Attachment 4- 570-21-701 Final Bid Drawings.pdf
PDF 18 MB Posted
- Solicitation number
- 36C77624B0002
About this file
This document provides details for a federal contract opportunity for training and administrative support services. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals under solicitation number 36C77624B0002 for project #570-21-701 to provide EHRM training and administrative support. An 18MB file of final bid drawings is attached. Proposals are due by the date specified in the solicitation for an award to provide the specified services. Key details include the agency involved, services required, solicitation number, and response due date.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EL 308.5
EL 308.5
BUS
B U S
BUS
65 A B
74 A B
A B
MAIN
ENTRANCE
SIGN
V A
M O N U M E N T
S
IG
N
M O N U M E N T
S
IG
N
S P E E D
B U M P
S P E E D
B U M P
STAGING AREA
G E
N E
R A
T O
R
G E
N E
R A
T O
R
G E
N E
R A
T O
R
G E
N E
R A
T O
R
G E
N E
R A
T O
R
H Y
D R
O N
IC
S
U T
IL
IT
Y P
A D
U T
IL
IT
Y
V A
U L T
FUEL TANK #2FUEL TANK #1
TANK
O2
TANK
O2
TANK
DIESEL
TANK
DIESEL
B-31
COMMUNITY
B-1
MAIN
B-3
ENGINEERING
PUMPHOUSE
B-7
GASOLINE PUMP
B-4
MAIN
B-19 B-19A
GENERATOR
B-2
BOILER PLANT
WAREHOUSE
B-32
O P
C
A N
C
IL
L A
R Y
OPC
OUTPATIENT
B-5
PUMPHOUSE
MENTAL
B-25
B-34
MENTAL HEALTH
HEALTH
FREEDOM
CLINIC
HOSPITAL B-24
LIBERTY
BLDG
LIVING
CENTER
VALOR BLDG
BLDG
B-27
MENTAL HEALTH
INDEPENDENCE BLDG
& TANKS
B-8
STORAGE SHEDS
B-36
BARN
B-24
AUDITORIUM
B-24
TOILETS
B-24
ELEVATOR
B-24 BREEZEWAY
& STAIRS
SWITCHGEARSWITCHGEAR
B-22
CHILLER
B-22A
CHILLER
T-5
ENGR. TRAILER
W A
L K
O F
H O
N O
R
MODULAR 2
LOT C
B-18
ELEVATOR
B-17
LIQUID OXYGEN
STORAGE CANOPY
SHELTER
SMOKING
BBQ
CLC
BUILDING
MOTORCYCLES
YIELD
YIELD
P A R K
IN
G
L O T
HP
A R K
IN
G
L O T
H
PARKING LOT
APARKING LOT
B
P A R K
IN
G
L O T
C
PARKING LOT
E
P A R K
IN
G
L O T
F
PARKING LOT
G
PARKING LOT
D
WAP
FA FA
FAAREA OF WORK
@ BASEMENT
HARVARD AVENUE
F R
E S
N O
S T
R E
E T
N O
R T
H A
N G
U S
S T
R E
E T
CLINTON AVENUE
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
U.S. Department of Veterans Affairs
Basement Renovation
SO/KB
GI-000
COVER SHEET
570-21-701
SMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
02.15.2023
BID DOCUMENTS
FULLY
SPRINKLERED
22006
PROJECT
SITE
RENOVATE APPROXIMATELY 3,500 SF OF BASEMENT SPACE IN THE MAIN
HOSPITAL BUILDING (BLDG 1) INTO TRAINING AND ADMIN SUPPORT SPACES,
INCLUDING A CONFERENCE ROOM, BREAK ROOM, STORAGE AND NEW
ENCLOSURE AROUND EXISTING MECHANICAL AND PLUMBING UTILITIES
NEW FLOORING, CEILING, LIGHTING AND ROOM SIGNAGE TO BE INCLUDED
IN SCOPE OF WORK. PHASING SCOPE TO INCLUDE RELOCATION OF OFFICE
OCCUPANCY INTO A TEMPORARY SPACE DURING CONSTUCTION.
PROJECT DESCRIPTION
VICINITY MAP
PROJECT TEAM
FACILITY
Department of Veteran Affairs VA Sierra Pacific Network 2615 E. Clinton Avenue Fresno, CA 93703
Contact: Ryan P. Gardner P: 559.230.7780 E: ryan.gardner@va.gov
ARCHITECT
MA|Architects, Inc.
385 Van Ness Ave., Suite 110 Torrance, CA 90501
Contact: Steven A. McCaslin P: 424.302.5271 E: s.mccaslin@ma-architects.net
MECHANICAL, ELECTRICAL, & PLUMBING ENGINEER
MEP Energy Solutions Group, Inc.
79705 Star Flower Trail La Quinta, CA 92253
Contact: Ryan Galaz P: 714.975.3501 E: rgalaz@mepesg.com
FIRE ALARM ENGINEER
QA Engineering 1409 Ortiz Dr. SE Albuquerque, NM 87108
Contact: Robert Quintana P: 505.600.2469 E: robert@qaengineering.com
FIRE SPRINKLER ENGINEER
Wiss, Janney, Elstner Associates 16496 Bernardo Center Drive Suite 208 San Diego, CA 92128
Contact: Jim Madden P: 858.987.6726 E: jmadden@wje.com
ENVIROMENTAL ENGINEER
Millenium Consulting Associates 401 Roland Way, Suite 250 Oakland, CA 94621
Contact: Scott Nunes P: 925.808.6700 E: snunes@mecaenviro.com
PROJECT DATA
PROJECT ADDRESS: 2615 E. Clinton Ave.
Fresno, CA 93703
CONSTRUCTION TYPE: TYPE I, SPRINKLERED
STORIES: 7 STORIES + BASEMENT + SUB-BASEMENT +
PENTHOUSE
BLDG. OCCUPANCY : HEALTHCARE
AREA OF WORK: APPROX. 3,500 SF (@ BASEMENT)
DEPARTMENT OF VETERANS AFFAIRS
VA Central California Healthcare System
2615 E. Clinton Ave, Fresno, CA 93703
Remodel Basement for Training & Admin Support
Not to Scale
Reference Site Plan
DEDUCT ALTERNATES
TBD
VA Project No. 570-21-701
Rev. Date Description
02.15.2023 100% Contract Documents - Issue for Bid
02/14/2023
Exp. 12.31.2023
APPLICABLE STANDARDS:
VA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).
2021 International Building Code (IBC) (Only when specifically referenced in VA Design Documents, see notes below)
2021 NFPA 101 Life Safety Code
2019 NFPA 241 Standard for Safeguarding Construction, Alteration, and Demolition Operations
2018 NFPA National Fire Codes with the exception of NFPA 5000 and NFPA 900
Occupational, Safety and Health Administration (OSHA) Standards
2019 VA Seismic Design Requirements, H-18-8
2020 National Electrical Code (NEC) (NFPA 70)
2018 International Plumbing Code (IPC)
2019 Safety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.
2017 ASME Boiler and Pressure Vessel Code
ASME Code for Pressure Piping
2015 Architectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)
Building Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)
Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)
Energy policy Act of 2005 (EPAct)
DOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High- Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.
Federal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)
Executive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.
The Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01 00 00 of the VA Master Construction Specification.
Ventilation for Acceptable Indoor Air Quality – ASHRAE Standard 62.1- 2016.
Safety Standard for Refrigeration Systems – ASHRAE Standard 15 – 2016.
UNLESS OTHERWISE SPECIFIED, SPECIFIC REFERENCES TO CODES, REGULATIONS, STANDARDS, MANUFACTURERS' INSTRUCTIONS, OR REQUIREMENTS OF REGULATORY AGENCIES, SHALL MEAN
THE LATEST EDITION OF EACH IN EFFECT AT THE DATE OF PROJECT SUBMISSION (U.N.O.)
GENERAL NOTES:
1. THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS LISTED BY
THE "INDEX OF DRAWINGS".
2. FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS APPLICABLE ONLY TO THE
DRAWINGS OF ONE DISCIPLINE, REFER TO THE DRAWINGS OF THAT DISCIPLINE - SEE
"INDEX OF DRAWINGS".
3. APPLICABLE PORTIONS OF THE CODES, REGULATIONS, AND STANDARDS LISTED HERE ARE
INCORPORATED BY REFERENCE INTO THE REQUIREMENTS OF THIS CONTRACT AND
ESTABLISH MINIMUM REQUIREMENTS WITH WHICH THE WORK MUST COMPLY.
