Attachment A - Special Provisions~41.pdf
PDF 4 MB Posted
- Attached to
- I205 SB Ramp 12 & 12A Pavement Repair
- Solicitation number
- S-73000-00012994
- Issued by
- Clackamas County, Oregon
About this file
The document is a Special Provisions file for a highway maintenance project issued by the Oregon Department of Transportation (ODOT) in Salem, Oregon. The project involves a 3" grind and inlay pavement repair on I205 Southbound Ramp 12 and 12A located on the East Portland Freeway in Clackamas County. The work scope includes furnishing and placing Level 4, ½" Dense ACP Mixture, cold plane pavement removal at 3-inches, applying tack coat, installing temporary and permanent pavement markings, and implementing traffic control. The project is scheduled to be substantially completed by June 15, 2025, with a final completion date of June 30, 2025.
The contract is classified as a State Project and will follow the 2024 Oregon Standard Specifications for Construction. The contractor will be responsible for providing quality control and meeting specific technical requirements, including compaction of at least 91% of the Maximum Assumed Market Density (MAMD). Approximately 2 tons of emulsified asphalt tack coat will be required, and the contractor must use a recently approved ODOT asphalt mix design. The project will involve work on specific highway segments with lane widths varying between mile points 4.92-5.15 and 5.00-5.10, with white line markings to be removed and replaced.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Intent to Award~38.xlsx | XLSX spreadsheet | |
| Attachment B - Bid Pricing Form~33.xlsx | XLSX spreadsheet | |
| Sample Contract - Prineville Janitorial .pdf | ||
| 00012994_Invitation to Bid.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3” GRIND AND INLAY
I205 SB RAMP 12 & 12A PAVEMENT REPAIR
SPECIAL PROVISIONS 2
DESCRIPTION OF WORK
EAST PORTLAND FREEWAY
CLACKAMAS COUNTY
Scope- Contract requires Contractor furnish, place and compact Level 4, ½” Dense ACP Mixture, cold plane pavement removal at 3-inches, provide and apply tack coat, furnish and install temporary pavement markings, furnish and install permanent striping, and traffic control. Comply with the 2024 Oregon Standard Specifications for Construction.
Location of Work—this work will be on the East Portland Freeway (064) in the location as described below.
Highway Direction Ramp Lanes Width Mile Point Range
I205 SB 12A A Varies 5.00-5.10 I205 SB 12 A Varies 4.92-5.15
Above identified areas will be marked with white lines. Remove and replace all striping.
COMPLETION TIME LIMIT
Complete all Work to be done under the Contract not later than June 30, 2025. Substantially complete all Work to be done under the Contract not later than June 15, 2025.
APPLICABLE SPECFICATIONS
2024 OREGON STANDARD SPECIFICATIONS FOR CONSTRUCTION: The 2024 Oregon Standard Specifications for Construction (“Standard Specifications”) include detailed technical specifications that apply to this ITB and resulting Contract. Some sections of the technical specifications are identified and modified below. Sections of the technical specifications not identified below remain applicable to the Contract according to their original terms. Part 00100 of the Standard Specifications (General Conditions) is not applicable to the Contract; however, if a technical specification (Parts 200 and beyond) references a section from Part 00100, that section from Part 00100 applies to the Contract for purposes of supporting and giving full effect to the technical specification. The Standard Specifications are available online:
http://www.oregon.gov/ODOT/HWY/SPECS/Pages/standard_specifications.aspx
All number references in these Special Provisions shall be understood to refer to the Sections and subsections of the Standard Specifications bearing like numbers and to Sections and subsections contained in these Special Provisions in their entirety.
SPECIAL PROVISIONS 3
CLASS OF PROJECT
This is a State Project.
SPECIAL PROVISIONS 4
TABLE OF CONTENTS FOR SPECIAL PROVISIONS
SECTION 00210 - MOBILIZATION
SECTION 00220 - ACCOMMODATIONS FOR PUBLIC TRAFFIC
SECTION 00221 - COMMON PROVISIONS FOR WORK ZONE TRAFFIC
CONTROL
SECTION 00222 – TEMPORARY TRAFFIC CONTROL SIGNS
SECTION 00223 - WORK ZONE TRAFFIC CONTROL LABOR AND VEHICLES
SECTION 00224 - TEMPORARY TRAFFIC CHANNELIZING DEVICES
SECTION 00225 - TEMPORARY PAVEMENT MARKINGS
SECTION 00280 – EROSION AND SEDIMENT CONTROL
SECTION 00290 - ENVIRONMENTAL PROTECTION
SECTION 00310 - REMOVAL OF STRUCTURES AND OBSTRUCTIONS
SECTION 00620 - COLD PLANE PAVEMENT REMOVAL
SECTION 00730 - EMULSIFIED ASPHALT TACK COAT
SECTION 00744 - ASPHALT CONCRETE PAVEMENT
SECTION 00850 - COMMON PROVISIONS FOR PAVEMENT MARKINGS
SECTION 00865 - LONGITUDINAL PAVEMENT MARKINGS - DURABLE
SECTION 00867 - TRANSVERSE PAVEMENT MARKINGS - LEGENDS AND
BARS
SUPPLEMENTAL SPECIAL PROVISIONS
GUIDELINE FOR PAVEMENT RESTORATION OF DEFECTIVE WORK IN ODOT RIGHT-
OF-WAY
PLANS
STANDARD DRAWINGS
SPECIAL PROVISIONS 5
SECTION 00210 - MOBILIZATION
Comply with Section 00210 of the Standard Specifications.
SECTION 00220 - ACCOMMODATIONS FOR PUBLIC TRAFFIC
Comply with Section 00220 of the Standard Specifications modified as follows:
00220.40(e)(1) Closed Lanes - Replace this subsection, except for the subsection number and title, with the following:
Traffic Lanes may be closed on East Portland Freeway (064) when allowed, shown, or directed during the following periods of time except as specified in 00220.40(e)(2):
Single Lane Closures – One Traffic Lane in a single direction on East Portland Freeway
(064) may be closed during the following times:
• Monday - Friday, between 9:00 p.m. and 5:30 a.m.
• Saturday - Sunday, between 9:00 p.m. and 7:00 a.m.
00220.60(a)(1) Contractor Responsibility – Add the following to the end of the first bullet list:
• Keep the surfaces being used by bicycles free of all dirt, mud, gravel and other harmful material. The surface includes bike paths, bike lanes, roadway shoulders or the outside 6 feet of the roadway. Roadways shall be free of barricades or other objects and all lanes opened to traffic during all the non-restrictive timeframes.
