This document is a set of construction drawings for a patient restroom renovation project at the Salem VA Medical Center in Salem, Virginia. The project, identified as Contract No. 36C24625C0031 and Project No. 658-24-109, involves the renovation of patient restrooms across basement, first, second, and third floors of Building 143.
The scope encompasses demolition and replacement of plumbing fixtures, electrical systems, architectural finishes, and related building components in multiple restroom locations. Key project requirements include: coordination with VA Infection Control Risk Assessment (ICRA) protocols; phased work limiting demolition to no more than two restrooms per floor before replacements are installed; temporary construction barriers and dust control measures; protection of occupied hospital areas; and traffic control to maintain facility access. The contractor must schedule work at least two weeks in advance and obtain approval from the Salem VA Medical Center Contracting Officer's Representative. Plumbing systems require thermostatic mixing valves capped at 110°F maximum; all new fixtures must comply with ADA accessibility standards. Electrical work includes new GFCI-protected receptacles, occupancy sensors in restrooms, and updated lighting systems. Interior finishes specify ceramic tile wall and floor applications, cove-shaped aluminum profiles at wall-floor transitions, and specific paint and accessory schedules. The drawings include comprehensive details for water closets, lavatories, electrical layouts, lighting plans, reflected ceiling plans, and finish specifications across all affected floors, with construction work time zones and phasing coordination requirements clearly delineated.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROANOKE BLVD.
PATRIOT BLVD.
PATR
IO
T C
IR
C
LE
PATRIOT CIRCLE
ARM
Y BLVD.
W. RIVERSIDE DR.
TW
EL
VE
O
' C
LO
CK
K
NO
B
RD
G O
O D
W
IN
AVE.
ACADEM
Y ST.
TH
O
M
PS
O N
M
EM
O
R
IA
L D
R
E. MAIN ST.
E. MAIN ST.
MELROSE AVE.
4TH ST.
ROANOKE
BLVD.
N
. ELEC
TR
IC
R D
N . E
LE
C
TR
IC
R D
C O
LO
R
AD
O
S T.
LEE HWY.
PE
TE
R S
C R
EE
K
R D
ROANOKE BLVD.
8TH ST.
SALEM TURNPIKE NW
SHENANDOAH AVE NW
SALEM
VAMC
PROJECT SITE
BUILDING 143
COVE RD.
HERSHBERGER RD. NW
LA
FA
YE
TT
E
BL
VD
N
W
CHAPMAN AVE SW.
CO
VE
R D.
BUILDING CODE SUMMARY
APPLICABLE CODES AND STANDARDS:
2022 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS
2025 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
2023 NFPA 70 NATIONAL ELECTRICAL CODE
2025 NFPA 72 NATIONAL FIRE ALARM CODE
2024 NFPA 101 LIFE SAFETY CODE
2015 ABAAS ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
2022 PG 18-13 VA BARRIER FREE DESIGN STANDARD, (REV..NOV. 1)
2021 PG 18-10 VA DESIGN CRITERIA, FIRE PROTECTION, (8TH ED. JUNE 1)
2024 IBC INTERNATIONAL BUILDING CODE
2024 IPC INTERNATIONAL PLUMBING CODE
2024 IMC INTERNATIONAL MECHANICAL CODE
OCCUPANCY CLASSIFICATION: HEALTH CARE
EXISTING BUILDING FLOOR AREAS:
BASEMENT 115,626 GSF (EXISTING)
1ST FLOOR 79,225 GSF (EXISTING)
2ND FLOOR 40,380 GSF (EXISTING)
3RD FLOOR 36,975 GSF (EXISITNG)
SUBDIVISION OF BUILDING SPACE: (NFPA SECTION 18.3.7)
ALLOWABLE SMOKE COMPARTMENT AREA IS UNCHANGED
BUILDING FIRE AREA:
OCCUPANCY LOAD: (NFPA 101 TABLE 7.3.1.2)
UNCHANGED
MEANS OF EGRESS: (NFPA 101 SECTION 7.1)
UNCHANGED
EXIT WIDTH CAPACITY: (NFPA 101) TABLE 7.3.3.1)
DOOR CAPACITY UNCHANGED
FIRE ALARM SYSTEM: (NFPA 101 SECTION 9.7.2)
EXISTING ALARM SYSTEM TO REMAIN UNCHAGED
FIRE SPRINKLER SYSTEM: (NFPA 101 SECTION 9.7)
EXISTING AUTOMATIC SPRINKLER SYSTEM TO REMAIN UNCHANGED
PORTABLE FIRE EXTINGUISHERS: (NFPA 10)
CABINETS MUST NOT PLACE EXTINGUISHER HANDLES MORE THAN
48" ABOVE FINISHED FLOOR. FIRE EXTINGUISHERS AND CABINETS
SHALL BE LOCATED AS REQUIRED BY NFPA 10, SEE CURRENT SHEET
AL100 FOR LOCATIONS.
INTERIOR FINISH: (NFPA 101 SECTION 18.3.3)
INTERIOR FINISH SHALL BE IN ACCORDANCE WITH NFPA 101
SECTION 10.2, AND CONTENTS AND FURNISHINGS SHALL BE IN
ACCORDANCE WITH PER NFPA 101 SECTION 10.3
CONSTRUCTION TYPE: (NFPA 220 TABLE 4.1.1)
TYPE II (000)
FULLY SPRINKLERED
5 STORY WITH BASEMENT
EXISTING HEALTH CARE (NFPA 101 CHAPTER 19)
THE HEALTH CARE FACILITIES REGULATED BY THIS CHAPTER SHALL BE THOSE
THAT PROVIDE SLEEPING ACCOMODATIONS FOR THEIR OCCUPANTS AND ARE
OCCUPIED BY PERSONS WHO ARE MOSTLY INCAPABLE OF SELF-PRESERVATION
BECAUSE OF AGE, PHYSICAL OR MENTAL DISABILITY, OR BECAUSE OF SECURITY
MEASURES NOT UNDER THE OCCUPANTS' CONTROL.
UNCHANGED
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:5
AM
GI001
COVER SHEET
FEBRUARY 2026 JME RJF
VICINITY MAP
RENOVATE PATIENT RESTROOMS
VA MEDICAL CENTER
SALEM, VA.
DEPARTMENT OF VETERAN AFFAIRS
CONTRACT NO. 36C24625C0031
PROJECT NO. 658-24-109
FACILITY MAP
DRAWING INDEX
SHEET
NUMBER SHEET NAME
SEQUENC
E SHEET #
GENERAL
GI001 COVER SHEET 1
GI002 ABBREVIATIONS, LEGEND, NOTES, AND SYMBOLS 2
STRUCTURAL
SE100 STRUCTURAL FLOOR PLANS AND GENERAL NOTES 3
ARCHITECTURAL
AE100 BASEMENT FLOOR PLAN - OVERALL 4
AE101 1ST FLOOR PLAN - OVERALL 5
AE102 2ND FLOOR PLAN - OVERALL 6
AE103 3RD FLOOR PLAN - OVERALL 7
AD400 BASEMENT FLOOR PLANS - ENLARGED DEMOLITION 8
AD401 1ST FLOOR PLANS - ENLARGED DEMOLITION 9
AD402 2ND & 3RD FLOOR PLANS - ENLARGED DEMOLITION 10
AE400 BASEMENT FLOOR PLANS - ENLARGED 11
AE401 1ST FLOOR PLANS - ENLARGED 12
AE402 2ND & 3RD FLOOR PLANS - ENLARGED 13
AE410 BASEMENT REFLECTED CEILING PLANS - ENLARGED 14
AE411 1ST FLOOR REFLECTED CEILING PLANS - ENLARGED 15
AE412 2ND & 3RD FLOOR REFLECTED CEILING PLANS - ENLARGED 16
AE420 BASEMENT FLOOR FINISH PLANS & INTERIOR ELEVATIONS 17
AE421A 1ST FLOOR FINISH PLANS & INTERIOR ELEVATIONS 18
AE421B 1ST FLOOR FINISH PLANS & INTERIOR ELEVATIONS 19
AE422 2ND AND 3RD FLOOR FINISH PLANS & INTERIOR ELEVATIONS 20
AE423 2ND AND 3RD FLOOR FINISH PLANS & INTERIOR ELEVATIONS 21
AE501 PARTITION TYPES 22
AE502 DETAILS 23
AE601 DOOR SCHEDULES AND ELEVATIONS 24
AE602 ROOM FINISH, DOOR AND SCHEDULE FOR INTERIOR FINISHES, AND INTERIOR DETAILS 25
AE603 TOILET ACCESSORIES HEIGHTS, SCHEDULES AND MISCELLANEOUS DETAILS 26
PLUMBING
PI001 PLUMBING GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS 27
PD400 BASEMENT WASTE AND VENT PIPING DEMO ENLARGED PLANS 28
PD401 1ST FLOOR WASTE AND VENT PIPING DEMO ENLARGED PLANS 29
PD402 2ND FLOOR WASTE AND VENT PIPING DEMO ENLARGED PLANS 30
PD403 3RD FLOOR WASTE AND VENT PIPING DEMO ENLARGED PLANS 31
PD410 BASEMENT DOMESTIC WATER PIPING DEMO ENLARGED PLANS 32
PD411 1ST FLOOR DOMESTIC WATER PIPING DEMO ENLARGED PLANS 33
PD412 2ND FLOOR DOMESTIC WATER PIPING DEMO ENLARGED PLANS 34
PD413 3RD FLOOR DOMESTIC WATER PIPING DEMO ENLARGED PLANS 35
PL400 BASEMENT WASTE AND VENT PIPING ENLARGED PLANS 36
PL401 1ST FLOOR WASTE AND VENT PIPING ENLARGED PLANS 37
PL402 2ND FLOOR WASTE AND VENT PIPING ENLARGED PLANS 38
PL403 3RD FLOOR WASTE AND VENT PIPING ENLARGED PLANS 39
PP400 BASEMENT DOMESTIC WATER PIPING ENLARGED PLANS 40
PP401 1ST FLOOR DOMESTIC WATER PIPING ENLARGED PLANS 41
PP402 2ND FLOOR DOMESTIC WATER PIPING ENLARGED PLANS 42
PP403 3RD FLOOR DOMESTIC WATER PIPING ENLARGED PLANS 43
PI501 PLUMBING DETAILS 44
PI601 PLUMBING SCHEDULES 45
ELECTRICAL
EI001 ELECTRICAL GENERAL NOTES, SYMBOLS, & ABBREVIATIONS 46
ED400 BASEMENT POWER DEMOLITION ENLARGED PLANS 47
ED401 1ST FLOOR POWER DEMOLITION ENLARGED PLANS 48
ED402 2ND & 3RD FLOOR POWER DEMOLITION ENLARGED PLANS 49
EL400 BASEMENT FLOOR ELECTRICAL LIGHTING PLAN 50
EL401 1ST FLOOR ELECTRICAL LIGHTING PLAN 51
EL402 2ND & 3RD FLOOR ELECTRICAL LIGHTING PLAN 52
EP400 BASEMENT POWER ENLARGED PLANS 53
EP401 1ST FLOOR POWER ENLARGED PLANS 54
EP402 2ND & 3RD FLOOR POWER ENLARGED PLANS 55
EL601 LIGHTING SCHEDULE 56
NORTH
N
NORTH
N
PROJECT SITE
BUILDING 143
REVISIONS DATE
02.26.2026
CONTRACTOR SHALL REFER TO CONSTRUCTION TIME ZONES AS DELINEATED IN THE DRAWINGS
SET, AND CONFIRM ALL TIME ZONES WITH COR AT LEAST 3 WEEKS PRIOR TO START OF WORK.
