Attachment A-List of Equipment.docx
DOCX document 29 KB Posted
- Attached to
- J061--Electrical Power Distribution System & Dissolved Gas Analysis Services Federal contract opportunity
- Solicitation number
- 36C25726Q0116
About this file
This document is an Attachment A listing electrical equipment for calibration and testing across multiple buildings within a VA facility. The comprehensive inventory includes 91 electrical breakers and switchboards located in Buildings 1, 2, 8, 15, 17, 18, 20, 21, 22, and 25, with specifications detailing amperage, voltage (primarily 480V), and specific locations such as main switchboards, generator switchboards, and various panels. Additionally, the document lists 9 transformers from manufacturers like Westinghouse, Square D, and Vantran, ranging from 75 kva to 2000 kva, located in buildings such as the Boiler Plant, Generator room, and Domiciliary.
The related federal contract opportunity is a Department of Veterans Affairs solicitation (36C25726Q0116) titled "J061--Electrical Power Distribution System & Dissolved Gas Analysis Services" under Veterans Health Administration Veterans Integrated Service Network 17, which appears directly aligned with the detailed electrical equipment inventory provided in the attachment.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S02 36C25726Q0116.docx | DOCX document | |
| 36C25726Q0116_1.docx | DOCX document | |
| Service Contract Act WD_2015-5269_rv29_7-8-2025.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT A
List of electrical equipment for calibration and testing:
| Building # |
| Room # |
| Description |
| 1 |
| Bldg. 15, Main Switchboard Panel |
| n/a |
| Main breaker #1, 4 protective relays, 12.5kv volts |
| 2 |
| Bldg. 15, Main Switchboard Panel |
| n/a |
| Main breaker #2, XFRM, 4 protective relays, 12.5kv volts |
| 3 |
| Bldg. 15, Main Switchboard Panel |
| n/a |
| Main breaker #3, XFRM, 4 protective relays, 12.5kv volts |
| 4 |
| Bldg. 2 |
| n/a |
| Main breaker #4, XFRM, 4 protective relays, 12.5kv volts |
| 5 |
| Bldg. 2 |
| n/a |
| Main breaker #5, XFRM, 4 protective relays, 12.5kv volts |
| 6 |
| Bldg. 2 |
| n/a |
| MCCA Main breaker, 400AMP GE breaker |
| 7 |
| Switchboard M Main |
| n/a |
| Main breaker, RL 2000- Amp, 480V |
| 8 |
| Switchboard M Main |
| n/a |
| Breaker #2, RL 800- Amp, normal power central, 480V |
| 9 |
| Switchboard M Main |
| n/a |
| Breaker #3, RL 800-Amp, transformer D.D.T. #1-85, Electrical Equipment Room #2, 480V |
| 10 |
| Switchboard M Main |
| n/a |
| Breaker #4, RL 800-Amp, transformer D.D.T. #3-85, Electrical Equipment Room #3, 480V |
| 11 |
| Switchboard M Main |
| n/a |
| Breaker #5, RL 800-Amp, 2nd Floor Lab A/C, 480V |
| 12 |
| Switchboard M Main |
| B21 |
| Breaker #6, RL 800-Amp, Laundry Equipment and ITS, 480V |
| 13 |
| Switchboard M Main |
| B13 |
| Breaker #7, RL 800-Amp, 4 banks elev., 480V |
| 14 |
| Switchboard M Main |
| B12 |
| Breaker #8, RL 800-Amp, Life Safety Branch, 480V |
| 15 |
| Switchboard M Main |
| B12 |
| Breaker #9, RL 800-Amp, Critical Branch, 480V |
| 16 |
| Switchboard M Main |
| B12 |
| Breaker #10, RL 800-Amp, Equipment Branch, 480V |
| 17 |
| Switchboard M Main, Bldg. 15 |
| n/a |
| Breaker #11, RL 800-Amp, Panel HNSG switchgear gen, 480V |
| 18 |
| Switchboard M Main |
