Attachment A-List of Equipment.docx

DOCX document 29 KB Posted

Attached to
J061--Electrical Power Distribution System & Dissolved Gas Analysis Services Federal contract opportunity
Solicitation number
36C25726Q0116
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

This document is an Attachment A listing electrical equipment for calibration and testing across multiple buildings within a VA facility. The comprehensive inventory includes 91 electrical breakers and switchboards located in Buildings 1, 2, 8, 15, 17, 18, 20, 21, 22, and 25, with specifications detailing amperage, voltage (primarily 480V), and specific locations such as main switchboards, generator switchboards, and various panels. Additionally, the document lists 9 transformers from manufacturers like Westinghouse, Square D, and Vantran, ranging from 75 kva to 2000 kva, located in buildings such as the Boiler Plant, Generator room, and Domiciliary.

The related federal contract opportunity is a Department of Veterans Affairs solicitation (36C25726Q0116) titled "J061--Electrical Power Distribution System & Dissolved Gas Analysis Services" under Veterans Health Administration Veterans Integrated Service Network 17, which appears directly aligned with the detailed electrical equipment inventory provided in the attachment.

View the file

Other files for this federal contract opportunity

Other files attached to J061--Electrical Power Distribution System & Dissolved Gas Analysis Services, newest first.
File Type Posted
S02 36C25726Q0116.docx DOCX document
36C25726Q0116_1.docx DOCX document
Service Contract Act WD_2015-5269_rv29_7-8-2025.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT A

List of electrical equipment for calibration and testing:

