Attachment 4 - MAHG151053 Repair Student Dorm Davis B6955_Drawings.pdf

PDF 9 MB Posted

Attached to
Repair Student Dorm Davis Manor
Solicitation number
FA301023R0009
Issued by

View the file

Other files

File Type Posted
Solicitation Amendment FA301023R00090002 SF 30.pdf PDF
Solicitation Amendment - FA301023R00090002.pdf PDF
Attachment 20 - Addendum 2 Repair Student Dorm Davis.pdf PDF
Attachment 19 - MNS_ECB.pdf PDF
Attachment 18 - Add Questions and Answers_Davis.pdf PDF
Attachment 17 - Addendum 1 Repair Student Dorm Davis.pdf PDF
Attachment 16 - VAV Images.pdf PDF
Attachment 15 - Questions and Answers_ Davis.pdf PDF
Solicitation Amendment - FA301023R00090001.pdf PDF
Solicitation Amendment FA301023R00090001 SF 30.pdf PDF
Pre-Bid Site Visit Sign-In 11 May 2023.pdf PDF
Attachment 2 - MAHG151053 Repair Student Dorm Davis Manor B6955_SPECS 04282023.pdf PDF
Attachment 7 - MAHG151053 Repair Student Dorm Davis Manor B6955_ MSS 05022023.xls XLS spreadsheet
Attachment 5 - MAHG151053 Repair Student Dorm Davis Manor B6955_Fire Alarm System_Drawings.pdf PDF
Attachment 11 - Past Performance Reference List.pdf PDF
Attachment 14 - Manufacturer Carpet and Adhesive Pricing.pdf PDF
Solicitation - FA301023R0009.pdf PDF
Attachment 13 - USAF Carpet Ordering Guide Jan 2022.pdf PDF
Attachment 1 - MAHG151053 Repair Student Dorm Davis Manor B6955_SOW 04282023.pdf PDF
Attachment 10 - Past Performance Questionnaire.pdf PDF
Attachment 3 - MAHG151053 Repair Student Dorm Davis Manor B6955 FA and MNS UFC 3-600-01.pdf PDF
Attachment 9 - Wage Det MS20230050_04072023.pdf PDF
Attachment 8 - MAHG151053 Repair Student Dorm Davis Manor B6955-FA MSN_MSS 05022023.xls XLS spreadsheet
Attachment 12 - Submittal Procedures.pdf PDF
Attachment 6 - Palletizing of Dorm Room Furniture (Davis).pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PARADE LN

PHANTOM ST

J.BERGERON G. REED

WILLIAMSON

WILLIAMSON 12 OCT 2022

G. REED VARIES T100

INDEX OF DRAWINGS

KEESLER AFB, MS

NOT TO SCALE

LOCATION PLAN, BLDG 7315 - SMITH MANOR

1 36MAHG15-1053

REPAIR STUDENT DORM

DAVIS MANOR

Attachment 4

FA301023R0009

AutoCAD SHX Text

REPAIR STUDENT DORM DAVIS MANOR

AutoCAD SHX Text

KEESLER AFB, MISSISSIPPI

AutoCAD SHX Text

DAVIS MANOR

AutoCAD SHX Text

MAHG15-1053

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

AIR EDUCATION AND TRAINING COMMAND

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

UNITED STATES AIR FORCE

AutoCAD SHX Text A

AutoCAD SHX Text

MISSISSIPPI

AutoCAD SHX Text

FACILITY NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

DRAWING NUMBER:

AutoCAD SHX Text

BILOXI

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text (Chief of Engineering)

AutoCAD SHX Text

SUBMITTED:

AutoCAD SHX Text (Chief of Contracts Design)

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PROJECT NUMBER:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE OF CIVIL ENGINEERS

AutoCAD SHX Text

KEESLER AIR FORCE BASE

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text N

AutoCAD SHX Text AFF ABOVE FINISH FLOOR ABOVE FINISH FLOOR ACT ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE BD BOARD BOARD CONC. CONCRETE CONCRETE CONT CONTINUOUS CONTINUOUS CPT CARPET CARPET CT CERAMIC TILE CERAMIC TILE ELECT ELECTRIC ELECTRIC GWB GYPSUM WALL BOARD GYPSUM WALL BOARD GYP GYPSUM GYPSUM HORZ HORIZONTAL HORIZONTAL HVAC HEATING VENTING AIR CONDITIONING HEATING VENTING AIR CONDITIONING MAX MAXIMUM MAXIMUM MECH MECHANICAL MECHANICAL MIN MINIMUM MINIMUM MLWK MILLWORK MILLWORK OC ON CENTER ON CENTER PLAM PLASTIC LAMINATE PLASTIC LAMINATE PLUM PLUMBING PLUMBING PLYWD PLYWOOD PLYWOOD PNT PAINTED PAINTED PT PORCELAIN TILE PORCELAIN TILE TYP TYPICAL TYPICAL VCT VINYL COMPOSITION TILE VINYL COMPOSITION TILE VNYL VINYL VINYL VERT VERTICAL VERTICAL W/ WITH WITH WD WOOD WOOD

