Attachment_A_-_Requirements_-_JMUX.docx

DOCX document 33 KB Posted

Attached to
EC - FI JMUX (SPARE PARTS)
Solicitation number
140R6024Q0095
Issued by

About this file

This document is an attachment titled "Attachment_A_-Requirements-_JMUX.docx" that outlines the requirements for GE JungleMUX spare parts needed by the Bureau of Reclamation. The key details are:

The Bureau of Reclamation requires specific GE JungleMUX spare parts to replenish their existing network communication equipment inventory. The parts must be 100% compatible with the existing GE JungleMUX OC-3 infrastructure, including the listed interface cards/units. The parts must be black in color to match the existing equipment. Specifically required are new service units, paddleboards, OC-3 optical units, and power units, all of which must meet the detailed technical specifications outlined. The parts will be delivered to the Eastern Colorado Area Office in Loveland, CO on Monday through Thursday between 7am and 4pm. This requirement is associated with the federal contract opportunity "EC - FI JMUX (SPARE PARTS)" with Solicitation Number 140R6024Q0095, issued by the Department of the Interior Bureau of Reclamation.

View the file

Other files

File Type Posted
Attachment_B_Pricing_Sheet.xlsx XLSX spreadsheet
Sol_140R6024Q0095.pdf PDF
Attachment_C_-_Clauses_and_Provisions_140R6024Q0095_.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ECAO JungleMUX Spare Parts Supply Requirements

3-20-2023

These JungleMUX parts are required to replenish spare parts stock. In the event of a network communications failure, this equipment is critical for the optical portion of data transmission.

Items will be delivered to the Eastern Colorado Area Office, 11056 West County Road 18E, Loveland, CO 80537. Delivery days are Monday – Thurs 7am-4pm.

Requirements:

1. These parts will be installed into existing GE JungleMUX shelves and must meet the following characteristics:

a. Be 100% compatible with existing GE JungleMUX OC-3 infrastructure that is already in place

b. Be 100% compatible with the following GE JungleMUX interface cards/units which are already in use at other project sites:

i. B86452-01 115 VAC Power Units

ii. B86431-02 48 VDC Power Units

iii. B86448-01 DATA-LS Units

iv. B86445-32 2-Wire FXS Units

v. B86444-04 4-Wire FV Units

vi. B86486-01 CDAX Units

vii. B86418-01 ETHER-100 Units

viii. B86434-02 Service Units

ix. B86432-41 OC-3 Units

c. All cards/units, chassis parts, and panel covers must be black in color to match existing equipment

d. New Service Units and Paddleboards

i. 100% compatible with all parts listed in this salient characteristic list

ii. Provide major and minor JungleMUX alarms

iii. Compatible with GE JungleMUX Network Management System protocol

iv. Paddleboard provides external cabling/wiring connections

e. OC-3 Optical Units

i. 100% compatible with all parts listed in this salient characteristic list

ii. Provide OC-3 level SONET connections

iii. Single-Mode optics capable of at least 30 kM optical distance

iv. LC fiber connectors

v. >20 dB optical gain

vi. Associated data cables for this unit

f. Power Units

i. 100% compatible with all parts listed in this salient characteristic list

ii. Paddleboard provides external wiring/alarm connections

g. Documentation

i. Provide updated/recent unit documentation

File details come from the government source that posted it. Updated .