SECTION 00221 - COMMON PROVISIONS FOR WORK ZONE TRAFFIC CONTROL
Comply with Section 00221 of the Standard Specifications modified as follows:
00221.06 Traffic Control Plan - Replace this subsection with the following subsection:
00221.06 Traffic Control Plan –
(a) Traffic Control Plan – Submit the following, 7 Calendar Days before the preconstruction conference:
The Contractor will use a site specific TCP developed by the Contractor and submit Unstamped Working Drawings that include the proposed TCP showing all TCM and quantities of TCD, and the following:
• A temporary pedestrian accessible route plan that includes:
SPECIAL PROVISIONS 6
o Details and features used to provide pedestrian accessibility.
o Pedestrian staging Plans at a scale no smaller than 1 inch = 50 feet.
o Temporary alternate facilities or detour routes for pedestrian traffic.
• Staging sequences and details for Work affecting vehicular, pedestrian, and bicycle traffic.
• Proposed order and duration of the TCM.
• A detailed temporary striping plan if the existing striping is affected.
• PCMS sign locations and messages for advanced warning and for during construction.
• Allowed work days and hours.
SECTION 00222 – TEMPORARY TRAFFIC CONTROL SIGNS
Comply with Section 00222 of the Standard Specifications modified as follows:
00222.40(e) Temporary Sign Placement - Add the following to the end of the bullet list:
• Install a 72 by 24-inch "CONSTRUCTION VEHICLE DO NOT FOLLOW" (CW23-14) sign on rigid substrate on the back of all material or Equipment delivery vehicles.
• At least seven Calendar Days before East Portland Freeway (064) closure, place one or more PCMS displaying the following message as shown, or as directed:
Panel 1 Panel 2 (Name/# of highway) LANE CLOSURE (Location) (Time Frame) LANE CLOSURE (Time Frame)
00222.80 Measurement - Replace this subsection, except for the subsection number and title, with the following:
No extra measurement will be made for this work.
SECTION 00223 - WORK ZONE TRAFFIC CONTROL LABOR AND VEHICLES
Comply with Section 00223 of the Standard Specifications.
SECTION 00224 - TEMPORARY TRAFFIC CHANNELIZING DEVICES
Comply with Section 00224 of the Standard Specifications.
SPECIAL PROVISIONS 7
SECTION 00225 - TEMPORARY PAVEMENT MARKINGS
Comply with Section 00225 of the Standard Specifications modified as follows:
00225.42 Temporary Pavement Markings - Replace the sentence that begins “Temporary Pavement Markings may be placed using…” with the following sentence:
Temporary pavement markings may be placed using temporary paint only.
SECTION 00280 – EROSION AND SEDIMENT CONTROL
Comply with Section 00280 of the Standard Specifications modified as follows:
00280.00 Scope - Replace the paragraph that begins "This Work also consists of providing temporary …" with the following paragraph:
This Work also consists of providing temporary erosion and sediment control (ESC) measures and furnishing, installing, moving, operating, maintaining, inspecting, and removing ESC throughout the Project area according to the Standard Drawings, the erosion and sediment control plan (ESCP), the Specifications, or as directed, until the site is permanently stabilized. Included also is the monitoring of weather, of stormwater and receiving waters, the reporting of monitoring observations, the reporting of corrective actions (when necessary) and the updates and revisions of the ESCP, including ESCP cover sheet, necessary to keep it representative of current site conditions and compliant with the 1200- CA permit if applicable.
Delete the paragraph that begins “When contaminants, pollutants or hazardous materials…”.
00280.06 Erosion and Sediment Control Manager - Delete this subsection.
00280.62 Inspection and Monitoring - Replace this subsection, except for the subsection number and title, with the following:
Inspect the Project Site and all ESC devices for potential erosion or sediment movement on a weekly basis and when 1/2 inch or more of rainfall occurs within a 24-hour period, including weekends and holidays.
If a significant noncompliance or serious water quality issue occurs that could endanger health or the environment, verbally report it to the Engineer within 24 hours.
00280.80 Measurement - Replace this subsection, except for the subsection number and title, with the following:
No extra measurement will be made for this work.
00280.90 Payment – Replace this subsection, except for the subsection number and title, with the following:
SPECIAL PROVISIONS 8
No separate or additional payment will be made for erosion and sediment control.
SECTION 00290 - ENVIRONMENTAL PROTECTION
Comply with Section 00290 of the Standard Specifications modified as follows:
00290.90 Payment – Replace this subsection, except for the subsection number and title, No separate or additional payment will be made for environmental protection.
SECTION 00310 - REMOVAL OF STRUCTURES AND OBSTRUCTIONS
Comply with Section 00310 of the Standard Specifications modified as follows:
00310.90 Payment - Replace this subsection, except for the subsection number and title, with the following:
No separate or additional payment will be made for removal or disposal Work included in Section 00330 according to 00310.02.
SECTION 00620 - COLD PLANE PAVEMENT REMOVAL
Comply with Section 00620 of the Standard Specifications modified as follows:
00620.43 Maintenance Under Traffic - Replace this subsection, except for the subsection number and title, with the following:
Traffic is not allowed on the cold planed surface. Before opening the area to traffic, pave the surface according to 00744.51.
SECTION 00730 - EMULSIFIED ASPHALT TACK COAT
Comply with Section 00730 of the Standard Specifications modified as follows:
00730.11 Emulsified Asphalt – Replace the sentence that begins “Furnish CSS-1, CSS- 1h…” with the following sentence:
Furnish CSS-1, CSS-1h, CMS-2, CMS-2S, CMS-2h, CRS-1, CRS-2, HFRS-2, HFMS-2 or HPTC as selected by the Contractor.
SPECIAL PROVISIONS 9
00730.90 Payment - Replace this subsection, except for the subsection number and title, No separate or additional payment will be made for Emulsified Asphalt tack coat.
Approximately 2 Tons of Emulsified Asphalt in tack coat will be required on this Project.
SECTION 00744 - ASPHALT CONCRETE PAVEMENT
Comply with Section 00744 of the Standard Specifications modified as follows:
00744.11(a) Asphalt Cement - Add the following to the end of this subsection:
Provide Level 4 grade asphalt cement for this Project.
00744.16 Sampling and Testing - Replace this subsection, except for the subsection number and title, with the following:
For each 1,000 Tons of placement, have a CAT I perform a minimum of one of each of the following test methods as modified in the MFTP:
• Asphalt Content - AASHTO T 308 with ODOT TM 323 determined Calibration Factor
• Gradation - AASHTO T 30
• Mix Moisture - AASHTO T 329
• Maximum Specific Gravity - AASHTO T 209
• Field Compacted Gyratory Specimens - ODOT TM 326
When less than 1,000 Tons of mix is placed in a Day, perform a minimum of one series of tests per Day. Provide test results to the Engineer by the middle of the following work shift.