TRAFFIC CONTROL SHALL BE THE CONTRACTOR'S RESPONSIBILITY, INCLUDING: TRAFFIC
CONTROL PLANS, FLAGGERS, SIGNAGE, BARRICADES, LIGHTING, PLATING, AND ANY ADDITIONAL
RESOURCES AS REQUIRED ENSURING FACILITY ACCESS AND FACILITY FUNCTION IS NOT
DISRUPTED.
WORK ZONES WILL NEED TO BE COORDINATED WITH VA TO MINIMIZE DISRUPTIONS TO THE
CAMPUS. IN ADDITION TO SPECIFICATION REQUIREMENTS, NOISE CONTROL PLANS SHALL BE
REQUIRED TO ADDRESS SOURCE CONTROL AND PATH CONTROL TO ENSURE PATIENTS,
EMPLOYEES, AND FACILITY FUNCTIONS ARE NOT DISTURBED.
PHASING SHALL BE AS FOLLOWS:
A. NO MORE THAN TWO RESTROOMS PER FLOOR SHALL BE REMOVED
CONSECUTIVELY BEFORE TWO RESTROOMS HAVE BEEN REPLACED.
B. ALL WORK SHALL BE SCHEDULED AT LEAST TWO WEEKS PRIOR TO START DATE.
APPROVAL SHALL BE OBTAINED FROM THE SALEM VA MEDICAL CENTER
CONTRACTING OFFICER REPRESENTATIVE TO ENSURE PROPER COORDINATION WITH
HEALTHCARE OPERATIONS.
C. ALL ASSOCIATED WORK SHALL BE COMPLETED BEFORE MOVING TO A NEW WORK
AREA (I.E. NEW TOILET ROOM PLUMBING FIXTURES AND TOILET SPECIALTIES IN
PLACE AND OPERATIONAL, ALL FLOOR, CEILING, AND WALL FINISHES INSTALLED/ OR
REPAIRED, TEMPORARY DUST BARRIER ITEMS REMOVED, AREA CLEANED TO EMS
READINESS FOR NEW PATIENT/USER PREPARATION).
PHASING NOTES:
1.
2.
3.
4.
THE CONTRACTOR SHALL USE THE FOLLOWING AS A GUIDE FOR ALL
INFECTION CONTROL RISK ASSESSMENT (ICRA) BARRIERS. TEMPORARY
INFECTION CONTROL BARRIERS SHALL BE CONSTRUCTED AS FOLLOWS
DEPENDING UPON LENGTH OF NEED:
A. 1 DAY MAXIMUM - FLAME-RETARDANT PLASTIC
TEMPORARY CONSTRUCTION BARRIERS TO BE USED SHALL BE
EXTENSION POLE KITS WITH FIRE RESISTANT FABRIC. BARRIERS ARE
TO EXTEND TO THE BOTTOM OF EXISTING CEILINGS. PROVIDE NON-
DAMAGING SEAL AT INTERSECTION WITH CEILING. PROVIDE PLASTIC
SHEET BARRIER SEAL BETWEEN TOP OF WALL AND STRUCTURE ABOVE.
TAPE ALL SEAMS AND PENETRATION OPENINGS TO PREVENT
CONTAMINATION FROM PASSING OVER THE TOP OR UNDERNEATH THE
WALL FROM CONSTRUCTION AREAS.
PRE-MANUFACTURED PVC BARRIERS MAY BE USED AS AN ALTERNATIVE
SYSTEM. TYPE II BARRIERS SHALL BE ANCHORED TO THE FLOORING
SURFACE (WHICH IS INTENDED TO REMAIN) BY TAPING BOTTOM STUD
TRACK TO FLOOR SURFACE OR BY OTHER METHODS WHICH WILL NOT
HARM FLOOR SURFACE.
TEMPORARY PARTITIONS SHALL NOT CONSTRICT WALKWAYS TO LESS
THAN 6'-0" CLEAR. ANY EXITS CHANGED OR BLOCKED SIGNAGE NEEDS
TO BE POSTED FOR THE MODIFICATIONS.
TEMPORARY CONSTRUCTION BARRIERS:
1.
2.
3.
4.
X
A101
View Name
SCALE: 1/8" = 1'-0"
A101
A101
View Name
SCALE: 1/8" = 1'-0"
A101
SIM
ROOM NAME
150 SF
XXX
A101
SYMBOLS LEGEND:
SECTIONS
ELEVATION HEIGHTS
EXTERIOR ELEVATIONS
INTERIOR ELEVATIONS
DRAWING TITLES
DETAIL OR ENLARGED PLAN
GRID LINES
ROOM TAG
KEYNOTE
NORTH ARROW
WINDOW TAG
DOOR TAG
WALL TYPE
REVISION NUMBER
REVISION CLOUD
SECTION NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
DRAWING TITLE
DRAWING SCALEDRAWING TITLE
DRAWING SCALE
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
ROOM NUMBER
GRAPHIC SCALE
X
EQUIPMENT TAG
PLAN
NORTH
N
TRUE
NORTH
N
1/8"=1'-0" 0 16'8'8' 4'
VIEW NAME
VIEW NAME
X
WINDOW TYPE AMOUNT
WINDOW TYPE
FLOOR
LEVEL A
A
CONSTRUCTION WORK TIME ZONE
GENERAL NOTES:
REFER AND ADHERE TO THE INFECTION PREVENTION MEASURE
REQUIREMENTS IN SPECIFICATION SECTION 01 00 00 GENERAL
REQUIREMENTS AND SPECIFICATION 01 35 26 SAFETY REQUIREMENTS.
PROTECT ALL FURNISHINGS AND EQUIPMENT DURING CONSTRUCTION
FROM DAMAGE AND CONSTRUCTION DEBRIS.
REFER TO SHEETS AE420, AE421, AND AE422 FOR INTERIOR ELEVATIONS.
ALL DIMENSION GIVEN TO FINISHED FACE OF GYPSUM BOARD, CENTER
LINE OF FIXTURES, AND EXISTING GRID LINES, UNLESS NOTED
OTHERWISE.
DRAWINGS SHALL NOT BE SCALED, ALL WORK SHALL BE LAID OUT BY
DIMENSIONS.
ALL DETAILS APPLY WHETHER OR NOT SPECIFICALLY REFERENCED.
ALL AREAS OF WORK SHALL BE CONSIDERED TO BE CONSTRUCTION
TIME ZONE 'A', UNLESS NOTED OTHERWISE ON DRAWINGS. REFER TO
CONSTRUCTION WORK TIME LEGEND BELOW.
THE AREAS OF WORK WILL BE OCCUPIED DURING CONSTRUCTION. THE
CONTRACTOR SHALL PROVIDE ALL SAFEGUARDS FOR PERSONNEL,
PATIENTS, AND EQUIPMENT WITHIN ROOM AREA WHERE CONSTRUCTION
IS BEING ACCOMPLISHED. THE CONTRACTOR SHALL NOTIFY THE COR
NO LATER THAN 2 WEEKS PRIOR TO CONSTRUCTION IN ANY GIVEN
ROOM FOR COORDINATION WITH STAFF PERSONNEL AND PATIENT
NEEDS.
.ALL SURFACES DAMAGED DURING DEMOLITION AND INSTALLATION
WORK SHALL BE PATCHED AND REPAIRED TO NEW CONDITION AND
PAINTED TO MATCH ADJACENT SURFACES.
CAULKING AND SEALANT SHALL MATCH COLOR ON ALL EXPOSED
SURFACES.
GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING DESIGN AND
CALCULATIONS FOR STRUCTURAL ENGINEERING COMPONENTS. SHEET
SE100 IS INCLUDED FOR GENERAL INFORMATION TO OUTLINE SCOPE OF
WORK AREAS FOR DESIGN-BUILD STRUCTURAL ENGINEERING BY
GENERAL CONTRACTOR.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
N/A NOT APPLICABLE
N NORTH
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OFD OVERFLOW DRAIN
OH OVERHEAD
OPNG OPENING
OPOI OWNER PROVIDED, OWNER INSTALLED
OPP OPPOSITE
ORIG ORIGINAL
OVHD OVERHEAD
PA PUBLIC ADDRESS
PCF POUNDS PER CUBIC FOOT
PLF POUNDS PER LINEAL FOOT
PFN PRE-FINISHED
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
POC POINT OF CURVE/CONTACT
POI POINT OF INTERSECTION
POT POINT OF TANGENT
PPL PEOPLE
PR PAIR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT CONC POST-TENSIONED CONCRETE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
RAD RADIUS
RB RUBBER BASE
RCP REINFORCED CONCRETE PIPE,
REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER TO, REFERENCE
REIN REINFORCE(D)(ING)
RECP RECEPTACLE
RCYL RECYCLE AREA
REFR REFRIGERATOR
RO ROUGH OPENING
ROW RIGHT OF WAY
S SOUTH
SAFB SOUND ATTENUATION FIRE BATTS
SAN SANITARY
SB SPLASH BLOCK
SC SOLID CORE
SCH SCHEDULE
SD STORM DRAIN
SECT SECTION
SEW SEWER
SHT SHEET
SIM SIMILAR
SPF SPRAY APPLIED POLYURETHANE FOAM
INSULATION
SPEC SPECIFICATION
SQ SQUARE
SS SERVICE SINK, STORM SEWER,
STAINLESS STEEL
STM STORM
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SWBD SWITCHBOARD
T&G TONGUE AND GROOVE
TCU THIN CLAD UNIT
TEL TELEPHONE
THK THICK(NESS)
THRU THROUGH
TJI TRUSJOIST INCORPORATED
T.O. TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL/TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
ABV ABOVE
ACI AMERICAN CONCRETE INSTITUTE
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLER UNIT
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AISI AMERICAN IRON & STEEL INSTITUTE
ALUM ALUMINUM
ALM ALARM
ALT ALTERNATE
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATING & AIR
CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING
AND MATERIALS
AWG AMERICAN WIRE GAGE
AWS AMERICAN WELDING SOCIETY
AWWA AMERICAN WATER WORKS
ASSOCIATION
BL BUILDING LINE
BLDG BUILDING
B.O. BOTTOM OF
BRK BRICK
BR BROCHURE RACK
BUR BUILT UP ROOFING
CAB CABINET
CF CUBIC FOOT
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CJ CONTROL JOINT
CKT CIRCUIT
CL CENTERLINE
CLOS CLOSET
CLG CEILING
CLR CLEAR(ANCE)
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CO CLEANOUT
COL COLUMN
CONC CONCRETE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR
CRS COURSE(S)
CTR CENTER
CNTR COUNTER
CU IN CUBIC INCH
CU YD CUBIC YARD
CW CLEAR WIDTH
D PENNY (NAILS, ETC.)