Building #
Room #
Description
1
Bldg. 15, Main Switchboard Panel
n/a
Main breaker #1, 4 protective relays, 12.5kv volts
2
Bldg. 15, Main Switchboard Panel
n/a
Main breaker #2, XFRM, 4 protective relays, 12.5kv volts
3
Bldg. 15, Main Switchboard Panel
n/a
Main breaker #3, XFRM, 4 protective relays, 12.5kv volts
4
Bldg. 2
n/a
Main breaker #4, XFRM, 4 protective relays, 12.5kv volts
5
Bldg. 2
n/a
Main breaker #5, XFRM, 4 protective relays, 12.5kv volts
6
Bldg. 2
n/a
MCCA Main breaker, 400AMP GE breaker
7
Switchboard M Main
n/a
Main breaker, RL 2000- Amp, 480V
8
Switchboard M Main
n/a
Breaker #2, RL 800- Amp, normal power central, 480V
9
Switchboard M Main
n/a
Breaker #3, RL 800-Amp, transformer D.D.T. #1-85, Electrical Equipment Room #2, 480V
10
Switchboard M Main
n/a
Breaker #4, RL 800-Amp, transformer D.D.T. #3-85, Electrical Equipment Room #3, 480V
11
Switchboard M Main
n/a
Breaker #5, RL 800-Amp, 2nd Floor Lab A/C, 480V
12
Switchboard M Main
B21
Breaker #6, RL 800-Amp, Laundry Equipment and ITS, 480V
13
Switchboard M Main
B13
Breaker #7, RL 800-Amp, 4 banks elev., 480V
14
Switchboard M Main
B12
Breaker #8, RL 800-Amp, Life Safety Branch, 480V
15
Switchboard M Main
B12
Breaker #9, RL 800-Amp, Critical Branch, 480V
16
Switchboard M Main
B12
Breaker #10, RL 800-Amp, Equipment Branch, 480V
17
Switchboard M Main, Bldg. 15
n/a
Breaker #11, RL 800-Amp, Panel HNSG switchgear gen, 480V
18
Switchboard M Main
n/a
Fire pump switchgear, RHX 1600-Amp, 480V
19
Switchboard M Main
n/a
Solar Panels, switchgear, RL 800-Amp, 480V
20
Switchboard M Main
n/a
Spare switchgear, RL 800-Amp, 480V
21
Switchboard M Main
n/a
Spare switchgear, RL 800-Amp, 480V
22
Switchboard M Main
n/a
Spare breaker, RL 2000- Amp, 480V
23
Switchgear Board X-R Main
n/a
Breaker #1, RL 2000-Amp, Main breaker, 480V
24
Switchgear Board X-R Main
n/a
Breaker #2, RL 800-Amp, X-ray breaker, 480V
25
Switchgear Board X-R Main
n/a
Breaker #3, RL 800-Amp, Dental, 48V
26
Switchgear Board X-R Main
n/a
Breaker #4, RL 800-Amp, 2nd Floor X-ray panel, 480V
27
Switchgear Board X-R Main
n/a
Breaker #5, RL 800-Amp, normal power transformer for 3 West, 480V
28
Generator Switchboard
n/a
Breaker #1, LA-1600-Amp, main breaker (bolt in), 480V
29
Generator Switchboard
n/a
Breaker #3, 400-Amp, ATS#2, Critical, 480V
30
Generator Switchboard
n/a
Breaker #4, 400-Amp, ATS#3, equipment, 480V
31
Generator Switchboard
n/a
Breaker #7, 400-Amp, ATS#6, elevators, 480V
32
Generator Switchboard
n/a
Breaker #9, 350-Amp, fire pump, 480V
33
Bldg. 1, Main Facility
B21
Breaker #1, 600-Amp, Laundry, main breaker, 480V
34
Bldg. 1, Main Facility
B21
Breaker #2, 300-Amp, Laundry, 500KVA transformer, 480V
35
Bldg. 1, Main Facility, Panel H1F
B21
Main breaker, Laundry panels, 400-Amp, 120/208V
36
Bldg. 1, Main Facility, Panel H1F
B21
Main breaker, 2nd Floor A/C Unit, 400-Amp
37
Bldg. 1, Switchboard DPBW
n/a
Main breaker, 1200-Amp, Panel H5WD, Room 512, 120/208V
38
Bldg. 1, Switchboard DPBW
n/a
Main breaker, 600-Amp, Panel H5ED, Room 568, 120/208V
39
Bldg. 1, Switchboard DPBW
n/a
Main breaker, 500-Amp, 120/208V
40
Bldg. 1, Switchboard DPBW, Panel HQ
n/a
Breaker #1, 300-Amp, Panel location by Bldg. 7
41
Bldg. 1, Switchboard DPBW, Panel HQ
n/a
Main breaker, 500-Amp, 120/208V, Panel location by Bldg. 7
42
Bldg. 1, Switchboard DPBW, Panel QL
n/a
Main breaker, 300-Amp, (NOT IN SERVICE), 480V, Panel location by Bldg. 7
43
Bldg. 8 (transformer is a dry type, no need to test but must be cleaned out when breakers are being testing), 480V Square D Panel
n/a
600-Amp Main Breaker
44
Bldg. 8
n/a
400-Amp Breaker
45
Bldg. 8
n/a
300-Amp Breaker
46
Bldg. 8
n/a
208/120V, 800-Amp Breaker
47
Bldg. 8
n/a
208/120V, 300-Amp Breaker
48
Bldg. 17 (transformer is a dry type, no need to test but must be cleaned out when breakers are being tested), 480V Square D Panel
n/a
600-Amp Main Breaker
49
Bldg. 17
n/a
400-Amp Breaker
50
Bldg. 17
n/a
300-Amp Breaker
51
Bldg. 17
n/a
208/120V, 800-Amp Breaker
52
Bldg. 17
n/a
208/120V, 300-Amp Breaker
53
Bldg. 17
n/a
Outside Square D molded case breaker, 300-AMP Breaker
54
Bldg. 17
n/a
Outside MDP Panel Square D, 800-AMP Breaker
55
Bldg. 17
n/a
Outside Square D l-Line, 800-AMP Breaker
56
Bldg. 18, Domiciliary (transformer is a dry type, no need to test but must be cleaned out when breakers are being testing), 480V Square D Panel
n/a
600-AMP Main Breaker
57
Bldg. 18, Domiciliary
n/a
400-Amp Breaker
58
Bldg. 18, Domiciliary
n/a
300-AMP Breaker
59
Bldg. 18, Domiciliary
n/a
208/120V 800-AMP Breaker
60
Bldg. 18, Domiciliary
n/a
208/120V 300-Amp Breaker
61
Bldg. 18, Domiciliary
n/a
Main GE Breaker, 800- AMP
62
Bldg. 18, Domiciliary
n/a
Main transformer breaker T-1, 450-AMP
63
Bldg. 18, Domiciliary
n/a
208/120V Panel Main breaker, 800-AMP
64
Bldg. 18, Domiciliary
n/a
MDP Panel Outside, 400-AMP breaker
65
Bldg. 18, Domiciliary
n/a
MDP Panel Outside, AV-Line, 800-AMP Breaker
66
Bldg. 18, Domiciliary
n/a
Main breaker #6, XFRM, 4 protective relays, 12.5kv volts
67
Bldg. 20 (transformer is a dry type, no need to test but must be cleaned out when breakers are being tested), 480V Square D Panel
n/a
600-Amp Main Breaker
68
Bldg. 20
n/a
400-AMP Breaker
69
Bldg. 20
n/a
300-AMP Breaker
70
Bldg. 20
n/a
208/120V, 800-AMP Breaker
71
Bldg. 20
n/a
208/120V, 300-Amp Breaker
72
Bldg. 21(transformer is a dry type, no need to test but must be cleaned out when breakers are being testing), 480V Square D Panel
n/a
600-Amp Main Breaker
73
Bldg. 21
n/a
400-AMP Breaker
74
Bldg. 21
n/a
300-AMP Breaker
75
Bldg. 21
n/a
208/120V, 800-AMP Breaker
76
Bldg. 21
n/a
208/120V, 300-AMP Breaker
77
Bldg. 21
n/a
Main Square D Outside LC3600, 600-AMP
78
Bldg. 21
n/a
Transformer Square D LA400, 400-AMP
79
Bldg. 21
n/a
Southwest Building Square D Outside LA300, 300-AMP
80
Bldg. 22, Main Panel SES-DPN
n/a
RK 2000-Amp
81
Bldg. 22
n/a
RJ 1200-Amp
82
Bldg. 22
n/a
PK 800-Amp
83
Bldg. 22
n/a
PK 800-Amp (IS OFF)
84
Bldg. 22, Panel DPE Generator Panel, 480V
n/a
PK 1200-Amp
85
Bldg. 22
n/a
LJ 600-Amp
86
Bldg. 22
n/a
LJ 400-Amp (IS OFF)
87
Bldg. 22
n/a
PK 800-Amp
88
Bldg. 22
n/a
Panel DPEQ Main Breaker PG 800-AMP
89
Bldg. 22
n/a
LH 400-AMP BREAKER (IS OFF)
90
Bldg. 22
n/a
Panel DPLS Main Breaker RLH 400-AMP
91
Bldg. 25
n/a
C1M Square D 400-AMP Main Breaker

Transformers to be analyzed and dielectric strength:

1
Bldg. 2, Boiler Plant
n/a
Westinghouse 2000kva
2
Bldg. 2, Boiler Plant
n/a
Square D 1000 kva
3
Bldg. 2, Boiler Plant
n/a
Vantran 225kva
4
Bldg. 1, Generator
n/a
Square D 1500kva
5
Bldg. 1, Generator
n/a
Vantran 300kva
6
Bldg. 7
n/a
Vantran 150kva
7
Bldg. 7
n/a
Square D 150kva
8
Bldg. 7
n/a
Vantran 75kva
9
Bldg. 18, Domiciliary
n/a
Square D 750kva