The Engineer may waive the requirement for any of AASHTO T 308, AASHTO T 30, AASHTO T 329, and ODOT TM 326 on a daily basis. The Engineer may waive the requirement for AASHTO T 209 when less than 500 Tons of ACP is placed in a single work shift.
Provide samples or split samples to the Engineer when requested.
00744.17 Acceptance - Replace this subsection, except for the subsection number and title, with the following:
If the test result for each mix gradation constituent, asphalt content, and density measurement is within the specification limits, the material will be accepted. If the asphalt content, one or more gradation constituents, or the density measurement are not within the specification limits, the material that is not within the specification limits will be accepted according to 00150.25.
00744.41 Mixing Temperature - Replace the table with the following:
SPECIAL PROVISIONS 10
Temperature, °F Type Maximum Minimum Behind at Mixer Paver
HMAC 350 240
WMAC 350 215
00744.49 Compaction - Replace the paragraph that begins "Determine compliance with…" with the following paragraph:
Determine compliance with density Specifications by random testing of the compacted surface with calibrated nuclear gauges. Determine the density by averaging QC tests performed by a CDT with the nuclear gauge operated in the backscatter mode according to AASHTO T 335 at one random location for each 100 Tons of asphalt concrete placed, but take no less than three tests each shift. Do not locate the center of a density test less than 1 foot from the Panel edge. Calculate MAMD according to ODOT TM 305. The Engineer may waive compaction testing requirements when less than 500 Tons of ACP is placed in a single work shift.
00744.51 Opening Sections to Traffic - Schedule work so that, during the same shift, the surfaces being paved are paved full width and length through the wearing Course before opening to traffic.
SECTION 00850 - COMMON PROVISIONS FOR PAVEMENT MARKINGS
Comply with Section 00850 of the Standard Specifications.
SECTION 00865 - LONGITUDINAL PAVEMENT MARKINGS - DURABLE
Comply with Section 00865 of the Standard Specifications.
SECTION 00867 - TRANSVERSE PAVEMENT MARKINGS - LEGENDS AND BARS
Comply with Section 00867 of the Standard Specifications.
SPECIAL PROVISIONS 11
SUPPLEMENTAL SPECIAL PROVISIONS
1. The quantities in the bid item list are intended to serve only as a guide to bidders and are not to be construed as a guarantee. All quantities are estimated and are for bid purposes only. The quantity for each bid item includes all labor, equipment and materials for all activities associated with this project. The Oregon Department of Transportation (ODOT) reserves the right to adjust quantities and add or delete, as needed.
2. Contractor will be responsible for traffic control measures for all closures, based on approved traffic control plan (TCP). A detour will be required for ramp closures.
3. The total number of PCMS required for the project will be determined by the Contractor’s
TCP.
4. ODOT will obtain the required mobility restriction notice for this work.
5. Contractor to contact the Owner’s Authorized Representative and schedule the Pre- Construction Meeting within the timeframe required in the Contract and must be held at least Seven (7) days prior to the start of work.
6. Asphalt mix to be a recently approved ODOT asphalt mix design, submittal shall be the Oregon Department of Transportation Materials Laboratory approval form.
7. Contractor shall provide weigh slips for each load of ACP material placed in performance of Work under the Contract. Contractor to provide the first weigh slip to the Inspector for review and then Contractor shall collect all other weigh slips during the shift and give the group of them to the inspector at the end of the shift.
8. To prevent rutting or other distortion, protect sections of newly finished dense-graded asphalt from traffic until the surface temperature has cooled below 140°F.
9. Furnish a 12-foot straight edge. Test with a 12-foot straight edge parallel to and perpendicular to the centerline and at joints, as directed. The pavement surface shall not vary by more than ¼ inch. Follow Section 00744.75 of the 2024 Oregon Standard Specifications for Construction for corrective action of pavement roughness.
10. All new transverse joint pavement edges shall be sand sealed. This work will be considered incidental to the bid items.
11. Contractor shall be responsible to provide quality control and quality assurance for the project. The Contractor shall meet the compaction requirement listed in Section 00744.49 of a minimum of 91% of MAMD. The Owner’s Authorized Representative reserves the right to take and re-test material samples, and based upon such test results, to reject any material not meeting the referenced Specifications. It is agreed and understood that the Contractor shall replace all rejected material with material meeting the Specifications at no additional cost to the State.
SPECIAL PROVISIONS 12
12. Contractor is responsible for placing all new lines, legends and markers in the same location and configuration as all existing lines. Cost to control work to meet this responsibility is incidental to the bid items.
13. Defective pavement will be repaired, at no additional cost to the State, according to the Region 1 Maintenance: Guidelines for Pavement Restoration or Defective Work.
14. Contractor’s employees and their subcontractors may not wear clothing, hats, vests, etc. that have the ODOT name or “flying T” symbol.
15. There is public interest in the work. Contractor is advised to use courtesy and respect in any work site interaction with the public and to refer all public relations matters to the ODOT Owner’s Authorized Representative.
16. Contractor shall implement safety policies, procedures and practices in conformance with all applicable local, state and federal laws, rules and regulations including but not limited to:
a. Applicable OSHA safety regulations
b. ANSI Z 133.1 Safety standards agreed upon by ODOT and local jurisdiction The
Manual of Uniform Traffic Control Devices (MUTCD)
c. Any other applicable safety laws, regulations and codes.
17. All equipment utilized during this contract shall be in good and serviceable condition.
18. In addition to the notifications required under the standard specifications and special provisions, contractor will also:
A. At least 72 hours prior to executing lane and/or complete roadway closures on Hwy 064 notify:
i. The ODOT Owner’s Authorized Representative: 503-209-6974
ii. Clackamas County: 503-655-8218
B. At the time of lane and/or complete roadway closures and again when the lane and/or complete roadway is opened on Hwy 064 notify:
i. ODOT Traffic Management Operations Center (TMOC): 503-283-
19. Any illegal camp cleanup required prior to the start of work will be coordinated by
ODOT. The Contractor shall notify the Owner’s Authorized Representative 10 working days before the scheduled start date to allow for the cleanup to be posted and completed. Contractor to account for this time in their schedule. Contractor shall occupy the site and begin work immediately following the camp cleanup. If there is evidence that additional cleanups will be required based on camper presence or personal property found at the site, notify the Owner’s Authorized Representative so it can be scheduled. Contractor may not move or remove any personal property
SPECIAL PROVISIONS 13
from the site. No monetary compensation will be considered for any camp cleanup delay.
20. Any illegal camp cleanup required after the start of work will be coordinated by ODOT. The Contractor shall notify the Owner’s Authorized Representative to allow for the cleanup to be posted and completed. Contractor shall occupy the site and continue work immediately following the camp cleanup. If there is evidence that additional cleanups will be required based on camper presence or personal property found at the site, notify the Owner’s Authorized Representative so it can be scheduled. Contractor may not move or remove any personal property from the site.