DEMO DEMOLITION
DET DETAIL
DIAM,Ø DIAMETER
DC DISPLAY CASE
DP DAMP PROOFING
DPR DAMPER
DR DOOR
DS DOWNSPOUT
DSP DRY STANDPIPE
DWG DRAWING
DWS DOMESTIC WATER SUPPLY
E EAST
EA EACH
ELEV ELEVATION
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
EMER EMERGENCY
EP ELECTRICAL PANEL
EPDM ETHYLENE-PROPYLENE-DIENE-
MONOMER
EF EXHAUST FAN
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FB FACE BRICK
FC FOOT-CANDLE
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
FFE FURNITURE, FIXTURES AND EQUIPMENT
FG FIXED GLASS
FIN FL FINISHED FLOOR
FIN FL EL FINISHED FLOOR ELEVATION
FIX FIXTURE
FL FLOOR
FH FIRE HYDRANT
FLUOR FLUORESCENT
FMS FACILITY MANAGEMENT SERVICES
FND FOUNDATION
FO FACE OF
FOC FACE OF CONCRETE / CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUDS
FT FOOT / FEET
FTG FOOTING
FURR FURRED(ING)
GA GAGE, GAUGE
GALV GALVANIZE(D)
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
GFI GROUND FAULT CIRCUIT INTERRUPTER
GL GLASS, GLAZING
GWB GYPSUM WALL BOARD
GRND GROUND
GRT GROUT
HAC HOUSEKEEPING AIDS CLOSET
HB HOSE BIB
HNDCP HANDICAP
HDW HARDWARE
HJT HEAD JOINT
HM HOLLOW METAL
HORZ HORIZONTAL
HP HORSE POWER / HIGH PRESSURE
HSKP HOUSEKEEPING
HT HEIGHT
HVAC HEATING, VENTILATION, AIR
CONDITIONING
HWS HOT WATER SUPPLY
ID INSIDE DIAMETER
IES ILLUMINATING ENGINEERING SOCIETY
IGU INSULATED GLASS UNIT
IN INCH (“)
INC INCORPORATED
INFO INFORMATION
INSUL INSULATION/INSULATE(D)(ING)
INT INTERIOR
INV INVERT
JT JOINT
K KIP (1,000 LB.)
LDR LADDER
LAM LAMINATE
LAV LAVATORY
LB POUND
LAG LAG SCREW
LG LENGTH / LONG
LTG LIGHTING
LVL LAMINATED VENEER LUMBER
LW CONC LIGHTWEIGHT CONCRETE
M METER(S)
MAX MAXIMUM
MECH MECHANIC(AL)
MED MEDIUM
MTL METAL
MFR MANUFACTURE(R)
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MM MILLIMETER
MO MASONRY OPENING
UC UNDERCUT
UG UNDERGROUND
UL UNDERWRITERS'
LABORATORIES, INC.
UNO ` UNLESS NOTED
OTHERWISE
V VOLT
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VENT VENTILATE
VERT VERTICAL
VIF VERIFY IN FIELD
VIT VITREOUS
VS VERSUS
VC VERTICAL CURVE
VOL VOLUME
VPT VERTICAL POINT OF
TANGENT
VPI VERTICAL POINT OF
INTERSECTION
VPC VERTICAL POINT OF
CURVATURE
W WEST / WIDTH / WIDE /
W/ WITH
WC WATER CLOSET
WD WOOD
WG WIRE GLASS
WH WATER HEATER
WDW WINDOW
W/O WITHOUT
WT WEIGHT
WTR WATER
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
XPAN CROSS PAN
XSECT CROSS SECTION
XSTR EXTRA STRONG
YD YARD
YR YEAR
ABBREVIATIONS
INFECTIOUS CONTROL MEASURES:
DURING CONSTRUCTION:
A. SEAL HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
B. COMPLETE ALL CRITICAL BARRIERS I.E. SHEET ROCK, PLYWOOD, PLASTIC, TO SEAL
CONSTRUCTION AREAS FROM NON-PROJECT AREAS; OR IMPLEMENT CONTROL
CUBE METHOD (CART WITH PLASTIC COVERING AND SEALED CONNECTION TO
WORK SITE WITH AIR SCRUBBER FOR VACUUMING PRIOR TO EXIT) BEFORE
CONSTRUCTION BEGINS.
UPON COMPLETION OF PROJECT:
A. REMOVE BARRIER MATERIAL CAREFULLY TO MINIMIZE SPREADING OF DIRT AND
DEBRIS ASSOCIATED WITH CONSTRUCTION.
B. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED
CONTAINERS.
C. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
D. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.
E. WET MOP AREA WITH DISINFECTANT.
1.
2.
CONSTRUCTION WORK TIMES:
WEEKDAYS: MONDAY THRU FRIDAY
(START 7:00 AM AND END 4:00PM)
TIME ZONES WORK DAYS AND WORK DURATION
WEEKENDS: SATURDAY AND/OR SUNDAY
(START 8:00AM AND END 3:00PM)
WEEKDAY NIGHTIME: MON. THRU FRI.
(START 6:00PM AND END 5:00AM)
A
B
C
SCOPE OF WORK:
THIS PROJECT ADDRESSES THE FOLLOWING ITEMS:
THE PURPOSE OF THIS PROJECT IS THE RENOVATION OF UP TO
EIGHTEEN (18) PATIENT RESTROOMS WITHIN BUILDING 143 AT THE
SALEM VA MEDICAL CENTER.
THE GOAL IS TO BRING ALL RENOVATED RESTROOMS INTO
COMPLIANCE WITH APPLICABLE VA AND ABAAS REQUIREMENTS.
IMPROVEMENTS WILL FOCUS ON ACCESSIBILITY, USER SAFETY,
INFECTION CONTROL, AND OVERALL COMFORT. MATERIAL AND
FIXTURE SELECTIONS WILL PRIORITIZE DURABILITY, EASE OF
CLEANING, AND LONG SERVICE LIFE.
OPERATIONAL CONTINUITY IS A CRITICAL CONSIDERATION, AS
BUILDING 143 IS AN ACTIVE HEALTHCARE FACILITY. CONSTRUCTION
PHASING WILL BE DESIGNED TO ENSURE THAT ADEQUATE RESTROOM
FACILITIES REMAIN AVAILABLE TO STAFF AND PATIENTS AT ALL TIMES.
BELOW IS THE LIST OF THE 18 TOILET ROOMS IN THE SCOPE OF WORK
FOR THIS PROJECT.
BASEMENT: BC-104, BC-105, BC-110, BC-118, AND BE-111
FIRST FLOOR: 1EF-122, 1EF-123, 1E-130, 1EF-131, 1EF-156,
1FG-117, AND 1FG-118
SECOND FLOOR: 2J-100, 2J-101, 2J-138A, AND 2H-134B
THIRD FLOOR: 3J-100 AND 3J-101
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:5
AM
GI002
ABBREVIATIONS, LEGEND, NOTES,
AND SYMBOLS
FEBRUARY 2026 JME RJF
2REVISIONS DATE
D N
K L
6 6
6.7 6.7
OFFICE
1EF-118
RESIDENT OFFICE
1EF-119
MULTI PURPOSE
1EF-119A
OFFICE
1EF-120
OFFICE
1EF-120A
59 SF
TOILET
1EF-122
HOUSE KEEPING
1EF-121
58 SF
TOILET
1EF-123
1E F-
1E F-
1E F-
VI
F
5'
3/
8"
VIF
4' - 1 1/2"
GENERAL NOTES:
ABANDONED DUMBWAITER FLOOR INFILL:
PROVIDE A PERMANENT FLOOR INFILL AT THE ABANDONED
DUMBWAITER OPENING TO CREATE A CONTINUOUS FLOOR
ASSEMBLY FLUSH WITH ADJACENT CONSTRUCTION. THE
INFILL SYSTEM (INCLUDING SUPPLEMENTAL FRAMING,
COMPOSITE METAL DECK, CONCRETE FILL, REINFORCEMENT,
CONNECTIONS, AND ANY TEMPORARY SHORING) SHALL BE
DELEGATED TO THE CONTRACTOR WHICH SHALL BE
DESIGNED AND SEALED BY A LICENSED STRUCTURAL
PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR.
DESIGN SHALL COMPLY WITH THE GOVERNING DESIGN
LOADS AND CRITERIA. PROVIDE CONTINUITY OF REQUIRED
FIRE-RESISTANCE RATING AND FIRE/SMOKE SEALING AT THE
INFILL AND PERIMETER. A/E SHALL REVIEW IS FOR
CONFORMANCE WITH DESIGN INTENT ONLY.
THE ENGINEER IS TO REVIEW DEPRESSED SLABS THOSE
SHOWERS THAT ARE TO BE MADE LEVEL FOR THE TYPE OF
LEVELING CEMENT TO BE USED AND REINFORCEMENT. AS
WELL AS SPECIFICATION 01 35 26 SAFETY REQUIREMENTS.
REFER AND ADHERE TO THE INFECTION PREVENTION
MEASURE REQUIREMENTS IN SPECIFICATION SECTION 01 00
00 GENERAL REQUIREMENTS.
ALL DIMENSION GIVEN TO FINISHED FACE OF GYPSUM
BOARD, CENTER LINE OF FIXTURES, AND EXISTING GRID
LINES, UNLESS NOTED OTHERWISE.
DRAWINGS SHALL NOT BE SCALED, ALL WORK SHALL BE LAID
OUT BY DIMENSIONS.
ALL AREAS OF WORK SHALL BE CONSIDERED TO BE
CONSTRUCTION TIME ZONE 'A', UNLESS NOTED OTHERWISE
ON DRAWINGS. REFER TO CONSTRUCTION WORK TIME
LEGEND BELOW.
CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY TO
VERFY ALL DIMENSIONS AND EXISTING CONDITIONS ON THE
JOB BEFORE PROCEEDING WITH THE WORK. DISCREPANCIES
(IF ANY) ARE TO BE REFERRED TO THE C.O.R.