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

BUILDING 6955

AutoCAD SHX Text ARCHITECTURAL SHEETS SHEETS SHEETS T100 TITLE SHEET 1 OF 36 TITLE SHEET 1 OF 36 1 OF 36 A100 FIRST FLOOR COMMONS PLAN 2 OF 36 FIRST FLOOR COMMONS PLAN 2 OF 36 2 OF 36 A101 SECOND FLOOR COMMONS PLAN 3 OF 36 SECOND FLOOR COMMONS PLAN 3 OF 36 3 OF 36 A102 THIRD FLOOR COMMONS PLAN 4 OF 36 THIRD FLOOR COMMONS PLAN 4 OF 36 4 OF 36 A103 FIRST FLOOR/RCP A WING 5 OF 36 FIRST FLOOR/RCP A WING 5 OF 36 5 OF 36 A104 SECOND FLOOR/RCP A WING 6 OF 36 SECOND FLOOR/RCP A WING 6 OF 36 6 OF 36 A105 THIRD FLOOR/RCP A WING 7 OF 36 THIRD FLOOR/RCP A WING 7 OF 36 7 OF 36 A106 FIRST FLOOR/RCP B WING 8 OF 36 FIRST FLOOR/RCP B WING 8 OF 36 8 OF 36 A107 SECOND FLOOR/RCP B WING 9 OF 36 SECOND FLOOR/RCP B WING 9 OF 36 9 OF 36 A108 THIRD FLOOR/RCP B WING 10 OF 36 THIRD FLOOR/RCP B WING 10 OF 36 10 OF 36 A109 FIRST FLOOR/RCP C WING 11 OF 36 FIRST FLOOR/RCP C WING 11 OF 36 11 OF 36 A110 SECOND FLOOR/RCP C WING 12 OF 36 SECOND FLOOR/RCP C WING 12 OF 36 12 OF 36 A111 THIRD FLOOR/RCP C WING 13 OF 36 THIRD FLOOR/RCP C WING 13 OF 36 13 OF 36 A112 TYPICAL ROOM 14 OF 36 TYPICAL ROOM 14 OF 36 14 OF 36 A300 MILLWORK PLANS, ELEVATIONS AND DETAILS 15 OF 36 MILLWORK PLANS, ELEVATIONS AND DETAILS 15 OF 36 15 OF 36 A400 LIGHTING PLAN, SHOWER SECTIONS, DETAILS & LEGENDS 16 OF 36 LIGHTING PLAN, SHOWER SECTIONS, DETAILS & LEGENDS 16 OF 36 16 OF 36 A500 COMMONS AREA RCP REFERENCE 17 OF 36 COMMONS AREA RCP REFERENCE 17 OF 36 17 OF 36 MECHANICAL SHEETS SHEETS SHEETS M001 SCHEDULES, DETAILS 18 OF 36 SCHEDULES, DETAILS 18 OF 36 18 OF 36 M002 MECHANICAL DETAILS 19 OF 36 MECHANICAL DETAILS 19 OF 36 19 OF 36 M100 1ST FLR MECHANICAL PLAN CENTRAL CORE 20 OF 36 1ST FLR MECHANICAL PLAN CENTRAL CORE 20 OF 36 20 OF 36 M101 1ST FLR MECHANICAL PLAN WEST WING (A-WING) 21 OF 36 1ST FLR MECHANICAL PLAN WEST WING (A-WING) 21 OF 36 21 OF 36 M102 1ST FLR MECHANICAL PLAN EAST WING (B-WING) 22 OF 36 1ST FLR MECHANICAL PLAN EAST WING (B-WING) 22 OF 36 22 OF 36 M103 1ST FLR MECHANICAL PLAN SOUTH WING (C-WING) 23 OF 36 1ST FLR MECHANICAL PLAN SOUTH WING (C-WING) 23 OF 36 23 OF 36 M200 2ND FLR MECHANICAL PLAN CENTRAL CORE 24 OF 36 2ND FLR MECHANICAL PLAN CENTRAL CORE 24 OF 36 24 OF 36 M201 2ND FLR MECHANICAL PLAN WEST WING (A-WING) 25 OF 36 2ND FLR MECHANICAL PLAN WEST WING (A-WING) 25 OF 36 25 OF 36 M202 2ND FLR MECHANICAL PLAN EAST WING (B-WING) 26 OF 36 2ND FLR MECHANICAL PLAN EAST WING (B-WING) 26 OF 36 26 OF 36 M203 2ND FLR MECHANICAL PLAN SOUTH WING (C-WING) 27 OF 36 2ND FLR MECHANICAL PLAN SOUTH WING (C-WING) 27 OF 36 27 OF 36 M300 3RD FLR MECHANICAL PLAN CENTRAL CORE 28 OF 36 3RD FLR MECHANICAL PLAN CENTRAL CORE 28 OF 36 28 OF 36 M301 3RD FLR MECHANICAL PLAN WEST WING (A-WING) 29 OF 36 3RD FLR MECHANICAL PLAN WEST WING (A-WING) 29 OF 36 29 OF 36 M302 3RD FLR MECHANICAL PLAN EAST WING (B-WING) 30 OF 36 3RD FLR MECHANICAL PLAN EAST WING (B-WING) 30 OF 36 30 OF 36 M303 3RD FLR MECHANICAL PLAN SOUTH WING (C-WING) 31 OF 36 3RD FLR MECHANICAL PLAN SOUTH WING (C-WING) 31 OF 36 31 OF 36 M400 ATTIC MECHANICAL PLAN-CENTRAL CORE 32 OF 36 ATTIC MECHANICAL PLAN-CENTRAL CORE 32 OF 36 32 OF 36 M401 ATTIC MECHANICAL PLAN-WEST WING (A-WING) 33 OF 36 ATTIC MECHANICAL PLAN-WEST WING (A-WING) 33 OF 36 33 OF 36 M402 ATTIC MECHANICAL PLAN-EAST WING (B-WING) 34 OF 36 ATTIC MECHANICAL PLAN-EAST WING (B-WING) 34 OF 36 34 OF 36 M403 ATTIC MECHANICAL PLAN-SOUTH WING (C-WING) 35 OF 36 ATTIC MECHANICAL PLAN-SOUTH WING (C-WING) 35 OF 36 35 OF 36 M600 VAV CONTROL SCHEMATIC 36 OF 36VAV CONTROL SCHEMATIC 36 OF 3636 OF 36

J.BERGERON G. REED

G. REED VARIES A100

2 36

WILLIAMSON

WILLIAMSON 12 OCT 2022

REPAIR STUDENT DORM

DAVIS MANOR

MAHG15-1053

AutoCAD SHX Text

FIRST FLOOR PLAN

AutoCAD SHX Text

SCALE 1/8"= 1'-0"

AutoCAD SHX Text

COMMONS

AutoCAD SHX Text

BRIEFING

AutoCAD SHX Text

MEN

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

VENDING

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

HSKPG

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text N

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text D118

AutoCAD SHX Text A116

AutoCAD SHX Text D117

AutoCAD SHX Text D123

AutoCAD SHX Text D116

AutoCAD SHX Text D121

AutoCAD SHX Text D120

AutoCAD SHX Text A117

AutoCAD SHX Text D118

AutoCAD SHX Text D132

AutoCAD SHX Text D131

AutoCAD SHX Text D133

AutoCAD SHX Text B117

AutoCAD SHX Text B116

AutoCAD SHX Text D104

AutoCAD SHX Text D103

AutoCAD SHX Text D106

AutoCAD SHX Text D108

AutoCAD SHX Text D107

AutoCAD SHX Text D111

AutoCAD SHX Text D112

AutoCAD SHX Text D113

AutoCAD SHX Text D114

AutoCAD SHX Text D115

AutoCAD SHX Text D127

AutoCAD SHX Text D125

AutoCAD SHX Text C133

AutoCAD SHX Text C132

AutoCAD SHX Text D101

AutoCAD SHX Text D100

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE C-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE A-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE B-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOTE 1: EXISTING PLAN INDICATING DEMOLITION AND RENOVATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

