Attachment 6 - Exhibit D - Hardware Software and Data Processing Procedures.pdf

PDF 188 KB Posted

Attached to
PNW Alaska On-Grid Plots - Wrangell Ketchikan
Solicitation number
1240BG26Q0003
Issued by

About this file

This document specifies the hardware, software, and data processing procedures required for FIA Data Collection using the Mobile Integrated Data Acquisition System (MIDAS).

Hardware Requirements: Contractors must provide a personal computer/laptop running Microsoft Windows 10 with Java Version 8 Update 121 or later, Microsoft Office 2013, and Adobe Reader 2019 or later. For portable data recorders, contractors may furnish their own equipment if it meets specified criteria: Trimble Ranger 7 (with Government technical support), or Juniper Systems Allegro MX/Allegro 2 with minimum 128MB RAM/8GB flash storage, or Juniper Systems Allegro CE/CX with minimum 128MB RAM/512MB flash storage (without Government technical support). The Government will provide JAVAD TRIUMPH-2 (L2+GLONASS) submeter GNSS units, though contractors may furnish their own if they are identical JAVAD TRIUMPH-2 units; no other high-precision GNSS units are acceptable. Software upgrades for data editing will be provided by the Government via the MIDAS website.

Data Processing and Submission Procedures: Contractors must use Government-provided MIDAS data recorder software to enter and edit data, downloading the latest historical data files before starting each plot. All errors and critical warnings must be resolved with detailed explanations provided before uploading plots and required EPF-formatted files to the MIDAS website. Contractors must maintain current software versions by logging into the MIDAS website for updates before editing and processing. Raw files (.jps) from the JAVAD TRIUMPH-2 must be collected for each measurable, accessible subplot and transferred via MIDAS Tablet or computer using JAVAD NetView and Modem Software. All plot files must be packaged and zipped using MIDAS Plot Packager prior to loading into MIDAS Web. The Government will complete post-processing, so contractors are not responsible for purchasing JAVAD Post-processing software.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HARDWARE, SOFTWARE, AND DATA PROCESSING PROCEDURES

PORTABLE DATA RECORDER:

A PDR is required which can support the Mobile Integrated Data Acquisition System (MIDAS) for FIA Data Collection.

Should the Contractor prefer to furnish their own Portable Data Recorders, the following criteria must be met:

• Technical support by the Government: Trimble Ranger 7

• No technical support by the Government: Juniper Systems Allegro

MX/Allegro 2 minimum of 128MB RAM/8GB flash storage; Juniper Systems Allegro CE/CX minimum of 128MB RAM/512MB flash storage.

• It is anticipated over the life of this contract some changes in data editing software may be made. As such changes are required, software upgrades will be provided by the Government via the MIDAS website.

PERSONAL COMPUTER/LAPTOP:

The Contractor shall provide a personal computer with the following specifications and software:

• Microsoft Windows 10 operating system,

• Java Version 8 Update 121 or later

• Microsoft Office 2013

• Adobe Reader 2019 version or later

Installation programs for MIDAS, supporting software will be distributed via the MIDAS website. Updates to the system will be distributed through the Midas website with a username and password login for each contractor. The website will be used to retrieve plot files and to submit completed plots, including EPF files.

SUBMETER GNSS

The Government will provide JAVAD TRIUMPH-2 (L2+GLONASS) submeter GNSS unit(s) for Contractor use to collect submeter precision coordinates on all subplots based on the specifications provided by the Government. Should the Contractor prefer to furnish their own submeter GNSS unit(s), the units must be JAVAD TRIUMPH-2 (L2+GLONASS). No other high precision GNSS units are acceptable.

See the GPS Operating Guide Appendix in the Field Instructions for specific instructions on operating the units. Recordings may be collected by connecting the device to either a smart phone or Trimble Ranger 7 via bluetooth (SUBSECTION M.2.3), or by manually using TRIUMPH-2 buttons on the device (SUBSECTION M.2.4). The contractor shall collect 1 Raw file (.jps) for each measurable, accessible subplot (4 per plot), transfer the files through either MIDAS Tablet (SUBSECTION M.2.6) or to a computer using JAVAD NetView and Modem Software (SUBSECTION M.2.9), and upload the .jps file(s) via the MIDAS website

(SUBSECTION R.11.2).

Optional, if using this method: Install NetView & Modem on the computer to download .jps files, and the appropriate driver to allow the computer to communicate with the computer.

Post processing will be completed by the Government therefore the contractor is not responsible for the purchase of JAVAD Post-processing software.

DATA PROCESSING & SUBMISSION PROCEDURES:

1. Data Recorder Software (MIDAS)- The contractor shall use the Government-provided data recorder software to enter and edit the data. The Contractor shall download the latest version of historical data files from MIDAS website and EPF from BOX Drive, or a simpler method (specified by the COR) before starting the plot. The Contractor shall resolve all errors/critical warnings and provide a detailed explanation for all critical warnings before uploading the plot and its required EPF formatted files to the MIDAS website. Explanations are entered in a text box associated with each warning or critical warning in the MIDAS application.

2. Software Updates (refer to MIDAS User Guide) - The software may be updated during the field season. Contractors shall login to the MIDAS website and receive updates before editing, processing, and uploading the plots to MIDAS for completion/payment. PDRs shall be updated at these times.

3. Submeter GNSS (Appendix M) - A JAVAD TRIUMPH-2 (L2+GLONASS) will be used to collect submeter coordinates. For each subplot a raw file (.jps) must be downloaded by connecting the unit to a computer and moving each .jps file to C:\Midas\MIDASGPS\Work\pnwrs.

4. Plot Editing Tools (Appendix O)- The contractor shall use the latest MIDAS Mobile or MIDAS Control Panel software to edit each plot.

5. Loading Plot Data (Appendix O) - All files associated with each plot will be packaged and zipped via MIDAS Plot Packager prior to loading to MIDAS Web.

Completed plot data files need to be error free and present in the correct folders for the Plot Packager to zip the files together. Once all plot files have been packaged, they can be loaded into Midas Web.

PORTABLE DATA RECORDER:
PERSONAL COMPUTER/LAPTOP:
SUBMETER GNSS
DATA PROCESSING & SUBMISSION PROCEDURES:

File details come from the government source that posted it. Updated .