Any time delay caused by campers occupying the site after the start of work, when they had not been present prior to the start of work, will be added to the end of the contract. No monetary compensation will be considered for any camp cleanup delay.
21. Correspondence for the project is required to have the project name “I205 SB Ramp 12 & 12A Pavement Repair” in the subject line and copy Amythest Lee:
Amythest.M.Lee@odot.oregon.gov . Correspondence without the project name in the subject line will not be addressed.
22. Do not combine correspondence for multiple contracts, all correspondence needs to be kept separated.
23. The invoices, certified payrolls (if applicable) and project submittals are to be submitted via email to the Owner’s Authorized Representative.
24. Certified Payroll Report file names are to include the project name, contractor or sub-contractor name and week ending date for the report period.
25. Invoices are to have the contract name and contract number listed on them and the following billing address:
ODOT District 2B 9200 SE Lawnfield Rd Clackamas OR 97015
Updated 11/9/2020
Region 1 Maintenance Guidelines for Pavement Restoration or Defective Work
This guideline applies anytime the asphalt saw cut does not fall at a lane line, striping is removed and not replaced in the same location or when defective paving has to be replaced.
Base Objective: Motorist cannot feel the repaired pavement. Prolong the working life of the asphalt pavement and reduce future maintenance costs.
Repair Guidelines:
1. Pavement condition new or like new (1‐3 years old): Complete a 2” grind and inlay with the same Level of ACP required in the contract (Level 3 minimum) for an area that covers the entire lane width of every lane affected by 100 foot long. The length to be centered on the defective/saw cut area if the defective area is small. If the area is larger than 100 feet then complete a 2” grind and inlay with the same Level of ACP required in the contract for an area that covers the entire lane width of every lane affected by the entire length of the defective/saw cut area.
2. Pavement condition anything less than new (3 years or older): Complete a 2” grind and inlay with the same Level of ACP required in the contract (Level 3 minimum) for an area that covers the entire lane width of every lane affected by 50 foot long. The length to be centered on the defective/saw cut area if the defective area is small. If the area is larger than 50 feet then complete a 2” grind and inlay with the same Level of ACP required in the contract for an area that covers the entire lane width of every lane affected by the entire length of the defective area.
3. When there are several smaller areas that are within a short distance of each other complete one continuous repair.
4. The District Manager or their designated representative will determine the limits of the repair based on these guidelines.
Hwym17i Text Box I205 SB Ramp 12 & 12A Pavement Repair 3" Grind and Inlay hwym17i Line hwym17i Text Box North Scale: NTS hwym17i Text Box Exit 12 Begin MP 4.92 hwym17i Text Box Exit 12 End MP 5.15 hwym17i Text Box Exit 12A Begin MP 5.00 hwym17i Text Box Exit 12A End MP 5.10 hwym17i Line hwym17i Line hwym17i Line hwym17i Line
RD360
ADJUSTMENT
MANHOLE FRAME
R D
.d g n
21-JUL-2015N/A
J U
L wearing course
Asph. conc.
base course
Asph. conc.
(Or others listed in ODOT's QPL) as reqd.
Conc. manhole adjustment rings
(See general note 10)
Mortar 2" max.
See Alternate "A"
Raise as dir.
& frame
Manhole cover
C u t li n e
C u t li n e
Finish grade or hoop
#4 bar
" min. (Typ.)2
(Typ.)
3" min.
Thkn. - 2" min.
Asph. conc.
12" min.
Thkn. - 2" min.
Asph. conc.
12" min.
(Min. 12" thkn.)
P.C. concrete
Backfill with early strength
(Min. 12" thkn.)
P.C. concrete
Backfill with early strength
(Or others listed in ODOT's QPL) as reqd.
Conc. manhole adjustment rings
Raise as dir.
See Alternate "A"
(See general note 10)
Mortar 2" max.
or hoop
#4 bar
" min. (Typ.)2
(Typ.)
3" min.
12" min. 12" min.
Finish grade wearing course
Asph. conc.
base course
Asph. conc.
C u t li n e
C u t li n e
& frame
Manhole cover wearing course
Asph. conc.
base course
Asph. conc.
(Min. 12" thkn.)
P.C. concrete
Backfill with early strength
(Or others listed in ODOT's QPL) as reqd.
Conc. manhole adjustment rings
C u t li n e
C u t li n e
12" min. 12" min.
Finish grade & frame
Manhole cover
Raise as dir.
See Alternate "A"
(See general note 10)
Mortar 2" max.
(Typ.)
3" min.
" min. (Typ.)2 or hoop
#4 bar
- 2 each
#4 bar Cut line frame
Manhole cover & frame
Manhole cover &
Cut line
- 2 each
#4 hoop o f t r a v e l
D ir e c ti o n
12" min.
m in
(T yp
Manhole frame adjusment ring
Conc. manhole
Manhole note 10)
(See general
Mortar 2" max.
12. See Std. Dwg. RD356 for manhole covers and frames.
11. See Std. Dwg. RD336 for tracer wire details.
10. Use epoxy for synthetic grade rings.
9. See appropriate manhole standard drawings for details not shown.
8. See Std. Dwg. RD336 for manhole steps details.
7. Finish joint with asphalt seal and sand.
6. Apply tack coat to edges of existing pavement before installing patch.
5. Protect from traffic loading until conc. has cured to 3000 psi.
concrete.
4. Backfill with early strength Portland Cement Concrete. All concrete shall be commercial grade and leveling mortar, as shown.
3. Raise manhole cover and frame to finish grade by installing conc. manhole adjustment rings
2. Saw cut square or circular excavation around manhole 12" min. from manhole frame.
1. Cover manhole with building paper and const. asph. conc. base course and wearing courses.
GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:
SQUARE CUT
PLAN
CIRCULAR CUT
PLAN
METHOD "A"
METHOD "B"
METHOD "C"
ALTERNATE "A"
the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
Standard Drawing, while
The selection and use of this
RD610
DETAILS
PAVEMENT (ACP)
ASPHALT CONCRETE
R D
.d g n
25-JUL-2017N/A
J U
L
1" in 5'
Feather base course Taper 1" in 5'
AT GRAVEL APPROACHES
METHOD OF FEATHERING ACP PAVEMENT
OR BRIDGE ENDS WHEN NOT OVERLAYING THE BRIDGE
ACP PAVEMENT MATCH AT PROJECT ENDS
METHOD OF MATCHING EXTG. ACP INLAY SURFACING
TABLE 1
METHOD A *
METHOD B *
TAPER LENGTHS
ACP wearing course
(When present)
Feather ACP base course
Extg. pvmt.
See "EDGE DETAIL"
Extg. pvmt.
wearing course thkn.
ACP unfeathered
See project plans for method.
