This file is a questionnaire spreadsheet designed to collect responses from vendors regarding environmental monitoring capabilities for CHEMPACK pharmaceutical storage containers. The questionnaire is part of a Request for Information (RFI) issued by the Administration for Strategic Preparedness and Response (ASPR) under the Strategic National Stockpile (SNS), seeking a validated, secure, scalable monitoring solution for approximately 1,350 CHEMPACK storage locations nationwide containing approximately 1,974 containers.

The spreadsheet contains four sections: company information collection, eighteen detailed RFI questions, and four scenario-based questions. The RFI questions address critical system specifications including physical installation capabilities, primary and secondary power sources, extended backup power operation, data retention and memory capabilities, unit pricing and volume discounts, wireless connectivity and FCC compliance, remote access functionality, and regulatory adherence to Federal, State, and local requirements. Vendors must provide evidence of past U.S. Government contracts for pharmaceutical monitoring equipment, operational deployment experience, compliance with current Good Manufacturing Practice (cGMP) standards under 21 CFR Parts 11, 210, and 211, documentation control procedures, automated reporting of out-of-specification results and alarm conditions, probe accuracy and NIST calibration standards, system maintenance and upgrade protocols, multi-site validation capabilities, cloud-based infrastructure with FedRamp authorization, FIPS-compliant encryption for data at rest and in transit, system diagrams with backup and security architecture, and willingness to provide virtual demonstrations. The scenario-based questions evaluate vendors' capabilities regarding schedule change communication across multiple sites, container relocation detection and monitoring continuity, after-hours door opening event detection and alert procedures with redundancy safeguards, and statewide deployment planning and coordination with local site personnel.

View the file

Other files

File Type Posted
Attachment 1-RFI_STMD 3-12-2026.pdf PDF
Attachment 2-DRAFT STMD SOO 3-12-2026.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tab 1_Company Information Attachment 3 Questionnaire Spreadsheet Tab 1 - Company Information

Company NameBusiness Information
•Point of Contact
•Phone Number
•E-mail AddressWeb Page URLSpecify whether your company is domestically owned or foreign owned. If foreign owned, indicate the country of ownership.Business Size for NAICS Code 334513 and
Socio-Economic CategoryCAGE Code: SAM UEI Number:Is this equipment provided under the FSS schedule or any other GWAC? If so, what is the schedule/contract number?

Tab 2_RFI Questions 1-18 Attachment 3 Questionnaire Spreadsheet Tab 2 - RFI Questions 1-18

* A response is required for every question, or N/A if it does not apply to your company.

Describe several physical locations where the equipment can be installed and operated. Describe the equipment's primary and secondary power sources. Describe the equipment's operation during secondary/backup power supply for an extended period (i.e., 30 days). Describe the capability of your system regarding memory/data retention. Provide a rough unit price estimate for this equipment. Describe any volume or other discounts available for this equipment. Describe the equipment's wireless connectivity, communication and FCC compliance. Describe the equipment's remote access capability. Describe your equipment's adherence to applicable FCC regulations. Include licensing, approval, and manufacturing in accordance with all Federal, State, and local regulations, laws, and statutes. Have you been awarded a US Govt contract for equipment in the past 3-5 years that monitors pharmaceutical products? Is so, provide the contract number and agency/organization supported. Describe how your system has been used in an operational environment or used by customers. Describe how your system/software been utilized in a cGMP environment in pharmaceutical/medical storage. Describe how your equipment meets current Good Manufacturing Practice regulations (cGMP's) standards for providing temperature and security requirements of pharmaceutical equipment as outlined in 21 CFR Parts 11, 210, 211. Describe which cGMP-compliant document control program your company uses (i.e., Quality Manual, Standard Operating Procedure, Validation Documents, Change Control, Deviation, CAPA, etc.). Describe if your system automatically reports out-of-specification results, data loss, connectivity issues, interruption in service/power outage, Mean Kinetic Temperature (MKT), etc.. Describe how your system reports multiple alarm conditions (i.e., container opening alarm, temperature excursions, loss of power/connectivity). Describe how your report captures actual data and graphical representation. Describe the customization ability of reports for the customer (i.e., reporting high and low of the month/year, container/site numbers, days out of spec., MKT values, etc.). Describe the accuracy of your probes and the calibration tolerance/standards in terms of compliance with NIST. Describe how system maintenance and upgrades are handled and how oftern system upgrades are performed. Describe your average installation and validation time of units per site with units in various geographical locations. Describe your simultaneous performance of validations of units at multiple sites. Describe if your system is cloud based and if if it isFedRamp approved and authorized. Describe the data at rest and data in transit encryption with a FIPS compliant method. What is the method? Describe your system diagram to include backup systems and security posture. Provide documentation as a pictorial reference to description. Confirm whether your company would be willing and able to provide a virtual demonstration of a unit and software for evaluation assessment, at the company’s expense.

_x000D_&1#&"Calibri"&10&KF09601 KINDEVA CONFIDENTIAL

Tab 3_Scenario Based Questions Attachment 3 Questionnaire Spreadsheet Tab 3 - Scenario Based Questions SCENARIO 1 – CHEMPACK Site Visit Schedule Adjustment

During routine quarterly maintenance planning, the Contracting Officer’s Representative (COR) must adjust the scheduled site visit dates for several CHEMPACK cache locations due to temporary facility access restrictions. The updated schedule must be communicated to all affected sites to ensure facility access, coordination with local personnel, and continuity of maintenance activities.

QUESTIONS:

1. Describe how your company would ensure that all affected CHEMPACK cache sites are promptly notified of schedule changes.

2. What communication methods or tools would you use to distribute schedule updates across multiple sites and jurisdictions?

3.How would your organization verify that each site received and acknowledged the updated schedule?
SCENARIO 2 – CHEMPACK Container Relocation

During emergency response operations, a CHEMPACK container is temporarily relocated within a jurisdiction to support response activities. The Government must maintain awareness of the container’s location and ensure monitoring continues during and after the move.

QUESTIONS:

1. Describe how your monitoring system or operational processes would detect and record a CHEMPACK container relocation.

2. How would your system notify the Government of the relocation event?

3.What steps would your company take to ensure monitoring continues without interruption after the container is moved?
SCENARIO 3 – After-Hours Door Opening Event

A CHEMPACK unit experiences an unexpected door opening event outside normal operating hours. Because these units store critical medical countermeasures, the Government and designated local contacts must be alerted so the situation can be assessed.

QUESTIONS:

1. Describe how your monitoring solution detects and communicates door opening events to the Government and designated local contacts.

2. What alerting methods does your system use to ensure notifications are transmitted reliably?

3. What redundancy or fail-safe measures help prevent missed or delayed alerts? SCENARIO 4 – Statewide Monitoring System Deployment

The Government plans to deploy environmental monitoring units across multiple CHEMPACK storage sites within a single state. Installations must be coordinated with local site contacts and completed efficiently while minimizing disruption to site operations.

QUESTIONS:

1. Describe your company’s approach to planning and executing monitoring system installations across multiple CHEMPACK sites within a state.

2.How would you coordinate scheduling and access with site personnel?
ANSWERS:

1. 1. 1. 1.