NOTE 2: SEE DOOR AND FRAME SCHEDULE SHEET A112 FOR DOORS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text A2

AutoCAD SHX Text B

AutoCAD SHX Text 23.1

AutoCAD SHX Text 23.1

AutoCAD SHX Text 23.1

AutoCAD SHX Text 23.1

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYPICAL COMMON AREA KEYED NOTES

AutoCAD SHX Text REMOVE CARPET AND BASE. REPLACE WITH NEW CARPET TILE AND RUBBER BASE. REPAIR DAMAGED GYPSUM WALL BOARD BACKING (IF NECESSARY) BEFORE INSTALLING BASE. REMOVE BASE. REPLACE WITH COVE TILE BASE TO MATCH EXISTING FLOOR TILE. REPAIR ANY DAMAGED GYPSUM WALL BOARD BACKING BEFORE APPLYING TILE BASE. ASSUME10% REPLACEMENT. REMOVE RUBBER FLOORING & RUBBER BASE. PROVIDE NEW RUBBER FLOORING & 6" RUBBER BASE IN STAIRWELLS AND VESTIBULES. REPAIR ANY DAMAGED WALL BEFORE APPLYING NEW BASE. REMOVE VINYL SHEET FLOORING AND BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. REMOVE VCT FLOORING AND RUBBER BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. PAINT WALLS. REMOVE VINYL WALL COVERING & REFINISH WALL OR REPLACE GYPSUM WALL BOARD AS NECESSARY TO ACHIEVE LEVEL 4 FINISH. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. PAINT ACCORDING TO SPECIFICATIONS. REMOVE AND REPLACE FLOORING IN ELEVATOR. REMOVE & REPLACE MILLWORK. REMOVE & REPLACE LAMINATE IN LAUNDRY ROOMS. SEE MILLWORK DETAILS (A300). REMOVE MILLWORK. SECURE TOILET PARTITIONS. REMOVE AND REPLACE TOILET PAPER DISPENSERS AND SOAP DISPENSERS. REMOVE AND PROVIDE NEW COUNTERTOP AND SINKS. REPLACE 4'X6' RECESSED MAT. MATCH EXISTING DEPTH TO PREVENT TRIP HAZARD. ALUMINUM LINKAGE WITH RUBBER TREAD STRIPS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. REPAIR PEELING WALL FINISH IN STAIRWELLS. PRIME AND PAINT STAIRWELL WALLS AND HANDRAIL. STRIP, CLEAN STAIR NOSING AND CONCRETE. RESEAL/PAINT CONCRETE. REMOVE AND PROVIDE NEW RUBBER FLOORING AT LANDINGS WITH NEW RUBBER BASE. REMOVE AND PROVIDE NEW 32"x32"x6" MOP SINK. COORDINATED WITH EXISTING DRAIN LOCATION. REMOVE AND PROVIDE NEW FAUCET, AND (2) HEAVY DUTY MOP HOLDERS. PROVIDE NEW STAINLESS STEEL MOP SINK SURROUND/BACKSPLASH TO MIN. HEIGHT OF 36" ABOVE SINK TOP. REMOVE AND PROVIDE NEW CORK BOARD BACKING/LINING IN EXISTING DISPLAY CASES. REMOVE AND REPLACE EXISTING DISPLAY CASE WITH NEW WALL MOUNTED 4'X5' HEAVY DUTY LOCKABLE DISPLAY CASE. ALUMINUM FRAME WITH CORK BOARD BACKING. COLOR TO MATCH EXISTING DISPLAY CASES. REMOVE AND REPLACE ELECTRICAL OUTLET AND SWITCH FACEPLATES WITH HEAVY DUTY METAL FACEPLATES. STRIP, CLEAN, & SEAL ALL TILE AND GROUT. REFINISH DOOR TO MATCH EXISTING COLOR AND FINISH. REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS (2/A112). PROVIDE 4' TALL HEAVY DUTY CORNER GUARDS @ ALL OUTSIDE CORNERS. MURALS TO REMAIN-DO NOT PAINT OVER ALL MURALS..

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS.)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 23.1

AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS DESIGNED. 2. PROTECT ALL FIRE ALARM COMPONENTS, CEILING GRID, FIRE EXTINGUISHER CABINETS, SPRINKLER HEADS, HVAC GRILLS, AND OTHER EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION DEBRIS DURING CONSTRUCTION. CONTRACTOR WILL REPLACE OR CLEAN IN PLACE ANY DAMAGED OR CONTAMINATED ITEMS. 3. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE SCOPE OF WORK AND SCHEDULE. WORK SHALL BE COMPLETED IN ONE SECTION BEFORE MOVING ON TO THE NEXT SECTION. 4. CONTRACTING OFFICER TO SELECT PAINT COLOR AND SHEEN FROM MANUFACTURER'S STANDARD COLORS FOR ALL SURFACES TO BE PAINTED. WALLS, CEILINGS, HANDRAILS, DOOR FRAMES TO BE PAINTED IN ROOMS BEING WORKED IN. DOORS TO BE PAINTED AS CALLED FOR. 5. REPLACE CEILING TILES SUPPORTING EXIT SIGNAGE WITH " WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 34" WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 6. REMOVE AND DISPOSE OF ALL NAILS, BRACKETS, AND OTHER UNUSED ITEMS FROM WALL BEFORE PATCHING AND PAINTING. 7. REPLACE ANY MISSING OR DAMAGED ELECTRICAL FACE PLATES IN DORM ROOMS- MATCH EXISTING. REPLACE COMMON AREA FACEPLATES AS NOTED. 8. REMOVE SEALANT FROM ALL WINDOWS AND PREPARE FOR NEW SEALANT. APPLY NEW SEALANT IN A PROFESSIONAL WORKMAN LIKE MANNER.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

AIR EDUCATION AND TRAINING COMMAND

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

UNITED STATES AIR FORCE

AutoCAD SHX Text A

AutoCAD SHX Text

MISSISSIPPI

AutoCAD SHX Text

FACILITY NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

DRAWING NUMBER:

AutoCAD SHX Text

BILOXI

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text (Chief of Engineering)

AutoCAD SHX Text

SUBMITTED:

AutoCAD SHX Text (Chief of Contracts Design)