| n/a |
| Fire pump switchgear, RHX 1600-Amp, 480V |
| 19 |
| Switchboard M Main |
| n/a |
| Solar Panels, switchgear, RL 800-Amp, 480V |
| 20 |
| Switchboard M Main |
| n/a |
| Spare switchgear, RL 800-Amp, 480V |
| 21 |
| Switchboard M Main |
| n/a |
| Spare switchgear, RL 800-Amp, 480V |
| 22 |
| Switchboard M Main |
| n/a |
| Spare breaker, RL 2000- Amp, 480V |
| 23 |
| Switchgear Board X-R Main |
| n/a |
| Breaker #1, RL 2000-Amp, Main breaker, 480V |
| 24 |
| Switchgear Board X-R Main |
| n/a |
| Breaker #2, RL 800-Amp, X-ray breaker, 480V |
| 25 |
| Switchgear Board X-R Main |
| n/a |
| Breaker #3, RL 800-Amp, Dental, 48V |
| 26 |
| Switchgear Board X-R Main |
| n/a |
| Breaker #4, RL 800-Amp, 2nd Floor X-ray panel, 480V |
| 27 |
| Switchgear Board X-R Main |
| n/a |
| Breaker #5, RL 800-Amp, normal power transformer for 3 West, 480V |
| 28 |
| Generator Switchboard |
| n/a |
| Breaker #1, LA-1600-Amp, main breaker (bolt in), 480V |
| 29 |
| Generator Switchboard |
| n/a |
| Breaker #3, 400-Amp, ATS#2, Critical, 480V |
| 30 |
| Generator Switchboard |
| n/a |
| Breaker #4, 400-Amp, ATS#3, equipment, 480V |
| 31 |
| Generator Switchboard |
| n/a |
| Breaker #7, 400-Amp, ATS#6, elevators, 480V |
| 32 |
| Generator Switchboard |
| n/a |
| Breaker #9, 350-Amp, fire pump, 480V |
| 33 |
| Bldg. 1, Main Facility |
| B21 |
| Breaker #1, 600-Amp, Laundry, main breaker, 480V |
| 34 |
| Bldg. 1, Main Facility |
| B21 |
| Breaker #2, 300-Amp, Laundry, 500KVA transformer, 480V |
| 35 |
| Bldg. 1, Main Facility, Panel H1F |
| B21 |
| Main breaker, Laundry panels, 400-Amp, 120/208V |
| 36 |
| Bldg. 1, Main Facility, Panel H1F |
| B21 |
| Main breaker, 2nd Floor A/C Unit, 400-Amp |
| 37 |
| Bldg. 1, Switchboard DPBW |
| n/a |
| Main breaker, 1200-Amp, Panel H5WD, Room 512, 120/208V |
| 38 |
| Bldg. 1, Switchboard DPBW |
| n/a |
| Main breaker, 600-Amp, Panel H5ED, Room 568, 120/208V |
| 39 |
| Bldg. 1, Switchboard DPBW |
| n/a |
| Main breaker, 500-Amp, 120/208V |
| 40 |
| Bldg. 1, Switchboard DPBW, Panel HQ |
| n/a |
| Breaker #1, 300-Amp, Panel location by Bldg. 7 |
| 41 |
| Bldg. 1, Switchboard DPBW, Panel HQ |
| n/a |
| Main breaker, 500-Amp, 120/208V, Panel location by Bldg. 7 |
| 42 |
| Bldg. 1, Switchboard DPBW, Panel QL |
| n/a |
| Main breaker, 300-Amp, (NOT IN SERVICE), 480V, Panel location by Bldg. 7 |
| 43 |
| Bldg. 8 (transformer is a dry type, no need to test but must be cleaned out when breakers are being testing), 480V Square D Panel |
| n/a |
| 600-Amp Main Breaker |
| 44 |
| Bldg. 8 |
| n/a |
| 400-Amp Breaker |
| 45 |
| Bldg. 8 |
| n/a |
| 300-Amp Breaker |
| 46 |
| Bldg. 8 |
| n/a |
| 208/120V, 800-Amp Breaker |
| 47 |
| Bldg. 8 |
| n/a |
| 208/120V, 300-Amp Breaker |
| 48 |
| Bldg. 17 (transformer is a dry type, no need to test but must be cleaned out when breakers are being tested), 480V Square D Panel |
| n/a |
| 600-Amp Main Breaker |
| 49 |
| Bldg. 17 |
| n/a |
| 400-Amp Breaker |
| 50 |
| Bldg. 17 |
| n/a |
| 300-Amp Breaker |
| 51 |
| Bldg. 17 |
| n/a |
| 208/120V, 800-Amp Breaker |
| 52 |
| Bldg. 17 |
| n/a |
| 208/120V, 300-Amp Breaker |
| 53 |
| Bldg. 17 |
| n/a |
| Outside Square D molded case breaker, 300-AMP Breaker |
| 54 |
| Bldg. 17 |
| n/a |
| Outside MDP Panel Square D, 800-AMP Breaker |
| 55 |
| Bldg. 17 |
