Attachment 5 VA Shimadzu Equipment List.xlsx
XLSX spreadsheet 24 KB Posted
- Solicitation number
- 36C26225Q0761
About this file
This document is a Request for Quote (RFQ) for Shimadzu Equipment Preventative Maintenance, Inspection, and Repair Services for the VA Greater Los Angeles Healthcare System. The solicitation (Solicitation Number: 36C26225Q0761) is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside for a firm-fixed price contract, with a base year and four one-year option periods running from 06/25/2025 to 06/24/2030. The contractor will provide comprehensive maintenance services for multiple Shimadzu laboratory equipment items located in Buildings 345 and 304, including HPLC systems, gas chromatographs, and associated software, with requirements for unlimited on-site and telephone technical support, preventive maintenance, software updates, and parts replacement.
Key performance requirements include responding to service calls within 48 hours, performing preventive maintenance and inspections as recommended by vendor specifications, providing software maintenance, and ensuring all work meets VA safety standards and manufacturer guidelines. The contract covers multiple Shimadzu instruments such as HPLC pumps, controllers, UV detectors, degassers, and autosamplers. Interested offerors must submit quotes by May 05, 2025, at 1200 PST, with evaluation based on technical experience, past performance, and cost. The contract specialist is Jennell Christofaro, and the solicitation is issued by the Department of Veterans Affairs Veterans Health Administration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
System Instrument Make model # serial # location 691 EE #
| Shimadzu HPLC for QC | HPLC pump - A | Shimadzu | LC-20AT | L20114450219 | Bldg 345, Rm166B, bench top #3 | 134695 |
| System #2 | HPLC pump - B | Shimadzu | LC-20AT | L20114350155 | Bldg 345, Rm166B, bench top #3 | 134704 |
| HPLC Controller | Shimadzu | CBM-20A | L20235053825 | Bldg 345, Rm166B, bench top #3 | N/A | |
| UV detector | Shimadzu | SPD-20A | L20134350157 | Bldg 345, Rm166B, bench top #3 | 134702 | |
| HPLC degasser | Shimadzu | DGU-20A3 | SS1-3-0200 | Bldg 345, Rm166B, bench top #3 | 134703 |
| Shimadzu HPLC for QC | HPLC pump | Shimadzu | LC-20AB | L20124650200 | Bldg 345, Rm166B, bench top #3 | 135818 |
| System #1 | HPLC controller | Shimadzu | CBM-20A | L20234651828 | Bldg 345, Rm166B, bench top #3 | |
| UV detector | Shimadzu | SPD-20A | L20134650755 | Bldg 345, Rm166B, bench top #3 | ||
| HPLC degasser | Shimadzu | DGU-20A3 | SSI-3-1114 | Bldg 345, Rm166B, bench top #3 | ||
| Autosampler | Shimadzu | SIL-20A HT | L20345256114 | Bldg 345, Rm166B, bench top #3 |
| GC for Quality Control | Gas chromatograph | Shimadzu | GC-2014AFSC | C 11484403224 | Bldg 345, Rm166B, bench top #3 | 134697 |
| GC for Quality Control | Autosampler | Shimadzu | AOC-20i | C12125202075 | Bldg 345, Rm166B, bench top #3 |
| Shimadzu HPLC Hood #3 | HPLC pump | Shimadzu | LC-20AB | L20124650193 | Bldg 345, Rm166B, hood #3 | N/A |
| UHPLC controller | Shimadzu | CBM-20A | L20234953373 | Bldg 345, Rm166B, hood #3 | 137921 | |
| UV detector | Shimadzu | SPD-10AVVP | C21003750210 | Bldg 345, Rm166B, hood #3 | 117170 | |
| HPLC degasser | Shimadzu | DGU-20A3 | SSI-3-0973 | Bldg 345, Rm166B, hood #3 | N/A |
| Shimadzu HPLC Hood #2 | HPLC pump | Shimadzu | LC-20AB | L20125050381 | Bldg 345, Rm166B, hood #2 | 147940 |
| HPLC controller | Shimadzu | CBM-20A | L20235054285 | Bldg 345, Rm166B, hood #2 | 147983 | |
| UV detector | Shimadzu | SPD-10AVP | C20993950801 | Bldg 345, Rm166B, hood #2 | 117194 | |
| HPLC degasser | Shimadzu | DGU-20A3R | L20695060630 | Bldg 345, Rm166B, hood #2 | 147984 |
| HPLC Hood #4 | HPLC pump | Shimadzu | LC-20AB | L20125050372 | Bldg 345, Rm166B, hood #4 | 154087 |
| HPLC controller | Shimadzu | CBM-20A | L20235054259 | Bldg 345, Rm166B, hood #4 | N/A | |
| UV detector | Shimadzu | SPD-20A | L20135051489 | Bldg 345, Rm166B, hood #4 | N/A | |
| HPLC degasser | Shimadzu | DGU-20A3R | L20695060501 | Bldg 345, Rm166B, hood #4 | 154087 |
| Metabolite HPLC Bldg. 304 | HPLC pump | Shimadzu | LC-20AT | L20114450381 | Bldg 304 | 117100 |
| HPLC pump | Shimadzu | LC-10ATVP | C20973851280 | Bldg 304 | 117101 | |
| HPLC degasser | Shimadzu | DGU-20A3 | SSI-3-0355 | Bldg 304 | 117376 | |
| UV detector | Shimadzu | SPD-10AVP | C20993950802 | Bldg 304 | 117195 |
| HPLC pump - A | Shimadzu | LC-10ATVP | C20974252664 | ANNEX | 117098 |
| HPLC pump - B | Shimadzu | LC-10ATVP | C20973851309 | ANNEX | 117099 |
| HPLC degasser | Shimadzu | DGU-20A3 | SSI-3-0250 | Bldg 304 | 117375 |
| Software | QC HPLC System 1 | Labsolutions | version 5.71 SP2 | 10/8/14 |
| GC | Labsolutions Lite | Version 5.52 | 3/9/12 | |
| Semi Prep | LCSolution | Version 1.25 | 7/30/09 |