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PROJECT NUMBER:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE OF CIVIL ENGINEERS

AutoCAD SHX Text

KEESLER AIR FORCE BASE

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

B-WING

AutoCAD SHX Text

A-WING

AutoCAD SHX Text

COMMONS

AutoCAD SHX Text

C-WING

FIRST FLOOR

G. REED VARIES A101

3 36

WILLIAMSON

12 OCT 2022WILLIAMSON

REPAIR STUDENT DORM

DAVIS MANOR

MAHG15-1053

AutoCAD SHX Text

SECOND FLOOR PLAN

AutoCAD SHX Text

SCALE 1/8"= 1'-0"

AutoCAD SHX Text

COMMONS

AutoCAD SHX Text

DN

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

DATA/COMP

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

VENDING

AutoCAD SHX Text

LOUNGE

AutoCAD SHX Text

LOUNGE

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

HSKPG

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text N

AutoCAD SHX Text

COMMONS AREA

AutoCAD SHX Text A218

AutoCAD SHX Text A217

AutoCAD SHX Text B216

AutoCAD SHX Text B217

AutoCAD SHX Text D214

AutoCAD SHX Text D213

AutoCAD SHX Text D212

AutoCAD SHX Text D210

AutoCAD SHX Text D211

AutoCAD SHX Text D205

AutoCAD SHX Text D206

AutoCAD SHX Text D204

AutoCAD SHX Text D203

AutoCAD SHX Text D201

AutoCAD SHX Text D219

AutoCAD SHX Text D218

AutoCAD SHX Text D216

AutoCAD SHX Text D209

AutoCAD SHX Text D207

AutoCAD SHX Text C232

AutoCAD SHX Text C230

AutoCAD SHX Text C231

AutoCAD SHX Text C233

AutoCAD SHX Text D200

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text A2

AutoCAD SHX Text A2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE A-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A2

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE B-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text A2

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE C-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CHASE

AutoCAD SHX Text

NOTE 1: EXISTING PLAN INDICATING DEMOLITION AND RENOVATION

AutoCAD SHX Text

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOTE 2: SEE DOOR AND FRAME SCHEDULE SHEET A112 FOR DOORS

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text A2

AutoCAD SHX Text B

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text 23.1

AutoCAD SHX Text 23.1

AutoCAD SHX Text

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS DESIGNED. 2. PROTECT ALL FIRE ALARM COMPONENTS, CEILING GRID, FIRE EXTINGUISHER CABINETS, SPRINKLER HEADS, HVAC GRILLS, AND OTHER EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION DEBRIS DURING CONSTRUCTION. CONTRACTOR WILL REPLACE OR CLEAN IN PLACE ANY DAMAGED OR CONTAMINATED ITEMS. 3. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE SCOPE OF WORK AND SCHEDULE. WORK SHALL BE COMPLETED IN ONE SECTION BEFORE MOVING ON TO THE NEXT SECTION. 4. CONTRACTING OFFICER TO SELECT PAINT COLOR AND SHEEN FROM MANUFACTURER'S STANDARD COLORS FOR ALL SURFACES TO BE PAINTED. WALLS, CEILINGS, HANDRAILS, DOOR FRAMES TO BE PAINTED IN ROOMS BEING WORKED IN. DOORS TO BE PAINTED AS CALLED FOR. 5. REPLACE CEILING TILES SUPPORTING EXIT SIGNAGE WITH " WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 34" WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 6. REMOVE AND DISPOSE OF ALL NAILS, BRACKETS, AND OTHER UNUSED ITEMS FROM WALL BEFORE PATCHING AND PAINTING. 7. REPLACE ANY MISSING OR DAMAGED ELECTRICAL FACE PLATES IN DORM ROOMS- MATCH EXISTING. REPLACE COMMON AREA FACEPLATES AS NOTED. 8. REMOVE SEALANT FROM ALL WINDOWS AND PREPARE FOR NEW SEALANT. APPLY NEW SEALANT IN A PROFESSIONAL WORKMAN LIKE MANNER.

AutoCAD SHX Text

TYPICAL COMMON AREA KEYED NOTES

AutoCAD SHX Text REMOVE CARPET AND BASE. REPLACE WITH NEW CARPET TILE AND RUBBER BASE. REPAIR DAMAGED GYPSUM WALL BOARD BACKING (IF NECESSARY) BEFORE INSTALLING BASE. REMOVE BASE. REPLACE WITH COVE TILE BASE TO MATCH EXISTING FLOOR TILE. REPAIR ANY DAMAGED GYPSUM WALL BOARD BACKING BEFORE APPLYING TILE BASE. ASSUME10% REPLACEMENT. REMOVE RUBBER FLOORING & RUBBER BASE. PROVIDE NEW RUBBER FLOORING & 6" RUBBER BASE IN STAIRWELLS AND VESTIBULES. REPAIR ANY DAMAGED WALL BEFORE APPLYING NEW BASE. REMOVE VINYL SHEET FLOORING AND BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. REMOVE VCT FLOORING AND RUBBER BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. PAINT WALLS. REMOVE VINYL WALL COVERING & REFINISH WALL OR REPLACE GYPSUM WALL BOARD AS NECESSARY TO ACHIEVE LEVEL 4 FINISH. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. PAINT ACCORDING TO SPECIFICATIONS. REMOVE AND REPLACE FLOORING IN ELEVATOR. REMOVE & REPLACE MILLWORK. REMOVE & REPLACE LAMINATE IN LAUNDRY ROOMS. SEE MILLWORK DETAILS (A300). REMOVE MILLWORK. SECURE TOILET PARTITIONS. REMOVE AND REPLACE TOILET PAPER DISPENSERS AND SOAP DISPENSERS. REMOVE AND PROVIDE NEW COUNTERTOP AND SINKS. REPLACE 4'X6' RECESSED MAT. MATCH EXISTING DEPTH TO PREVENT TRIP HAZARD. ALUMINUM LINKAGE WITH RUBBER TREAD STRIPS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. REPAIR PEELING WALL FINISH IN STAIRWELLS. PRIME AND PAINT STAIRWELL WALLS AND HANDRAIL. STRIP, CLEAN STAIR NOSING AND CONCRETE. RESEAL/PAINT CONCRETE. REMOVE AND PROVIDE NEW RUBBER FLOORING AT LANDINGS WITH NEW RUBBER BASE. REMOVE AND PROVIDE NEW 32"x32"x6" MOP SINK. COORDINATED WITH EXISTING DRAIN LOCATION. REMOVE AND PROVIDE NEW FAUCET, AND (2) HEAVY DUTY MOP HOLDERS. PROVIDE NEW STAINLESS STEEL MOP SINK SURROUND/BACKSPLASH TO MIN. HEIGHT OF 36" ABOVE SINK TOP. REMOVE AND PROVIDE NEW CORK BOARD BACKING/LINING IN EXISTING DISPLAY CASES. REMOVE AND REPLACE EXISTING DISPLAY CASE WITH NEW WALL MOUNTED 4'X5' HEAVY DUTY LOCKABLE DISPLAY CASE. ALUMINUM FRAME WITH CORK BOARD BACKING. COLOR TO MATCH EXISTING DISPLAY CASES. REMOVE AND REPLACE ELECTRICAL OUTLET AND SWITCH FACEPLATES WITH HEAVY DUTY METAL FACEPLATES. STRIP, CLEAN, & SEAL ALL TILE AND GROUT. REFINISH DOOR TO MATCH EXISTING COLOR AND FINISH. REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS (2/A112). PROVIDE 4' TALL HEAVY DUTY CORNER GUARDS @ ALL OUTSIDE CORNERS. MURALS TO REMAIN-DO NOT PAINT OVER ALL MURALS..