THE AREAS OF WORK WILL BE OCCUPIED DURING
CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL
SAFEGUARDS FOR PERSONNEL, PATIENTS, AND EQUIPMENT
WITHIN ROOM AREA WHERE CONSTRUCTION IS BEING
ACCOMPLISHED. THE CONTRACTOR SHALL NOTIFY THE COR
NO LATER THAN 2 WEEKS PRIOR TO CONSTRUCTION IN ANY
GIVEN ROOM FOR COORDINATION WITH STAFF PERSONNEL
AND PATIENT NEEDS.
THE CONTRACTOR SHALL ESTABLISH AND MAINTAIN A DUST
CONTROL PROGRAM AS PART OF THE CONTRACTORS
INFECTION PREVENTATIVE MEASURES. REFER TO
SPECIFICATION 01 00 00 FOR INFECTION PREVENTION
MEASURES. AS WELL AS SPECIFICATION 01 35 26 SAFETY
REQUIREMENTS.
ALL SURFACES DAMAGED DURING DEMOLITION AND
INSTALLATION WORK SHALL BE PATCHED AND REPAIRED TO
NEW CONDITION AND PAINTED TO MATCH ADJACENT
SURFACES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
BUILDING CODES
IBC 2024 INTERNATIONAL BUILDING CODE.
AISC 7-15: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES.
ACI 318-14: BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE AND COMMENTARY.
AISC 14TH ED : STEEL CONSTRUCTION MANUAL.
AISI S200-12: NORTH AMERICAN STANDARD FOR COLD-FORMED
STEEL FRAMING – GEN. PROVISIONS
L M
6.7
63 SF
TOILET
2H-134B
ANTE RM
2H-134
CORRIDOR
C2-25
COMM CTR/WARD
CLK
C2-19
620 SF
WAITING ROOM
2H-135
2H -1
B
VI
F
4'
0"
VIF
3' - 10 3/4"
8.2
F G
190 SF
WAITING ROOM
2J-138
EXAM RM
2J-137
CORRIDOR
C2-10
EXAM RM
2J-139
EXAM RM
2J-142A
65 SF
TOILET
2J-138A
2J-138A
VI
F
4'
3/
4"
VIF
4' - 0"
8.2
K L
58 SF
OFFICE
RESEARCH
3J-102
CORRIDOR
C3-3
WAITING AREA
C3-1
54 SF
MENS TOILET
3J-100
56 SF
WOMENS TOILET
3J-101
BATH
3J-103B 3J
-1
3J -1
3J -1
VI
F
4'
3/
8"
VIF
4' - 3 3/8" LEGEND:
EXISTING WALL TO REMAIN
NEW PARTITION, SEE SHEET AE501
APPROXIMATE AREA OF STRUCTURAL INFILL
AT THE EXISTING DUMBWAITER SHAFT,
VERIFY ACTUAL SIZE.
CONCRETE PATCH INFILL SHALL MATCH
EXISTING SLAB THICKNESS AND STRENGTH.
(THIS SHEET ONLY)
CONSTRUCTION WORK TIMES:
WEEKDAYS: MONDAY THRU FRIDAY
(START 7:00 AM AND END 4:00PM)
TIME ZONES WORK DAYS AND WORK DURATION
WEEKENDS: SATURDAY AND/OR SUNDAY
(START 8:00AM AND END 3:00PM)
WEEKDAY NIGHTIME: MON. THRU FRI.
(START 6:00PM AND END 5:00AM)
A
B
C
TN
N
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:0
AM
SE100
STRUCTURAL FLOOR PLANS AND
GENERAL NOTES
FEBRUARY 2026 JME RJF
SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED (1EF-122 &123)1
4' 8'0 2'
SCALE:1/4"=1'-0"
SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED (2H-134B )2
SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED (2J-138A )3 SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED (3J-100 & 3J-101 )4
A
A
A
A
FENCE
FENCE
CUBICAL WALL
SCISSOR LIFT MOTOR
ICE
MACH
WASHERAREA
HOLDING
STEAMER
STAINLESS STEEL
STERID UNIT
CONVEYOR BELT
BB-140
BG-115A
BF-110A
BE-103A
CB-52
BG-115A
BG-131A
BB-162
BB-140A
BA-103A
BB-121
CB-29D
BF-104
BF-113
BF-112
BF-114 BF-115
BE-116
BE-116A
CB-35A
BE-114
BE-109
BE-108
BE-107
BC-100
BC-103
BC-105 BC-104
BC-107
BD-106
BD-102A
BD-
BC-110
BC-118
BC-117B
BC-114
BC-122B
BC-123C
BC-122A
BC-123A
BC-127C
BC-127
BD-115ABD-116A
BD-117A
BD-112
BD-110
BD-116
BD-33
BD-107A
BD-103A
BB-155
CB-48
BC-103
BC-107A
BD-101
BF-105
CB-29B
CB-29C
BG-124
BC-122
CB-12
D-2
BC-102
BC-128
BC-138
CB-24
BC-116
BB-146
BB-147
BB-150
CB-53
CB-29A
BC-125D
CB-42CB-41
CB-8
CB-8A
CB-9
CB-10
BF-101BF-102BF-103
BB-154
BG-109
BG-100
BG-105
BG-107
BE-112
BE-113
CB-38
BC-126JBC-126IBC-126HBC-126GBC-126F
BC-126E
CB-19
BB-141 BB-133
BA-102D
BF-118
CB-6
CB-7
CB-14
CB-15
CB-16
BB-107
CB-17
CB-18
BB-100
BB-101
BB-112
BB-115
BB-116
BB-114
BB-113
BB-102
BB-165
BB-104
BB-137
CB-13A
CB-22
NO-5
CB-28
CB-5
BA-105
BA-102C
BA-104
BA-103
BA-100
BA-101
BA-104B
BA-106
BA-102
BA-102A
BA-102B
BA-101B
BE-103
BD-103
BD-104
BD-117
CB-30
BD-117B
BD-118
BE-100A
BE-101
BE-102
BE-117
BE-115
CB-37
BE-118
CB-45
BG-138
CB-15
BB-153 BB-122
BB-123
BB-125
CB-20
BB-129BB-145
CB-21
BF-110
BF-116
BF-109
BB-157 BB-152
BB-149
BB-153
BC-101
BC-101A
BC-109
BC-106
NO-1
BE-104
BE-105
BE-106
BE-111
BE-110
BE-100
BD-100
BD-117C
BG-121
BG-121A
BG-120
BG-119
CB-44
NO-3
BF-117ABF-117
CB-39
CB-40
NO-2
S-4
BF-108
BF-106C
BF-106
BF-106B
BF-107
BF-106A
CB-11
P-3
BG-117
BG-123
BG-125BG-116
BG-127BG-114
BG-112
BG-128
BG-129BG-111
BF-110D
BG-115D
BG-115C BG-115B
BG-115E
BG-115F
BG-115G
BG
BG-103 BG-104
BG-110
CB-43
BG-122
BG-126A
BG-126
BG-126D
CB-46
BG
126B
BG-126C
BG-131
BG-132
BG-139
BG-137
BG-135
BG-134
CB-47
BG-108 BG-136
BG-133BG-106
CB-49
BG-101
BG-102
CB-50
CB-51
BF-110C
BF-110B
BC-131
BF-111A
BF-111
S-1 S-2 S-3
CB-36
CB-32
CB-34
BD-109
BD-107
BD- 105
BD-111
NO-8
BD-119C
BD-122A
BD-122
BD-123A
BD-123
BD-124
NO-7
CB-35
CB-27
BD-114C
BC-113
BC-111
BC-112
BC-115
BC-117A
BC-117
BC-121
BC-120BC-119
BD-115 BD-114
BD-114B
BD-108
BD-133
CL-2
BD-114A
BB-109
BB-105BB-136 BB-106
BB-108BB-134
BB-117BB-128
BB-119BB-126
BB-110BB-132
BB-111BB-130
BB-120BB-124BB-151
BB-127BB-148
BB-143 BB-131
BB-135
BB-139
BB-163
BB-161
BB-160
BB-159
BB-158
CB-23
BB-142
BB-138
BB-164
BC-127B
BC-127A
NO-4
BC-123B
BC-123
BC-124
BC-126
BC-125
BC-125KBC-125JBC-125IBC-125E
BC-125F
BC-125G
BC-125H
BC-125C BC-125B BC-125A
BC-126D
BC-126C BC-126B BC-126A
BC-122C
P-1
P-2
CB-13
BB-103
BC-108
BD-121 BD-120
BD-119
BD-119B BD-119A
TUNNEL BELOW GRADE
DOCK LEVELLER DOCK LEVELLER
SCISSOR LIFT PIT
