Arrestor Plus® Gas Tube Surge Arrestor (350 V), 45–2170 MHz, with interface types N Female Bulkhead and N Female
Product Classification Product Type Surge arrestor
General Specifications Interface N Female Bulkhead
Interface 2 N Female
Device Type dc Pass
Ordering Note CommScope® standard product in Asia Pacific
Body Style Bulkhead
Electrical Specifications Operating Frequency Band 1000 – 2000 MHz | 2000 – 2170 MHz | 45 – 1000 MHz
Average Power 400 W
Connector Impedance 50 ohm
Gas Tube Voltage 350 V
Lightning Surge Current 20 kA
Lightning Surge Current Waveform 8/20 waveform
Insertion Loss, typical 0.10 dB
APG-BNFNF-350
February 13, 2020
©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: November 14, 2019
Outline Drawing
Mechanical Specifications Attachment Durability 25 cycles
Inner Contact Plating Gold
Interface Durability 500 cycles
Interface Durability Method IEC 61169-16:9.5
Outer Contact Plating Silver
Pressurizable No
Dimensions Height 30.99 mm | 1.22 in
Length 68.07 mm | 2.68 in
Weight 0.14 kg | 0.31 lb
Width 30.99 mm | 1.22 in
Environmental Specifications Corrosion Test Method MIL-STD-202, Method 101, Test Condition B
Immersion Depth 1 m
Immersion Test Mating Mated
APG-BNFNF-350
February 13, 2020
©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
Regulatory Compliance/Certifications
* Footnotes
Immersion Test Method IEC 60529:2001, IP68
Mechanical Shock Test Method MIL-STD-202F, Method 213B, Test Condition C
Moisture Resistance Test Method MIL-STD-202, Method 106
Operating Temperature -40 °C to +100 °C (-40 °F to +212 °F)
Storage Temperature -40 °C to +100 °C (-40 °F to +212 °F)
Thermal Shock Test Method MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method GR 2846-CORE
Water Jetting Test Mating Mated
Water Jetting Test Method IEC 60529:2001, IP66
Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 45–1000 MHz 1.11 26.00 1000–2000 MHz 1.17 22.00 2000–2170 MHz 1.33 17.00
Agency Classification ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
Immersion Depth Immersion at specified depth for 24 hours
Insertion Loss, typical 0.05√¯freq (GHz) (not applicable for elliptical waveguide)