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS.)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 23.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

AIR EDUCATION AND TRAINING COMMAND

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

UNITED STATES AIR FORCE

AutoCAD SHX Text A

AutoCAD SHX Text

MISSISSIPPI

AutoCAD SHX Text

FACILITY NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

DRAWING NUMBER:

AutoCAD SHX Text

BILOXI

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text (Chief of Engineering)

AutoCAD SHX Text

SUBMITTED:

AutoCAD SHX Text (Chief of Contracts Design)

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PROJECT NUMBER:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE OF CIVIL ENGINEERS

AutoCAD SHX Text

KEESLER AIR FORCE BASE

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

B-WING

AutoCAD SHX Text

A-WING

AutoCAD SHX Text

COMMONS

AutoCAD SHX Text

C-WING

SECOND FLOOR

G. REED VARIES A102

4 36

WILLIAMSON

WILLIAMSON 12 OCT 2022

REPAIR STUDENT DORM

DAVIS MANOR

MAHG15-1053

AutoCAD SHX Text

THIRD FLOOR PLAN

AutoCAD SHX Text

SCALE 1/8"= 1'-0"

AutoCAD SHX Text

COMMONS

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

VENDING

AutoCAD SHX Text

LOUNGE

AutoCAD SHX Text

LOUNGE

AutoCAD SHX Text

HSKPG

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

DATA/COMP

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text N

AutoCAD SHX Text

COMMONS AREA

AutoCAD SHX Text D300

AutoCAD SHX Text

TYP ROOM

AutoCAD SHX Text D305

AutoCAD SHX Text D311

AutoCAD SHX Text D306

AutoCAD SHX Text D304

AutoCAD SHX Text D303

AutoCAD SHX Text D318

AutoCAD SHX Text D301

AutoCAD SHX Text D312

AutoCAD SHX Text D313

AutoCAD SHX Text D314

AutoCAD SHX Text D319

AutoCAD SHX Text D316

AutoCAD SHX Text D309

AutoCAD SHX Text D307

AutoCAD SHX Text D310

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CHASE

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOTE 1: EXISTING PLAN INDICATING DEMOLITION AND RENOVATION

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text D232

AutoCAD SHX Text D230

AutoCAD SHX Text D231

AutoCAD SHX Text D233

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE C-WING FLOOR PLANS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOTE 2: SEE DOOR AND FRAME SCHEDULE SHEET A112 FOR DOORS

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text A2

AutoCAD SHX Text B

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

(NO WORK)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 23.1

AutoCAD SHX Text

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS DESIGNED. 2. PROTECT ALL FIRE ALARM COMPONENTS, CEILING GRID, FIRE EXTINGUISHER CABINETS, SPRINKLER HEADS, HVAC GRILLS, AND OTHER EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION DEBRIS DURING CONSTRUCTION. CONTRACTOR WILL REPLACE OR CLEAN IN PLACE ANY DAMAGED OR CONTAMINATED ITEMS. 3. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE SCOPE OF WORK AND SCHEDULE. WORK SHALL BE COMPLETED IN ONE SECTION BEFORE MOVING ON TO THE NEXT SECTION. 4. CONTRACTING OFFICER TO SELECT PAINT COLOR AND SHEEN FROM MANUFACTURER'S STANDARD COLORS FOR ALL SURFACES TO BE PAINTED. WALLS, CEILINGS, HANDRAILS, DOOR FRAMES TO BE PAINTED IN ROOMS BEING WORKED IN. DOORS TO BE PAINTED AS CALLED FOR. 5. REPLACE CEILING TILES SUPPORTING EXIT SIGNAGE WITH " WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 34" WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 6. REMOVE AND DISPOSE OF ALL NAILS, BRACKETS, AND OTHER UNUSED ITEMS FROM WALL BEFORE PATCHING AND PAINTING. 7. REPLACE ANY MISSING OR DAMAGED ELECTRICAL FACE PLATES IN DORM ROOMS- MATCH EXISTING. REPLACE COMMON AREA FACEPLATES AS NOTED. 8. REMOVE SEALANT FROM ALL WINDOWS AND PREPARE FOR NEW SEALANT. APPLY NEW SEALANT IN A PROFESSIONAL WORKMAN LIKE MANNER.