THIS PROJECT AND ALL PARTS OF THE WORK ASSOCIATED WITH THE PROJECT -
INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC - SHALL COMPLY WITH ALL
APPLICABLE GOVERNING RULES, CODES, REGULATIONS, ORDINANCES, AND LAWS OF ALL
FEDERAL, STATE, DISTRICT, TERRITORIAL, AND LOCAL GOVERNMENT AUTHORITIES HAVING
JURISDICTION OVER THE DESIGN, CONSTRUCTION, AND OCCUPANCY OF THE PROJECT,
WHETHER LISTED BY THE CONTRACT DOCUMENTS OR NOT. NO PART OF THE CONTRACT
DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO AN
APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE, OR LAW.
NO PART OF THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT
WORK CONTRARY TO AN APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE,
OR LAW.
4. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
5. SCHEDULE CONSTRUCTION WORK HOURS TO ACCOMMODATE THE OPERATION OF THE
FACILITY.
6. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH,
WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS. THE
SET OF DRAWINGS, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE "INDEX
OF DRAWINGS". PARTIAL SETS OF DRAWINGS ARE INCOMPLETE.
THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY
THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURE
INSTALLATION REQUIREMENTS. SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH
OTHER, BIDS SHALL BE BASED ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND
QUANTITY OF WORK INDICATED. ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL
BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
7. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND
ELEVATIONS ILLUSTRATE THE DESIGN INTENT. THE ARCHITECTURAL DRAWINGS
ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND LOCATION OF MANY, BUT
NOT ALL, EXPOSED ELEMENTS OF THE WORK. THE STRUCTURAL, MECHANICAL,
ELECTRICAL, PLUMBING, OTHER DRAWINGS, AND JOB SPECIFICATIONS ARE
SUPPLEMENTARY TO ARCHITECTURAL WORKING DRAWINGS. THE WORK DESCRIBED BY
THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON
DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURER INSTALLATION REQUIREMENTS.
SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH OTHER, BIDS SHALL BE BASED
ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND QUANTITY OF WORK INDICATED.
ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO
THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
8. THE SPECIFICATIONS ARE INTENDED TO COMMUNICATE THE DETAILED PROPERTIES AND
QUALITY OF THE INDIVIDUAL MATERIALS, ASSEMBLIES, AND SYSTEMS THAT COMPRISE THE
WORK; THE FUNCTIONAL AND PERFORMANCE REQUIREMENTS FOR THE INDIVIDUAL PARTS
OF THE WORK; AND THE FABRICATION AND INSTALLATION REQUIREMENTS FOR INDIVIDUAL
PARTS OF THE WORK - THE SPECIFICATIONS TAKE PRECEDENCE OVER THE DRAWINGS
WITH RESPECT TO INFORMATION OF THIS NATURE.
9. PROPRIETARY PRODUCTS OR ASSEMBLIES UTILIZED AS "BASIS OF DESIGN":
• ON OCCASION, THE DRAWINGS MAY REFER TO A SINGLE PROPRIETARY PRODUCT
OR ASSEMBLY WHILE THE SPECIFICATIONS LIST TWO OR MORE ACCEPTABLE
MANUFACTURES AND/OR PRODUCTS, WHEN THIS OCCURS, THE PRODUCT OR
ASSEMBLY ILLUSTRATED BY THE DRAWINGS IS THE "BASIS OF DESIGN" PRODUCT OR
ASSEMBLY.
• THE DIMENSIONS, MOUNTING HEIGHTS, CLEARANCES, AND ACCESS REQUIREMENTS
OF SPECIFIED PRODUCTS AND ASSEMBLIES OTHER THAN THE "BASIS OF DESIGN"
MAY VARY FROM THAT SHOWN BY THE DRAWINGS.
• THE CONTRACTOR MAY UTILIZE ANY OTHER SPECIFIED PRODUCT OR ASSEMBLY IN
LIEU OF THE "BASIS OF DESIGN" PRODUCT OR ASSEMBLY, AS APPROVED BY
GOVERNMENT’S REPRESENTATIVE. HOWEVER, THE CONTRACTOR IS RESPONSIBLE
(AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT) FOR ALL COORDINATION AND
REVISIONS TO DIMENSIONS AND/OR DETAILS NECESSARY TO ACHIEVE THE SAME
FUNCTIONAL AND AESTHETIC DESIGN INTENT AS ILLUSTRATED BY THE "BASIS OF
DESIGN" SHOWN BY THE CONTRACT DOCUMENTS.
10. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR
EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS
BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IT IS NOT INTENDED
THAT THE CONTRACT DOCUMENTS INCLUDE EACH & EVERY SUB-SYSTEM AND/OR SUB-
COMPONENT NECESSARY TO FULLY AND PROPERLY COMPLETE THE WORK. SUB-SYSTEMS,
SUB-COMPONENTS OR DETAILS REQUIRED OR NORMALLY INCLUDED AS TRADE PRACTICE
MAY NOT BE SPECIFICALLY MENTIONED NOR SHOWN.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE
ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION OR RELATED WORK.
11. THE ARCHITECT / ENGINEERS SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT
BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE ON
PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
WORK, ALL OF WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL
CONTRACTOR.
12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF
ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH ALL REQUIREMENTS OF THE
CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT
ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE
REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK
OF THAT PARTY.
CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,
DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED
IN THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING OR PATCHING THAT
MAY BE REQUIRED TO COMPLETE WORK OR TO MAKE ITS SEVERAL PARTS FIT TOGETHER.
GENERAL NOTES CONTINUED:
13. THE THE CONTRACTOR SHALL, IN ADVANCE OF THE WORK, PREPARE COORDINATION
DRAWINGS SHOWING THE LOCATION OF OPENINGS THROUGH SLABS, THE PIPE SLEEVES
AND HANGER INSERTS, AS WELL AS THE LOCATION AND ELEVATION OF UTILITY LINES,
INCLUDING, BUT NOT LIMITED TO, CONVEYOR SYSTEMS, PNEUMATIC TUBES, DUCTS, AND
CONDUITS AND PIPES TWO INCHES AND LARGER IN DIAMETER. THESE DRAWINGS,
INCLUDING PLANS, ELEVATIONS, AND SECTIONS AS APPROPRIATE, SHALL CLEARLY SHOW
THE MANNER IN WHICH THE UTILITIES FIT INTO THE AVAILABLE SPACE AND RELATE TO
EACH OTHER AND TO EXISTING BUILDING ELEMENTS. DRAWINGS SHALL BE OF
APPROPRIATE SCALE TO SATISFY THE PREVIOUSLY STATED PURPOSES, BUT NOT SMALLER
THAN 3/8-INCH SCALE. DRAWINGS MAY BE COMPOSITE (WITH DISTINCTIVE COLORS FOR
THE VARIOUS TRADES) OR MAY BE SEPARATE BUT FULLY COORDINATED DRAWINGS (SUCH
AS SEPIAS OR PHOTOGRAPHIC PAPER REPRODUCIBLE) OF THE SAME SCALE. SEPARATE
DRAWINGS SHALL DEPICT IDENTICAL BUILDING AREAS OR SECTIONS AND SHALL BE
CAPABLE OF BEING OVERLAID IN ANY COMBINATION. THE SUBMITTED DRAWINGS FOR A
GIVEN AREA OF THE PROJECT SHALL SHOW THE WORK OF ALL TRADES THAT WILL BE
INVOLVED IN THAT PARTICULAR AREA. COMPLETE COMPOSITE DRAWINGS OR SIX
COMPLETE SETS OF SEPARATE REPRODUCIBLE DRAWINGS SHALL BE RECEIVED BY THE
GOVERNMENT NOT LESS THAN 20 DAYS PRIOR TO THE SCHEDULED START OF THE WORK
IN THE AREA ILLUSTRATED BY THE DRAWINGS, FOR THE PURPOSE OF SHOWING THE
CONTRACTOR’S PLANNED METHODS OF INSTALLATION. THE OBJECTIVES OF SUCH
DRAWINGS ARE TO PROMOTE CAREFULLY PLANNED WORK SEQUENCE AND PROPER
TRADE COORDINATION, IN ORDER TO ASSURE THE EXPEDITIOUS SOLUTIONS OF
PROBLEMS AND THE INSTALLATION OF LINES AND EQUIPMENT AS CONTEMPLATED BY THE
CONTRACT DOCUMENTS WHILE AVOIDING OR MINIMIZING ADDITIONAL COSTS TO THE
CONTRACTOR AND TO THE GOVERNMENT. IN THE EVENT THE CONTRACTOR, IN
COORDINATING THE VARIOUS INSTALLATIONS AND IN PLANNING THE METHOD OF
INSTALLATION, FINDS A CONFLICT IN LOCATION OR ELEVATION OF ANY OF THE UTILITIES
WITH THEMSELVES, WITH STRUCTURAL ITEMS OR WITH OTHER CONSTRUCTION ITEMS,
HE/SHE SHALL BRING THIS CONFLICT TO THE ATTENTION OF THE CONTRACTING OFFICER
IMMEDIATELY. IN DOING SO, THE CONTRACTOR SHALL EXPLAIN THE PROPOSED METHOD
OF SOLVING THE PROBLEM OR SHALL REQUEST INSTRUCTIONS AS TO HOW TO PROCEED
IF ADJUSTMENTS BEYOND THOSE OF USUAL TRADES’ COORDINATION ARE NECESSARY.