Taper (See Table 1)
Cold plane pvmt. removal
Taper (See Table 1)
Cold plane pvmt. removal
Posted Speed Taper Length
1" per 50' 45 mph
1" per 100'> 45 mph
See "EDGE DETAIL"
Extg. pvmt.
wearing course thkn.
ACP unfeathered top ACP base course
Construct non-feathered
(See "EDGE DETAIL")
Top of ACP base, Extg. pvmt.
ACP wearing course
(When present)
Feather ACP base course
Extg. gravel surfacewearing course thkn.
ACP unfeathered
Thkn. - Var. (2" to 0)
Aggr. base
Thkn. - Var. (2" to 0)
(When present)
Asph. conc. base course
(Thkn. as shown on plans)
ACP wearing course
Extg. pvmt.
Thkn. - 2"
(When present)
ACP base course e x tg p v m t.
E d g e o f
See "EDGE DETAIL"
ACP wearing courseExtg. pvmt.
See "EDGE DETAIL"
Extg. A.C. pvmt.
Cold plane pvmt. removal
(Inlay to extg. asphalt conc. pvmt.)
not acceptable
Mill edge as shown
Nom. depth
Sawcut & seal
EDGE DETAIL
the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
Standard Drawing, while
The selection and use of this
RD1010
TYPE 2, 3, 6, 7, 10 AND 11
INLET PROTECTION
R D
.d g n
REMOVED CALC BOOK NUMBERS01-2021
20-JAN-2021N/A
J A
N
01-2021 MOVED NOTES UP FROM OVERLAPPING THE SHEET BORDER
20" min. 20" min.
Flow Flow
Drainage grate
Flo w
Flow water
Filtered water
Filtered
NOT TO SCALE
NOT TO SCALE NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
COMPOST FILTER SOCK OR WATTLE - TYPE 7
GEOTEXTILE/WIRE MESH/AGGREGATE - TYPE 2 PREFABRICATED FILTER INSERT - TYPE 3
SOD PROTECTION - TYPE 6
CURB INLET SEDIMENT DAM - TYPE 10 WATTLE BARRIER WITH FILTER INSERT - TYPE 11
CURB INLET PERSPECTIVE VIEW
AREA DRAIN PERSPECTIVE VIEW
AREA DRAIN PLAN
compost filter socks
Sandbags are not necessary for sandbags to hold wattles in place.
Compost filter sock or wattle. Use
Flo w
Wire tied (Typ.)
grate
Drainage
(Typ.)
Surface flow
3' mi n.
F lo w
Flow
Flow
Curb face inlet
3' mi n.
curb inlet opening to scale to show
Straw wattle not drawn
Insert -Type 3, (not shown)
Prefabricated Filter
Overflow spillway
Catch basin
F lo w
Curb face inlet
Flow vertical bars
Zip-tie to
Flow
Zip-ties over inlet mouth) dam (fit snugly
Curb inlet sediment
Va
r. 3
6" to sediment dam
Curb inlet
3' OC to hold in place end of wattle and
Place a sandbag at each or wattle filter sock
Compost
Inside diameter
12" plans and notes wattle, size varies. See
Compost filter sock or flo w (typ
Su rface not feasible when staking is
Secure with zip-tie around inlet basin
Min. 6' of sodFlow
Flow
Flow
Flow
#5 Rebar
Geotextile insert overlap
Sewn 6"
#5 Rebar
Flow
Grate
Flow overlap
Sewn 6" aggregate
Open graded depth over inlet
Aggregate, 12" min.
Wire mesh
Geotextile at 3' OC in pavement areas
Hold in place with sandbags to prevent sock movement.
3' OC, typ. Tie sock at overlap
2"x2"x36" wooden stakes areas sandbags at 3' OC in pavement movement. Hold in place with
Tie sock at overlap to prevent sock
2"x2"x36" wooden stakes 3' OC, typ.
from entering the catch basin.
as needed to prevent sediment laden water
Adjust, replace or modify the inlet protection site.
filter insert or wattle prior to leaving the wattle to force storm water to flow through side of opening tight against curb. Adjust
Install wattles over opening and 36" to each detail.
Install prefabricated filter insert per Type 3
Type 11 - Wattle barrier with filter insert are combined at a catch basin.
where at-grade inlet grate and curb inlet required for use with inlet filter insert mouth. Curb inlet sediment dam is
Fit curb inlet sediment dam snugly into inlet
Type 10 - Curb inlet sediment dam installations.
use synthetic mesh socks for temporary used safely.
or areas where the larger socks can be
Use 12" to 18" dia sock in non-traffic areas
(Type 7 cont.)
12" compost filter socks necessary for
Sandbags are not hold wattles in place.
Use sandbags to
Sandbags (typ.).
areas.
Use 8" to 12" dia sock on curbside in traffic recommendations (12"min., 36" max.).
Overlap ends of sock per manufacturers of the sock.
6" into ground and flush with the top
Drive 2"x2" wood stakes a minimum of
Type 7 - Compost filter sock
Field fabricated inserts are not allowed.
entering project storm systems.
prevent the potential of sediments accompanied by additional BMP's to overflow are allowed only when
Prefabricated inserts with provisions for manufacturer recommendations.
to the plans, special provisions, and
Install prefabricated filter inserts according
Type 3 - Prefabricated filter inserts
Install aggregate over the geotextile fabric.
structure.
wire mesh and perimeter area around
Place sediment fence geotextile over the
Place the wire mesh over the grate.
Type 2 - Geotextile/wire mesh/aggregate
NOTES:
harvest of the sod of inlets within 36 hours of
Install sod around the perimeter
NOTE:
TM500
STANDARD DETAIL BLOCKS
PAVEMENT MARKING
T M
.d g n
Changed Min. widths for CH, TM, TM-40, and TS07-2020
07-01-2020N/A
DISABLED PARKING DETAIL (white)
4" white edge line
Edge of pavement
17'
1'
20'
4"
Direction of Traffic
36° 36°
3'
4'
36° 3'
4'
LL
L
L
LL
LL
L
LLL
LL
L
TS
LL
LL
L
L
LL
4'
Direc tion o f Tra ffic
36° 3'
L
9'
3'
8" white line
1'
20'
4'
4" 8 " white line
12'12'12'
L For traversable medianL
9'
3'
L
12'
LL
1'
' 6
1'
For Centerline
DLL DLL-2
36°
36° 3'
Direction of Traffic
BYLD
L E G E N D
36°
36°
Direction of Traffic
CH
For lane lines in drop lanes
For lane lines in acceleration/deceleration lanes
40'
40'
40'
10'
10'
40'
For lane extensions and bike lane extensions For lane extensionsFor lane extensions
TM-40
30'10'
8'
40'
20'
30'
10'
40' 40'
30'
30'
(Typ.)
