ATTACHMENT A - PRICE COST SCHEDULE - NX EQ Cryostat Microtomes.xlsx
XLSX spreadsheet 20 KB Posted
- Attached to
- 6640--NX EQ Cryostat Microtomes Federal contract opportunity
- Solicitation number
- 36C10G24Q0095
About this file
This document is a Price Cost Schedule for a federal contract opportunity to purchase Cryostat Microtomes for the Department of Veterans Affairs (VA). The solicitation number is 36C10G24Q0095, and the requirement is for a single-award Requirements contract for LeicaA Cryostat Microtomes or equal products.
The VA is seeking vendors to provide various models of Cryostat Microtomes, including the Leica CM1520, CM1860, CM1860 UV, CM1950, and CM3050 S. Vendors must meet salient characteristics such as cutting range, knife guard, automatic defrost, antiroll device, temperature, and power requirements. Quotes are due by 11:59 PM EST on April 08, 2024, and the ordering period is for a 12-month base year with four 12-month option years. The contract will be awarded on a firm-fixed-price basis, with delivery FOB destination.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C10G24Q0095 0001.docx | DOCX document | |
| ATTACHMENT E - REPORTING TOOL - NX EQ Cryostat Microtomes.xlsx | XLSX spreadsheet | |
| ATTACHMENT B - CONTRACT ADMINISTRATION - NX EQ Cryostat Microtomes.docx | DOCX document | |
| 36C10G24Q0095.docx | DOCX document | |
| ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Cryostat Microtomes.docx | DOCX document | |
| ATTACHMENT C - CONTRACT CLAUSES - NX EQ Cryostat Microtomes.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BNOE - NX EQ Microtomes
| CLIN | Part Number | Brand Name | Item Description | Unit of Measure (UOM) | Quantity Per UOM | Estimated Quantity (Base Year) | Estimated Quantity (Opt Year 1) | Estimated Quantity (Opt Year 2) | Estimated Quantity (Opt Year 3) | Estimated Quantity (Opt Year 4) | Manufacturer Name | Manufacturer Part Number | Item Description | Contractor Part Number (if different from OEM) | Unit of Measure | Quantity per UOM | Delivery Days ARO | Commercial Price | Proposed Unit | |||||||||||||||||
| Price (Base Year) | SLA (3%) | Total Price (Unit Price plus SLA) | ||||||||||||||||||||||||||||||||||
| Base Year | Proposed Unit | |||||||||||||||||||||||||||||||||||
| Price (Option Year 1) | SLA (3%) | Total Price (Unit Price plus SLA) | ||||||||||||||||||||||||||||||||||
| Option Year 1 | Proposed Unit | |||||||||||||||||||||||||||||||||||
| Price (Option Year 2) | SLA (3%) | Total Price (Unit Price plus SLA) | ||||||||||||||||||||||||||||||||||
| Option Year 2 | Proposed Unit | |||||||||||||||||||||||||||||||||||
| Price (Option Year 3) | SLA (3%) | Total Price (Unit Price plus SLA) | ||||||||||||||||||||||||||||||||||
| Option Year 3 | Proposed Unit | |||||||||||||||||||||||||||||||||||
| Price (Option Year 4) | SLA (3%) | Total Price (Unit Price plus SLA) | ||||||||||||||||||||||||||||||||||
| Option Year 4 | Total Evaluated Price (with 3% SLA and estimated quantities) - Base Year | Total Evaluated Price (with 3% SLA and estimated quantities) - Opt Year 1 | Total Evaluated Price (with 3% SLA and estimated quantities) - Opt Year 2 | Total Evaluated Price (with 3% SLA and estimated quantities) - Opt Year 3 | Total Evaluated Price (with 3% SLA and estimated quantities) - Opt Year 4 | Total Evaluated Price | ||||||||||||||||||||||||||||||
| 0001 | CM1520 | Leica | Value‐priced cryostat for routine histology and Mohs surgery. | Each | 10 | 10 | 10 | 10 | 10 | 10 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||||||
| 0002 | CM1860 | Leica | Cryostat for routine histopathology applications. | Each | 10 | 10 | 10 | 10 | 10 | 10 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||||||
| 0003 | CM1860 UV | Leica | Cryostat for routine histopathology applications with UVC for increased user safety. | Each | 10 | 10 | 10 | 10 | 10 | 10 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||||||
| 0004 | CM1950 | Leica | Most popular cryostat for clinical applications combining large capacity with user safety. | Each | 5 | 5 | 5 | 5 | 5 | 5 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||||||
| 0005 | CM3050 S | Leica | Ergonomic cryosectioning in sitting position for time‐consuming jobs. | Each | 2 | 2 | 2 | 2 | 2 | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||||||
| *VENDOR IS TO COMPLETE ALL "YELLOW" HIGHLIGHTED SPACES | *VENDOR IS TO COMPLETE ALL "YELLOW" HIGHLIGHTED SPACES | |||||||||||||||||||||||||||||||||||
| **ARO = Delivery Days After Receipt of Order | **ARO = Delivery Days After Receipt of Order | |||||||||||||||||||||||||||||||||||
| Offerors proposing equivalent product must enter Name of Manufacturer for its proposed solution, Description of Part Number(s), etc. starting at Column L. If offeror’s proposed solution does not require a particular CLIN, vendor shall indicate such by writing N/A, None, or Zero (0). Also, the items priced in Pricing volume must correspond with the items proposed in offeror’s Technical volume as the brand name or equivalent solution. |
File details come from the government source that posted it. Updated .