UTILITIES INSTALLATION WORK WILL NOT PROCEED IN ANY AREA PRIOR TO THE
SUBMISSION AND COMPLETION OF THE GOVERNMENT REVIEW OF THE COORDINATED
DRAWINGS FOR THAT AREA, NOR IN ANY AREA IN WHICH CONFLICTS ARE DISCLOSED BY
THE COORDINATION DRAWINGS, UNTIL THE CONFLICTS HAVE BEEN CORRECTED TO THE
SATISFACTION OF THE CONTRACTING OFFICER. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO SUBMIT THE REQUIRED DRAWINGS IN A TIMELY MANNER CONSISTENT
WITH THE REQUIREMENTS TO COMPLETE THE WORK COVERED BY THIS CONTRACT WITHIN
THE PRESCRIBED CONTRACT TIME.
14. CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,
DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED
IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
CUTTING, FITTING OR PATCHING THAT MAY BE REQUIRED TO COMPLETE WORK OR TO
MAKE ITS SEVERAL PARTS FIT TOGETHER. THE GENERAL CONTRACTOR IS RESPONSIBLE
TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND
SUPPLIERS WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS.
15. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A
CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE
CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE TO
COORDINATE WITH ALL "OTHER" CONTRACTORS PER REQUIREMENTS ESTABLISHED BY
GOVERNMENT, WHICH ARE UNDER SEPARATE CONTRACT WITH THE GOVERNMENT.
16. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT DRAWINGS, CODE
REQUIREMENTS OR MANUFACTURER REQUIREMENTS WITHOUT THE PRIOR APPROVAL OF
THE GOVERNMENT AND THE ARCHITECT SHALL BE CORRECTED AT THE CONTRACTOR'S
EXPENSE. THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK REJECTED BY THE
GOVERNMENT AS DEFECTIVE OR AS FAILING TO CONFORM TO THE CONTRACT
DOCUMENTS WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND
WHETHER OR NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL
BEAR ALL COSTS OF CORRECTING SUCH REJECTED WORK, NOT TO BE REIMBURSED.
17. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR COORDINATION OF THE WORK OF
THE TRADES, SUBCONTRACTORS, AND MATERIAL SUPPLIERS. THE CONTRACTOR SHALL,
IN ADVANCE OF THE WORK, PREPARE COORDINATION DRAWINGS SHOWING THE LOCATION
OF OPENINGS THROUGH SLABS, THE PIPE SLEEVES AND HANGER INSERTS, AS WELL AS
THE LOCATION AND ELEVATION OF UTILITY LINES, INCLUDING, BUT NOT LIMITED TO,
CONVEYOR SYSTEMS, PNEUMATIC TUBES, DUCTS, AND CONDUITS AND PIPES 2 INCHES
AND LARGER IN DIAMETER. THESE DRAWINGS, INCLUDING PLANS, ELEVATIONS, AND
SECTIONS AS APPROPRIATE, SHALL CLEARLY SHOW THE MANNER IN WHICH THE UTILITIES
FIT INTO THE AVAILABLE SPACE AND RELATE TO EACH OTHER AND TO EXISTING BUILDING
ELEMENTS.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
U.S. Department of Veterans Affairs
Basement Renovation
MA Arch
GI-001
APPLICABLE STANDARDS & SHEET
INDEX
570-21-701
SMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
02.15.2023
BID DOCUMENTS
FULLY
SPRINKLERED
22006
APPLICABLE STANDARDS
ARCHITECTURAL
AD-210 ENLARGED DEMOLITION PLAN
AD-310 ENLARGED DEMOLITON REFLECTED CEILING PLAN
AE-210 ENLARGED RENOVATION PLAN
AE-310 ENLARGED RENOVATION REFLECTED CEILING PLAN
AE-800 DOOR / FINISH SCHEDULES
AE-900 TYPICAL PARTITION DETAILS
AE-901 TYPICAL PARTITION DETAILS
AE-902 TYPICAL CASEWORK DETAILS
AE-903 TYPICAL CEILING DETAILS
GENERAL
GI-000 COVER SHEET
GI-001 APPLICABLE STANDARDS & SHEET INDEX
GI-002 ABBREVIATIONS & SYMBOLS
GI-100 FIRE LIFE SAFETY PLAN
GI-210 OVERALL BASEMENT PLAN
MECHANICAL
M-0.1 LEGEND, SCHEDULES, GENERAL NOTES & ABBREVIATIONS
M-0.2 MECHANICAL DETAILS
MD-2.0 MECHANICAL DEMO PLAN
MH-2.1 MECHANICAL FLOOR PLAN
PLUMBING
P-0.1 PLUMBING LEGEND, SCHEDULES, NOTES, DETAILS & ABBREVIATIONS
PD-2.0 PLUMBING DEMO PLAN
PP-2.1 PLUMBING FLOOR PLAN
ELECTRICAL
E-0.1 LEGEND, GENERAL NOTES & ABBREVIATIONS
E-0.2 DETAILS & SCHEDULES
E-4.1 SINGLE LINE DIAGRAM & PANEL SCHEDULES
ED-2.0 ELECTRICAL DEMO LIGHTING PLAN
EL-2.1 ELECTRICAL LIGHTING PLAN
ED-3.0 ELECTRICAL DEMO POWER PLAN
EP-3.1 ELECTRICAL POWER PLAN
FIRE ALARM & FIRE SPRINKLER
F-001 SYMBOLS, LEGEND & GENERAL NOTES
FD-210 ENLARGED DEMOLITON FIRE ALARM PLAN
FA-210 ENLARGED FIRE ALARM PLAN
FD-310 ENLARGED DEMOLITION FIRE SPRINKLER PLAN
FX-310 ENLARGED RENOVATION FIRE SPRINKLER PLAN
HAZARDOUS MATERIALS
HM-210 ENLARGED DEMOLITION/ABATEMENT PLAN
SHEET INDEXPROJECT GENERAL NOTES CONT. PROJECT GENERAL NOTES
Rev. Date Description
02.15.2023 100% Contract Documents - Issue for Bid
ABC
A
AGGREGATE BASE COURSE
BB
B
BULLETIN BOARD
BD BOARD
BD FT
BHMA
BOARD FEET (FOOT)
BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BI FLD DR BIFOLDING DOORS
BEV BEVEL
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
CAB
C
CABINET
CB CATCH BASIN
CCT
CG
CUBICLE CURTAIN TRACK
CORNER GUARD
CEM
CER
CEMENT, CEMENTITIOUS
CERAMIC
CCTV CLOSED CIRCUIT TELEVISION
CH BD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
CL
CLG
CLR
CMU
CNTR
COL
CONC
CONF
CONN
CONSTR
CONT
CONTR
CORR
CPT
CSK
CSP
CSWK
CU
CW
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COUNTER
COLUMN
CONCRETE
CONFERENCE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CORRUGATED
CARPET
COUNTERSUNK
COMBINATION STANDPIPE
CASEWORK
CUBIC
COLD WATER
D
D
DEPTH
DBL DOUBLE
DBL ACT DOUBLE ACTING
DEG DEGREE
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIM PT DIMENSION POINT
DISP DISPENSER
DIST DISTANCE
DN DOWN
DR DRAIN
DS DOWNSPOUT
DSP DRY STANDPIPE
DT DRAPERY TRACK
DWG DRAWING
DWGS DRAWINGS
(E)
E
EXISTING
EA EACH
EDR EQUIPMENT DRAWING
EG EDGE GUARD
EIFS EXTERIOR INSULATION FINISH SYSTEM
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EP ELECTRICAL PANEL
EPB ELECTRICAL PANEL BOARD
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESCAL ESCALATOR
EST ESTIMATE(D)
EWC ELECTRIC WATER COOLER
EXC EXCAVATED
EXH EXHAUST
EXP EXPANSION
EXP JT EXPANSION JOINT
FURN FURNITURE
FXTR FIXTURE
G
G
GAS
H
H
HIGH
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GFRP GLASS FIBER REINFORCED PLASTIC
GLU LAM GLUE LAMINATED
GLZ GLAZING
GR GRADE OR GRADING
GVL GRAVEL
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
ID
I
INSIDE DIAMETER
JAN
J
JANITOR
KG
K
KILOGRAM
L
L
LENGTH, LONG
M
(N) N
NA
NAAMM
NAT
NATL
NC
NCOMBL
NEC
NEG
NEMA
NEUT
NFC
NFPA
NIC
NO
NOM
NR
NRC
NRCA
NRP
NS
NUM
N
NEW
NORTH
NOT APPLICABLE
NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL MANUFACTURERS
NATURAL
NATIONAL
NOISE CRITERIA
NONCOMBUSTIBLE
NATIONAL ELECTRICAL CODE
NEGATIVE
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUTRAL
NATIONAL FIRE CODE
NATIONAL FIRE PROTECTION
ASSOCIATION
NOT IN CONTRACT
NUMBER
NOMINAL
NOISE REDUCTION
NOISE REDUCTION COEFFICIENT
NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NONREMOVABLE
NARROW STILE
NUM NUMERAL
P
QA
QC
QRY
QT
QTB
QTF
QTR
QTY
QUAD
QUAL
Q
QUALITY ASSURANCE
QUALITY CONTROL
QUARRY
QUARRY TILE
QUARRY TILE BASE
QUARRY TILE FLOOR
QUARTER
QUANTITY
QUADRANT
QUALITY
R
R
RISER
S
SA
SALV
SAMP
SAN
SAT
SATC
SB
SBS
SBSTR
SC
SCH
SCHED
SCHEM
SCP
SCRN
SCT
SCWD
SD
SDG
SECT
SEG
SEL
SEP
SF
SFTWD
SGD
SGL
SHR
SHR HD
SHRH
SHT
SHT MTL
SHTHG
SHV
SIM
SJ
SJI
SK
SKLT
SLD WDW
SLDG
SLNT
SM
SMK
SND
SND INS
SNDU
SPEC
SPKLR
SPKR
SPLY
SQ
SQ IN
SQ YD
SS
SST
ST
STC
STD
STIF
STL JST
STL LNTL
STL PL
STL RF DK
STL TB
STL TR
STNLS
STOR
STR
STRUCT
SUB
SURF
SUSP
SUSP CLG
SV
SW
SWDR
SYM
SYNTH
SYS
SOUTH
SUPPLY AIR
SALVAGE
SAMPLE
SANITARY
SUSPENDED ACOUSTICAL TILE
SUSPENDED ACOUSTICAL TILE CEILING
SPLASH BLOCK
STYRENE BUTADIEN STYRENE
SUBSTRATE
SHADING COEFFICIENT OR SOLID CORE
SCHOOL
SCHEDULE
SCHEMATIC
SCUPPER
SCREEN
STRUCTURAL CLAY TILE
SOLID CORE WOOD DOOR
SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER
SIDING
SECTION
SEGMENT
SELECT
SEPARATE
SQUARE FOOT (FEET)
SOFTWOOD
SLIDING GLASS DOOR
SINGLE
SHOWER
SHOWER HEAD
SHOWER DRAIN
SHEET
SHEET METAL
SHEATHING
SHELVING
SIMILAR
SCORED JOINT
STEEL JOIST INSTITUTE
SKETCH
SKYLIGHT
HORIZONTAL SLIDING WINDOW
SLIDING
SEALANT
SHEET METAL
SMOKE
SANITARY NAPKIN DISPENSER
SOUND INSULATION
SANITARY NAPKIN DISPOSAL UNIT
SPECIFICATION
SPRINKLER
SPEAKER
SUPPLY
SQUARE
SQUARE INCH
SQUARE YARD
SANITARY SEWER OR SERVICE SINK
STAINLESS STEEL
STAIRS OR STREET
SOUND TRANSMISSION CLASS
STANDARD
STIFFENER
STEEL JOIST
STEEL LINTEL
STEEL PLATE
STEEL ROOF DECK
STEEL TUBE
STEEL TRUSS
STAINLESS
STORAGE
STRINGERS
STRUCTURAL
SUBSTITUTE
SURFACE
SUSPEND
SUSPENDED CEILING
SHEET VINYL
SWITCH
SWING DOOR
SYMBOL
SYNTHETIC
SYSTEM
T T&G T&M
TB
TCA
TCP
TD
TECH
TEL
TEMP
TER
THD
THERM
THK
THRES
THRU
THRUOUT
TK BD
TMPD
TMPD GL
TN
TO
TO FDN
TOB
TOM
TOP
TOS
TOW
TPD
TPH
TR
TRANS
TRANS WD FIN
TRTD
TS
TSTAT
TV
TYP
T
TREAD
TONGUE AND GROOVE
TIME AND MATERIALS
THROUGH BOLT OR TOWEL BAR
TILE COUNCIL OF AMERICA
TELEPHONE CONTROL PANEL TEMPERATURE
TRAFFIC CONTROL PLAN
TOWEL DISPENSER
TECHNICAL
TELEPHONE
TEMPERATURE OR TEMPORARY
TERRAZZO
THREAD
THERMAL
THICKNESS
THRESHOLD
THROUGH
THROUGHOUT
TACKBOARD
TEMPERED
TEMPERED GLASS
TRUE NORTH
TOP OF
TOP OF FOUNDATION
TOP OF BEAM
TOP OF MANSORY
TOP OF PARAPET
TOP OF STEEL
TOP OF WALL
TOILET PAPER DISPENSER
TOILET PAPER HOLDER
TOWEL BACK
TRANSOM
TRANSPARENT WOOD FINISH
TREATED
TENSILE STRENGHTH OR TUBE STEEL
THERMOSTAT
TELEVISION
TYPICAL
W
W
WEST
XFMR
X BRACE
XPS
X
TRANSFORMER
CROSS BRACE
EXTRUDED POLYSTYRENE BOARD
(INSULATION)
YD
YR
Y
YARD
YEARHB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HVAC HEATING-VENTILATION-AIR CONDITIONING
IN INCH
INCAND INCANDESCENT
INCL INCLUDE, INCLUDING
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
IVT INTRAVENOUS TRACK
JST JOIST
JT JOINT
KIT KITCHEN
KPL KICK PLATE
KS KNEE SPACE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LH LEFT HAND
LHR LEFT HAND REVERSE
LIB LIBRARY
S
MACH
MACH RM
MAINT
MAN
MATL
MATV
MAX
MB
MCB
MD
ME
MEAS
MECH
MECH RM
MED
MED
MEK
MEL
MEMB
MEMO
MEZZ
MF
MFD
MFG
MFR
MFR REC
MGT
MH
MIC
MID
MIL STD
MIN
MIRR
MISC
MIT
MKR
ML
MLDG
MLWK
mm
PAR
PARA
PART
PAT
PA
PB
PBD
PC
PCA
PCC
PCCP
PCD
PCF
PCP
PED
PEN
PEND
PERF
PERM
PERIM
PERP
PGBD
PHAR
PHOTO
PHS
PKG
PI
PL
PL GL
PLAM
PLAS
PLBG
PLYWD
PMTL
PNEU
PNL
PO
PO
POLY
PR
PRCST
PREFAB
PREFIN
PRELIM
PREP
PRESS
PREV
PRKG
PRMLD
PROJ
PROP
PSF
PSI
PT
PTD
PTN
PVC
PVG
PWR
PARALLEL OR PARAPET
PARAGRAPH
PARTIAL
PATTERN
PUBLIC ADDRESS
PUSHBUTTON
PARTICLEBOARD
PIECE, POLYCARBONATE OR PORTLAND
CEMENT
PORTLAND CEMENT ASSOCIATION
PRECAST CONCRETE
CONCRETE PAVEMENT
PAPER CUP DISPENSER
POUNDS PER CUBIC FOOT
PORTLAND CEMENT PLASTER
PEDESTAL
PENETRATE
PENDANT
PERFORATED
PERMANENT
PERIMETER
PERPENDICULAR
PEGBOARD
PHARMACY
PHOTOGRAPH
PHILLIPS HEAD SCREW
PACKAGE
POINT OF INTERSECTION
PROPERTY LINE
PLATE GLASS
PLASTIC LAMINATE
PLASTER OR PLASTIC
PLUMBING
PLYWOOD
PAINTED METAL
PNEUMATIC
PANEL
POST OFFICE PURCHASE ORDER
PURCHASE ORDER POST OFFICE
POLYETHYLENE (PLASTIC)
PAIR
PRECAST
PREFABRICATE
PREFINISH
PRELIMINARY
PREPARATION
PRESSURE
PREVIOUS
PARKING
PREMOLDED
PROJECT
PROPERTY
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAINT, PNEUMATIC TUBE, OR
PRESSURE TREATED
PAPER TOWEL DISPENSER
PARTITION
POLYVINYL CHLORIDE (PLASTIC)
PAVING
POWER
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
RD ROOF DRAIN
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
REQT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION
RF RESILIENT FLOORING
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHWS ROUND HEAD WOOD SCREW
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RWL RAIN WATER LEADER
UC
U
UNDER COUNTER
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTABLE POWER SUPPLY
UTIL
UCD
UGND
ULT
UNFIN
UR
UV
UTILITY
UNDERCUT DOOR
UNDERGROUND
UNTIMATE
UNFINISH
URINAL
ULTRAVIOLET
W/ WITH
W/O WITHOUT
WC WATER CLOSET OR WALL COVERING
WD WOOD
WDW WINDOW
WGL WIRE GLASS
WCHR WHEELCHAIR
WM WIRE MESH
WO WHERE OCCURS
WPT WORKING POINT
WR WATER RESISTANT
WSCT WAINSCOT
WSP WET STANDPIPE
WT WEIGHT
WTHPRF WEATHERPROOF
WTRPRF WATERPROOF
WWF WELDED WIRE FABRIC
WWM
WARR
WBL
WC WL HNG
WCL WL MTD
WF
WFAB
WFR
WFS
WH
WHSE
WLD
WP
WPD
WPM
WS
WELDED WIRE MESH
WARRANTY
WOOD BLOCKING
WATER CLOSET, WALL HUNG
WATER COOLER, WALL HUNG
WIDE FLANCE
WALL FABRIC
WOOD FRAME
WOOD FURRING STRIPS
WATER HEATER
WAREHOUSE
WELDED
WATERPROOFING
WATER PRESSURE DROP
WATERPROOF MEMBRANE
WEATHERSTRIP
CCR CARD CONTROL READER
BLDG BUILDING
CT CERAMIC TILE
F
F/F FACE TO FACE
FA FIRE ALARM
FAS FIRE ALARM STATION OR FASCIA
FB FLAT BAR
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FF FINISH FACE
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHWS FLAT HEAD WOOD SCREW
FHY FIRE HYDRANT
FLAM FLAMMABLE
FLASH FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF OR FINISHED OPENING