SLOPE 1/2"
R A M P
D O W N
AUTOPSY ENTRANCE
TUNNEL BELOW GRADE
CHUTE
DROP CHUTE
T O
B
LD
G
T O
B
LD
G
SUPPLY PROCESSING AND
DISTRIBUTION
SPD
PIT BELOW 1' 2" WIDE AND 1' 6" DEEP
SIM TO DET. 3/UT-A4
SCISSOR LIFT UP DOWN
PUSH BUTTON CONTROL
4' 0" ABOVE FIN. FLOOR
TO BLDG 2A
TO BLDG 2A
INFORMATION
DESK
TO BLDG 5
CRAWL SPACE
DN
UP DN
DN
UP
FEC
CLEAN
UTILITY
CLEAN
LINEN
TELE
ELEVATOR/ MACH RM
CORRIDOR
TOILET
MEDICINE RM
TELECOM
TELEPHONE
FP
TOILET
STORAGE
CORRIDOR
PRESCR
REC
PRESSURE RM
TOILET
HAC HOUSE
KEEPING
TELE ELECTRICAL
FP
TOILET /
LOCKER
SHOWER
CORRIDOR
MECH RM
pxqc;MED GAS STORE pxqc;MED GAS STORE pxqc;FLAMM STORE
HAC
STORAGE
WHCH
TOILET
WHCH
TOILET
ARM AND LEG
WHRLP
EQUIP WASH
FEMALE TOILET
FEMALE SHOWER/ LOCKER
TOILET
EQUIP / STRET
STORAGE WHCH
TOILET
WHCH TOILET
MALE
TELECOM
WOMENS TOILET
TOILET
MENS TOILET
STORAGEFP
HAC
SOIL
UTILITY
MALE TOILETFEMALE TOILET
CART
DRY
HAC
HOUSE
KEEPING
EQUIP GAS
CYLINDER
STORAGE
WOMENS
LOCKER
PASSAGE
WAY
TOILET
STERILE PREPARATION
RM
SECY /
WAITING
MULTIPURPOSE
MULTIPURPOSE
NURSE
STATION
DRESSING
HUBBARD
TANKS
BATTERY RECHARGE
RECEPT /
PHARM
CORRIDOR
PRIMARY
CARE
NURSE
WAITING
WAITING RM
STORAGE
LINEN
BLDG
MGMT
IV
ADMIXTURE
CORRIDOR
OCCUPATIONAL
THERAPY
CASH
CART
TUMOR
REGISTRATION
EXAM /
TREATMENT
CORRIDOR
CORRIDOR
WORK RM
CORRIDORCORRIDOR
WAITING RM
RECEPTION
WAITING RM
WAITING
CONSULT RMCONSULT RMCONSULT RM
TRAINING RM
SECY
POD EXAM
OFFICE
POD EXAM
POD EXAM
AUTOPSY RM
MORT
REFRIG
MORGUE
CORRIDOR
WORK RM
EXAMEXAMEXAMEXAM
EXAM
TREAT
CORRIDOR
OFFICE OFFICE
SVC BAY
CONCOURSE
WAITING RM
WAITING RM
CORRIDOR
CORRIDOR
EXAM /
TREATMENT
CORRIDOR
NURSE STATION
TOILET
MALE
WOMENS TOILET
EXAM /
TREATMENT
OFFICE
SOCIAL WORKER
IT
SPECIALIST
OFFICE
OFFICE
ELECTRICAL
SVC BAY DIABETIC
CLASS RM
SVC BAY
STAIR
RECEPTION
CORRIDOR
STAIR
CORRIDOR
LOBBY
OFFICE
OFFICE
AGENT CASHIER
OFFICE
WOMENS TOILET
MENS TOILET
AGENT CASHIER
OFFICE-A OFFICE-B
OFFICE IDRM OFFICE C
CAFE
OFFICE
STORAGE
MECH
DECONTAM RM
AITO
CARTWASH
EQUIP STORAGE AND TEST
CORRIDOR
DISPATCH
AREA
SVC BAY
PAP AND
EMP
CLOTHING
ELECTRICAL
ELECTRICAL
EMS
HAC
CORRIDOR
GROSS SPEC
STORE
CORRIDOR
TELECOM
CONCOURSE
OFFICE OFFICE
EXAM /
TREATMENT
EXAM /
TREATMENT
CORRIDOR
SOCIAL WORKER
EXAM /
TREATMENT
CORRIDOR
PHARMACY
SVC BAY
VAULT STORAGE
/ DISPENSE
CHIEF RMS
CLINICAL
DIETITIAN
OFFICE
ASST
CHIEF
CHIEF
MEN
TOILET
PHYS
THERAPY
TREATMENT
WORK AREA /
OFFICE
OFFICE
/ WORK
AREA
STAIR
PHARMACY
STORAGE
OFFICE
STAFF TOILET
BREAK RM
TELE
ELECTRICAL
STERILE
OPEN
OUTSIDE
AREA WAY
TRANSFORMER RM 4
SWITCH BOARD
TELE
SIGNAL
SVC BAY
CORRIDOR
STAIR
SWITCH
BOARD RMTRANSFORMER
RM
LOBBY
VESTIBULE
STAIR
ELEVATOR
ELEVATOR
ASST
CHIEF
OFFICE
SUPER PHARM
DRUG
INFO
SVC
CLERICAL
OFFICE /
WORK AREA
CHIEF
CONFERENCE
RM
SECY /
WAITING
LOBBY
ELEVATOR
LOUNGE EXAM/
TREATMENT
OFFICEOFFICE
EXAM/
TREATMENT
EXAM/
TREATMENT
EXAM /
TREATMENT
OFFICE
CLEAN
UTILITY
SOILED UTILITY
BREAK RM
EXAM RM
EXAM RM EXAM RM
EXAM RM
EXAM RM
OFFICE
EXAM RM
ELECTRICAL OFFICE PROC RM
CORRIDOR
HAC
EXAM RM
CORRIDOR
EXAM RM
CORRIDOR
EXAM RM
OFFICE
OFFICE
OFFICE
ELECTRICAL
OFFICE
EXAM
EXAM
CORRIDOR
EXAM /
TREATMENT
EXAM /
TREATMENT
OFFICEOFFICE
CORRIDOR
NURSE
SOCIAL WORKER
CORRIDOR
CORRIDOR
PHARMACY PULM
IV ADMIXTURE STORAGE
AREA
CLEAN LINEN
STORE
KEMO RM
IV
ADMIXTURE
ELEVATOR ELEVATOR ELEVATOR
S ELEVATOR
LOBBY
CORRIDOR
HALLWAY
ELEVATOR /
MACH
MALE
SHOWER
HAC
OFFICE
STAIR
CORRIDOR
ELECTRICAL
TRANSFORMER RM 2
SVC BAY
MECH
STORAGE
SVC BAY
ENG CONTR
CENTER
STAIR
CORRIDOR
CORRIDOR
CHIEF
CORRECT
KINESLO
THERAPY
KT EQUIP
STORAGE
OFFICE
THERAPY
WAITING RM
OFFICE
KITCHEN
CLINIC
SPLINTING
EQUIP
STORE
MENS
LOCKERS CLERICAL
ASST
CHIEF
OFFICE
LOUNGE COMPUTER
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
OFFICEOFFICE
CLEAN UTILITY
BIO
HAZARD
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM /
TREATMENT
OFFICEEXAM /
TREATMENT
CLINICAL DIETITIAN
ELECTRICAL
SPEECH
PATHOLOGY
RMS
COORDINATION
PATIENT HEAD
CORRIDOR
HOUSE KEEPING
COPY RM
LOUNGE
SPEECH
PATHOLOGY
CLEAN LINEN
CLEAN SUPPLY
STAIR
MEDS
EDUCATION OFFICE
LOUNGE
NURSE STATION
NURSE STATION
EXAMEXAMEXAMPROCEDURE EXAM RM EXAM WORK RM
EXAM EXAM EXAM
WORK RM EXAM EXAM EXAM
RECEPTION
ELEVATOR
ELEVATOR
WAITING RM
MULTI PURPOSE
SHAFT
ELEVATOR
CORRIDOR
SHAFT
SHAFT
TOILET
TOILET
CORRIDOR
ELEVATOR
CORRIDOR
ELECTRICAL
EMD-PAP ANTI ROOM
FEMALE LOCKER
FEMALE TOILETFEMALE TOILET
REMOVABLE GAL. STEEL
GRATING W/BEARING BAR
FIRE PROTECTION
FP
ROLL UP DOOR ROLL UP DOORROLL UP DOOR
I JE
8.2
K L M
5.3
6.7
NF G
AE400
AE400
AE400
AE400
AD400
AD400
AD400
AD400
AE410
AE410
AE410
AE410
BUILDING 143
KEYPLAN
BUILDING 2A
(N.I.C.)
SHEET NOTES - FLOOR PLAN:
FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
PRIOR TO ORDERING OR INSTALLING ANY MATERIALS OR
EQUIPMENT.
ALL DIMENSIONS TO FINISHED FACE OF WALL, UNLESS
NOTED OTHERWISE.
REFER TO PARTITION TYPE SCHEDULE (ON SHEET AE501)
FOR INTERIOR WALL CONSTRUCTION.
REFER TO INTERIOR FLOOR PLANS (ON SHEETS AE420-
AE423) FOR PARTITION TYPE REFERENCE TAGS.
LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH
FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.
REFER TO PLUMBING DRAWINGS FOR ROUGH-INS.
THE MAJORITY OF EXISTING PARTITIONS ARE ROUNDED
TO 6" THICK, ALIGN EXISTING AND NEW WALL FINISHES,
TYPICAL.
1.
2.
3.
4.
5.
6.
7.