AutoCAD SHX Text

TYPICAL COMMON AREA KEYED NOTES

AutoCAD SHX Text REMOVE CARPET AND BASE. REPLACE WITH NEW CARPET TILE AND RUBBER BASE. REPAIR DAMAGED GYPSUM WALL BOARD BACKING (IF NECESSARY) BEFORE INSTALLING BASE. REMOVE BASE. REPLACE WITH COVE TILE BASE TO MATCH EXISTING FLOOR TILE. REPAIR ANY DAMAGED GYPSUM WALL BOARD BACKING BEFORE APPLYING TILE BASE. ASSUME10% REPLACEMENT. REMOVE RUBBER FLOORING & RUBBER BASE. PROVIDE NEW RUBBER FLOORING & 6" RUBBER BASE IN STAIRWELLS AND VESTIBULES. REPAIR ANY DAMAGED WALL BEFORE APPLYING NEW BASE. REMOVE VINYL SHEET FLOORING AND BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. REMOVE VCT FLOORING AND RUBBER BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. PAINT WALLS. REMOVE VINYL WALL COVERING & REFINISH WALL OR REPLACE GYPSUM WALL BOARD AS NECESSARY TO ACHIEVE LEVEL 4 FINISH. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. PAINT ACCORDING TO SPECIFICATIONS. REMOVE AND REPLACE FLOORING IN ELEVATOR. REMOVE & REPLACE MILLWORK. REMOVE & REPLACE LAMINATE IN LAUNDRY ROOMS. SEE MILLWORK DETAILS (A300). REMOVE MILLWORK. SECURE TOILET PARTITIONS. REMOVE AND REPLACE TOILET PAPER DISPENSERS AND SOAP DISPENSERS. REMOVE AND PROVIDE NEW COUNTERTOP AND SINKS. REPLACE 4'X6' RECESSED MAT. MATCH EXISTING DEPTH TO PREVENT TRIP HAZARD. ALUMINUM LINKAGE WITH RUBBER TREAD STRIPS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. REPAIR PEELING WALL FINISH IN STAIRWELLS. PRIME AND PAINT STAIRWELL WALLS AND HANDRAIL. STRIP, CLEAN STAIR NOSING AND CONCRETE. RESEAL/PAINT CONCRETE. REMOVE AND PROVIDE NEW RUBBER FLOORING AT LANDINGS WITH NEW RUBBER BASE. REMOVE AND PROVIDE NEW 32"x32"x6" MOP SINK. COORDINATED WITH EXISTING DRAIN LOCATION. REMOVE AND PROVIDE NEW FAUCET, AND (2) HEAVY DUTY MOP HOLDERS. PROVIDE NEW STAINLESS STEEL MOP SINK SURROUND/BACKSPLASH TO MIN. HEIGHT OF 36" ABOVE SINK TOP. REMOVE AND PROVIDE NEW CORK BOARD BACKING/LINING IN EXISTING DISPLAY CASES. REMOVE AND REPLACE EXISTING DISPLAY CASE WITH NEW WALL MOUNTED 4'X5' HEAVY DUTY LOCKABLE DISPLAY CASE. ALUMINUM FRAME WITH CORK BOARD BACKING. COLOR TO MATCH EXISTING DISPLAY CASES. REMOVE AND REPLACE ELECTRICAL OUTLET AND SWITCH FACEPLATES WITH HEAVY DUTY METAL FACEPLATES. STRIP, CLEAN, & SEAL ALL TILE AND GROUT. REFINISH DOOR TO MATCH EXISTING COLOR AND FINISH. REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS (2/A112). PROVIDE 4' TALL HEAVY DUTY CORNER GUARDS @ ALL OUTSIDE CORNERS. MURALS TO REMAIN-DO NOT PAINT OVER ALL MURALS..

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS.)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 23.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

AIR EDUCATION AND TRAINING COMMAND

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

UNITED STATES AIR FORCE

AutoCAD SHX Text A

AutoCAD SHX Text

MISSISSIPPI

AutoCAD SHX Text

FACILITY NUMBER:

AutoCAD SHX Text

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

DRAWING NUMBER:

AutoCAD SHX Text

BILOXI

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text (Chief of Engineering)

AutoCAD SHX Text

SUBMITTED:

AutoCAD SHX Text (Chief of Contracts Design)

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

PROJECT NUMBER:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE OF CIVIL ENGINEERS

AutoCAD SHX Text

KEESLER AIR FORCE BASE

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

B-WING

AutoCAD SHX Text

A-WING

AutoCAD SHX Text

COMMONS

AutoCAD SHX Text

C-WING

THIRD FLOOR

G. REED VARIES A103

5 36

WILLIAMSON

WILLIAMSON 12 OCT 2022

REPAIR STUDENT DORM

DAVIS MANOR

MAHG15-1053

AutoCAD SHX Text

FIRST FLOOR PLAN

AutoCAD SHX Text

SCALE 1/8"= 1'-0"

AutoCAD SHX Text

REFLECTED CEILING PLAN

AutoCAD SHX Text

SCALE 1/8"= 1'-0"