FSB FOLDING SHOWER BENCH
FSTNR FASTENER
FT FOOT, FEET
O/O O
OA
OC
OCC
OCT
OD
OD
OF/CI
OFD
OFF
OF/OI
OH
OH DR
OPH
OPNG
OPP
OPR
OPT
OR
ORD
ORG
ORIG
ORN
OSHA
OUT
OZ
OVHD
O
OUT TO OUT
OXYGEN
OUTSIDE AIR OR OVERALL
ON CENTER
OCCUPY
OCTAGON
OUTSIDE DIAMETER OUTSIDE
DIMENSION
OUTSIDE DIMENSION OUTSIDE
DIAMETER
OWNER FURNISHED/CONTRACTOR
INSTALLED
OVERFLOW DRAIN
OFFICE
OWNER FURNISHED/OWNER INSTALLED
OVERHANG
OVERHEAD (COILING) DOOR
OPPOSITE HAND
OPENING
OPPOSITE
OPERABLE
OPTIONAL
OPERATING ROOM OR OUTSIDE RADIUS
ORDNANCE OR OVERFLOW ROOF
DRAIN
ORGANIC
ORIGINAL
ORNAMENTAL
OCCUPATIONAL SAFETY AND HEALTH
ADMINSTRATION
OUTLET
OUNCE
OVERHEAD
VAC
V
VACUUM
VB VALVE BOX
VCT VINYL COMPOSITION TYLE
VERT VERTICAL
VEST VESTIBULE
VIT VITREOUS
VP VENT PIPE
VOL VOLUME
VWC VINYL WALL COVERING
ABBREVIATIONS SYMBOLS
ANGLE
@ AT
C CENTER LINEL
Ø DIAMETER
= EQUAL
> GREATER THAN
< LESS THAN
± PLUS OR MINUS (TOLERANCE)
# POUND(S)
' FOOT OR FEET
" INCH OR INCHES
FOF FACE OF FINISH
HSS HOLLOW STRUCTURAL STEEL
SYMBOLS LEGENDS
SHEET
X
NORTH IDENTIFIER
ELEVATION
IDENTIFIER
KEY NOTE TAG
GRID LINES
CALL-OUT IDENTIFIER
? PHOTOGRAPH
LOCATIONS
+? CEILING TAG
? WALL TYPE TAG
SHEET #
REF # ON SHEET
WINDOW TAG
DOOR TAG?
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT
AAMA
AIR CONDITIONING UNIT
AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
A/E ARCHITECT / ENGINEER
AB ANCHOR BOLT
AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACST ACOUSTIC
ACS PNL ACESS PANEL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADH ADHESIVE
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGC ASSOCIATED GENERAL CONTRACTORS
AGA AMERICAN GAS ASSOCIATION
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
ALT ALTERNATE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
BLKT BLANKET
BLVD BOULEVARD
BM
BR
BEAM OF BENCHMARK
BEDROOM
BRCG
BRDG
BRACING
BRIDGING
BOT BOTTOM
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT–UP ROOFING
C CELCIUS CHANNEL
C CONC CAST CONCRETE
C TO C
CBB
CENTER TO CENTER
CEMENTITIOUS (BACKER) BOARD
CC
CCW
CUBIC CENTIMETER
COUNTERCLOCKWISE
CAC CEILING ATTENUATION CLASS
CD CONSTRUCTION DOCUMENTS OR CONTRACT
DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI
CF/OI
CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
C LABEL CLASS C DOOR
CFLG
CFM
COUNTERFLASHING
CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY OR CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CHEM
CHFR
CHK
CI
CIP
CIR
CIRC
CNR
CNTR
CO
CONC FLR
COND
CONF
CORR
CMP
CRS
CRSI
CHEMICAL
CHAMFER
CHECK
CAST IRON
CAST–IN–PLACE
CIRLCE
CIRCULAR
CORNER
COUNTER
CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CONCRETE FLOOR
CONDENSER OR CONDITION
CONFERENCE
CORRIDOR
CRITICAL PATH METHOD
COLD ROLLED STEEL
CONCRETE REINFORCING STEEL INSTITUTE
CPRS COMPRESSIBLE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSK
CSWK
COUNTER SUNK
CASEWORK
CTB
CTF
CERAMIC TILE BASE
CERAMIC TILE FLOOR
CSMT CASEMENT
CTG
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
COATING
CTRL CONTROL
CU FT
CU IN
CUBIC FEET
CUBIC INCH
CTR CENTER CONTOUR
CU YD CUBIC YARD
CURT
CYL
CURTAIN
CYLINDER
CYL L CYLINDER LOCK
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEL DELETE
DIR DIRECTION
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DSGN DESIGN
DW DISHWASHER
DWTR DUMBWATER
E EAST
E LABEL CLASS E DOOR
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EJ EXPANSION JOINT
EMER SHR EMERGENCY SHOWER
ENCL ENCLOSURE
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTRYRENE BOARD
(INSULATION)
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESMT EASEMENT
ESP ESPECIALLY
ETC ET CETERA
EW EACH WAY
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP BT EXPANSION BOLT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR
EXTINGUISHER
EXT GR EXTERIOR GRADE
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
F FAHRENHEIT OR FEMALE
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FDTN FOUNDATION
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD
FIG FIGURE
FIL FILLET
FIN FINISH
FHP FULL HEIGHT PARTITION
FLG FLOORING
FLR FLOOR
FIN WD FINISH WOOD
FIXT FIXTURE
FLDG FOLDING
FL FLOORLINE
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FRZ FREEZER
FM–G FACTORY MUTUAL GLOBAL
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MANSORY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FR SINK FLUSHING RIM SINK
FS FEDERAL SPECIFICATION
FURG FURRING
FWC FABRIC WALLCOVERING
FUT FUTURE
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GL GLASS
GI GRAB BAR OR GALVANIZED IRON
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GL BLK GLASS BLOCK
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HCWD HOLLOW CORE WOOD DOOR
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HO HOLD OPEN
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HQ HEADQUARTERS
HS HEAT-STRENGTHENED (GLASS) OR
HIGH STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT
OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
KD KILN DRIED
KO KNOCKOUT
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACHINE
MACHINE ROOM
MAINTENANCE
MANUAL
MATERIAL
MASTER ANTENNA TELEVISION SYSTEM
MAXIMUM
MACHINE BOLT
METAL CORNER BEAD
DECK
MECHANICAL ENGINEER
MEASURE
MECHANICAL
MECHANICAL ROOM
MEDICAL MEDIUM
MEDIUM MEDICAL
METHYL ETHYL KETONE
MELAMINE
MEMBRANE
MEMORANDUM
MEZZANINE
MILL FINISH
MANUFACTURED
MANUFACTURING
MANUFACTURER
MANUFACTURER'S RECOMMENDATION
MANAGEMENT
MANHOLE
MICROPHONE
MIDDLE
MILITARY STANDARD
MINIMUM MINUTE
MIRROR
MISCELLANEOUS
MITER
MARKER
METAL LATH
MOLDING (MOULDING)
MILLWORK
MILLIMETER
MO
MOD
MOD BIT
MON
MOPR
MR
MS
MTD
MTG
MTL
MULL
MW
MWP
MASONRY OPENING OR MOTOR
OPERATED
MODEL, MODIFY OR MODULE
MODIFIED BITUMEN
MONITOR
MOP RACK
MOISTURE RESISTANT
MACHINE SCREW OR MOP SINK
MOUNTED
MOUNTING
METAL
MULLION
MICROWAVE
MEMBRANE WATERPROOFING
RCVT
RLG
RS
RT
RV
RVS
RFI
RFP
RECEIVER
RAILING
ROUGH OPENING
RIGHT
ROOF VENT
REVERSE
REQUEST FOR INFORMATION
REQUEST FOR PROPOSAL
STUD WIDTH PARTITION WIDTHPARTITION TYPE DESIGNATION = 'X'
NON-RATED PARTITION = N
ACOUSTICAL RATED PARTITION = A
SHAFT PARTITION = S
FURRED PARTITION = F
REFER TO PARTITION DETAIL FOR COMPLETE LEGEND & FURTHER INFORMATION.
