About this file
This document is a Materials & Part Specifications sheet for the City of Pembroke Pines' Prestressed Concrete Pipe (PCCP) Repair Fittings procurement in Florida. The specification details the procurement of three specific line fitting and adapter items, with a quantity of two for each: a 30" x 24" PCCP Line Stop Fitting, a 30" x 2" IP Blowdown Saddle/IP Outlet, and a 30" LCP Bell x MJ Plain End Adapter. The document provides comprehensive technical specifications for these components, including specific requirements for materials, hardware, coatings, and compliance with AWWA and ANSI standards.
The technical specifications mandate precise requirements for the fittings, including epoxy coating, stainless steel hardware, specific gasket materials, and adherence to dimensional and manufacturing standards. The line stop fittings must be JCM Model 445 or an approved equivalent, with a minimum neck inside diameter thickness of 3/8-inch and custom grout ports for PCCP installations. Blowdown saddles must meet JCM Model 425 specifications and be designed per AWWA C-223. All mechanical joints must comply with specific ANSI/AWWA standards for rubber-gasket joints, bolts, and materials, ensuring high-quality, durable infrastructure components for the municipal water system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_B:_Part_Diagrams.pdf | ||
| PSUT-24-09_Prestressed_Concrete_Pipe_Repair_Fittings_.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Materials & Part Specifications
PROVIDE THE FOLLOWING MATERIALS:
Item QTY
30" x 24" PCCP Line Stop Fitting (PCCP)
30" x 2" IP Blowdown Saddle / IP Outlet (PCCP)
30" LCP Bell x MJ Plain End Adapter (30" LCP Lay Gasket w/ Joint Grout Band Included)
PRODUCT DETAILS:
PCCP LINE STOP FITTINGS AND BLOWDOWN SADDLE / IP OUTLET
A. The PCCP Line Stop Fitting shall be JCM Model 445 or approved equal (see attached detail drawing). Fittings to be epoxy coated with 304SS hardware. The fitting’s neck inside diameter shall be sized to clear the undersized cutter with a minimum thickness of 3/8-inch. Provide custom designed grout ports for PCCP installations.
B. Blowdown Saddle / IP Outlet shall be JCM Model 425 or approved equal. Blowdown Saddles to be designed and fabricated per AWWA C-223.
C. Each mechanical joint on the line stop fitting shall be furnished complete with tee-head bolts and nuts complying with ANSI/AWWA C111/A21.11 "Rubber-Gasket Joints for Ductile-Iron and Gray-Iron Pressure Pipe and Fittings" (latest edition). Tee-head bolts and hex nuts shall be of high strength cast iron. Bolts and nuts to join the two halves of the sleeve together shall be standard carbon steel, hex, or tee-head bolts and nuts which have been galvanized.
D. The line stop fitting, including outlet flanges shall be as dimensioned and thicknesses shall be as required by AWWA/ANSI C110/A21.10
E. Each line stop fitting shall be furnished complete with all necessary split end gaskets, longitudinal gaskets and two-piece (split) steel glands (follower glands held in place by set screws not acceptable). Gasket shall be shipped separately in suitable protective containers.
Material for split end gaskets shall conform to ANSI/AWWA Standard C111/A21.11. Material for longitudinal gaskets shall be rubber conforming to ANSI/AWWA Standard C111/A21.11.