Attachment_B_-_Davit_System_Sheet.pdf

PDF 13 MB Posted

Attached to
Structural Engineering Services for Retrofit Fall Protection Designs
Solicitation number
2026-RFQ-183
Issued by
Pierce County, Washington

About this file

This document is a technical specification sheet for the DBI-Sala Davit System, submitted as an attachment to Pierce County's structural engineering services contract opportunity in Washington. The sheet provides detailed specifications and performance data for the Davit mast and extension system that will be used in the fall protection retrofit project. The specification includes product dimensions, load capacities, material specifications, and installation requirements necessary for the structural engineers to develop stamped design details for mounting sleeve installations across approximately 105 existing sites within Pierce County.

The Davit System Sheet serves as the reference standard that selected engineering firms must utilize when evaluating structural requirements and designing the approximately 194 mounting sleeves for DBI-Sala Davit masts and extensions. This technical documentation is essential for ensuring that all retrofitted fall protection systems meet manufacturer specifications and load requirements, and that the resulting structural designs developed by the consultant will properly accommodate the specified equipment at each project site.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LADDER

.9

.5

11.5'

.5

1' 1.

7'

DAVIT ARM

RADIUS

PROPOSED CORE MOUNT SLEEVE #6 REBAR @ 3.5" O.C.

(4 PLACES), SET 2"

CLEAR FROM BOTTOM

12" OF CONC. SLAB

SECTION

#6 REBAR @ 8" O.C. E.W.

(TYP.), SET @ CENTER OF

12" CONC. SLAB SECTION

#5 REBAR (4 PLACES), SET

ABOVE LOWER #6 REBAR,

ABOUT 3.5" ABOVE

BOTTOM OF 12" CONC.

SLAB SECTION

ACCESS

HATCH

DOORS

SLUICE GATE VALVE

STEM LOCKING BOX

2.4'

6.

6'

3'

1'

1.

7'

9.25"

2.75"

ACCESS HATCH DOOR

DAVIT ARM

PROPOSED CORE

MOUNT SLEEVE

#6 REBAR @ 3.5' O.C. (4

PLACES), SET 2' CLEAR

FROM BOTTOM 12" OF

CONC. SLAB SECTION

#6 REBAR @ 8" O.C. E.W.

(TYP.), SET @ CENTER OF

12" CONC. SLAB SECTION

SEE ALTERNATE SECTION VIEW, SHEET DT-01

1'2.2'

DAVIT ARM

RADIUS

LADDER

PROPOSED

FLUSH MOUNT

SLEEVE

2.4'

12.9'

7.

8'

6.

7'

2.4'

1'2.2'

8"

DAVIT ARM

PROPOSED FLUSH

MOUNT SLEEVE WITH

ANCHOR BOLTS

SEE DETAIL 1, SHEET DT-01

P l o t

D a t e

N

U

T L

V

O L

D o c u m e n t s S e w e r s E

N G

C o l l e c t i o n S y s t e m C u s t o m e r S u p p o r t F i l e s M

O

S u p p o r t F a l l P r o t e c t i o n U p g r a d e

C

A D

P

S

D a v i t

S y s t e m d w g

F i l e

L o c a t i o n

L a y o u t

P P

B y s c o n d o n

30% PLAN REVIEW

PRELIMINARY PLANS

Pierce County Planning & Public Works Department Sewer Division Environmental Services Building 9850 64th Street West University Place, Washington 98467-1078 An APWA Accredited Agency

PROJECT NO.: DESIGNED BY:

DWG NAME:

PROJECT PHASE: SURVEYED BY:

PLOTTED: CHECKED BY: DRAWN BY:

DATE

27/1/2021

PROJECT # P- SC

AC

SC & ED

PS82 Davit System.dwg

PRELIMINARY DESIGN

SHEET

OF

PP-01

NO.

NAVD 88 ASSUMED

DATUM:

TOWNSHIP, RANGE, SECTION:

2.)

1.)

NO. DATE BY APPROVEDREVISIONS

Xref ..\..\Blocks\PE Stamp\PE-STEVE STAMP.dwg

Know what's below.

before you dig.Call

R

PS 82 THE KNOLLS PUMP STATION

DAVIT INSTALLATION PROJECT

PUBLIC SANITARY SEWER PUMP STATION

PLAN AND PROFILE VIEWS

PLAN VIEW

WET WELL SLAB

PLAN VIEW

VALVE VAULT SLAB

NOT TO SCALE

C

D T

A

B

A

SECTION - WET WELL SLAB

B

SECTION - VALVE VAULT SLAB

N.T.S.N.T.S.