#X#
PARTITION
TYPE
STUD WIDTH
FIRE RATING
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
U.S. Department of Veterans Affairs
Basement Renovation
Author
GI-002
ABBREVIATIONS & SYMBOLS
570-21-701
SMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
02.15.2023
BID DOCUMENTS
FULLY
SPRINKLERED
22006
ABBREVIATIONS
Rev. Date Description
02.15.2023 100% Contract Documents - Issue for Bid
CHUTE
TO BUILDING
OUTPATIENT CLINIC
B1B16G B1B17A
B1B15
B1B03C
B1B06
B1B01
B1A02
B1B16A
SUITE B1B16
B1B16E
B1A03
B1B03B
B1B08
B1B14A
B1B14B
B1B14B.1
B1B16B
B1B03
B1A04
B1B16D
B1B04
B1B06A
B1B13
B1B10
B1B14
B1B07
B1B09
B1B02
B1B03A
B1A06
B1B17
B1B16C
B1B12A
B1B11A
B1B05
B1B11
B1B16F
B1B16G.1
B1B16G2
B1B07A
B1B12
B1A05
B1B04C
B1B-5 B1B-4
B1B-3
B1-1
B1B00
B1A-2
B1A-1
S-4 S-3
B1B-2
B1B-1
P-2
P-1
B1B-1.1
STORAGE
CORRIDOR
SALAD PREP. AREA
SERVICE
CLOTHING ROOM
CORRIDOR
PASSENGER
ELEVATOR
ELEVATOR LOBBY
DRY
SUITE LOBBY
NUTRITION CLINIC
STORAGE
SERVICE
LAUNDRY
CHUTE
VAULT
MECHANICAL
ELEVATOR ELEVATOR
STAIR
NO. 2
DUMBWAITER
NO. 1
DUMBWAITER
NO. 2
HOUSEKEEPING
STORAGE
DUMBWAITER
NO. 3
LAUNDRY
ELEVATOR
PASSENGER
OFFICE
LOCKER ROOM
KITCHEN DISHWASHING AREA
REFRIGERATOR
CORRIDOR
IRM
SERVICE
SERVER ROOM
MECHANICAL
EMS OFFICE
AREA
IRM SERVICEOFFICE
CORRIDOR
UPS
OFFICE
STORAGE
IRMS OFFICE
IRMS OFFICE
MENS
REST
ROOM
WOMEN'S
REST
ROOM
LOCKERS
IRM CUSTOMER SUPPORT IRM CUSTOMER SUPPORT
CHASE
MECHANICAL
OFFICE OFFICE
CART
WASHER
DRY GOODS
MECHANICAL
CLOSET
WALK-IN
NUTRITION FOOD
DIETICIAN
CLINIC NUTRITION &
CHIEF
FOOD SERVICE
EMPLOYEE DINING
STORAGE
CHEMICAL
INGREDIENT CONTROL
BIOMEDICAL
ENGINEERING
BIOMEDICAL
ENGINEERING
IRM
IRM SERVICE
CHIEF
COMMUNICATIONS
SOILED LAUNDRY
LOST & FOUND
HVAC
MACHINE ROOM
CORRIDOR
STORAGE
WOMEN'S
CORRIDOR
CORRIDOR
CORRIDOR
& SHOWER
CANTEEN
CORRIDOR
DRYERS
ELECTRICAL
STORES
HR
HR
HR
HRDN.
UP
DN.
FD
CLEAR SPACE CENTERED
ON TACTILE CHARACTERS
REFUGE
AREA OF
AREA OF
REFUGE
AREA OF
REFUGE
8"
M in
0"
M ax
3/ 8"
3/ 8"
/8
2"
WALL SIGNAGE
PER IBC 11B-703
1’−6"
LIFE SAFETY LEGEND:
NOTE:
-CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE COMMENCEMENT OF
WORK.
-DIMENSIONS: WALL DIMENSIONS ARE FACE OF FINISHED FACE TO FINISHED
FACE UNLESS NOTED OTHERWISE. WINDOW / DOOR DIMENSIONS ARE TO
CENTER LINE OF WINDOW / DOOR WHERE SHOWN.
-WHERE DIMENSION IS PRECEEDED BY A (±) SYMBOL, THIS
REPRESENTS/ALLOWS A "FLOAT" IN LAYING OUT THE WORK. CONTRACTOR
IS TO NOTIFY ARCHITECT IN WRITING, PRIOR TO FRAMING, IF DIMENSION
EXCEED ±2" FOR DIRECTION ON HOW TO PROCEED.
NEW ACOUSTICAL / NON-RATED PARTITION
(4" STUD U.N.O.)
(E) ACOUSTICAL / NON-RATED PARTITION
(E) PARTITION TO BE DEMOLISHED
(E) 1-HOUR RATED FIRE PARTITION
(E) 2-HOUR RATED FIRE BARRIER
1192 SF
Training B1A01E
650 SF
Business Center B1A01
727 SF
Copier/Accessory Area
B1A01F
174 SF
Break Room B1A01B
214 SF
Mechanical B1A01A
242 SF
Conference Room
B1A01C
54 SF
Storage B1A01D
AE-902 4
OCCUPANCY CALCULATIONS:
BUSINESS CENTER:
NET FLOOR AREA: 650sf OCC. LOAD FACTOR: 650/150sf (BUSSINESS AREAS)
= 4 OCCUPANTS
TRAINING:
NET FLOOR AREA: 1192sf OCC. LOAD FACTOR: 1192/50sf (CONCENTRATED BUSINESS AREA)
= 24 OCCUPANTS
TOTAL OCCUPANTS = 28 OCCUPANTS
REQUIRED EXIT= 1
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
U.S. Department of Veterans Affairs
Basement Renovation
MA Arch
GI-100
FIRE LIFE SAFETY PLAN
570-21-701
SMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
02.15.2023
BID DOCUMENTS
FULLY
SPRINKLERED
22006
Key Notes
001 (E) ACCESSIBLE PATH OF TRAVEL.
002 (E) ACCESSIBLE ENTRANCE.
010 PROVIDE TACTILE EXIT SIGNS NOTING "EXIT ROUTE".
3/8" = 1'-0"
TYP. TACTILE ACCESSIBILITY SIGNAGE
1/8" = 1'-0"
Fire Life Safety Plan
Rev. Date Description
02.15.2023 100% Contract Documents - Issue for Bid
CHUTE
B1A01.1
B1A01
B1A01C B1A01A
B1A01D
B1A01E B1A01B
B1A01.2
B1A01
STORAGE
MECH.