TN
N
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:0
AM
AE100
BASEMENT FLOOR PLAN - OVERALL
FEBRUARY 2026 JME RJF
SCALE: 1/16" = 1'-0"
00 FLOOR PLAN BASEMENT - OVERALL1 32'8'
SCALE:1/16"=1'-0"
0 16'
IC-129
OFFICE
OFFICE
OFFICE
OFFICE
COMMON SPACE
MAS
123A
IB-104A
IC-129F
IC-129G
IEF-122IEF-123
IB-125
IB-124
ID-136
IEF-121
IEF-140
IC-114
ID-101A
ID-142
IC-105
IFG-149
IFG-145A
IFG-118
IFG-117
IC-101
IC-102
IEF-111
107-A
IEF-106IEF-105
IEF-102
IEF-139
160B
160A
159A
IEF-130
IEF-131
IEF-156
IB-116
IB-103
IC-106B
IC-139 IC-141
IC-131B
ID-105
ID-113
ID-128ID-131
ID-104
IFG-112
IC-126A
IC-126E
IC-126G
IEF-113
IEF-143
IC-104
IC-136D
ID-144
ID-134
IEF-135
IEF-133
IC-119
IC-117
IB-102
IB-105
IB-107
IB-109
IB-115
IB-123
IB-117
IB-122
IB-121
IC-128
IC-128A
IB-120
IB-119
IB-118
IB-116A
IB-114 IB-113
IB-112
IB-111
IB-108
IB-106
IB-104
IB-104B
IB-101
IB-100
IEF-127
IEF-124
IEF-118
IEF-119
IEF-119A IEF-120
IEF-120A
CI-56
IEF-116 IEF-115
IEF-112
IEF-114 IFG-119
IFG-120
IFG-122
IFG-121
IFG-135
IFG-134
IFG-126
IFG-128
IFG-124IFG-123
IFG-115
IFG-125
IFG-127 IFG-129 IFG-130
IFG-113
IFG-105
IFG-103IFG-101
IFG-102 IFG-104
IFG-107
IFG-145A
IFG-144
IFG-141
IFG-108
IFG-109
IFG-110
IFG-111
IFG-131
IFG-132
IFG-133
IFG-141C
IFG-141A
IFGI-138C
IFG-138B IFG-138
IFG-140A
IFG-142
IFG-140C
IFG-143
IFG-148A
IFG-148 IFG-151
IFG-140
IA-1028
IEF-110
IEF-108
IEF-103IEF-104
IFG-136
IEF-100A
IEF-100
IEF-101
IFG-137
IFG-137A
IC-100
IEF-109
IEF-117
IEF-707
IEF-128IEF-126B
IEF-129
IEF-129A
IEF-126A
IEF-126
IEF-125
IEF-125A
IC-103
IC-107A IC-107B CI-16
IFG-147 IFG-150
IEF-166
IEF-168
IEF-165
IEF-164
IC-109
IC-106A
IC-106
IC-108
IC-109A
IC-118
IC-116
IC-115
CI-13A
IC-110
IC-111
IC-113
IC-112
IC-125A
IC-125
IC-124
IC-120
IC-121
IC-122
IC-123
IC-126
IC-127
IC-130IC-131
IC-126C
IC-126F
IC-126D
IC-131A
IC-133
IC-145
IC-143
IC-143B
IC-143A
IC-138
IC-135A
IC-134B
IC-134A
CI-20
IC-142
IC-137
IC-140
IC-136C
IC-136
IC-133A
IEF-163
IEF-161
IEF-159
IEF-160
IEF-167
IEF-169
IEF-171
IEF-132IEF-134
IEF-136IEF-137
IEF-172
IEF-138IEF-141
IEF-142
IEF-144
IEF-145
IEF-146
IEF-148
IEF-147
IEF-152
IEF-153
IEF-155
IEF-154
IC-136B
IC-136A
IEF-158
ID-100
ID-102A
ID-102BID-102
ID-108ID-109
ID-114
ID-106
ID-118
ID-124
ID-117
ID-119
ID-123
ID-101
ID-101B
ID-121
ID-122
ID-125 ID-126
IC-132
ID-127
ID-129
ID-130
ID-132
ID-133
ID-137
ID-138
ID-139
ID-140
ID-143
ID-116
ID-115
ID-112
ID-111
ID-110
IC-129M
IC-129L
IC-129G
IC-129Q
IC-129P
IC-129N
IC-129M
IC-129L
1C-129K
1C-129J
1C-129H
IC-129B
IC-129C
IC-129D
IC-129
IC-129E
IC-129A
CI-66
CI-59
TOILET
TOILET
TOILET
TOILET
TOILETTOILET
TOILET
TOILET
TOILET
WOMENS TOILET
MENS TOILET
CHASE
CHASE
FP
ISOLATION RM
HOUSE KEEPING
HOUSE
KEEPING
TOILET
TOILET
DIRTY
UTILITY RM
HOUSE
KEEPING
ELECTRICAL
STORAGE
WOMENS TOILET
MENS TOILET
HOUSE KEEPING
HOME 02
CO-ORDR
OFFICE
TOILET
OFFICESTORAGE
HOUSE
KEEPING
STORAGE
STORAGE
STORAGE
STORAGE
FEMALE TOILET
MALE TOILET
WOMENS TOILET
ISOLATION RM
HOUSE
KEEPING
REST RM
CLOSET CONTROL RM
STORAGE
CLEAN
LINEN
MED
RM
SHAFT
BATH RM
CHASE
STAFF
TOILET
HOUSE
KEEPING
TOILET
WAITING
AREA
WAITING
AREA
NURSING STATION
SOUND BOOTH
SCRUB
AREA
WORK AREA
PULM
OFFICE
OFFICE
STORAGE
CLEAN LINEN
MEDICATION RM
ELEVATOR
ELEVATOR
ELEVATOR
EXAM
EXAM
RECP
EYE
OFFICE
NURSE STATION
ANTE RM
ISOLATION RM
SUPPLY
CLEAN LINEN
MED RM
STORAGE
NURSE STATION
LOUNGE
BIO-
HAZARD
ON-CALL
OFFICE
ELECTRICAL
IRM
MECH RM
GAS
STORAGE
EQUIP STORAGE
MECH
STORAGE
SUPPLY
CORRIDOR
LOUNGE
OFFICEADMIN
OFFICE
CORRIDOR
CORRIDOR
STAIR
CORRIDOR
ELEVATORELEVATORELEVATOR
OFFICE
OFFICE
OFFICE
RESIDENT OFFICE
MULTIPURPOSE OFFICE
OFFICE
CORRIDOR
OFFICE OFFICE
PULM
OFFICE
CORRIDOR
OFFICE
OFFICE
OFFICE
EXAM RM
EXAM RM
HOUSE KEEPING
EXAM RM
EXAM RM
TECH
CORRIDOR
ELECTRICALOFFICE
WAITING RM
EXAM RM
MED
TECHNICIAN
OFFICE OFFICE VISUAL FIELD
OFFICE SOUND BOOTH
CORRIDOR
AUDIOLOGYEYE
CLINIC
EYE
CLINIC
REHABITATION
MEDICINE /
AUDIOLOGY
AUDIOLOGY AUDIOLOGY AUDIOLOGY
AUDIOLOGY
TECHNICIANS
RM
CONFERENCE
RM
SLIDE
STORAGE
BOOTH
BOOTH
BOOTH
BOOTH
EYE SURGY
EXAM RM
EXAM RM
WOMENS
TOILET
MENS
TOILET
MENS TOILET
FEMALE TOILET LOUNGE
LAB
CORRIDOR
OFFICE
HISTOLOGY
COPY RM
HOUSE KEEPING
IRM
HOUSE KEEPING STORAGE
HISTOPATHOLOGY CYTOLOGY LAB
CORRIDOR
OFFICEMULTIPURPOSE
RM
ELECTRICALIRM
CORRIDOR
STAIR
SVC BAY / MECH
LOCKER
WOMENS
TOILET
SVC BAY / MECH
STAIR-2
ELEVATOR
CORRIDOR
CORRIDOR
ON-CALL
TOILET
ELECTRICAL CLOSET
CHIEF PULM
OFFICE
CONFERENCE RM
LAB
OFFICESTORAGE
PULM
OFFICE
OFFICE
OFFICE
OFFICE
KITCHEN
HOUSE KEEPING
LOCKER TOILET OFFICE
OFFICE OFFICE OFFICE
WOMEN
MEN
STORAGE
LINEN
OFFICE
STORAGE
OR-8
OFFICE
OFFICE
PACU
OFFICE
ANEST
OFFICE
OFFICE
NURSE
STATION
RECOVERY
WAITING RM
BIO-
HAZARD
BREAK RM
STORAGE
OFFICE
CORRIDOR
STAIR
OFFICE
IRM
WORK RM
OR-1
CONTROL RM
OR-2OR-3
ELECTRICAL RM
HOUSE KEEPING
CLEAN
CORE
OR-4
OR-7
OR-6
STORAGE
STORAGE
OR-5
WOMENS TOILET
STORAGE
MENS TOILET
CORRIDOR
SURGY LOUNGE
UTILITY RM
IRM
HOUSE KEEPING
OFFICE
RESP
THERAPY
SUPPLY
EQUIP
RM
ELECTRIC RM
CORRIDOR
CATH
LAB
CONTROL RM
IRM
EKG
OFFICE
EKG
OFFICE
OFFICEOFFICE
EKG
CORRIDOR
OFFICE
EXERCISE RM
CONFERENCE
RM
OFFICE
OFFICE
OFFICE
ECHOCARDIOGRAM
OFFICE
OFFICE
EQUIP
RM
CORRIDOR
OFFICE
OFFICE
LOCKER
OFFICE
WAITING RM
TOILET
STORAGE
SPD
STORAGE
CORRIDOR
LOUNGE
STORAGE
IRM
OFFICE
PATIENT
NOURISHMENT
RM
ELECTRICAL
OFFICE
WORK RM
CCLO
LOCKER RM NIGHT CALL RM
NIGHT CALL RM
OFFICE STORAGE
MECH RM
STAIR
EQUIP
STORAGE
STAFF
LOUNGE
STAFF
WORKERS
CORRIDOR
PATIENT RM
PATIENT RM
PATIENT RM
CORRIDOR
PATIENT RM
PATIENT RM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
WAITING ROOM
CONFERENCE RM.
OFFICE
OFFICE
OFFICE
COMMON SPACE
COMMON SPACE
CATH
LAB
TO BUILDING 4
DNUP
98 SF
126 SF
114 SF
754 SF
1173 SF
587 SF 489 SF
81 SF
49 SF
48 SF
105 SF
64 SF
141 SF
308 SF
BUILDING 143
KEYPLAN
BUILDING 2A
(N.I.C.)
I JE
8.2
K L M
5.3
6.7
NF G
AE401
AD401
AE411
AD401
AE401
AE411
AE401
AD401
AE411
SHEET NOTES - FLOOR PLAN:
FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
PRIOR TO ORDERING OR INSTALLING ANY MATERIALS OR
EQUIPMENT.
ALL DIMENSIONS TO FINISHED FACE OF WALL, UNLESS
NOTED OTHERWISE.
REFER TO PARTITION TYPE SCHEDULE (ON SHEET AE501)
FOR INTERIOR WALL CONSTRUCTION.
REFER TO INTERIOR FLOOR PLANS (ON SHEETS AE420-
AE423) FOR PARTITION TYPE REFERENCE TAGS.
LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH
FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.
REFER TO PLUMBING DRAWINGS FOR ROUGH-INS.
THE MAJORITY OF EXISTING PARTITIONS ARE ROUNDED
TO 6" THICK, ALIGN EXISTING AND NEW WALL FINISHES,
TYPICAL.
1.
2.
3.
4.
5.
6.
7.
TN
N
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:0
AM
AE101
1ST FLOOR PLAN - OVERALL
FEBRUARY 2026 JME RJF
32'8'
SCALE:1/16"=1'-0"
0 16'
SCALE: 1/16" = 1'-0"
01 FLOOR PLAN - OVERALL1
2J-167
NO.