Wheel Stop
YD
NPL
YBWB
TWL
WD-2
NPR
ND
Direction of Traffic
YLD
TM
4 " space
NDW
Thru Traffic Side
WD
D
YW-2W
2'
4" space
36°
36°
L
4" space
4" space
4"
4"
30'
4" YELLOW LINE
4" WHITE BROKEN LINE
4" space
LL
L
L
LL
LL L
L
LL
8'8'
6'6' 6'
2'2'
8'
1' space
8'
4" YELLOW BROKEN LINE
8" WHITE LINE4" WHITE LINE
10'
40'40'
8'
2'
1'
1'
1'
8" WHITE DOTTED LANE LINE4" WHITE DOTTED LANE LINE
Yellow Line Narrow Double
Yellow Line Narrow Double
YIELD LINE (white) for field layout angle orientation for field layout angle orientation for field layout angle orientation striping plans
Lane line dimensions are shown on the Or Thru Traffic Side
Direction Of Traffic, Increasing Stationing
1' WHITE BARS AT 20' SPACING
CHEVRON BARS
BICYCLE YIELD LINE (white)
4" YELLOW LINES
NO-PASS RIGHT
Yellow Line Narrow Double for field layout angle orientation
4" white line
R o u te
A c c e s s ib le w h ite lin e
1' WHITE BARS AT 20' SPACING
TRANSVERSE SHOULDER BARS
4" YELLOW DOTTED LINE
4" white line
1' YELLOW BARS AT 40' SPACING
TRANSVERSE MEDIAN BARS
distance between left turn refuges exceeds 200' For use at painted medians where
Increasing Stationing Increasing Stationing
Yellow Line Narrow Double
2' (Typ.)
8" WHITE DOTTED LINE 4" WHITE DOTTED LINE
1' YELLOW BARS AT 20' SPACING
TRANSVERSE MEDIAN BARS
3' 5"
4" YELLOW LINES
NO-PASS LEFT
4" YELLOW LINES
TWO-WAY LEFT TURN
TWO 4" WHITE LINES
NARROW DOUBLE NO-LANE CHANGE
TWO 4" YELLOW LINES
DOUBLE NO-PASS
TWO 4" YELLOW LINES
NARROW DOUBLE NO-PASS
(thru traffic side )
HC
4.5' min.
min.
4.5' min.
4.5' min.
4.5' the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
TM501
PAVEMENT MARKING
T M
.d g n
Some Detail Blocks moved to new Std. Drawing TM50407-2020
01-03-2022N/A
8'9"
8'9" 8'9"
1'6"
8'9"
8'9"
8'9"
1'6"
8'9"
1'6"
'1
6' 5"
6'
3'4"
6'
6'
6'
8'9"
6'
3'4"
6'
3'4"
6'
1'
1'
1'
1'
6"
6"
6"
1'6"
6"
6'
6" 6"6"
For arrow proportion details, see current version of Standard Highway Signs
For arrow proportion details, see current version of Standard Highway Signs
2. Arrow and letter dimensions nominal, excluding WWA.
1. Center pavement markings within the lane width.
General Note:
For arrow proportion details, see current version of Standard Highway Signs
For arrow proportion details, see current version of Standard Highway Signs version of Standard Highway Signs
For arrow proportion details, see current
For arrow proportion details, see current version of Standard Highway SignsFor arrow proportion details, see current version of Standard Highway SignsFor arrow proportion details, see current version of Standard Highway Signs
For arrow proportion details, see current version of Standard Highway SignsFor arrow proportion details, see current version of Standard Highway Signs For arrow proportion details, see current version of Standard Highway Signs
For arrow proportion details, see current version of Standard Highway Signs
For arrow proportion details, see current version of Standard Highway Signs
For arrow proportion details, see current version of Standard Highway SignsFor arrow proportion details, see current version of Standard Highway Signs
12'
12'
19'
12'
19'
12' 9"
24'
12' 9"
9' 6"
18'
6'
E-SA
WWA
E-LSA
RA RSALSASA
E-LA E-RA
1'
2'
8'
9'
E-RSA E-RALA E-RSLA
11' 11'
1'
1'
1'
RSLA
LA
12' 9"
8'
RALA
6'
19'
8'
12'
RIGHT TURN STRAIGHT LEFT TURN ARROW (white)
LEFT TURN ARROW (white)
RIGHT TURN LEFT TURN ARROW (white)
RIGHT TURN ARROW (white)
WRONG-WAY ARROW (white)
(white)
ELONGATED LEFT TURN STRAIGHT ARROW
(white)
ELONGATED RIGHT TURN STRAIGHT ARROW
ELONGATED LEFT TURN ARROW (white) ELONGATED RIGHT TURN ARROW (white)
ARROW (white)
ELONGATED RIGHT TURN STRAIGHT LEFT TURN
ARROW (white)
ELONGATED RIGHT TURN LEFT TURN
RIGHT TURN STRAIGHT ARROW (white)LEFT TURN STRAIGHT ARROW (white)STRAIGHT ARROW (white)
ELONGATED STRAIGHT ARROW (white)
3'4"
FISH-HOOK LEFT TURN ARROW (white)
F-LA
13'
1'
7'
For arrow proportion details, see the current ODOT Traffic Line Manual
1'
7'
For arrow proportion details, see the current ODOT Traffic Line Manual
1'
7'
For arrow proportion details, see the current ODOT Traffic Line Manual
1'
7'
For arrow proportion details, see the current ODOT Traffic Line Manual
F-SA
16'
1'
For arrow proportion details, see the current ODOT Traffic Line Manual
1'
For arrow proportion details, see the current ODOT Traffic Line Manual
F-RALA F-RSA F-LSA F-RSLA
(white)
FISH-HOOK RIGHT TURN LEFT TURN ARROW
FISH-HOOK STRAIGHT ARROW (white) (white)
FISH-HOOK RIGHT TURN SRAIGHT ARROW
(white)
FISH-HOOK LEFT TURN STRAIGHT ARROW
TURN ARROW (white)
FISH-HOOK RIGHT TURN STRAIGHT LEFT
13' 10"
7'
3'4"
7'
3'4"
16'
3'4"
19' 4"
3'4"
19' 4" 7'
'1
'5 version of Standard Highway Signs
For arrow proportion details, see current
20°
LRA-L LRA-R
Edge Line
LEFT LANE ENDS (white)
LANE REDUCTION ARROW -
20°
Left Edge Line Centerline or
RIGHT LANE ENDS (white)
LANE REDUCTION ARROW -
01-2022
Fish-hook Arrows added, LRA split into LRA-L and LRA-R
Corrected bubble callout of LRA-L and typo in LRA-R the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: June 1, 2025 - November 30, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
TM503
PAVEMENT MARKING
T M
.d g n
Added note for measurement of Standard Crosswalk07-2022
07-08-2022N/A
BIKE LANE STANDARD STENCIL (white)
TWO 1' WHITE BARS
STANDARD CROSSWALK
6'
9'
For letter proportion details, see current version of Standard Highway Signs For letter proportion details, see current version of Standard Highway Signs For letter proportion details, see current version of Standard Highway Signs edge line Yellow to miss wheel tracks) (adjust spacing 3' min. to 5' max.