ROOM
TELE
OFFICE
OFFICE
SUITE
HEALTH
INFORMATION
MANAGEMENT
MECH
OFFICE
SUITE
VESTIBULE
TO BUILDING
OUTPATIENT CLINIC
B1B04A
B1B16G B1B17A
B1B15
B1B03C
B1B06
B1B01
B1A02 B1A08
B1A09 B1A07
B1B16A
SUITE B1B16
B1B16E
B1A03
B1B03B
B1B08
B1B14A
B1B14B
B1B14B.1
B1B16B
B1B03
B1A11
B1A12B.1
B1A12A
B1A12B
B1A12
B1A13A
B1A08A.2
B1A08A.1
B1A08A
B1A10
B1A04
B1B16D
B1B04
B1B06A
B1B13
B1B10
B1B14
B1B07
B1B09
B1B02
B1B04B
B1B04B.1
B1B03A
B1A06
B1B17
B1B16C
B1B12A
B1B11A
B1B05
B1B11
B1B16F
B1B16G.1
B1B16G2
B1B07A
B1B12
B1A05
B1B04C
B1B-5 B1B-4
B1B-3
B1-1
B1B00
B1A-2
B1A-5
B1A13
B1A-1
B1A-3
B1A-4
S-4 S-3
B1B-2
B1B-1
P-2
P-1
B1B-1.1
STORAGE
CORRIDOR
SALAD PREP. AREA
CORRIDOR
KITCHEN
SERVICE
CLOTHING ROOM
STAIR
NO. 1
CORRIDOR
PASSENGER
ELEVATOR
ELEVATOR LOBBY
MEAT FREEZER
SALAD
COLD BOX 4
DRY
SUITE LOBBY
NUTRITION CLINIC
STORAGE
SERVICE
LAUNDRY
CHUTE
MEAL PRE-PREP
VAULT
MECHANICAL
ELEVATOR ELEVATOR
AUTOPSY
STAIR
NO. 2
DUMBWAITER
NO. 1
DUMBWAITER
NO. 2
HOUSEKEEPING
STORAGE
DUMBWAITER
NO. 3
MECHANICAL
LAUNDRY
ELEVATOR
PASSENGER
OFFICE
LOCKER ROOM
VEGETABLE FREEZER
REFRIG.
BOX 5
COLD BOX 1
KITCHEN DISHWASHING AREA
REFRIGERATOR
CORRIDOR
IRM
SERVICE
SERVER ROOM
MECHANICAL
INFORMATION
SUPERVISOR
SERVICE
EMS OFFICE
AREA
IRM SERVICEOFFICE
CORRIDOR
CORRIDOR
UPS
OFFICE
STORAGE
IRMS OFFICE
IRMS OFFICE
MENS
REST
ROOM
WOMEN'S
REST
ROOM
LOCKERS
IRM CUSTOMER SUPPORT IRM CUSTOMER SUPPORT
CHASE
MECHANICAL
REST ROOM
FILE
OFFICE OFFICE
KITCHEN PREPARATION AREA
CART
WASHER
DRY GOODS
MECHANICAL
CLOSET
WALK-IN
ELECTRICAL
NUTRITION FOOD
DIETICIAN
CLINIC NUTRITION &
CHIEF
FOOD SERVICE
EMPLOYEE DINING
STORAGE
CHEMICAL
NUTRITION & FOOD DIET
NUTRITION
& FOOD
NUTRITION
PRODUCTION
MANAGER
FOOD
COLD BOX 6
COLD
CORRIDOR
STORAGE
OFFICE
TELECOMMUNICATION
OPERATORS
TELEPHONE
OFFICE
BREAKROOMRESTROOM
COLD BOX 7
COLD BOX 8COLD FOOD PREP
COLD BOX 3
INGREDIENT CONTROL
MEAT PREP.
CHEFS
BIOMEDICAL
ENGINEERING
BIOMEDICAL
ENGINEERING
IRM
IRM SERVICE
CHIEF
COMMUNICATIONS
SOILED LAUNDRY
LOST & FOUND
HVAC
MACHINE ROOM
CORRIDOR
STORAGE
WOMEN'S
CORRIDOR
CORRIDOR
CORRIDOR
& SHOWER
CANTEEN
CORRIDOR
DRYERS
ELECTRICAL
STORAGE
STORES
HR
HR
HR
HR
HR
X
10.A 10 11
1 2 3 4 5 6 7 8
Y
Z
Y
Z
A
B
C
D
E
F
G
12 13 14 15 16 17 18
H
X
DN.
UP
DN.
UP
DN.
AD-210
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
U.S. Department of Veterans Affairs
Basement Renovation
Author
GI-210
OVERALL BASEMENT PLAN
570-21-701
SMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
02.15.2023
BID DOCUMENTS
FULLY
SPRINKLERED
22006
1" = 10'-0"
Overall Basement Plan
Rev. Date Description
02.15.2023 100% Contract Documents - Issue for Bid
Restroom B1B13
130 SF
Men's Women's Restroom
B1B12
148 SF
Women's Lockers B1B12A
99 SF
Service EMS Office
B1B10
324 SF 26 SF
Chase B1B09
Elevator S-4
76 SF 107 SF
Service Elevator
S-3 IRM Storage
B1B01
94 SF
Passenger Elevator
P-1
77 SF
Corridor B1-B
432 SF
TO BUILDING OUTPATIENT CLINIC
Passenger Elevator
P-2
77 SF
Laundry Chute B1A02
161 SF
E
Corridor B1A-1
296 SF
6 7
Housekeeping B1A05
71 SF
+72"
72 SF
Office B1A01C
130 SF
Office B1A01A
Dry Stores
73 SF
F
OIT Laptop Distribution
B1A01
2810 SF 108 SF
Office B1A01.1
Ingredient Control Dry
Goods B1A06
460 SF
74 SF
Comm B1A01.2
Mechanical
WB-106C
37 SF
FD
G
Storage B1A01E
51 SF
H
Mechanical
WB-106B
75 SF
Basement Level (Demolition) 1/4" = 1'-0"
A1
A1
A1
A1
A1
A1
GENERAL NOTES - HAZARDOUS MATERIALS
1. HAZARDOUS MATERIAL ABATEMENT PLANS AND SPECIFICATIONS HAVE BEEN
PREPARED ON THE BASIS OF EXISTING DOCUMENTS AND SITE INSPECTIONS. LOCATION OF
MATERIALS SCHEDULED FOR ABATEMENT ARE GENERAL IN NATURE. DRAWINGS ARE
INTENDED TO PROVIDE AN APPROXIMATE LOCATION OF MATERIALS TO BE REMOVED.
CONTRACTOR IS RESPONSIBLE FOR LOCATING, ACCESSING, AND REMOVING ALL THAT WILL
BECOME OR HAVE THE POTENTIAL TO BECOME DISTURBED.
2. THESE DRAWINGS ARE NOT TO BE CONSIDERED A STAND-ALONE DOCUMENT.
COORDINATE ALL HAZARDOUS MATERIAL RELATED WORK ASSOCIATED WITH DEMOLITION
ACTIVITIES SPECIFIED ELSEWHERE IN THE CONTRACT DOCUMENTS.
3. HAZARDOUS MATERIALS INCLUDING ASBESTOS-CONTAINING MATERIALS HAVE BEEN
IDENTIFIED. THESE MATERIALS MUST BE REMOVED PRIOR TO DEMOLITION OF THE
STRUCTURE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INVESTIGATING AND COORDINATING
ALL WORK UNDER THIS CONTRACT TO DETERMINE TILE EXTENT OF HAZARDOUS MATERIALS
RELATED WORK. CAREFULLY COORDINATE ALL DEMOLITION ACTIVITIES TO ENSURE THE
EXTENT OF DEMOLITION IS LIMITED TO WHAT IS REQUIRED BY THE CONTRACT DOCUMENTS.
5. THE CONTRACTOR SHALL COORDINATE THE REMOVAL OF ALL FURNITURE, FIXTURES,
CASEWORK, FIXED AND MOVEABLE OBJECTS, NON-HAZARDOUS PARTITION WALLS, FINISHES,
ETC., PRIOR TO HAZARDOUS MATERIAL ABATEMENT. REFER TO THE CONTRACT DOCUMENTS
FOR ITEMS SCHEDULED FOR SALVAGE AND REUSE. ANY WORK THAT COULD IMPACT KNOWN
OR ASSUMED HAZARDOUS MATERIALS SHALL BE CONDUCTED WITHIN A NEGATIVE PRESSURE
ENCLOSURE IN ACCORDANCE WITH REQUIREMENTS HEREIN.
6. TO THE EXTENT POSSIBLE, THE CONTRACTOR SHALL CONSTRUCT CONTAINMENT AREAS
TO THE FULL EXTENT OF EACH AREA OR WORK ON EACH FLOOR OR WORK AREA. ADDITIONAL
CLEARANCE SAMPLES RESULTING FROM SEPARATION OF CONTAINMENT AREAS INTO
MULTIPLE CONTAINMENTS WILL BE BACKCHARGED TO THE CONTRACTOR.