P l o t

D a t e

N

U

T L

V

O L

D o c u m e n t s S e w e r s E

N G

C o l l e c t i o n S y s t e m C u s t o m e r S u p p o r t F i l e s M

O

S u p p o r t F a l l P r o t e c t i o n U p g r a d e

C

A D

P

S

D a v i t

S y s t e m d w g

F i l e

L o c a t i o n

L a y o u t

D T

B y s c o n d o n

30% PLAN REVIEW

PRELIMINARY PLANS

Pierce County Planning & Public Works Department Sewer Division Environmental Services Building 9850 64th Street West University Place, Washington 98467-1078 An APWA Accredited Agency

PROJECT NO.: DESIGNED BY:

DWG NAME:

PROJECT PHASE: SURVEYED BY:

PLOTTED: CHECKED BY: DRAWN BY:

DATE

27/1/2021

PROJECT # P- SC

AC

SC & ED

PS82 Davit System.dwg

PRELIMINARY DESIGN

SHEET

OF

DT-01

NO.

NAVD 88 ASSUMED

DATUM:

TOWNSHIP, RANGE, SECTION:

2.)

1.)

NO. DATE BY APPROVEDREVISIONS

Xref ..\..\Blocks\PE Stamp\PE-STEVE STAMP.dwg

Know what's below.

before you dig.Call

R

PS 82 THE KNOLLS PUMP STATION

DAVIT INSTALLATION PROJECT

PUBLIC SANITARY SEWER PUMP STATION

DETAIL VIEWS

NOT TO SCALE

SECTION - CORE MOUNT SLEEVE FIXED FLUSH MOUNT SLEEVE

N.T.S. N.T.S.1

9.25"

2.75"

STAINLESS STEEL 3M™

CORE MOUNT SLEEVE

(MODEL #8510110)

CORE THROUGH

(2) #6 REBAR

SET AT CENTER

OF 12" CONC.

SLAB SECTION

DAVIT ARM

0.5"

4" MIN.

EMBEDMENT

DEPTH8"

26" 12" 1.25"0.5"

12"

2"

(4) #6 REBAR,

SET 2" CLEAR

FROM BOTTOM

OF 12" CONC.

SLAB SECTION

12"

18"

4"4"

DAVIT STAINLESS STEEL SLEEVE

CAP (MODEL #8510827).

ENSURE TIGHT FITTING.

EX. HATCH

OPENING

EX. HATCH

OPENING

DAVIT ARM

STAINLESS STEEL 3M™

FLUSH MOUNT SLEEVE

(MODEL #8512827)

#6 A706/GR60 E.W.

NOTE:

VAULT INFORMATION

IS FROM SUBMITTAL

DRAWINGS.

BOLT HARDWARE 5/8-INCH NOMINAL ROD DIAMETER (316

SS) WITH STAINLESS STEEL WASHERS AND NUTS. USE

HIT-RE 500 V3 EPOXY ADHESIVE IN FOUR HOLES AND

INSTALL PER MANUFACTURER'S RECOMMENDATIONS. A

MINIMUM LENGTH OF 1/4-INCH SHALL BE LEFT ABOVE THE

TOP OF THE STAINLESS STEEL NUT; GRIND EXCESS FLUSH

WITH PLATE.

DAVIT STAINLESS STEEL SLEEVE

CAP (MODEL #8510827).

ENSURE TIGHT FITTING.

EX. ASPHALTEX. ASPHALT

EPOXY HOLE AROUND SLEEVE SIDES AND BOTTOM

PER MANUFACTURER'S RECOMMENDATIONS.

EPOXY SHALL BE FASTENAL FC10+ FAST CURE

ACRYLIC ADHESIVE (PART # 11562802, 10 OZ

TUBE) OR EQUIVALENT. REMOVE ALL DEBRIS

FROM HOLE PRIOR TO INSTALLATION.

EPOXY HOLE AROUND SLEEVE SIDES PER

MANUFACTURER'S RECOMMENDATIONS.

EPOXY SHALL BE FASTENAL FC10+ FAST CURE

ACRYLIC ADHESIVE (PART # 11562802, 10 OZ

TUBE) OR EQUIVALENT. REMOVE ALL DEBRIS

FROM HOLE PRIOR TO INSTALLATION.

2"

C

PP-01

8" MIN.

8" MIN.

INNER CONCRETE

EDGE

INNER CONCRETE

EDGE

8" MIN.

8" MIN.

File details come from the government source that posted it. Updated .