AutoCAD SHX Text

A-WING

AutoCAD SHX Text

FIRST FLOOR

AutoCAD SHX Text

A-WING

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

UP

AutoCAD SHX Text

STAIRS

AutoCAD SHX Text

UP

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text A103

AutoCAD SHX Text A101

AutoCAD SHX Text A100

AutoCAD SHX Text A102

AutoCAD SHX Text A105

AutoCAD SHX Text A104

AutoCAD SHX Text A106

AutoCAD SHX Text A108

AutoCAD SHX Text A110

AutoCAD SHX Text A112

AutoCAD SHX Text A114

AutoCAD SHX Text A116

AutoCAD SHX Text A118

AutoCAD SHX Text A120

AutoCAD SHX Text A121

AutoCAD SHX Text A119

AutoCAD SHX Text A117

AutoCAD SHX Text A115

AutoCAD SHX Text A113

AutoCAD SHX Text A111

AutoCAD SHX Text A109

AutoCAD SHX Text A107

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text

TYP. ROOM

AutoCAD SHX Text A103

AutoCAD SHX Text A101

AutoCAD SHX Text A100

AutoCAD SHX Text A102

AutoCAD SHX Text A105

AutoCAD SHX Text A104

AutoCAD SHX Text A106

AutoCAD SHX Text A108

AutoCAD SHX Text A110

AutoCAD SHX Text A112

AutoCAD SHX Text A114

AutoCAD SHX Text A116

AutoCAD SHX Text A118

AutoCAD SHX Text A120

AutoCAD SHX Text A121

AutoCAD SHX Text A119

AutoCAD SHX Text A117

AutoCAD SHX Text A115

AutoCAD SHX Text A113

AutoCAD SHX Text A111

AutoCAD SHX Text A109

AutoCAD SHX Text A107

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text A118

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

CHASE

AutoCAD SHX Text

CHASE

AutoCAD SHX Text

NOTE: EXISTING PLAN INDICATING DEMOLITION AND RENOVATION

AutoCAD SHX Text

NOTE: EXISTING PLAN INDICATING DEMOLITION AND RENOVATION

AutoCAD SHX Text

CORRIDOR AREA RCP FOR REFERENCE ONLY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS DESIGNED. 2. PROTECT ALL FIRE ALARM COMPONENTS, CEILING GRID, FIRE EXTINGUISHER CABINETS, SPRINKLER HEADS, HVAC GRILLS, AND OTHER EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION DEBRIS DURING CONSTRUCTION. CONTRACTOR WILL REPLACE OR CLEAN IN PLACE ANY DAMAGED OR CONTAMINATED ITEMS. 3. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE SCOPE OF WORK AND SCHEDULE. WORK SHALL BE COMPLETED IN ONE SECTION BEFORE MOVING ON TO THE NEXT SECTION. 4. CONTRACTING OFFICER TO SELECT PAINT COLOR AND SHEEN FROM MANUFACTURER'S STANDARD COLORS FOR ALL SURFACES TO BE PAINTED. WALLS, CEILINGS, HANDRAILS, DOOR FRAMES TO BE PAINTED IN ROOMS BEING WORKED IN. DOORS TO BE PAINTED AS CALLED FOR. 5. REPLACE CEILING TILES SUPPORTING EXIT SIGNAGE WITH " WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 34" WHITE MELAMINE FACED PANELING. FASTEN "EXIT" SIGNAGE TO MELAMINE PANEL. 6. REMOVE AND DISPOSE OF ALL NAILS, BRACKETS, AND OTHER UNUSED ITEMS FROM WALL BEFORE PATCHING AND PAINTING. 7. REPLACE ANY MISSING OR DAMAGED ELECTRICAL FACE PLATES IN DORM ROOMS- MATCH EXISTING. REPLACE COMMON AREA FACEPLATES AS NOTED. 8. REMOVE SEALANT FROM ALL WINDOWS AND PREPARE FOR NEW SEALANT. APPLY NEW SEALANT IN A PROFESSIONAL WORKMAN LIKE MANNER.

AutoCAD SHX Text REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS (1/A112). PROVIDE 4' TALL HEAVY DUTY CORNER GUARDS. REMOVE EXISTING RUBBER BASE. REPAIR DAMAGED GYPSUM WALLBOARD BACKER AS REQUIRED. REPLACE WITH MATCHING CERMAIC TILE BASE AND GROUT. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, SPLITS AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. REPLACE DORM ROOM SIGNAGE. MATCH EXISTING ROOM SIGNAGE. STRIP, CLEAN, & SEAL TILE FLOORS AND GROUT.

AutoCAD SHX Text

TYPICAL DORM WING HALL KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

SPEAKER

AutoCAD SHX Text

SMOKE DETECTOR

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

MECHANICAL DIFFUSERS

AutoCAD SHX Text

RECESSED INCANDESCENT FIXTURE

AutoCAD SHX Text

FLUORESCENT FIXTURE

AutoCAD SHX Text REMOVE CARPET AND BASE. REPLACE WITH NEW CARPET TILE AND RUBBER BASE. REPAIR DAMAGED GYPSUM WALL BOARD BACKING (IF NECESSARY) BEFORE INSTALLING BASE. REMOVE BASE. REPLACE WITH COVE TILE BASE TO MATCH EXISTING FLOOR TILE. REPAIR ANY DAMAGED GYPSUM WALL BOARD BACKING BEFORE APPLYING TILE BASE. ASSUME10% REPLACEMENT. REMOVE RUBBER FLOORING & RUBBER BASE. PROVIDE NEW RUBBER FLOORING & 6" RUBBER BASE IN STAIRWELLS AND VESTIBULES. REPAIR ANY DAMAGED WALL BEFORE APPLYING NEW BASE. REMOVE VINYL SHEET FLOORING AND BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. REMOVE VCT FLOORING AND RUBBER BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. PAINT WALLS. REMOVE VINYL WALL COVERING & REFINISH WALL OR REPLACE GYPSUM WALL BOARD AS NECESSARY TO ACHIEVE LEVEL 4 FINISH. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. PAINT ACCORDING TO SPECIFICATIONS. REMOVE AND REPLACE FLOORING IN ELEVATOR. REMOVE & REPLACE MILLWORK. REMOVE & REPLACE LAMINATE IN LAUNDRY ROOMS. SEE MILLWORK DETAILS (A300). REMOVE MILLWORK. SECURE TOILET PARTITIONS. REMOVE AND REPLACE TOILET PAPER DISPENSERS AND SOAP DISPENSERS. REMOVE AND PROVIDE NEW COUNTERTOP AND SINKS. REPLACE 4'X6' RECESSED MAT. MATCH EXISTING DEPTH TO PREVENT TRIP HAZARD. ALUMINUM LINKAGE WITH RUBBER TREAD STRIPS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. REPAIR PEELING WALL FINISH IN STAIRWELLS. PRIME AND PAINT STAIRWELL WALLS AND HANDRAIL. STRIP, CLEAN STAIR NOSING AND CONCRETE. RESEAL/PAINT CONCRETE. REMOVE AND PROVIDE NEW RUBBER FLOORING AT LANDINGS WITH NEW RUBBER BASE. REMOVE AND PROVIDE NEW 32"x32"x6" MOP SINK. COORDINATED WITH EXISTING DRAIN LOCATION. REMOVE AND PROVIDE NEW FAUCET, AND (2) HEAVY DUTY MOP HOLDERS. PROVIDE NEW STAINLESS STEEL MOP SINK SURROUND/BACKSPLASH TO MIN. HEIGHT OF 36" ABOVE SINK TOP. REMOVE AND PROVIDE NEW CORK BOARD BACKING/LINING IN EXISTING DISPLAY CASES. REMOVE AND REPLACE EXISTING DISPLAY CASE WITH NEW WALL MOUNTED 4'X5' HEAVY DUTY LOCKABLE DISPLAY CASE. ALUMINUM FRAME WITH CORK BOARD BACKING. COLOR TO MATCH EXISTING DISPLAY CASES. REMOVE AND REPLACE ELECTRICAL OUTLET AND SWITCH FACEPLATES WITH HEAVY DUTY METAL FACEPLATES. STRIP, CLEAN, & SEAL ALL TILE AND GROUT. REFINISH DOOR TO MATCH EXISTING COLOR AND FINISH. REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS (2/A112). PROVIDE 4' TALL HEAVY DUTY CORNER GUARDS @ ALL OUTSIDE CORNERS. MURALS TO REMAIN-DO NOT PAINT OVER ALL MURALS..

