Attachment B 36C24823Q1324
Statement of Need
Background:
The Malcom Randall VA Medical Center have a brand name or equal procurement for two (2) Ultrasonic Generator. The existing Generator is at the end of their lifecycle and need to be replaced.
Salient Characteristics:
The Generator is used in Urology Small procedure clinic and Urology OR. The electrosurgical generator is used in physician’s offices and surgi-centers. It should provide unsurpassed performance, ®flexibility, reliability, and user convenience in one compact pack.
The Generator shall meet or exceed the following specifications, have the following operating features and must be compatible:
• Power Capabilities o Up to 120 watts of Pure Cut @ 500 O.
o Up to 90 watts of Blend @ 800 O.
o Up to 80 watts of Coagulation @ 1000 O.
o Up to 40 watts of Fulguration @ 1000 O.
o Up to 30 watts of Bipolar @ 200 O.
• Two Levels of Coagulation o Pinpoint coagulation provides precise control of bleeding in localized areas.
o Fulguration provides greater control of bleeding in highly vascular tissue over broader tissue surface areas.
• Return Electrode Monitoring System o The unit incorporates a return electrode contact quality monitoring system (RECQMS). This system determines the type of patient return electrode attached (single plate or split plate).
o It also continuously monitors the contact impedance between the patient and the split plate patient return electrode.
o Contact impedance is only monitored when approved split plate patient return electrodes are used.
• Memory o The unit automatically powers up to the Cut and Coag modes and their last selected power settings. If the Blend, Fulguration or Bipolar mode is selected, the unit will default to that modes’ last set power setting.
• Floating RF Output:
o This minimizes the potential of alternate site burns.
• Standard Front Panel Connectors:
o These connectors accept the latest monopolar and bipolar instruments.
Attachment B 36C24823Q1324
Statement of Need
• Self-Diagnostics:
o These diagnostics continually monitor the unit to ensure proper performance.
o Whenever they detect a problem, medical personnel receive audible and visual alarm responses, and the output is suspended until the alarm condition is cleared.
Delivery:
• Vendor shall deliver equipment no later than 30-days from the date of award.
• One unit to be delivered to each of the following sites Monday – Friday (Excluding
National Holidays), 8am – 4:30pm:
o Malcom Randall VA Medical Center – Warehouse
1601 SW Archer Rd.
Gainesville, FL 32608
File details come from the government source that posted it. Updated .