ATTACHMENT B - BATTERY OPERATED SHOWER CHAIR - PRODUCT DESCRIPTION.docx
DOCX document 173 KB Posted
- Attached to
- 6515--NX EQ Battery Operated Shower Chair
- Solicitation number
- 36C10G22Q0093
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ATTACHMENT C - BATTERY OPERATED SHOWER CHAIR - CONTRACT ADMINISTRATION.docx | DOCX document | |
| 36C10G22Q0093.docx | DOCX document | |
| ATTACHMENT D - BATTERY OPERATED SHOWER CHAIR - CONTRACT CLAUSES.docx | DOCX document | |
| ATTACHMENT F - BATTERY OPERATED SHOWER CHAIR - REPORTING TOOL.xlsx | XLSX spreadsheet | |
| ATTACHMENT A - BATTERY OPERATED SHOWER CHAIR - PRICE LISTS.xlsx | XLSX spreadsheet | |
| ATTACHMENT E - BATTERY OPERATED SHOWER CHAIR - SOLICITATION PROVISIONS.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF VETERANS AFFAIRS
VETERANS HEALTH ADMINISTRATION
PRODUCT DESCRIPTION
For
NON-EXPENDABLE EQUIPMENT:
BATTERY OPERATED SHOWER CHAIR
Prepared By:
Strategic Acquisition Center (SAC) Department of Veterans Affairs 10300 Spotsylvania Avenue, Suite 400 Fredericksburg, VA 22408
1. SCOPE OF WORK:
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the BATTERY OPERATED SHOWER CHAIR product line as a candidate for a VA-wide (otherwise referred to as “national”) single award Requirements contract.
Battery Operated Shower Chairs are height adjustable medical hygiene chairs that can be tilted backward and forward for patient comfort during showering. It is designed to offer a safe and dignified bathing experience for patients who lack mobility. The swinging armrests, removeable footrests, and adjustable headrest are all ergonomically designed to keep the patient securely supported while seated as well as allow caregivers to provide safe patient transfers. Battery Operated Shower Chairs also facilitate toileting with an opened seat and attachable commode pan.
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Battery Operated Shower Chairs to be used by clinicians throughout the VA Medical Centers and facilities. The period of performance is for one (1) 12-month base period with four (4) 12-month option periods.
2. REQUIREMENT
This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” which requires the quoter to indicate that each product being offered as an “equal” product to the EZ1000® Battery Operated Shower Chair, which are manufactured by EZ Way, Inc.
The Government's intent for this Requirements contract is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. The Government may through bilateral modification, add or remove items to this contract that are determined to be within scope of the solicited product line, not limited to the original items awarded. Additionally, any discontinued items may be replaced via future contract modification by the replacement part identified by the OEM, so long as the replacement part serves the same clinical purpose and function as the originally awarded item. Furthermore, any new technology that is presented during performance of this contract may be evaluated by the Government for inclusion into the contract, via bilateral modification. This new technology must be determined to be within scope of the original contract.
For each equal product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The quoter must also clearly identify the item by brand name (if any) and make/model number. Finally, the quoter must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer, and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.
| CONTRACT LINE ITEMS |
| MANUFACTURER |
| PART NUMBER |
| DESCRIPTION |
| BASE YR |
| OY 1 |
| OY 2 |
| OY 3 |
| OY 4 |
| 0001 |
| EZ Way, Inc. |
| EZ1000 |
| Battery Operator Shower Chait/Toilet Chair, Height adjustable and reclining, seat belt, plastic toilet bucket with cover, Comfort Adjustable Footrests |
| 150 |
| 200 |
| 200 |
| 200 |
| 150 |
The Department of Veterans Affairs (VA) is seeking vendors who can provide Battery Operated Shower Chairs as listed above or equal commodities which meet all of the following salient characteristics. Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Vendors are asked to quote any additional product that may be beneficial. These items must be captured in the vendors’ pricing volume.
| SC # |
| SALIENT CHARACTERISTICS |
| METHOD OF EVALUATION |
| SC CROSS-WALK (PAGE#) |
| SC 1 |
| 440 pounds patient weight capacity. |
| Literature Review |
| SC 2 |
| Must provide powered height adjusting to allow transfers from wheelchairs |
| Literature Review |
| SC 3 |
| Must have a motorized recline feature. |
| Literature Review |
| SC 4 |
| Must have either a plug for recharging or 2 batteries and a wall charger. |
| Literature Review |
| SC 5 |
| Must have an emergency stopping feature |
| Literature Review |
| SC 6 |
| Must have head and/or neck support while reclining |
| Literature Review |
| SC 7 |
| Must have lockable wheels on each side |
| Literature Review |
| SC 8 |
| Must have cushioned seats. |
| Literature Review |
| SC 9 |
| Must be Intended for use in showers |
| Literature Review |
| SC 10 |
| Must have operating controls either on both sides of the chair or on the remote control |
| Literature Review |
| SC 11 |
| Must have an opened seat for toileting over a commode and hold an attachable waste pan |
| Literature Review |
| SC 12 |
| Must have swinging armrests to allow lateral patient transfer. |
| Literature Review |
| SC 13 |
| Must have a battery power Indicator |
| Literature Review |