Attachment 3 - Specifications.pdf
PDF 46 KB Posted
- Attached to
- Dyess AFB Mobile Breathing Air Recharging System
- Solicitation number
- FA466124Q0091
About this file
This document is a set of salient characteristics for a Mobile Breathing Air Compressor System Trailer, which is required under the Dyess AFB Mobile Breathing Air Recharging System solicitation.
The key details include: the compressor must be capable of delivering at least 600 PSI of breathing air that meets NFPA 1989 air quality standards, with a minimum flow rate of 15 SCFM. The system should include a multi-stage filtration system, cascade storage cylinders, and be mounted on a weather-resistant trailer. It must have engine-driven or electric power options, efficient cooling, user-friendly controls, and safety features. The system must be certified to meet OSHA, NFPA, and ANSI standards, with easy maintenance and a minimum 1-year warranty. On-site training and technical support are also required. The solicitation number is FA466124Q0091, issued by the Department of the Air Force Global Strike Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 3 - Specifications (Amendment 0001).pdf | ||
| Attachment 2 - 52.212-5.pdf | ||
| Attachment 1 - FAR Provisions and Clauses.pdf | ||
| RFQ FA4661-24-Q-0091.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Mobile Breathing Air Compressor System Trailer
20 Aug 2024
ITEM
NUMBER
DESCRIPTION QUANTITY UNIT
01 Compressor:
Must be high-pressure breathing air compressor capable of delivering at least 600 PSI to fill SCBA cylinders.
1 EA
02 Air Quality:
System must provide air quality that meets or exceeds the NFPA 1989 standard for breathing air quality.
1 EA
03 Capacity:
Must have a minimum flow rate of 15 SCFM (Standard Cubic Feet per Minute)
1 EA
04 Filtration System:
Should include a multi-stage filtration system with moisture separators, oil separators, and CO/CO2 removal.
1 EA
05 Storage Cylinders:
Should be equipped with a cascade storage system capable of holding at least 2 cylinders each with a capacity of 600 PSI.
1 EA
06 Trailer Specifications:
Mounted on a weather-resistant trailer, equipped with appropriate lighting, reflectors, and braking system as per DOT regulations.
1 EA
07 Power Source:
Must include an engine-driven or electric motor option, suitable for both stationary and mobile use.
1 EA
08 Cooling System:
Should have an efficient cooling system to ensure continuous operation in high-temperature environments.
1 EA
09 Control Panel:
User-friendly control panel with digital readouts for pressure, temperature, and operational status.
1 EA
10 Safety Features:
Include automatic shut-off, pressure relief valves, and emergency stop mechanisms.
1 EA
11 Certification:
Must be certified to meet or exceed OSHA, NFPA, and ANSI standards for safety and performance.
1 EA
12 Maintenance and Service:
Easy access for maintenance with recommended service intervals and parts readily available.
1 EA
13 Training and Support: 1 EA
Provide on-site training for operators and maintenance personnel, along with comprehensive user manuals.
14 Warranty:
Minimum one-year warranty on parts and labor.
1 EA
File details come from the government source that posted it. Updated .