AutoCAD SHX Text

AutoCAD SHX Text REMOVE CARPET AND BASE. REPLACE WITH NEW CARPET TILE AND RUBBER BASE. REPAIR DAMAGED GYPSUM WALL BOARD BACKING (IF NECESSARY) BEFORE INSTALLING BASE. REMOVE BASE. REPLACE WITH COVE TILE BASE TO MATCH EXISTING FLOOR TILE. REPAIR ANY DAMAGED GYPSUM WALL BOARD BACKING BEFORE APPLYING TILE BASE. ASSUME10% REPLACEMENT. REMOVE RUBBER FLOORING & RUBBER BASE. PROVIDE NEW RUBBER FLOORING & 6" RUBBER BASE IN STAIRWELLS AND VESTIBULES. REPAIR ANY DAMAGED WALL BEFORE APPLYING NEW BASE. REMOVE VINYL SHEET FLOORING AND BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. REMOVE VCT FLOORING AND RUBBER BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. PAINT WALLS. REMOVE VINYL WALL COVERING & REFINISH WALL OR REPLACE GYPSUM WALL BOARD AS NECESSARY TO ACHIEVE LEVEL 4 FINISH. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. PAINT ACCORDING TO SPECIFICATIONS. REMOVE AND REPLACE FLOORING IN ELEVATOR. REMOVE & REPLACE MILLWORK. REMOVE & REPLACE LAMINATE IN LAUNDRY ROOMS. SEE MILLWORK DETAILS (A300). REMOVE MILLWORK. SECURE TOILET PARTITIONS. REMOVE AND REPLACE TOILET PAPER DISPENSERS AND SOAP DISPENSERS. REMOVE AND PROVIDE NEW COUNTERTOP AND SINKS. REPLACE 4'X6' RECESSED MAT. MATCH EXISTING DEPTH TO PREVENT TRIP HAZARD. ALUMINUM LINKAGE WITH RUBBER TREAD STRIPS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. REPAIR PEELING WALL FINISH IN STAIRWELLS. PRIME AND PAINT STAIRWELL WALLS AND HANDRAIL. STRIP, CLEAN STAIR NOSING AND CONCRETE. RESEAL/PAINT CONCRETE. REMOVE AND PROVIDE NEW RUBBER FLOORING AT LANDINGS WITH NEW RUBBER BASE. REMOVE AND PROVIDE NEW 32"x32"x6" MOP SINK. COORDINATED WITH EXISTING DRAIN LOCATION. REMOVE AND PROVIDE NEW FAUCET, AND (2) HEAVY DUTY MOP HOLDERS. PROVIDE NEW STAINLESS STEEL MOP SINK SURROUND/BACKSPLASH TO MIN. HEIGHT OF 36" ABOVE SINK TOP. REMOVE AND PROVIDE NEW CORK BOARD BACKING/LINING IN EXISTING DISPLAY CASES. REMOVE AND REPLACE EXISTING DISPLAY CASE WITH NEW WALL MOUNTED 4'X5' HEAVY DUTY LOCKABLE DISPLAY CASE. ALUMINUM FRAME WITH CORK BOARD BACKING. COLOR TO MATCH EXISTING DISPLAY CASES. REMOVE AND REPLACE ELECTRICAL OUTLET AND SWITCH FACEPLATES WITH HEAVY DUTY METAL FACEPLATES. STRIP, CLEAN, & SEAL ALL TILE AND GROUT. REFINISH DOOR TO MATCH EXISTING COLOR AND FINISH. REFER TO ENLARGED TYPICAL ROOM PLAN FOR DORM ROOM RELATED ITEMS (2/A112). PROVIDE 4' TALL HEAVY DUTY CORNER GUARDS @ ALL OUTSIDE CORNERS. MURALS TO REMAIN-DO NOT PAINT OVER ALL MURALS..

AutoCAD SHX Text

AutoCAD SHX Text REMOVE CARPET AND BASE. REPLACE WITH NEW CARPET TILE AND RUBBER BASE. REPAIR DAMAGED GYPSUM WALL BOARD BACKING (IF NECESSARY) BEFORE INSTALLING BASE. REMOVE BASE. REPLACE WITH COVE TILE BASE TO MATCH EXISTING FLOOR TILE. REPAIR ANY DAMAGED GYPSUM WALL BOARD BACKING BEFORE APPLYING TILE BASE. ASSUME10% REPLACEMENT. REMOVE RUBBER FLOORING & RUBBER BASE. PROVIDE NEW RUBBER FLOORING & 6" RUBBER BASE IN STAIRWELLS AND VESTIBULES. REPAIR ANY DAMAGED WALL BEFORE APPLYING NEW BASE. REMOVE VINYL SHEET FLOORING AND BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. REMOVE VCT FLOORING AND RUBBER BASE. REPLACE WITH CERAMIC TILE AND BASE TO MATCH EXISTING TILE FOUND THROUGHOUT BUILDING. PROVIDE STONE TRANSITION IF UNABLE TO MATCH EXISTING TILE FLOOR ELEVATION. PAINT WALLS. REMOVE VINYL WALL COVERING & REFINISH WALL OR REPLACE GYPSUM WALL BOARD AS NECESSARY TO ACHIEVE LEVEL 4 FINISH. PATCH GYPSUM WALLBOARD HOLES, SCRATCHES, AND CRACKS AS NECESSARY. MATCH EXISTING WALL TEXTURE. PAINT ACCORDING TO SPECIFICATIONS. REMOVE AND REPLACE FLOORING IN ELEVATOR. REMOVE & REPLACE MILLWORK. REMOVE & REPLACE LAMINATE IN LAUNDRY ROOMS. SEE MILLWORK DETAILS (A300). REMOVE MILLWORK. SECURE TOILET PARTITIONS. REMOVE AND REPLACE TOILET PAPER DISPENSERS AND SOAP DISPENSERS. REMOVE AND PROVIDE NEW COUNTERTOP AND SINKS. REPLACE 4'X6' RECESSED MAT. MATCH EXISTING DEPTH TO PREVENT TRIP HAZARD. ALUMINUM LINKAGE WITH RUBBER TREAD STRIPS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE. REPAIR PEELING WALL FINISH IN STAIRWELLS. PRIME AND PAINT STAIRWELL WALLS AND HANDRAIL. STRIP, CLEAN STAIR NOSING AND CONCRETE. RESEAL/PAINT CONCRETE. REMOVE AND PROVIDE NEW RUBBER FLOORING AT LANDINGS WITH NEW RUBBER BASE. REMOVE AND PROVIDE NEW 32"x32"x6" MOP SINK. COORDINATED WITH EXISTING DRAIN LOCATION. REMOVE AND PROVIDE NEW FAUCET, AND (2) HEAVY DUTY MOP HOLDERS.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .