 AND ONE BLANK)

AutoCAD SHX Text CEILING RECESS MOUNTED ELECTRICAL RECEPTACLE: 120V, 20A, 2P, 3W, GROUND TYPE (NEMA 5-20R)

AutoCAD SHX Text QUADPLEX WALL RECESS MOUNTED ELECTRICAL RECEPTACLE: 120V, 20A, 2P, 3W, GROUND TYPE (NEMA 5-20R)

AutoCAD SHX Text

POWER POLE FOR FURNITURE SYSTEM

AutoCAD SHX Text DUPLEX WALL RECESS MOUNTED ELECTRICAL RECEPTACLE FED BY EMERGENCY STANDBY CIRCUIT: 120V, 20A, 2P, 3W, GROUND TYPE (NEMA 5-20R)

AutoCAD SHX Text DUPLEX WALL RECESS MOUNTED ELECTRICAL RECEPTACLE, GROUND FAULT INTERRUPTER TYPE: 120V, 20A, 2P, 3W, GROUND TYPE (NEMA 5-20R)

AutoCAD SHX Text CEILING MOUNTED RECESSED SPECIAL PURPOSE RECEPTACLE, VOLTAGE AND AMPERE RATING AS INDICATED

AutoCAD SHX Text a

AutoCAD SHX Text A

AutoCAD SHX Text NEW 2'X2' LED LIGHT FIXTURE. UPPER CASE LETTER INDICATES FIXTURE TYPE AND LOW CASE LETTER INDICATES SWITCH CONTROL DESIGNATION

AutoCAD SHX Text a

AutoCAD SHX Text A

AutoCAD SHX Text NEW CEILING RECESSED DOWNLIGHTS. LOW CASE LETTER INDICATES SWITCH CONTROL DESIGNATION. UPPER CASE LETTER INDICATES FIXTURE TYPE.

AutoCAD SHX Text D

AutoCAD SHX Text a

AutoCAD SHX Text

NEW CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR

AutoCAD SHX Text

NEW CEILING MOUNTED DAYLIGHT SENSOR FOR DAYLIGHT HARVEST SYSTEM

AutoCAD SHX Text

NEW FEEDER

AutoCAD SHX Text N

AutoCAD SHX Text

GENERATOR

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AUTOMATIC TRANSFER SWITCH

AutoCAD SHX Text

EXISTING WALL MOUNTED DUPLEX OR QUAPLEX RECEPTACLE TO BE REMOVED

AutoCAD SHX Text 19.

AutoCAD SHX Text NFPA 99 HEALTH CARE FACILITIES CODE 2018 IBC AND 2016 CALIFORNIA AMENDMENTS (2019 CALIFORNIA BUILDING CODE, PART 2, TITLE 24, CCR) NFPA 101, LIFE SAFETY CODE 2020 NEC AND 2019 CALIFORNIA AMENDMENTS (2019 CALIFORNIA ELECTRICAL CODE - PART 3, TITLE 24, CCR) 2018 UMC AND 2019 CALIFORNIA AMENDMENTS (2019 CALIFORNIA MECHANICAL CODE - PART 4. TITLE 24, CCR) 2018 UPC AND 2016 CALIFORNIA AMENDMENTS (2019 CALIFORNIA PLUMBING CODE - PART 5, TITLE 24, CCR) VA SEISMIC DESIGN REQUIREMENTS, H-18-8 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2018 IFC AND 2019 CALIFORNIA AMENDMENTS (2019 CALIFORNIA FIRE CODE - PART 9, TITLE 24, CCR) PG 18-10 VA ELECTRICAL DESIGN MANUAL (DEC 1, 2019) PG18-10 VA TELECOMMUNICATION AND SPECIAL TELECOMMUNICATIONS SYSTEMS DESIGN MANUAL (FEBRUARY 2016) VA OFFICE OF INFORMATION & TECHNOLOGY DESIGN GUIDE (FEBRUARY 2011) H-18-8 VA SEISMIC DESIGN REQUIREMENTS (NOVEMBER 1, 2019, REVISED VA SEISMIC DESIGN REQUIREMENTS (NOVEMBER 1, 2019, REVISED MAY 1, 2020) VA TECHNICAL INFORMATION LIBRARY (TIL) DIVISIONS 26 AND 27 SPECIFICATIONS VA INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES (VERSION 3.0)

AutoCAD SHX Text NEW CEILING PENDANT LIGHTS. LOW CASE LETTER INDICATES SWITCH CONTROL DESIGNATION. UPPER CASE LETTER INDICATES FIXTURE TYPE.

AutoCAD SHX Text F

AutoCAD SHX Text a

AutoCAD SHX Text VOLTAGE DROP FOR ANY BRANCH CIRCUIT AT THE FARTHEST OUTLET SHALL BE NO MORE THAN 3%. FOR 120VAC, 20A CIRCUIT, PROVIDE #10 AWG CONDUCTORS IF CABLE LENGTH IS LONGER THAN 100 FEET AND PROVIDE #8 AWG CONDUCTORS IF CABLE LENGTH IS LONGER THAN 175 FEET. FOR 277VAC, 20A CIRCUIT, PROVIDE #10AWG CONDUCTORS IF CABLE LENGTH IS LONGER THAN 230 FEET. THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET SHALL NOT EXCEED 5%.

AutoCAD SHX Text J

AutoCAD SHX Text

GFI

AutoCAD SHX Text

OS

AutoCAD SHX Text

DS

AutoCAD SHX Text E

AutoCAD SHX Text EXISTING CEILING RECESSED 2'X4' LIGHT FIXTURE. LETTERS INDICATE: E - EXISTING LIGHTING FIXTURE TO REMAIN; ED - EXISTING LIGHTING FIXTURE TO BE DISCONNECTED AND REMOVED; ER - EXISTING LIGHTING FIXTURE TO BE RELOCATED.

AutoCAD SHX Text EXISTING CEILING RECESSED COMPACT FLUORESCENT LAMP (CFL) DOWNLIGHT TO BE DISCONNECTED AND REMOVED.

AutoCAD SHX Text

EXISTING CEILING MOUNTED EXIT SIGN LIGHTING TO BE DISCONNECTED AND REMOVED.

AutoCAD SHX Text EXISTING WALL MOUNTED LIGHTING SWITCH TO BE DISCONNECTED AND REMOVED. SWITCH BACKBOX TO REMAIN FOR REUSE.

AutoCAD SHX Text

FLOOR MOUNTED.

AutoCAD SHX Text

GROUND FAULT PROTECTION.

AutoCAD SHX Text

ISOLATED GROUND.

AutoCAD SHX Text

WALL MOUNTED, 48" AFF.

AutoCAD SHX Text

WEATHERPROOF

AutoCAD SHX Text F

AutoCAD SHX Text

GF

AutoCAD SHX Text

IG

AutoCAD SHX Text W

AutoCAD SHX Text

WP

AutoCAD SHX Text

SYMBOL MODIFIERS

AutoCAD SHX Text

A AMPERES

AutoCAD SHX Text

AC ALTERNATING CURRENT

AutoCAD SHX Text

AFF ABOVE FINISHED FLOOR

AutoCAD SHX Text

AFFF AQUEOUS FILM FORMING FOAM

AutoCAD SHX Text

AIC AMPERES INTERRUPTING CAPACITY

AutoCAD SHX Text

BIL BASIC IMPULSE LEVEL

AutoCAD SHX Text

C CONDUIT

AutoCAD SHX Text

EC EMPTY CONDUIT

AutoCAD SHX Text

EMT ELECTRICAL METALLIC TUBING

AutoCAD SHX Text

EXP EXPLOSIONPROOF

AutoCAD SHX Text

FACP FIRE ALARM CONTROL PANEL

AutoCAD SHX Text

G GROUND

AutoCAD SHX Text

GND GROUND

AutoCAD SHX Text

GRS GALVANIZED RIGID STEEL CONDUIT

AutoCAD SHX Text

HID HIGH INTENSITY DISCHARGE

AutoCAD SHX Text

K KILO

AutoCAD SHX Text

LC LIGHTING CONTACTOR

AutoCAD SHX Text

MAX MAXIMUM

AutoCAD SHX Text

MIN MINIMUM

AutoCAD SHX Text

N NEUTRAL

AutoCAD SHX Text

NIC NOT IN CONTRACT

AutoCAD SHX Text

NTS NOT TO SCALE

AutoCAD SHX Text

RMS ROOT MEAN SQUARE

AutoCAD SHX Text

SYM SYMMETRICAL

AutoCAD SHX Text

V VOLTS

AutoCAD SHX Text

VFD VARIABLE FREQUENCY DRIVE

AutoCAD SHX Text

W WIRE (OR WATT)

AutoCAD SHX Text

XFMR TRANSFORMER

AutoCAD SHX Text

EF EXHAUST FAN

AutoCAD SHX Text

UON UNLESS OTHERWISE NOTED

AutoCAD SHX Text

OC ON CENTER

AutoCAD SHX Text

EMCS ENERGY MANAGEMENT CONTROL SYSTEM

AutoCAD SHX Text

IG ISOLATED GROUND

AutoCAD SHX Text

DDC DIRECT DIGITAL CONTROL

AutoCAD SHX Text

CPT CONTROL POWER TRANSFORMER

AutoCAD SHX Text

GFP GROUND FAULT PROTECTION

AutoCAD SHX Text

H PHASE OR HOT CONDUCTOR

AutoCAD SHX Text

MCP MOTOR CIRCUIT PROTECTOR

AutoCAD SHX Text

AFG ABOVE FINISHED GRADE

AutoCAD SHX Text

EP EXPLOSION-PROOF

AutoCAD SHX Text

MTE MOBILE TAIL ENCLOSURE

AutoCAD SHX…