2H-108
2J-118
2H-100
2H-110B2H-110A
2H-122A
2H-112A
2J-106A
2H-109
2H-134
2H-126
2H-129A
2H-127B
2J-178
2J-166A
2J-155
2J-152
NO. 1
2J-155B
2J-116A
2J-113A
2J-105B
2J-105
2J-104
2J-118B 2J-112
2J-111A
2J-108
2J-106
2J-137B
2J-124A
NO. 4
2J-135
2J-130A
2J-134A
2J-131A
2J-130
2J-107
2J-102B
2J-148 2J-168
2J-168
2H-134B
2H-125A
2H-121C
2H-101
2J-155A
2H-135
2J-100
2H-106D
2J-162
2H-116A
2H-114
C2-20
2H-133
2H-124
2H-1312H-116
C2-23
2H-113
2H-115
2H-110
C2-19
2H-102
2H-103
C2-24
C2-25
C2-21
2H-132 2H-130
2H-130A
2H-129 2H-128
2H-124A
2H-128A
2H-127A
2H-127
2H-125B
2H-125C
2H-122C
2H-123
2H-122B
C2-22
C2-24A
2H-121B
2H-120 2H-121A
2H-117A
2H-119 2H-118C
2H-118B
2H-118A 2H-118
2H-1172H-112
2J-157
2H-108 2H-107
2H-106C2H-106B
2J-106
2J-175
2J-176
2J-171
2J-172
2J-173
2J-166
C2-17
2J-153
2J-160
2J-154
2J-146
C2-16
C2-15
C2-14
C2-12
C2-13
2J-177 2J-174
2J-1652J-164
2J-164A
2J-1612J-159
2J-158
2J-156A
2J-156
2J-153
2J-151
2J-150
2J-145
2J-147
2J-149
C2-2
C2-1
C2-18
P-1
P-2
P-3
2J-170
S-3S-2S-1
C2-11
2J-102
2J-102A
2J-101
C2-3
2J-110
2J-118
2J-121
2J-1092J-123
C2-5
2J-141
2J-124
C2-4
C2-8
2J-122
2J-133
2J-140
2J-113
2J-111
2J-108B
2J-108A
2J-105A
2J-103
C2-8
2J-144
2J-143
2J-142 2J-142A
2J-138A
2J-1392J-138
2J-137A
2J-137
2J-138A
2J-138
2J-134C
C2-10
2J-134
2J-134B
2J-132
2J-131
2J-131C
2J-131B
2J-130C
2J-130B
C2-9
2J-114B
2J-114A
2J-114
2J-114C
C2-8A
2J-114D
2J-115
2J-116
2J-117
2J-120
2J-125
2J-1262J-127
2J-128A
2J-128
C2-7
2H-111
2J-179
2J-119
ELECTRICAL
STAIR
TOILET
WHCH
TOILET
ACV
STORE
STR SHOWERWHCH TOILET
BATH
BATH
STORAGE
HAC
ANTE
RM
COMMON
CLOSET
BATH
CLOSET
INTAKE RM
STORAGE
BREAK
RM
NUTRI CTR
STAIR
STAFF
TOILET
BATH
BATH
BATH
ANTE
RM
STORE
SHOWER
HAC
BATH
ANTE
RM
TELE
MED RM
STAIR
VACANT
BATH
CLOSET
BATH
BATH
ALCOVE
STAFF TOILET
TOILET
VISITORS TOILET SOILED LINEN
TRASH
DUMB
WAITER - 2
BATH
BATH
BATH
STAFF TOILET
LOCKER
WAITING RM
MALE
TOILET
EXAM
RM
SOILED
UTILITY
MED RM
PHYS ASST
CORRIDOR
CLEAN
UTILITY
PRE ADMIT
INT ROD
SOILED
UTILITYBREAK RM
OFFICE /
WORK RM
ELECTRICAL
ORTHO MD
OFFICE
CAST RM
COMM CTR / WARD CLK.
OFFICE
CODER
CORRIDOR
CORRIDOR
CORRIDOR
EXAM
RM - 1
MD / RN
WORK RM
BATH
EXAM RM -
EXAM RM - 1
CORRIDOR
EXAM RM
EXAM RM
EXAM RM -
PRE
ADMISSION
PRE
ADMISSION
EXAM RM
CLEAN LINEN
EXAM RM
CORRIDOR
CORRIDOR
EXAM RM
X-RAY
STORAGE EXAM RM
WAITING
RM EXAM
RM
EXAM
RM
EXAM RM
EXAM
RM
EXAM
RM
EXAM RMEXAM RM
1 -
BED RM
EXAM RM
EXAM RM
STORAGE
EXAM RMEXAM RM
EXAM RM
WAITING
CHECK-IN
EQUIP STORAGE
CAPD ED
TELE
PHARMACY
HAC
CLASS RM
CORRIDOR
CLEAN SUPPLY
CLEAN
UTILITY
NURSE MGR
CLINIC RN
CORRIDOR
NURSE STATION
CORRIDOR
WAITING
RM
CORRIDOR
H
BIOMED
MACH STOMACH STO
RE-USE RM
SET-UP
RM
6 - STATIONS
5 - STATIONS
BATH
1 - BED RM
CHIEF
RENAL
RESEARCH
DR OFF
SECY
INTAKE
LOUNGE
VISITORS
LOUNGE
LOBBY
CORRIDOR
BLDG MNT
S ELEVATOR LOBBY
LOUNGE
FEMALE
LOCKER
FEMALE
TOILET
CORRIDOR
INTAKE
DERMATOLOGY
ELECTRICAL
TUMOR REG
NURSE
PRACT
CORRIDOR
CLEAN
UTILITY
NOUR STA
COMM CTR
STAFF WORK AREA
LOUNGE /
EDUCATION
INTAKE
SOILED UTILITY
EXAM RM
EXAM RM
BATH
EXAM RM
EXAM RM
WAITING RM
CORRIDOR
FILE RM
CLINIC
WALK-IN
INTAKE
/ TRIAGE
EXAM RM
BATH
EXAM RMWAITING
EXAM RM
EXAM
RM
EXAM
RM
EXAM
RM
RESIDENT EXAM RM
CORRIDOR
ALCOVE
EXAM RM
LINEN
CLOSET
ALCOVE
EXAM RM
EXAM RM
EXAM RM
EXAM RM
CORRIDOR
EXAM RM
EXAM RM
EXAM RM
EXAM RM
CORRIDOR
EXAM RM
EXAM RM
SCREENING
RM
OFFICE
EXAM RM
SCREENING
RM
EXAM RMEXAM RM
EXAM
RM
EXAM
RM
CORRIDOR
EXAM
RM
CORRIDOR
SVC BAY
ORTHO EXAM RM
SVC BAY
ELEVATOR ELEVATOR ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
CG
DN
UP
DN
UP
DN
DN
UP
DN
LOCKERS
I JE
8.2
K L M
5.3
6.7
NF G
AE402
AE402
AE402
AD402
AD402
AD402
AE412
AE412
AE412
SE100
SE100
BUILDING 143
KEYPLAN
BUILDING 2A
(N.I.C.)
SHEET NOTES - FLOOR PLAN:
FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
PRIOR TO ORDERING OR INSTALLING ANY MATERIALS OR
EQUIPMENT.
ALL DIMENSIONS TO FINISHED FACE OF WALL, UNLESS
NOTED OTHERWISE.
REFER TO PARTITION TYPE SCHEDULE (ON SHEET AE501)
FOR INTERIOR WALL CONSTRUCTION.
REFER TO INTERIOR FLOOR PLANS (ON SHEETS AE420-
AE423) FOR PARTITION TYPE REFERENCE TAGS.
LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH
FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.
REFER TO PLUMBING DRAWINGS FOR ROUGH-INS.
THE MAJORITY OF EXISTING PARTITIONS ARE ROUNDED
TO 6" THICK, ALIGN EXISTING AND NEW WALL FINISHES,
TYPICAL.
1.
2.
3.
4.
5.
6.
7.
TN
N
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:0
AM
AE102
2ND FLOOR PLAN - OVERALL
FEBRUARY 2026 JME RJF
SCALE: 1/16" = 1'-0"
2ND FLOOR PLAN - OVERALL1 32'8'
SCALE:1/16"=1'-0"
0 16'
BATH
TELECOM
ELECTRICAL
BATH
BATH
FEMALE TOILET
STAFF TOILETTELEPHONE
EQUIP.
STORAGE
CLEAN
SUPPLY
BATH
GENERAL
STORAGE
BATH
ANTE RM
BATH
BATH
GENERAL
STORAGE
CLEAN
LINEN RM
BATH
BATH
BATH
MENS
TOILET
LINEN
TRASH
BATH
BATH
EQUIP. ALCOVE
BATH
STAFF TOILET
EQUIP
STORAGAE
BATH
ANTE RM
GENERAL
STORAGE
EQUIPMENT
STORAGE
BATH
BATH
BATH
TEL
CLOSET
BATH
TREATMENT/ EXRAY RM
CORRIDOR
CORRIDOR
OFFICE
CORRIDOR
CORRIDOR
X-RAY
BED RM
BED RM
BED RM
GENERAL STORAGE
BED RM
OFFICE
OFFICE
EXAM
EXAM
EXAM
BATH
EXAM
EXAM
BATH
EXAM
STAIR
MECH
HAC
MECH SHAFT
WORK RM
EXAMEXAM
EXAM
CLOSET
2 - BED
PATIENT RM
BATH
2 - BED
PATIENT RM
LOUNGE
GI
PROCEDURE
RM
PROCEDURE RM
NURSING STATION
KITCHEN
CLEAN
SUPPLY
MED RM
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
DAY RM
OFFICE
OFFICE
CORRIDOR
EXAM
OFFICE
OFFICE
LOUNGE/
BREAK RM
CLEAN EQUIP RM
NURSING STATION
STAFF RM
COMPUTER RM
DIRTY UTILITY
SLEEP LAB
BATH
EXAMEXAMEXAMEXAM
WAITING AREA
BATH
OFFICEOFFICE
TELECOM
FOOD
STORAGE
OFFICECORRIDOR
LECTURE HALL
LECTURE HALL
CONFERENCE RM
STORAGE
OFFICE
OFFICE
SVC ELEVATOR LOBBY
ELECTRICAL
CORRIDOR
HOUSE
KEEPINGSTAIR
MENS
TOILET
WOMENS TOILETOFFICE
RESEARCH
PROCEDURE RM
CORRIDOR
2 - BED
PATIENT RM
PATIENT RM
ANTE RM
CORRIDOR
CORRIDOR
OFFICE
EQUIP
STORAGE
NURSE
MGR
OFFICE
NEUROLOGY
PAIN
NURSE STATION
EQUIP.
STORAGE
LOUNGE
DIETITIAN
CLEAN
STORAGE
NURSE STATION
KITCHENSOILED UTILITY
VISITORS RM /
WAITING RM
BATH
PATIENT RM
BATH
PATIENT RMPATIENT RM
2 - BED
PATIENT RM
LINEN
STORAGE
4 - BED
PATIENT RM
4 - BED
PATIENT RM
OFFICE
EXAM /
TREATMENT RM
SVC BAY
MECH SHAFT
HOUSE
KEEPINGSTAIR
EQUIPMENT
STORAGE
BATH
TREATMENT RM
2 - BED PATIENT RM
PROCEDURE RM
EXAM
EXAM
EQUIPMENT
STORAGE
EQUIP.