7. CONTRACTOR SHALL CAREFULLY SCHEDULE AND COORDINATE ALL PHASES OF
HAZARDOUS MATERIAL RELATED WORK TO ENSURE THAT UNPROTECTED PERSONNEL AND
WORK AREAS ARE NOT EXPOSED TO HAZARDOUS SUBSTANCES. THIS INCLUDES THE
COORDINATION OF ALL DEBRIS CLEANUP, SOFT DEMOLITION, ABATEMENT AND OTHER
CONSTRUCTION ACTIVITIES.
8. ALL SUBMITTALS REQUIRED BY THE PROJECT SPECIFICATIONS MUST BE APPROVED BY
THE VETERANS ADMINISTRATION'S CERTIFIED INDUSTRIAL HYGIENIST (VA CIH) PRIOR TO THE
START OF ANY HAZARDOUS MATERIAL RELATED WORK. REFER TO HAZARDOUS MATERIAL
SPECIFICATIONS.
9. THE CONTRACTOR'S HAZARDOUS MATERIAL ABATEMENT SUBCONTRACTOR SHALL
COORDINATE ALL NECESSARY PRE-ABATEMENT, POST ABATEMENT INSPECTION AND
ABATEMENT RECORD DOCUMENTS FOR REVIEW AND APPROVAL BY THE VA CIH.
10. PROVIDE, OPERATE, AND MAINTAIN MAGNEHELIC GAUGES OR CIRCULAR CHART
RECORDERS OF APPROPRIATE RANGE AT THE ENTRANCE TO EACH WORK AREA DURING
ASBESTOS ACTIVITIES. NO ASBESTOS SHALL BE CONDUCTED UNLESS THE SYSTEM IS
INSTALLED, OPERATING, AND RECORDING CORRECTLY.
11. ALL DIFFERENTIAL AIR PRESSURE UNITS AND VACUUMS MUST BE CHALLENGE TESTED
(DOP EQUIVALENT) ON-SITE PRIOR TO USE.
12. ALL POLYETHYLENE SHEETING AND CONSTRUCTION MATERIALS SHALL BE FIRE
RETARDANT.
13. CONTRACTOR SHALL INSTALL AND ADEQUATE NUMBER OF CLEAR VIEW PORTS TO
EACH WORK AREA. ALL VIEW PORTS SHALL HAVE A MINIMUM DIMENSION OF 18" BY 18".
14. FINAL CLEARANCE FOR ALL ABATEMENT-RELATED WORK WILL BE CONDUCTED BY THE
VA CIH.
ABATEMENT PHASE - PROJECT INTENT
THIS PROJECT INVOLVES THE
PREPARATION, ABATEMENT, AND
RENOVATION OF THE BASEMENT OF
BUILDING 1 OF THE VETERANS
ADMINISTRATION HEALTH CENTER IN
FRESNO, CA.
THE WORK WILL IMPACT REGULATED
BUILDING MATERIALS, AND COMPONENTS.
THE CONTRACTOR IS ADVISED THAT
HAZARDOUS MATERIAL PLANS AND
SPECIFICATIONS ARE NOT STAND-ALONE
DOCUMENTS. THE ABATEMENT
CONTRACTOR'S REVIEW AND
CONSIDERATION OF THE DESIGN PACKAGE
IS AN INHERENT REQUIREMENT AND IS THE
RESPONSIBILITY OF THE ABATEMENT
CONTRACTOR.
ABATEMENT KEYNOTES
A1. REMOVE MASTIC ASSOCIATED WITH
VINYL FLOOR TILE WITHIN THE CLOUDED
AREA (FLOOR TILE AND MASTIC TO BE
TREATED BOTH AS ASBESTOS-CONTAINING)
Rev. Date Description
02.14.2020 35% Schematic Design
06.19.2020 65% Design Development
10.02.2020 95% Construction Documents
11.30.2020 100% Construction Documents
HM-210
ENLARGED DEMOLITION/ABATEMENT
PLANS
570-21-701
401 Roland Way, Oakland, CA 94621 https://www.mecaenviro.com
570-21-701Basement Renovation
AuthorSMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
100% BID DOCUMENTS
FULLY
SPRINKLERED
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net Planning - Architecture - Interiors
Project Number
AREA OF WORK
U.S. Department of Veterans Affairs
Basement Renovation
AuthorSMc
02.15.2023
BID DOCUMENTS
22006
KEY PLAN
02.15.2023 100% Contract Documents - Issue for Bid
Rev. Date Description
BID DOCUMENTS
A1
A1
A1
A1
A1
A1
+72"
FD
H
G
F
E
6 7
37 SF
Mechanical
WB-106C
52 SF
Storage B1A01E
72 SF
Office
B1A01C 130 SF
Office B1A01A
76 SF
Mechanical
WB-106B
108 SF
Office B1A01.1
74 SF
Comm B1A01.2
2792 SF
OIT Laptop Distribution
B1A01
112109
107 SF
Service Elevator
S-3
76 SF
Service Elevator
S-4
95 SF
IRM Storage B1B01
25 SF
Chase B1B09
136 SF
Laundry Chute B1A02
68 SF
Housekeeping B1A05
72 SF
Dry Stores
296 SF
Corridor B1A-1
318 SF
EMS Office B1B10
149 SF
Women's Restroom
B1B12128 SF
Men's Restroom
B1B13
100 SF
Women's Lockers B1B12A
432 SF
Corridor B1-B
459 SF
Ingredient Control Dry
Goods B1A06
104104
117117
123123123
124112
123 123
123 123
125125
126126
127 127
123 123
TYP.
TYP.
TYP.
46 SF
Passenger Elevator
P-1
46 SF
Passenger Elevator
P-2
PARTITION LEGEND:
NOTE:
-CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE COMMENCEMENT
OF WORK.
-DIMENSIONS: WALL DIMENSIONS ARE FACE OF FINISHED FACE TO
FINISHED FACE UNLESS NOTED OTHERWISE. WINDOW / DOOR
DIMENSIONS ARE TO CENTER LINE OF WINDOW / DOOR.
-ALL MTL. STUDS ARE 4" U.N.O. (MATCH FRAMING OF CURRENT
CONDITIONS AS APPLICABLE)
-WHERE DIMENSION IS PRECEEDED BY A (±) SYMBOL, THIS
REPRESENTS/ALLOWS A "FLOAT" IN LAYING OUT THE WORK.
CONTRACTOR IS TO NOTIFY ARCHITECT IN WRITING, PRIOR TO FRAMING,
IF DIMENSION EXCEED ±2" FOR DIRECTION ON HOW TO PROCEED.
(E) 1-HOUR RATED FIRE PARTITION
(E) ACOUSTICAL / NON-RATED PARTITION
(E) PARTITION TO BE DEMOLISHED
(E) 2-HOUR RATED FIRE BARRIER
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
AREA OF WORK
U.S. Department of Veterans Affairs
Basement Renovation
MA Arch
AD-210
ENLARGED DEMOLITION PLAN
570-21-701
SMc
VA Central California Healthcare System 2615 E. Clinton Ave, Fresno, CA 93703
02.15.2023
BID DOCUMENTS
FULLY
SPRINKLERED
22006
Key Notes
101 GENERAL NOTE: REMOVE FURNITURE, SHELVING, AND
OTHER ACCESSORIES ON WALLS, CEILING AND FLOORS.
TURN OVER TO THE VA FOR STORAGE.
102 GENERAL NOTE: REMOVE & ABATE EXISTING
ASBESTOS-CONTAINING FLOOR TILE & MASTIC AND BASE.
PREP SUBSTRATE AS NEEDED TO RECEIVE NEW FLOORING
(REFER TO HM PLAN SHEETS & PROJECT SPECIFICATIONS) .
103 REMOVE PARTITIONS, DOOR ASSEMBLIES & ALL
ASSOCIATED UTILITIES; TYPICAL.
104 REMOVE FURRING AROUND STRUCTURAL COLUMN; REMOVE
EXISTING FIREPROOFING MATERIAL AND PREP FOR NEW
FIREPROOFING.
105 EXISTING AIR HANDLER UNIT TO REMAIN. PROTECT DURING
CONSTRUCTION (REFER TO MECHANICAL PLAN SHEETS)
106 EXISTING UTILITY RISERS TO REMAIN. PROTECT DURING
CONSTRUCTION (REFER TO PLUMBING PLAN SHEETS)
108 REMOVE EXISTING ELECTRICAL OUTLETS, SWITCHES, AND
DATA; TYPICAL (REFER TO ELECTRICAL PLAN SHEETS).
109 REMOVE FURRING WALLS DOWN TO CONCRETE WALL.
CLEAN AND PREP CONCRETE WALL TO RECEIVE NEW
FURRING WALL.
110 REMOVE EXISTING CABINETS, COUNTERTOP AND
ASSOCIATED PLUMBING FIXTURE.
111 REMOVE…
This is the start of the file's text. The full file is on GovTribe.