Install per Standard Drawing TM530 edge line White
P
12"
12"
ON-STREET PARKING DETAIL (white)
ONLY (white)
BUS
12"
SLM
X
24" 24"
4" white lines
1. Arrow, letter, and bike symbol dimensions nominal.
General Note:
SHARED LANE MARKING (white)
Install per Standard Drawing TM530
Pavement (EP) Edge of
EP
Install per Standard Drawing TM530
1' & 8" WHITE BARS
RAMP METER STOP BAR
For proportion details, see current version of Standard Highway Signs Center marking within lane width or as shown
2' WHITE BAR
STOP BAR - LARGE
Install per Standard Drawing TM530
2' WHITE BARS
STAGGERED CONTINENTAL CROSSWALK
1' WHITE BAR
STOP BAR
End Marking
For proportion details, see current version of Standard Highway Signs
For letter proportion details, see current version of Standard Highway Signs
Center marking within lane width
For proportion details, see current version of Standard Highway Signs
For letter proportion details, see current version of Standard Highway Signs
For letter proportion details, see current version of Standard Highway Signs
For proportion details, see current version of Standard Highway Signs
Center marking within lane width
Center marking within lane width Center marking within width of two lanes Center marking within width of two lanesCenter marking within lane width
Center marking within lane width Center marking within lane width
Center marking within lane width
4'
3'
6'6' 6' 6' 6'6' 6'
6"
BIKE RIGHT TURN STENCIL (white)
CW
BS
BIKE LEFT TURN STENCIL (white)
Varies
8'
6"
2'
Varies
BUS (white) SCHOOL - LARGE (white) CROSSING - LARGE (white)
1'
For multi-lane ramp meter applications
S S-2 S-RM
2'
1'
15'
8' 10' 10'
SCH
Direction of Travel
ON
8'
L E G E N D
6'
SCHOOL (white)
SCH-LG CRS-LG
XNG
X-ING (white)
8'
7'
Extend to EP if X<20' placement Verify loop detector (center within EP) 8" white bar
9'8" 19'8" 19'8"
CW-SC
GRN BLE-Gwidth of lane Color full between dotted lines Color full width of lane
3' 4"3' 4"3' 4"
3' 4" 3' 4"
4' 6"
6'
3' 4"
BIKE STENCIL (white)
B
SOLID LINE (green)
GREEN SUPPLEMENTAL BICYCLE LANE
DOTTED LINE EXTENSION (green)
GREEN SUPPLEMENTAL BICYCLE LANE
2'
4'
3'6"
BR BL
BD
2'
2"
6"
5" 6"
2"
BICYCLE DETECTOR MARKING (white)
3' 6"
9' 4"
Center marking within lane width Center marking within lane width
6' 6'
6"
BIKE RIGHT TURN STRAIGHT STENCIL (white)
3' 4"
For proportion details, see current version of Standard Highway SignsFor proportion details, see current version of Standard Highway Signs
BRS BLS
BIKE LEFT TURN STRAIGHT STENCIL (white)
6' 6"
3' 9"
6' 6'
6"
3' 4"
6' 6"
3' 9"
Used for Intersection Bicycle Box applications
Varies Varies
8" white
8" white
8" white
8" white
Place marking within bicycle box, ceneterd with motor vehicle lane width where bicycle acuates the traffic signal
PLace Bicycle Detector Pavement Marking in optimum loction
1'
1' marking to inside of marking
10' measured from inside of the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: June 1, 2025 - November 30, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
TM520
SURFACE INSTALLED PROFILED
METHOD 'A' & METHOD 'D'
DURABLE PAVEMENT MARKINGS
T M
.d g n
07-05-2013N/A
8'
4" or 8" as specified
3' stripe
12'
Plan
Bumps (1 req'd. per dotted line)
10" min. (both ends)
Bumps
2' stripe
PlanPlan
4" or 8" as specified
Profile
Bumps (5 req'd. per dotted lane line)
1" min. (both ends)
1" min. (both ends)
See Detail "A"
27"
Bumps (2 req'd. per dotted lane line)
10' stripe
4"
See Detail "A"
DETAIL "A"
Top of pvmt.
120 mils
DOTTED LINE
SOLID LINEBROKEN LINE
DOTTED LANE LINE
4" (Thermoplastic) 2" To 3" (Methyl Methacrylate)
Top of pvmt.Top of pvmt.
4" (Thermoplastic) 2" To 3" (Methyl Methacrylate)
Top of pvmt.
4" (Thermoplastic) 2" To 3" (Methyl Methacrylate)
Top of pvmt.
4" (Thermoplastic) 2" To 3" (Methyl Methacrylate)
See Detail "A" Profile
4" or 8" as specified
Plan
See Detail "A"
" (500 mils)2 the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
TM521
NON-PROFILED
SURFACE & GROOVE INSTALLED
PAVEMENT MARKINGS
DURABLE & HIGH PERFORMANCE
T M
.d g n
Changed groove width for 4 in. markings07-2021
20-JAN-2023N/A
J A
N
Top of pavement
Marking Width
Thickness Material
SURFACE INSTALLED MARKINGS
Marking Length
A
Width
Marking
Thickness Material
Depth
Groove
Marking Length Taper 3 ± 1 in.
Taper 3 ± 1 in.
General Notes:
Durable Method 'A' & Method 'D'
2) See Standard Specification 00850.46 for marking installation tolerances.
1) See Standard Drawing TM500 and/or project plans for marking length and width dimensions.
B
GROOVE INSTALLED MARKINGS
B
GROOVE INSTALLED GROOVE AND MATERIAL DIMENSIONS
SECTION B - B
Var. 25 mils
Var.
Pavement Marking Material Type Thickness Material
Groove Depth
High Performance
Recess Depth
Marking Material
Pavement Marking Material Type
SECTION A - A
to top of material from top of pvmt.
Recess depth Top of pavement
Durable Method 'A' & Method 'B' & Method 'D'
25 mils High Performance
Thickness
120 mils 220 ± 20 mils 45 ± 5 mils
60 ± 10 mils
SURFACE INSTALLED MATERIAL THICKNESS
Marking width + 1 ± 0.125 In.
01-2023 Changed groove width back to previous width for 4 in. markings the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
TM560
ALIGNMENT LAYOUT: GENERAL
T M
.d g n
Extended accompanied by drawings to include TM50407-2020
07-01-2020N/A
25' max.