STORAGE
2-BED
PATIENT RM
D N
U P
U P
D N
D N
3J-114A
3J-105
3J-119
3H-129A
3J-112A
3J-150
3H-1413H-139
3H-126A
3H-126
3H-133A
3H-132
3H-108F
100A
3H-102A
3H-111A
3H-120
3H-113
3H-114A
3H-119A
3H-108A
3J-145
3J-154
3J-155
3J-103B
3J-107A
3J-110A
3J-104A
3J-106
3J-117B
3J-141B
3J-141 3J-142
3J-127
3J-128A
3J-129A
3J-132A
3J-133
3J-125A
3J-132
C3-13
C3-12
3H-100
C3-10
C3-9
3J-111
3H-107
3H-108B
3H-108C
3H-108E 3H-108D
3H-109
3H-111
3H-114
3H-119
3H-121
3H-121A 3H-122
3H-123
3H-123A
3H-124
NO - 3
3H-125
3H-127
3H-128
3H-1293H-1303H-131A
3H-130B 3H-130A
3J-135
3J-134A
3J-125
3J-151
3J-112
3J-113
C3-15
3H-103
3H-118
3H-117
C3-16
C3-17
C3-20
C3-21
3H-140
3H-138
3H-136
C3-18
3H-133
3H-137
3H-135
3H-134
3H-129A
C3-19
3H-115
3H-112
3H-105
3H-131
3H-108 3H-104A
3H-1063H-1043H-1023H-101
C3-1
100B
3J-1583J-157
3J-159
P-3
3J-160
3J-152C4-14
3J-149
3J-147
3J-146
3J-146A
3J-144B
3J-144 S-1 S-2 S-3
C3-11
3J-153
P-3
C3-3
P-3
3J-156NO - 3
3J-1003J-101 3J-102
3J-103A
C3-5 3J-110
3J-104
3J-103
C3-6
C3-8
3J-108
3J-117
3J-109
3J-120
C3-7
3J-121A
3J-122
3J-130 3J-121
C3-4
3J-1403J-138
3J-143
3J-139A
3J-139
3J-136A
3J-1373J-136
3J-134
3J-131
3J-129
3J-128
3J-114
3J-115
3J-118
3J-116NO - 3
3J-123
3J-123A
3J-124
3J-126
3J-141A
3H-126B
3J-117A
3J-107
PODIATRY
I JE
8.2
K L M
5.3
6.7
NF G
AE402
AD402
AE412
SE100
BUILDING 143
KEYPLAN
BUILDING 2A
(N.I.C.)
SHEET NOTES - FLOOR PLAN:
FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS
PRIOR TO ORDERING OR INSTALLING ANY MATERIALS OR
EQUIPMENT.
ALL DIMENSIONS TO FINISHED FACE OF WALL, UNLESS
NOTED OTHERWISE.
REFER TO PARTITION TYPE SCHEDULE (ON SHEET AE501)
FOR INTERIOR WALL CONSTRUCTION.
REFER TO INTERIOR FLOOR PLANS (ON SHEETS AE420-
AE423) FOR PARTITION TYPE REFERENCE TAGS.
LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH
FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.
REFER TO PLUMBING DRAWINGS FOR ROUGH-INS.
THE MAJORITY OF EXISTING PARTITIONS ARE ROUNDED
TO 6" THICK, ALIGN EXISTING AND NEW WALL FINISHES,
TYPICAL.
1.
2.
3.
4.
5.
6.
7.
TN
N
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:0
AM
AE103
3RD FLOOR PLAN - OVERALL
FEBRUARY 2026 JME RJF
SCALE: 1/16" = 1'-0"
03 FLOOR PLAN - OVERALL1 32'8'
SCALE:1/16"=1'-0"
0 16'
I J
8.2
OFFICE/WORK
AREA
BC-106
STAIR
NO-1
DRESSING
BC-103A
WHCH TOILET
BC-105
WHCH TOILET
BC-104
STORAGE
BC-103
DEMO WALL
13' - 6"
1 11
2 2
3 7
J
K
53 SF
WHCH TOILET
BC-118
WHCH TOILET
BC-117B
KITCHEN
BC-117
154 SF
EQUIPMENT
STORAGE
BC-119
SPLINTING
BC-120
CORRECT
KINESLO
THERAPY
BC-113
OCCUPATIONAL
THERAPY
BC-116
I
CORRIDOR
CB-24
201 SF
KT EQUIP STOR
BC-111
1513 SF
CORRECT
KINESLO
THERAPY
BC-113
TELECOM
BC-114
OFFICE
BC-112
1 11
1 11
TOILET
BC-110
E
BREAK RM
BE-110
STAFF TOILET
BE-111
TOILET
BE-106
OFFICE
BE-105A
6"
1 11
SHEET NOTES - FLOOR PLAN DEMOLITION:
EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE AS-
BUILT DRAWINGS AND VISIBLE SITE SURVEY. VERIFY
EXISTING CONDITIONS PRIOR TO SUBMITTING A BID, AND
NOTIFY THE COR OF ANY DISCREPANCIES.
PROTECT ALL EXISTING WALLS, STRUCTURE, FINISHES,
AND EQUIPMENT NOT SHOWN FOR DEMOLITION WITHIN
THE AFFECTED PROJECT AREA LIMITS.
STAGING OF MATERIALS OR DEBRIS SHALL NOT RESTRICT
SAFE EXITING FROM THE BUILDING.
THE COR SHALL RESERVE THE RIGHT TO SALVAGE
MATERIALS AND/OR EQUIPMENT PRIOR TO REMOVAL OR
DEMOLITION BY CONTRACTOR.
DIMENSIONS STRINGS ASSOCIATED WITH DOOR AND
DOOR FRAME REMOVAL ONLY DEPICT THE DIMENSION OF
THE DOOR LEAF, UNLESS OTHERWISE NOTED.
ALL DIMENSIONS ARE TO FINISH FACE OF OF MATERIAL,
UNLESS OTHERWISE NOTED.
ALL DEMOLITION ITEMS SHALL BE DISPOSED BY THE
GENERAL CONTRACTOR, UNLESS OTHERWISE DIRECTED
BY THE VA COR.
SOME EXISTING WALL PARTITIONS ARE TO REMAIN AND
HAVE TILE AND BACKER BOARD REMOVED FOR
INSTALLATION OF NEW SHEATHING. REFER TO WALL
TYPES 4A AND 4B SHEET AE501 AND ENLARGED FLOOR
PLANS AE420 - AE423.
1.
2.
3.
4.
5.
6.
7.
8.
CONSTRUCTION WORK TIMES:
WEEKDAYS: MONDAY THRU FRIDAY
(START 7:00 AM AND END 4:00PM)
TIME ZONES WORK DAYS AND WORK DURATION
WEEKENDS: SATURDAY AND/OR SUNDAY
(START 8:00AM AND END 3:00PM)
WEEKDAY NIGHTIME: MON. THRU FRI.
(START 6:00PM AND END 5:00AM)
A
B
C
LEGEND: DEMOLITION
EXISTING WALL TO REMAIN
REMOVE PARTITION WALLS INCLUDING
INSULATION AND FRAMING. COORDINATE
WITH MECHANICAL AND ELECTRICAL
EXISTING SUSPENDED CEILING SYSTEM AND
ACOSUTICAL TILES AREA AFFECTED WITH
THE REMODEL, HATCH IS SHOWN FOR
ILLUSTRATION ONLY.
REMOVE EXISTING SHOWER PER
KEYNOTE #4 AND #10 ABOVE.
AREA OF EXISTING CHASE WHERE
DUMBWAITER WAS REMOVED IN A PREVIOUS
PROJECT.
KEYNOTES - FLOOR PLAN DEMOLITION:
EXISTING PARTITION TO REMAIN.
REMOVE DOOR, DOOR FRAME, AND ASSOCIATED
HARDWARE.
REMOVE EXISTING FLOORING MATERIALS, WALL BASE,
AND ADHESIVE TO BARE SUBSTRATE. SCARIFY ALL
BONDING SURFACES. PREPARE FOR LEVELING AND NEW
FLOOR FINISH.
NOT USED
REMOVE SINK, HARDWARE AND PIPING. REFER TO
PLUMBING DRAWINGS.
REMOVE WATER CLOSET, CARRIER FRAME, AND
ASSOCIATED APPURTENANCES. REFER TO PLUMBING
DRAWINGS.
REMOVE EXISTING CEILING SYSTEM, MECHANICAL
DIFFUSER AND GRILLE, ELECTRICAL FIXTURES, AND
OTHER CEILING APPURTENANCES.
NOT USED
REMOVE EXISTING HAND AND CRASH RAIL WALL
PROTECTION.
NOT USED.
REMOVE EXISTING TILE WAINSCOT, EXISTING TILE BACKER
BOARD, AND EXISTING GYPSUM BOARD ABOVE TILE.
EXISTING METAL STUDS AND/OR METAL FURRING TO
REMAIN.
EXISTING DRINKING FOUNTAIN TO REMAIN.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
X
TN
N
PROJECT NUMBER
BUILDINGS
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS
321 4 5 6 7 8 9 10
DWG. OF 56
NAME:
FULLY SPRINKLERED
CONTRACTING OFFICER'S REPRESENTATIVE
FULL SIZE DWG: 30x42
PHONE:
EMAIL:11031 S. PIKES PEAK DRIVE #202 PARKER, COLORADO 80138 PH. 303.841-3922
RENOVATE PATIENT
RESTROOMS
SALEM, VA.
100% CONSTRUCTION
DOCUMENTS
WAYNE SWITZER
540-824-5087 wayne.switzer@va.gov
2/
/2
7:
:0
AM
AD400
BASEMENT FLOOR PLANS -
ENLARGED DEMOLITION
FEBRUARY 2026 JME RJF
SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED DEMOLITION (BC-104 & BC-105)1 SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED DEMOLITION (BC-118)2
SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED DEMOLITION (BC-110)3 SCALE: 1/4" = 1'-0"
FLOOR PLAN - ENLARGED DEMOLITION (BC-111)4
4' 8'0 2'
SCALE:1/4"=1'-0"
A
A
A
A
K L M
5.3
6.7
OFFICE
1EF-118
RESIDENT OFFICE
1EF-119
MULTI PURPOSE
1EF-119A
OFFICE
1EF-120
OFFICE
1EF-120A
WAITING ROOM
CI-59
MENS TOILET
1FG-117
WOMENS TOILET
1FG-118
TOILET
1EF-122
TOILET
1EF-123
1'
1/
4"
HOUSE KEEPING
1EF-121
6'
3/
8"
4' - 1"
I
EXAM
1EF-135
EXAM
1EF-133
RECP
MALE TOILET
1EF-131
FEMALE TOILET
1EF-130
WAITING ROOM
N/A
E
6.7
F
OFFICE
1EF-154
EQUIPMENT
ROOM
1EF-155
OFFICE
1EF-158
WOMENS TOILET
1EF-156
CORRIDOR
CORRIDOR
1 11
SHEET NOTES - FLOOR PLAN DEMOLITION:
EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE AS-
BUILT DRAWINGS AND VISIBLE SITE SURVEY. VERIFY
EXISTING CONDITIONS PRIOR TO SUBMITTING A BID, AND
NOTIFY THE COR OF ANY DISCREPANCIES.
PROTECT ALL EXISTING WALLS, STRUCTURE, FINISHES,
AND EQUIPMENT NOT SHOWN FOR DEMOLITION WITHIN
THE AFFECTED PROJECT AREA LIMITS.
STAGING OF MATERIALS OR DEBRIS SHALL NOT RESTRICT
SAFE EXITING FROM THE BUILDING.
This is the start of the file's text. The full file is on GovTribe.