| n/a |
| Outside Square D l-Line, 800-AMP Breaker |
| 56 |
| Bldg. 18, Domiciliary (transformer is a dry type, no need to test but must be cleaned out when breakers are being testing), 480V Square D Panel |
| n/a |
| 600-AMP Main Breaker |
| 57 |
| Bldg. 18, Domiciliary |
| n/a |
| 400-Amp Breaker |
| 58 |
| Bldg. 18, Domiciliary |
| n/a |
| 300-AMP Breaker |
| 59 |
| Bldg. 18, Domiciliary |
| n/a |
| 208/120V 800-AMP Breaker |
| 60 |
| Bldg. 18, Domiciliary |
| n/a |
| 208/120V 300-Amp Breaker |
| 61 |
| Bldg. 18, Domiciliary |
| n/a |
| Main GE Breaker, 800- AMP |
| 62 |
| Bldg. 18, Domiciliary |
| n/a |
| Main transformer breaker T-1, 450-AMP |
| 63 |
| Bldg. 18, Domiciliary |
| n/a |
| 208/120V Panel Main breaker, 800-AMP |
| 64 |
| Bldg. 18, Domiciliary |
| n/a |
| MDP Panel Outside, 400-AMP breaker |
| 65 |
| Bldg. 18, Domiciliary |
| n/a |
| MDP Panel Outside, AV-Line, 800-AMP Breaker |
| 66 |
| Bldg. 18, Domiciliary |
| n/a |
| Main breaker #6, XFRM, 4 protective relays, 12.5kv volts |
| 67 |
| Bldg. 20 (transformer is a dry type, no need to test but must be cleaned out when breakers are being tested), 480V Square D Panel |
| n/a |
| 600-Amp Main Breaker |
| 68 |
| Bldg. 20 |
| n/a |
| 400-AMP Breaker |
| 69 |
| Bldg. 20 |
| n/a |
| 300-AMP Breaker |
| 70 |
| Bldg. 20 |
| n/a |
| 208/120V, 800-AMP Breaker |
| 71 |
| Bldg. 20 |
| n/a |
| 208/120V, 300-Amp Breaker |
| 72 |
| Bldg. 21(transformer is a dry type, no need to test but must be cleaned out when breakers are being testing), 480V Square D Panel |
| n/a |
| 600-Amp Main Breaker |
| 73 |
| Bldg. 21 |
| n/a |
| 400-AMP Breaker |
| 74 |
| Bldg. 21 |
| n/a |
| 300-AMP Breaker |
| 75 |
| Bldg. 21 |
| n/a |
| 208/120V, 800-AMP Breaker |
| 76 |
| Bldg. 21 |
| n/a |
| 208/120V, 300-AMP Breaker |
| 77 |
| Bldg. 21 |
| n/a |
| Main Square D Outside LC3600, 600-AMP |
| 78 |
| Bldg. 21 |
| n/a |
| Transformer Square D LA400, 400-AMP |
| 79 |
| Bldg. 21 |
| n/a |
| Southwest Building Square D Outside LA300, 300-AMP |
| 80 |
| Bldg. 22, Main Panel SES-DPN |
| n/a |
| RK 2000-Amp |
| 81 |
| Bldg. 22 |
| n/a |
| RJ 1200-Amp |
| 82 |
| Bldg. 22 |
| n/a |
| PK 800-Amp |
| 83 |
| Bldg. 22 |
| n/a |
| PK 800-Amp (IS OFF) |
| 84 |
| Bldg. 22, Panel DPE Generator Panel, 480V |
| n/a |
| PK 1200-Amp |
| 85 |
| Bldg. 22 |
| n/a |
| LJ 600-Amp |
| 86 |
| Bldg. 22 |
| n/a |
| LJ 400-Amp (IS OFF) |
| 87 |
| Bldg. 22 |
| n/a |
| PK 800-Amp |
| 88 |
| Bldg. 22 |
| n/a |
| Panel DPEQ Main Breaker PG 800-AMP |
| 89 |
| Bldg. 22 |
| n/a |
| LH 400-AMP BREAKER (IS OFF) |
| 90 |
| Bldg. 22 |
| n/a |
| Panel DPLS Main Breaker RLH 400-AMP |
| 91 |
| Bldg. 25 |
| n/a |
| C1M Square D 400-AMP Main Breaker |
Transformers to be analyzed and dielectric strength:
| 1 |
| Bldg. 2, Boiler Plant |
| n/a |
| Westinghouse 2000kva |
| 2 |
| Bldg. 2, Boiler Plant |
| n/a |
| Square D 1000 kva |
| 3 |
| Bldg. 2, Boiler Plant |
| n/a |
| Vantran 225kva |
| 4 |
| Bldg. 1, Generator |
| n/a |
| Square D 1500kva |
| 5 |
| Bldg. 1, Generator |
| n/a |
| Vantran 300kva |
| 6 |
| Bldg. 7 |
| n/a |
| Vantran 150kva |
| 7 |
| Bldg. 7 |
| n/a |
| Square D 150kva |
| 8 |
| Bldg. 7 |
| n/a |
| Vantran 75kva |
| 9 |
| Bldg. 18, Domiciliary |
| n/a |
| Square D 750kva |
File details come from the government source that posted it. Updated .