25' m ax.
contrasts with pavement surface.
Aerosol paint. Use color that highly
Control Points
50' max.50' max.
' m ax
Control Points
* Control points are placed along the lane line for all longitudinal lines except the following:
lines only For center
1.) Use control points to make continous narrow guideline as specified.
General note:
for a ND line when used as a center line.
A control point layout 4" offset from the lane line is required
50' max.
CONTROL POINT LAYOUT - TANGENT SECTIONS
CONTROL POINT
L
CONTROL POINT LAYOUT - CURVE SECTIONS
L E G E N D
ND
L
1' TYP.
striping plans.
Lane line dimensions are shown on the
L
L
L
L
To be accompanied by Standard Dwg. Nos. TM500 thru TM504 the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with
TM800
PCMS DETAILS
TABLES, ABRUPT EDGE AND
T M
.d g n
12-JUL-2024N/A
J U
L
Freeway
Use aggregate wedge when abrupt edge is 2 inches or greater.
four feet wide protect longitudinal abrupt edge as shown.
When paved shoulders adjacent to excavations are less than
NOTES:
shoulder, as far as practical.
Place cart / generator / power supply off of the on 10' spacing.
Use six tubular markers in shoulder taper outside shoulder, where practical.
Install Flagger Station Lighting beyond the
2" or GreaterExtg. pavement aggregate base rock
Shoulder or message sign (PCMS)
Portable changeable
20'
100'
4' B(III)R
Temp. Plastic Drums
Lighting
Flagger Station
50'
10'
Markers
28" Tubular
Place roll-up signs in advance of barricades.
plaques to the sign face using hook and loop fasteners.
If roll-up signs are used, attach the correct (CW21-9) throughout excavation area at spacings shown.
Continue signing and other traffic control devices
"RIGHT" (CW21-8C) riders with "LEFT" (CW21-8A) riders.
8' B(III)R barricades with 8' B(III)L barricades and replace the
If the excavation is located on left side of traffic, replace the abrupt edges of 1 inch or greater.
or other roadway work. Use abrupt edge signing for longitudinal
Abrupt edges may be created by paving, operations, excavations
GENERAL NOTES FOR ALL TCP DRAWINGS:
for max. spacing.
See TCD Spacing Table
Temp. Plastic Drums for max. spacing.
See TCD Spacing Table
28" Tubular Markers
UNDER TRAFFIC
UNDER CONSTRUCTION
EXCAVATION ABRUPT EDGE SIGN (PCMS) INSTALLATION
PORTABLE CHANGEABLE MESSAGE
LIGHTING DELINEATION
FLAGGER STATION
Sl. 1:3
TAPER TYPES & FORMULAS
TEMPORARY BARRIER FLARE RATE TABLE
TAPER FORMULA
Merging (Lane Closure)
Shifting
Shoulder Closure
Flagging (See Drg. TM850)
Downstream (Termination)
"L"
"L"3 1"L"/3 or
50' - 100'
Varies (See Drawings)
"L"2 1"L"/2 or the Speed from the Tables below:
Use Pre-Construction Posted Speed to select
For Lane closures where W < 10', use "L" value for W = 10'.
Limit spacing adjustments to 30% of the "A" dimension for all speeds.
When necessary, sign spacing may be adjusted to fit site conditions.
Place traffic control devices on 10 ft. spacing for intersection and access radii.
NOTES:
SPEED (mph) MINIMUM FLARE RATE
M I N I M U M L E N G T H S T A B L E
"L" VALUE FOR TAPERS (ft) BUFFER "B" (ft)W = Lane or Shoulder Width being closed or shifted
20:1
19:1
18:1
16:1
14:1
12:1
10:1
9:1
8:1
FREEWAYS
SPEED (mph) W = 12 W = 14 W = 16
TRAFFIC CONTROL DEVICES (TCD) SPACING TABLE
20 - 30
35 - 40
45 - 55
60 - 70 700
100 100
15001000 2640
100 20
Device Spacing (ft)
Max. Channelizing Sign Spacing (ft) SPEED (mph)
A B C
CW21-8A
(As noted)
36x18
C W
(Mount on TSS)
(As needed)
42x18
CW21-8C
OR
C
W
Plaques
CW21-9
Abrupt edge
8' B(III)R 8' B(III)R
mi.4 1 mi.4
1 mi.4
EDGE
ABRUPT
RIGHT
LEFT
(Roll-up sign)
(As needed)
EDGE
ABRUPT 32x11
32x11
32x11
CENTER
RIGHT
LEFT
10≤ W
30≤
W/60, S = Speed, W=WidthS 45: L = WS, Speeds < 45: L = ≥ formula, for Speeds For Shoulder closures where W < 10', use "L" value for W = 10' or calculate "L" using
TYPICAL ABRUPT EDGE DELINEATION
Smart Work Zone Systems Portable Traffic Signals
Detail as shown is used for trailered and non-crashworthy components of:
barricade may be omitted when PCMS is placed behind a roadside barrier.
Use six drums in shoulder taper on 20' spacing. The drums and
Left shoulder, use Type B(III)L Right shoulder, use Type B(III)R Use the appropriate type of barricade panels for PCMS location.
Install PCMS beyond the outside shoulder, when possible.
To be accompanied by Dwg. Nos. TM820 & TM821.
divided highways or freeways when positive protection is not available, or as directed.
Provide a truck mounted attentuator (TMA) to protect the active work area on high speed
Flaggers, Traffic Control Measures, or as directed.
Coordinate and control pedestrian movements through a Temporary Accessible Route using
Combine drawing details to complete temporary traffic control for each work activity.
Do not locate sign supports in locations designated for bicycle or pedestrian traffic.
High speed highways have a pre-construction posted speed of 45 mph or higher.
Low speed highways have a pre-construction posted speed of 40 mph or less.
All other signs mounted on barrier sign supports shall not exceed 12 sq. ft. in total sign area.
All diamond shaped warning signs mounted on barrier sign supports shall be 36" by 36".
background of all temporary warning signs.
Use fluorescent orange sheeting for the All signs are 48" x 48" unless otherwise shown.
to indicate traffic movements.
Arrows shown in roadway are directional arrows sequential arrow boards.
Place a barricade approx. 20' ahead of all shown are the minimum required.
Signs and other Traffic Control Devices (TCD)
07-2022 Added a note for TPARs
07-2024 Added a note for TMAs the current Oregon Standard Specifications.
All materials shall be in accordance with
DATE REVISION DESCRIPTION
OREGON STANDARD DRAWINGS
DATE
SDR
BOOK NO.
CALC.
Effective Date: December 1, 2024 - May 31, 2025
Professional Engineer.
first consulting a Registered and should not be used without sole responsibility…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .