This document is a product data sheet for the Falcon 24/25 Series heavy duty touch bar exit devices manufactured by Allegion. The catalog provides comprehensive specifications, ordering information, and available options for panic and fire-rated exit hardware solutions designed for high-traffic commercial applications.
The 24/25 Series consists of two primary product lines: the 25 Series offers wide stile devices suitable for frequent traffic in offices, retail, education, and healthcare settings, while the 24 Series provides narrow stile alternatives for similar applications. Both series are available in multiple device types including rim devices (single-point latch), vertical rod devices (surface-applied two-point latching), concealed vertical rod devices (aesthetic two-point latching), and mortise lock devices. The products feature patented deadlocking technology, extruded aluminum construction, and one trim input design for versatility. Available finishes include brass, bronze, nickel, black matte, chromium, anodized aluminum, and stainless steel in 12 standard color options. Electrical options include motorized electric latch retraction (MEL), delayed egress system components, electric lock/unlock trim (FSA/FSE), exit alarms (EA), and device monitoring (DM, LM, RX). The devices are certified to ANSI A156.3-2001 Grade 1 standards and are available in both panic and fire-rated (UL listed) configurations. Fire-rated models support opening sizes up to 8' x 10' for metal doors depending on device type and rating. Trim designs feature lever, knob, pull, and delta options with multiple lever styles (Dane, Sutro, Quantum, Avalon, Boardwalk, Broadway, Danish, Latitude, and Longitude). Standard accessories include removable mullions, cylinder options, sex bolts, and extension rods. Pricing and availability are managed through part number specifications using modular ordering codes that allow customization of device type, function, finish, handing, and accessories.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 - Accurate Mortise Lock.pdf | ||
| Attachment 4 - PAD-B520 Plan.pdf | ||
| 36C26126Q0372.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
24/25 Series Heavy duty touch bar exit device
VHAPALGozalI Text Box Attachment 3 640-26-1-5046-0017 Panic Hardware Product Data
Table of contents
2 • Falcon • 24/ 25 Series
The Falcon® difference 3
The Falcon 24 and 25 Series 4
Falcon exit devices 5
25 Series exit devices
25-R Series 6
F-25-R Series 7
25-V Series 8
F-25-V Series 9
25-M Series 10
F-25-M Series 11
25-C Series 12
F-25-C Series 13
25 Series accessories and options 14
25 Series strikes and accessories 15
25 Series trim designs 16
25 Series trim and finish charts 17
25 Series types and functions 18
25 Series door application 19
24 Series exit devices
24-R Series 20
F-24-R Series 21
24-V Series 22
F-24-V Series 23
24-C Series 24
F-24-C Series 25
24 Series accessories and options 26
24 Series accessories and strikes 27
24 Series trim designs 28
24 Series trim and finish charts 29
24 Series types and functions 30
24 Series door application 31
Additional options and information
Motorized electric latch retraction for 24/ 25 Series 32
Delayed egress system components for 24/25 Series 34
Electric lock or unlock trim for 25 Series 36
Exit alarm for 24 and 25 Series 37
Device monitoring for 24 and 25 Series 38
Power supply 39
Electrical options summary for 25 Series 40
UL Listed fire exit hardware for 25 Series 41
UL Listed fire exit hardware for 24 Series 42
How to order for 25 Series 43
How to order for 24 Series 44
How to order trim for 24 and 25 Series 45
The Falcon® difference Safety, security and uncompromising value
At Falcon®, we know that every product you sell not only has to meet local building codes, but also your expectations for performance and quality. We take your expectations seriously, and that’s why we build our touch bars to deliver durability, convenience and unmatched value. After all, we’ve built our reputation on the same standards that you have – providing quality products at a reasonable price delivered on time. It’s the way we do business and it’s what makes Falcon exits a powerful choice no matter what your project.
24/ 25 Series • Falcon • 3
4 • Falcon • 24/ 25 Series
Features
The Falcon 24 and 25 Series
One trim input design for maximum versatility.
Clean design with no exposed screws or rivets on the back of the device.
Extruded aluminum construction delivers greater strength and impact resistance.
Patented deadlocking technology ensures reliable security.
The perfectly simple, tougher than nails, costs less than you think, fits anywhere exit device.
Offices, banks, assisted living facilities, retail stores and other commercial buildings have constant traffic, so door hardware must be able to take continual use and abuse. The Falcon 24 and 25 Series exit devices fill the bill with some of the toughest, most reliable performance in the business. A host of features makes this a smart solution, like a choice of an A or B label fire rating, electrified and panic options, and a full complement of trims. Sleek, streamlined styling and a choice of wide (25 Series) and narrow stile (24 Series) device applications means a smart solution for your building design, as well as its use. And since they’re backed by one of the best names in the business, you can be sure you’re getting the utmost value, reliability and durability.
24/ 25 Series • Falcon • 5
24/25 Series 19 Series 1690/1790
• �Maximum flexibility in a variety of applications
• �Wide range of features and options
• �Patent deadlocking technology
• �Lowest cost most dependable light-duty exit
• Large trim selection
• �Standard deadlocking
• �Patented latchbolt for hurricane ratings
• �#1 selling exit device for aluminum doors
• �Electrical options
• �Durable design
• �Frequent traffic
• �Offices, churches, hospitality, retail, education, healthcare
• �Interior, exterior, new construction, retro-fit
• �Moderate traffic
• �Commercial, multi-family, office, retail
• �Interior, exterior, retro-fit
• �Moderate traffic
• �Commercial, multi-family, office, retail
• �Interior, exterior, retro-fit
• �Rim, SV, CV, M
• �6 functions /9 finishes
• �9 lever designs
• �10 year Mechanical warranty
• �1 year Electro-mechanical warranty
• �Rim, SV
• �7 functions /3 lever designs
• �3 finishes
• �10 year Mechanical warranty
• CV = 1690/Rim = 1790
• �4 functions/�5 finishes
• �4 length options
• �10 year Mechanical warranty
• �1 year Electro-mechanical warranty
S el lin g fe at ur es
A p p lic at io ns D ev ic e op ti on s
Architectural push pads Commercial push pads
Falcon exit devices
1990 2090
• �Classic industry look
• �Balanced appearance, dependable performance and economical pricing
• �Hardened steel latches
• �Adjustable strike to ensure safety, security and smooth operation
• �Classic looks in a rim device
• �Designed for high use and abuse
• �1/2" inch steel latchbolt
• �Surface mounted strikes for full frame or blade type stops
• �Light traffic
• �Commercial, multi-family, office, retail
• �Interior, exterior, retro-fit
• �Light traffic
• �Commercial, multi-family, office, retail
• �Interior, exterior, retro-fit
• �CV
• �4 functions/4 finishes
• 2 length options
• �10 year Mechanical warranty
• �Rim
• �4 functions/�4 finishes
• �2 length options
• 10 year Mechanical warranty
D ev ic e op ti on s
S el lin g fe at ur es
A p p lic at io ns
Crossbars Recessed/ concealed devices
25-R Series Rim device
Panic exit hardware The Falcon 25-R Series rim device meets the demanding requirements of high traffic installations with a single-point, rim type latch and a streamlined touch bar design. This device can also be electrified for maximum ease of use and accessibility.
Single door application
Device Door size
Door strike
Door stile (in)
Min door opening width
25-R 3' 299
4" 3 7⁄8" 3 1⁄4" 3 5⁄8"
2' 7 1⁄2" 2' 7 3⁄8" 2' 6 3⁄4" 2' 7 1⁄8"
25-R 4' 299
4" 3 7⁄8" 3 1⁄4" 3 5⁄8"
3' 1 1⁄2" 3' 1 3⁄8" 3' 3⁄4" 3' 1 1⁄8"
299 Strike Cylinder dogging
Dogging key
Double door application
Device Door size
Strike x mullion
Door stile (in)
Min door opening width
25-R 3' 299 x 2923 299 x 4023 264 x 2923 264 x 4023 1439 x 2923 1439 x 4023 1606 x 2923 1606 x 4023
4 1⁄8" 4 3⁄8" 4" 4 1⁄4" 3 7⁄8" 4 1⁄8" 4 1⁄4" 4 1⁄2 "
2' 7 1⁄2" 2' 7 1⁄2" 2' 7 3⁄8" 2' 7 3⁄8" 2' 7 !⁄4" 2' 7 1⁄4" 2' 7 1⁄8" 2' 7 1⁄8"
25-R 4' 299 x 2923 299 x 4023 264 x 2923 264 x 4023 1439 x 2923 1439 x 4023 1606 x 2923 1606 x 4023
4 1⁄8" 4 3⁄8" 4" 4 1⁄4" 3 7⁄8" 4 1⁄8" 4 1⁄4" 4 1⁄2 "
3' 1 1⁄2" 3' 1 1⁄2" 3' 1 3⁄8" 3' 1 3⁄8" 3' 1 !⁄4" 3' 1 1⁄4" 3' 1 1⁄8" 3' 1 1⁄8"
25-Vx 25-R 3' 1609 3 1⁄2" 2' 7 5⁄8" for 3 1⁄2" Min stile
25-Vx 25-R 4' 1609 3 1⁄2" 3’ 1 5⁄8" for 3 1⁄2" Min stile
6 • Falcon • 24/ 25 Series
Specifications
Hand: Non-handed
Finishes: ��US3 (605); US4 (606); US10 (612); US11 (643e); US15
(619); US19 (622); US26 (625); US26D (626); US32
(629); US32D (630); US28 (628), 313AN (710)
(see page 17 for finishes)
Strikes: 299 strike standard (see page 15 for additional info)
Latchbolt: Stainless steel, 3⁄4" throw
Deadlocking latchbolt:
Standard
Dogging feature: Hex dogging standard
Cylinder dogging: �Specify “CD” prefix. Uses 1 1⁄ 8" long mortise cylinder with standard cam
Double cylinder – classroom security:
Available with L function for 25-R-L less dogging and F-25-R-L devices only. Specify handing. Cylinders sold separately. See price book for compatible cylinder options.
Stock sizes: See chart to left; cut to size in the field
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4".
Projections: 2 3⁄4" maximum, 2" dogged
Mounting height: 40 1⁄4" from CL to finished floor
Electric functions: Can be interfaced with building security systems.
Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available
Fasteners: All mounting screws are concealed, sheet metal screws and machine screws standard.
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 8 – 425 (#I0-24) SNB. For devices with trim, specify 2 – 425 (#IO-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
Center case and working parts:
Center case is heavy wrought and sintered metal parts
Shim kits: For glass lite applications; 1⁄4" thick, specify SK25-RM
579 Strike retrofit kit: �Consult factory
F-25-R Series Rim device
Fire exit hardware The Falcon F-25-R Series rim device combines sleek styling and durability with the protection of a fire-rated device.
The F-25-R also features a single-point, rim type latch and can be electrified.
Single door application
Device Door size
Door strike
Min stile (in)
Min door opening width
F-25-R 3' 299-F 4" 2' 7 1⁄2"
F-25-R 4' 299-F 4" 3' 1 1⁄2"
Double door application
Device Door size
Door strike Min stile (in)
Min door opening width
F-25-R 3' 499-F x F-4023 4 1⁄2" 2' 7 5⁄8"
F-25-R 4' 499-F x F-4023 4 1⁄2" 3' 1 5⁄8"
299F Strike 499F Strike
Specifications
Hand: Non-handed
Finishes: ��US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619); US19 (622); US26 (625);
US26D (626); US32 (629); US32D (630); US28
(628), 313AN (710) (see page 17 for finishes)
Strikes: 299F strike standard; 499F standard for pairs with mullion
Latchbolt: Stainless steel, 3⁄4" throw
Deadlocking latchbolt:
Standard
Double cylinder – classroom security:
Available with L function for 25-R -L less dogging and F-25-R-L devices only. Specify handing. Cylinders sold separately. See price book for compatible cylinder options.
Stock sizes: See chart to left; cut to size in the field
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4".
Projections: 2 3⁄4" maximum
Mounting height: 40 1⁄4" from CL to finished floor
Electric functions: Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed, sheet metal screws and machine screws standard
Sex bolts: Required for use in EO applications when used with wood, composite or non-reinforced hollow metal doors. For EO device, specify 8 – 425 (#10-24) SNB. For devices with trim, specify
2 – 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
Center case and working parts:
Center case is heavy wrought and sintered metal parts
Shim kits: For glass lite applications; 1⁄4" thick, specify SK25-RM
24/ 25 Series • Falcon • 7
25-V Series Vertical rod device
Panic exit hardware High-traffic applications demand the added strength and protection that comes with a vertical rod device. The Falcon F-25-V Series delivers with a surface-applied design that includes standard top latch and deadlocking. The sleek touch bar design ensures an attractive installation.
Strike
Dogging key
Latch retention (LR) hold is in the top latch.
Retainer is released when it engages the strike.
Cylinder dogging
Strike
8 • Falcon • 24/ 25 Series
Specifications
Hand: Field reversible
Finishes: ��US3 (605); US4 (606); US10 (612); US11 (643e); US15
(619); US19 (622); US26 (625); US26D (626); US32
(629); US32D (630); US28 (628), 313AN (710)
(see page 17 for finishes)
Strikes: �3788 top strike is surface applied 2130 bottom strike is mortised into floor
Angle bracket Use 4215 angle bracket in flush transom installations Allows use of standard 3788 strike
Latchbolt: Top stainless steel 3⁄4" throw; bottom bolt, 1⁄2" throw
Deadlocking latchbolt: Standard in top latch
Dogging feature: Hex dogging standard
Cylinder dogging: �Specify “CD” prefix. Uses 1 1⁄ 8" long mortise cylinder with standard cam.
Stock sizes: See chart below
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4"
Projections: 2 3⁄4" maximum, 2" dogged
Stile : See chart below
Electric functions: Can be interfaced with building security systems.
Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed, sheet metal screws and machine screws available, specify AMS
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 12 - 425 (#10-24) SNB. For devices with trim, specify 8 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
Vertical rods: �Furnished to length based on a 40 1⁄4" horizontal CL from finished floor and a 7'0" door standard. Variations from these standards must be specified when ordering.
25-V-LBR: Less bottom rod vertical device
Shim kits: For glass lite applications; 1⁄4" thick, specify SK25-V
Device Door size
Door strike
Min stile (in)
Min door opening width
25-V 3' All 3 1⁄2" 2' 7 1⁄8"
25-V 4' All 3 1⁄2" 3' 1 1⁄8"
25-V x 25-R 3' 1609 3 1⁄2" 2' 7 5⁄8" for 3 1⁄2" Min. Stile
25-V x 25-R 4' 1609 3 1⁄2" 2' 1 5⁄8" for 3 1⁄2" Min. Stile
F-25-V Series Vertical rod device
Fire exit hardware When your application requires strength and durability, plus fire rated performance, the F-25-V Series is the total package. This surface-applied vertical rod device includes a sleek touch bar design with top latch and deadlocking standard.
Strike
Strike
Latch retention (LR) hold is in the top latch.
Retainer is released when it engages the strike.
24/ 25 Series • Falcon • 9
Device Door size
Door strike Min stile (in)
Min door opening width
F-25-V 3' All 3 1⁄2" 2' 7 1⁄8"
F-25-V 4' All 3 1⁄2" 3' 1 1⁄8"
Specifications
Hand: Field reversible
Finishes: ��US3 (605); US4 (606); US10 (612); US10B (613); US11 (643e); US15 (619); US19 (622); US26 (625); US26D
(626); US32 (629); US32D (630), US28 (628), 313AN
(710) (see page 17 for finishes)
Strikes: �3788 top strike is surface applied 2130 bottom strike is mortised into floor
Latchbolt: Top stainless steel 3⁄4" throw; bottom bolt, 1⁄2" throw
Deadlocking latchbolt: Standard in top latch
Latch retention hold: Standard with top latch
Stock sizes: See chart below
Doors: �1 3⁄4" thick, wood or metal; specify thickness if other than 1 3⁄4"
Projections: 2 3⁄4" maximum
Stile : See chart below
Electric functions: Can be interfaced with building security systems.
Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available
Fasteners: All mounting screws are concealed. All machine screws (AMS) standard.
Sex bolts: Required when used with wood, composite or non-reinforced hollow metal doors. For EO device, specify 12 - 425 (#10-24) SNB. For devices with trim, specify
8 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
F-25-V: ��Latch Retention (LR) top latch and bottom square bolt.
3788 strike top, 2130 flush strike bottom.
F-25-V-LBR: Less bottom rod vertical device. Auxiliary fire pin required per pair.
Vertical rods: �Furnished to length based on a 40 1⁄4" horizontal CL from finished floor and a 7'0" door standard. Variations from these standards must be specified when ordering.
Shim kits: For glass lite applications; 1⁄4" thick, specify SK25-V
25-M Series Mortise device
Panic exit hardware The Falcon 25-M Series is the only device that pairs a tough, reliable exit device with our strongest mortise lock. The result is maximum safety and security in a single-point, mortise latch type device that also has an attractive touch bar design.
Mortise lock
Standard strike
Dogging key Cylinder dogging
10 • Falcon • 24/ 25 Series
Specifications
Hand: Handed.
Finishes: ��US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619);
US19 (622); US26 (625); US26D (626); US32 (629); US32D
(630); US28 (628), 313AN (710) (see page 17 for finishes)
Strikes: �1279 standard, F1280 and 1281 optional
Latchbolt: 3⁄4" throw
Deadlocking latchbolt: Standard
Dogging feature: Hex dogging standard
Cylinder dogging: �Specify “CD” prefix. Uses 1 1⁄8" mortise cylinder with standard cam.
Mounting height: 40 1⁄4" from CL to finished floor. For mortise lock prep per
ANSI A115.1-1990.
Electric functions: Can be interfaced with building security systems. FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Stile: 4 1⁄2" minimum
Projection: 2 3⁄4" maximum, 2" dogged
Stock Sizes: �See chart on the left
Doors: 1 3⁄4"thick, wood or metal; specify thickness if other than 1 3⁄4"
Fasteners: All mounting screws are concealed, sheet metal screws and machine screws standard
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 6 - 425 (#10-24) SNB. For devices with trim, specify 2
- 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
Mortise lock: �Heavy wrought lock case with investment cast or sintered steel parts. Lock face is forged brass—fits standard cutout.
Locks are designed to fit standard ANSI A115.1 preparation for 1 3⁄4" doors. Deadlocked when auxilary bolt is depressed 5⁄16".
Shim kits: For glass lite applications; 1⁄4" thick, specify SK25-RM
Device Door size
Door strike
Door stile (in)
Min door opening width
25-M 3' All 4 1⁄2" 2' 7 1⁄2"
25-M 4' All 4 1⁄2” 3' 2"
F-25-M Series Mortise device
Fire exit hardware The Falcon F-25-M Series delivers the safety of a fire-rated exit device with a choice of ratings. The F-25-M can be paired with a Falcon mortise lock, assuring a tough and secure lock for any opening requiring a high level of safety and security.
Mortise lock
1279 Standard strike
24/ 25 Series • Falcon • 11
Specifications
Hand: Handed
Finishes: ���US3 (605); US4 (606); US10 (612); US11 (643e);
US15 (619); US19 (622); US26 (625); US26D (626);
US32 (629); US32D (630); US28 (628), 313AN (710)
(see page 17 for finishes)
Strikes: �1279 standard; F1280 optional, B label (1 1⁄2 hr.)
Latchbolt: Stainless steel, 3⁄4" throw
Deadlocking latchbolt: Standard
Stock sizes �See chart on the left
Doors: 1 3⁄4" thick, wood or metal; specify thickness if other than 1 3⁄4"
Projection: 2 3⁄4" maximum
Stile: 4 1⁄2" minimum
Mounting height �40 1⁄4" from CL to finished floor.
For mortise lock prep per ANSI A115.1-1990.
Electric functions: Can be interfaced with building security systems.
FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Fasteners: �All mounting screws are concealed. All machine screws (AMS) standard.
Sex bolts: Required when used with wood, composite or non-reinforced hollow metal doors. For EO device specify 6 - 425 (#10-24) SNB. For devices with trim, specify 2 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
Mortise lock: �Heavy wrought lock case with investment cast or sintered steel parts. Lock face is forged brass—fits standard cutout. Locks are designed to fit standard ANSI A115.1 preparation for 1 3⁄4" doors. Deadlocked when auxiliary bolt is depressed 5⁄16".
Shim kits: For glass lite applications; 1⁄4" thick, specify
SK25-RM
Device Door size
Door strike
Door stile (in)
Min door opening width
F-25-M 3' All 4 1⁄2" 2' 7 1⁄2"
F-25-M 4' All 4 1⁄2" 3' 2"
25-C Series Concealed vertical rod device
Panic exit hardware Concealed vertical rods add strength to the door, while maintaining an attractive appearance. The Falcon 25-C Series concealed vertical rod device offers great value, clean styling and the security benefits of two-point latching. Falcon’s patented center slide mechanism allows easy rod adjustment in the field.
Strike
Deadbolt guide
Strike
650339 Release bracket and plunger
Dogging key
Cylinder dogging
12 • Falcon • 24/ 25 Series
Device Door size
Door strike
Min stile (in)
Min door opening width
25-C 3' All 3 1⁄2" (6 1⁄2" for wood doors) 2' 7 1⁄8"
25-C 4' All 3 1⁄2” (6 1⁄2" for wood doors) 3' 1 1⁄8"
Finishes: ���US3 (605); US4 (606); US10 (612); US11 (643e); US15
(619); US19 (622); US26 (625); US26D (626); US32
(629); US32D (630); US28 (628), 313AN (710)
(see page 17 for finishes)
Strikes: �4188 mortised top, 2130 bottom standard, 4155
Latchbolt: Top stainless steel 3⁄4" throw. Bottom bolt 1⁄2" throw.
Deadlocking latchbolt:
Standard in top latch
Latch retention hold:
Standard in top latch
Dogging feature: Hex dogging standard
Cylinder dogging: �Specify “CD” prefix. Uses 1 1⁄8" long mortise cylinder dogging with standard cam.
Stock sizes: �See chart below
Doors: 1 3⁄4" thick wood or metal. Specify thickness if other than 1 3⁄4". For wood doors, specify as 25-C-WDC.
Projection: 2 3⁄4" maximum, 2" dogged
Stile: 3 1⁄2" minimum (6 1⁄2" minimum on wood doors)
Electric functions: Can be interfaced with building security systems.
Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed, sheet metal screws standard, machine screws available, specify AMS
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 6 - 425 (#10-24) SNB. For devices with trim, specify 2 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
25-C-LBR: ��Less bottom rod concealed vertical device
Vertical rods: Furnished to length based on 40 1⁄4" horizontal CL to finished floor and a 7'0" door. Variations from these standards must be specified when ordering.
Patented centerslide: For ease of adjustment
Shim kits: Consult factory
F-25-C Series Concealed vertical rod device
Fire exit hardware The Falcon F-25-C Series device lets you combine the safety of a fire-rated device with the clean aesthetics that come with a concealed vertical rod installation. In-field adjustment is simple thanks to our patented center slide mechanism.
Two-point latching ensures optimal security at the door.
Strike
Deadbolt guide
Strike
650339 Release bracket and plunger
24/ 25 Series • Falcon • 13
Device Door size
Door strike
Min stile (in)
Min door opening width
25-C 3' All 4" (6 1⁄2" for wood doors) 2' 7 1⁄8"
25-C 4' All 4" (6 1⁄2" for wood doors) 3' 1 1⁄8"
Finishes: ��US3 (605); US4 (606); US10 (612); US11 (643e); US15
(619); US19 (622); US26 (625); US26D (626); US32
(629); US32D (630); US28 (628), 313AN (710)
(see page 17 for finishes)
Strikes: 4188 mortised top, 2130 bottom standard
Latchbolt: Stainless steel, 3⁄4" throw
Deadlocking latchbolt: Standard
Stock sizes �See chart
Doors: 1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4". For wood doors, specify as F-25-C-WDC.
Projection: 2 3⁄4" maximum
Stile: 4" minimum
Mounting height �40 1⁄4" from CL to finished floor
Electric functions: Can be interfaced with building security systems.
Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Fasteners: �All mounting screws are concealed. All machine screws (AMS) standard.
Sex bolts: Required when used with wood, composite or non-reinforced hollow metal doors. For EO device specify 6 - 425 (#10-24) SNB. For devices with trim, specify 2 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
F-25-C-LBR: Less bottom rod, auxiliary fire pin required per pair
Vertical rods: Furnished to length based on 40 1⁄4" horizontal CL to finished floor and a 7'0" door. Variations from these standards must be specified when ordering.
25 Series Accessories and options
Removable mullion
§ The 2923, F4023, 4023, KRF-4023 and KR-4023 steel mullions are for use with the 25-R devices on double door openings.
Advantage: Increased security and tighter closure.
Minimizes door warpage and sag. Regulates the flow of in-and-out traffic
§ Falcon removable mullions are easily removed and reinstalled for full width access
§ Rim devices are used on both leaves, attaining a perfectly symmetrical opening
§ The mullion assembly consists of a mullion, top and bottom mounting brackets and a screw pack
§ The F4023 and KRF-4023 fire-rated mullions also include four stabilizer blocks as required for labeled installations
§ Strikes are not furnished with the mullion. Please see page 15 for strike information
§ Mullions may be cut on the job for doors under stock lengths
§ KR Mullions require 1 1⁄4" mortise cylinder with standard A cam
Mullion features
§ Mullion fittings - ductile iron
§ F4023, 4023, KRF-4023 and KR-4023 - 2" x 3" x height
§ 2923 mullion - 1 1⁄2" x 2 1⁄2" x height
§ Prime coat only
§ 7' or 8' door opening standard, other door opening as specified
Cylinders
§ Cylinder supplied only when specified
§ Cylinders keyed different
Sex bolts
§ 325 (1⁄4"-20 thread)
§ 425 (#10-24 thread)
Dummy touch bars
§ Pushpad is inactive on 250DT.
Pushpad is active on RX250DT or RX-KOR250DT
§ To order, specify 250DT X finish, or RX250DT X finish , or RX-KOR250DT X finish
1 21⁄32"
F-4023 Shown
14 • Falcon • 24/ 25 Series
Cylinder reference
Device Trim Standard key cylinder
IC key cylinder
25 Series device Cylinder dogging
985 - 1 1⁄8" Mortise (A09897-000 cam)
C987 - 1 3⁄8" Mortise #5 cam (Blocking ring plus security collar must equal 1⁄4" thick)
25 Series device Rim & surface vertical
Cylinder only
(NL - OP)
951- Rim cylinder 953 - Rim cylinder
25 Series device Mortise
Cylinder only
(NL - OP)
* 986 - 1 1⁄4" Mortise (A09897-000 cam)
** C987 - 1 3⁄8" Mortise (#5 cam)
25 Series trims L, K, TP, NL 986 - 1 1⁄4" Mortise (A09897-000 cam)
C987 - 1 3⁄8" Mortise (#5 cam)
25 Series trims concealed
718C, 718NL 986 - 1 1⁄4"
Mortise cylinder
N/A
KR4023 mullion N/A 986 - 1 1⁄4” Mortise cylinder (use straight cam "A19897-000")
C987 (#5 cam, 1⁄8" blocking ring)
Strike Installed with mullion
Min stile
B*
299 2923 4 1⁄8" 3"
299 4023 4 3⁄8" 3 1⁄4"
499-F F-4023 4 1⁄2' 3 5⁄16"
264 2923 4" 2 7⁄8"
264 4023 4 1⁄4" 3 1⁄8"
1439 2923 3 7⁄8" 2 3⁄4"
1439 4023 4 1⁄8" 3"
1606 2923 4 1⁄4" 2 5⁄8"
1606 4023 4 1⁄2" 2 7⁄8"
1609 Surface 25-V 4” 2 3⁄8"
(F)25-R Double door application
*�Cylinder must be spaced off of the door a minimum of 1⁄4” via a recessed blocking ring
** �Cylinder must be spaced off of the door a minimum of 3⁄8” via a recessed blocking ring.
Strikes and accessories
�Surface vertical extension rods
Extension rods are available in 12", 24" and 36" lengths in all finishes. Both ends tapped and all-thread included as connector.
Concealed extension rods
Extension rods are available in 12", 24" and 36". Both ends have pressed-in, threaded inserts.
Angle bracket for flush transom applications.
Does not require elimination of latch retention feature. Accepts 3788 strike for 25-V device.
Steel filler plates
| 3721 | Cylindrical lock front filler |
| 3722 | Strike filler - set no. SC for 161 cutout |
| 3723 | Mortise lock front filler |
| 3722 | Strike filler - set no. SM for 86 cutout |
3721/ 3722/ 3723
3721 3722
8"
2 1⁄4" 4 7⁄8"
1 1⁄4"
1 1⁄8"
Filler Plates
1 1⁄4"
Accessories
Closed strike used on single doors and on fire exit hardware doors with coordinator.
F1280 Open back strike used on pairs of 1 3⁄4" doors without astragal or coordinator. Can be used on stock hollow metal doors. F1280 “B” label (1 1⁄2 hr.) stainless steel strike available.
For mortise lock devices
Furnished top of (F)25-V.
41552130 (F)25-V and (F)25-C standard bottom strike for grouting into concrete or masonry floors.
Top strike for (F)25-C.
Optional strike.
Panic device only.
For surface and concealed vertical rod devices
7 7⁄8" x 1 1⁄4" x 13⁄16" (H x W x D) Panic device only.
3 1⁄4" x 1 1⁄16" x 3⁄8" (H x W x D) Requires coordinator.
Panic device only.
2 7⁄8" x 1 1⁄4" x 9⁄16" (H x W x D) Panic device only.
299F 2 7⁄8" x 1 1⁄4" x 13⁄16" (H x W x D)
499F 3 5⁄8" x 1 1⁄2" x 16⁄16" (H x W x D)
Strikes For rim devices
1439 Blade stop 1 3⁄4" x 1 7⁄8" x 1⁄2" (H x W x D) Panic device only.
2 7⁄8" x 1 3⁄8" x 3⁄8" (H x W x D) Panic device only.
24/ 25 Series • Falcon • 15
Trim designs
Escutcheon: 16" x 2 3⁄4" Grip: 6 1⁄4" C- C Projection: 2 11⁄16" Brass For keyed functions, see page 14 for cylinder requirements.
512TP 512NL 512DT 512TP-BE
Delta (717)
717DT
Lever trims (510L)
All levers return to within 1⁄2" of door.
Escutcheon: 9 3⁄4" (H) x 2 3⁄4" (W) (specify handing) brass finish.
Protected by easily replaceable shear pin.
Lever is reversible, supplied RHR if not specified. For keyed functions, see page 14 for cylinder requirements.
510L
510L-NL
510L-DT
510L-BE
Vandal - resistant lever trims (511L)
Pull trims (512)
Provides resistance to rotation, making damage of trim due to attack from the outside less likely.
Designed to operate normally after vandalism attempts without the need for maintenance personnel intervention.
Functionality built into the trim, facilitating easy door preps, easy field retrofit and easy ordering.
§ Heavy duty, vandal-resistant, ANSI AI56.3 grade 1 security trim
§ Lever deflects up to 22 ft-lb for a minimum of 10,000 vandal-resistant cycles
§ Vandal resistance is present in both lever rotation directions
§ After lever is fully deflected, lever stops rotating and a shear pin breaks at 70 ft-lb to prevent damage to unit
§ Available on 25 rim, vertical, mortise, and concealed devices
§ Retrofits all existing 25 trim without additional door prep
§ Works with all electric lock and unlock functions
§ �Available in all finishes and lever designs including Avalon, Boardwalk, Broadway, Dane, Danish, Latitude, Longitude, Sutro, and Quantum
23/4” 7/8”
93/4”
Lever designs
Key retracts latch bolt.
Cylinder sold separately (see page 14).
718C required for 25-C-C (NLOP) function.
Cylinder only (NL-OP)
Round ball knob Escutcheon: 9 3⁄4" x 2 3⁄4" Projection: 4" Brass For keyed functions, see page 14 for cylinder requirements.
| 513K-DT | 513K |
| 513K-BE | 513K-NL |
Knob trims (513K)
16 • Falcon • 24/ 25 Series
Avalon (AVA) Projection 3 1⁄4"
Boardwalk (BRK) Projection 3 1⁄5"
Broadway (BRW) Projection 3 1⁄5"
Dane (DAN) Projection 3"
Latitude (LAT) Projection 3 1⁄10"
Longitude (LON) Projection 3 1⁄10"
Sutro (SUT) Projection 3 1⁄4"
Quantum (QUA) Projection 3 1⁄4"
Danish (DSH) Projection 2 9⁄10”
Trim chart and finish chart
25 Series finishes Color US number BHMA number
Brass, bright US3 605
Brass, satin US4 606
Bronze, satin US10 612
Bronze, aged US11 643e*
Nickel, satin US15 619*
Black, matte US19 622*
Chromium, bright US26 625
Chromium, satin US26D 626
Anodized aluminum US28 628
Stainless Steel, bright US32 629
Stainless Steel, satin US32D 630
�Anodized duranodic 313AN 710
24/ 25 Series • Falcon • 17
Function
Lock/ unlock NL DT BE FSA/ FSE
Lever (510) 510L 510L-NL 510-DT 510L-BE 510L-FSA
510L-FSE
Vandal-resistant lever (511)
511L — — — 511L-FSA
511L-FSE
Pull trims (512) 512TP 512-NL 512DT 512TP-BE 512L-FSA
512L-FSE
Knob (513) 513K 513K-NL 513K-DT 513K-BE 513L-FSA
513L-FSE
Delta (717) — — 717DT — —
*Available on select devices and trims
Types and functions
This page shows all 25 Series device and trim functions.
EO (01)
Exit only, no trim.
Functions (ANSI) (F)-25-R (F)-25-V (F)-25-M (F)-25-C
25-R-EO 25-V-EO 25-M-EO 25-C-EO
25-R-DT 25-V-DT 25-M-DT 25-C-DT
25-R-NL 25-V-NL 25-M-NL 25-C-NL
DT (02)
Entrance by trim when actuating bar is locked down.
NL (03)
Entrance by trim when latchbolt is retracted by key. Key removable only when locked.
TP (05)
Entrance by thumbpiece. Key locks or unlocks thumbpiece.
25-R-TP 25-V-TP 25-M-TP 25-C-TP
Rim device ANSI type 1
Vertical rod device ANSI type 2
Mortise lock device ANSI type 3
Concealed vertical rod device ANSI type 8
25-R-L/K 25-V-L/K 25-M-L/K 25-C-L/K
L or K (08) Entrance by knob or lever. Key locks or unlocks knob.
25-R-L/K(NL) 25-V-L/K(NL) 25-M-L/K(NL) 25-C-L/K(NL)
L(NL) or K(NL) (03) Entrance by knob or lever when latchbolt is retracted by key. Lever/knob is rigid. Key removable only when locked.
18 • Falcon • 24/ 25 Series
Door application
Door application chart
Label doors Models F-25-R, F-25-M, F-25-C and F-25-V are labeled for use as Fire exit hardware.
Door thickness All devices and components supplied for 1 3⁄4" doors standard. Specify door thickness if other than 1 3⁄4".
Product information and specifications contained in this catalog are subject to change without notice. Please consult the factory.
INSIDE
RIGHT HAND
Reverse Bevel
(RHR)
Single Door 25-R 25-M
RIGHT HAND
Reverse Bevel
(RHR)
LEFT HAND
Reverse Bevel
(LHR)
LEFT HAND
Reverse Bevel
(LHR)
INSIDE
Pair of Doors with Mullion 25-R x 25-R
Pair of Doors without Mullion 25-R x 25-V 25-V or V-LBR x 25-V or V-LBR 25-C x 25-C 25-M x 25-V 25-M x 25-C
3' = 33" 4' = 45"
9"
2 5⁄8"
2 1⁄4"
3' = 20 3⁄16" 4' = 26 3⁄16"
23⁄4" Full extend
2" Full depress
24/ 25 Series • Falcon • 19
Inside
Right hand reverse bevel
(RHR)
Right hand reverse bevel
(RHR)
Left hand reverse bevel
(LHR)
Left hand reverse bevel
(LHR)
Inside
Single door 25-M 25-R
Pair of doors with mullions 25-R x 25-R
Pair of doors without mullions 25-R x 25-V 25-V or V-LBR x 25-v or V-LBR 25-C x 25-C 25-M x 25-V 25-M x 25-C
20 • Falcon • 24/ 25 Series
Panic exit hardware The Falcon 24-R Series narrow stile rim device allows for application versatility in high-traffic installations. Standard features include a single-point, rim type latch and a streamlined touch bar design. This device can also be electrified for maximum ease of use and accessibility.
2789 Dogging key Cylinder dogging
24-R Series Rim device
299 Strike
Device Door size
Door strike
Min stile (in)
Min door opening width
24-R 3' 299
3 1⁄2" 3 3⁄8" 2 1⁄4" 2 3⁄4"
2' 7 1⁄2" 2' 7 3⁄8" 2'6 3⁄4" 2' 7 1⁄8"
24-R 4' 299
3 1⁄2" 3 3⁄8" 2 1⁄4" 2 3⁄4"
3' 1 1⁄2" 3' 1 3⁄8" 3' 3⁄4"
Single door application
Device Door size
Door strike Min stile (in)
Min door opening width
24-R 3' 299 x 2923 299 x 4023 264 x 2923 264 x 4023 1439 x 2923 1439 x 4023 1606 x 2923 1606 x 4023
3 1⁄2" 4" 3 3⁄8" 3 5⁄8" 3 1⁄2" 3 3⁄4" 3 1⁄2" 3 3⁄4"
2' 7 1⁄2" 2' 7 1⁄2" 2' 7 3⁄8" 2' 7 3⁄8" 2' 7 1⁄8" 2' 7 1⁄8" 2' 7 1⁄8" 2' 7 1⁄8"
24-R 4' 299 x 2923 299 x 4023 264 x 2923 264 x 4023 1439 x 2923 1439 x 4023 1606 x 2923 1606 x 4023
3 1⁄2" 4" 3 3⁄8" 3 5⁄8" 3 1⁄2" 3 3⁄4" 3 1⁄2" 3 3⁄4"
3' 1 1⁄2" 3' 1 1⁄2" 3' 1 3⁄8" 3' 1 3⁄8" 3' 1 1⁄8" 3' 1 1⁄8"
3' 1 1⁄2"
Double door application
Hand: Non-handed
Functions: �24-EO (exit only) has all functions built in. Order trim with the device, or add it later (see trim selection chart on page 29).
Finishes: US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619); US19 (622); US26 (625);
US26D (626); US32 (629); US32D (630); US28
(628), 313AN (710) (see page 29 for finishes)
Strikes: 299F strike standard. See page 27 for optional strikes.
Latchbolt: Stainless steel, 3⁄4" throw
Deadlocking latchbolt: Standard
Dogging feature: Hex Dogging Standard
Stock sizes: See chart to left
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4".
Projections: 2 3⁄4" maximum, 2" dogged
Mounting height: 40" from CL to finished floor
Electric functions: Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 4 - 425 (#I0-24) SNB and 2 - 325 (1⁄4"-20) SNB. For devices with trim, specify 4 - 425 (#I0-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards.
Center case & working parts:
Wrought steel with heavy wrought and sintered metal parts
Shim kits: For glass lite applications; 1⁄4" thick, specify
SK24-R
24/ 25 Series • Falcon • 21
Fire exit hardware The Falcon F-24-R Series rim device combines sleek styling and durability with the protection of a fire-rated device. A narrow stile design allows for installation versatility. The F-24-R also features a single-point, rim type latch and can be electrified.
299F Strike
F-24-R Series Rim device
Device Door size
Door strike
Min stile (in)
Min door opening width
F-24-R 3' 299-F 3 1⁄2" 2' 7 1⁄2"
F-24-R 4' 299-F 3 1⁄2” 3' 1 1⁄2"
Single door application
Device Door size
Door strike Min stile (in)
Min door opening width
F-24-R 3' 299-F x F-4023 4" 2' 7 1⁄2"
F-24-R 4' 299-F x F-4023 4" 3' 1 1⁄2"
Double door application
Hand: Non-handed
Functions �F-24-REO (Exit only) has all functions built in.
Order trim with the device, or add it later.
(see trim selection chart on page 29)
Finishes: US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619); US19 (622); US26 (625);
US26D (626); US32 (629); US32D (630);
US28 (628), 313AN (710)
(see page 29 for finishes)
Strikes: 299F strike standard
Latchbolt: Stainless steel, 3⁄4" throw
Deadlocking latchbolt: Standard
Stock sizes: See chart to left
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4".
Projections: 2 3⁄4" maximum
Mounting height: 40" from CL to finished floor
Electric functions: Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed. Furnished with all machine screws.
Sex bolts: Required when used with wood, composite or non-reinforced hollow metal doors. For EO device, specify 4 - 425 (#10-24) SNB and 2 - 325 (1⁄4"-20) SNB. For devices with trim, specify 4 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
Center case & working parts:
Investment-cast ferrous alloy with heavy wrought and sintered metal parts
Shim kits: For glass lite applications; 1⁄4" thick, specify
SK24-R
22 • Falcon • 24/ 25 Series
High-traffic applications demand the added strength and protection that comes with a vertical rod device. The Falcon 24-V Series delivers with a surface-applied design that includes standard top latch and deadlocking. The narrow stile and sleek touch bar design ensure an attractive installation.
Dogging key
3788 Strike
Latch retention hold is in the top latch. Retainer is released when it engages the strike. The door is in the closed position.
Strike
24-V Series Vertical rod device
Cylinder dogging
Device Door size Door strike
Min stile (in)
Min door opening width
24-V 3' All 2 1⁄8" 2' 7 1⁄4"
24-V 4' All 2 1⁄8” 3' 1 1⁄4"
Functions: 24-V-EO (exit only) has all functions built in. Order trim with the device, or add it later (see trim selection chart on page 29).
Finishes: US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619);
US19 (622); US26 (625); US26D (626); US32 (629); US32D
(630); US28 (628), 313AN (710) (see page 29 for finishes)
Strikes: 3788 top strike is surface applied, 2130 bottom strike is mortised into floor
Angle Bracket: Use 4215 angle bracket in flush transom installations. Allow use of standard 3788 strike.
Latchbolt: Top stainless steel, top latch 3⁄4" throw, bottom bolt 1⁄2" throw
Deadlocking latchbolt: Standard with top latch
Latch retention hold: Standard with top latch. On top latch.
Dogging feature: Hex Dogging Standard
Stock sizes: See chart below
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4" thick.
Projections: 2 3⁄4" maximum, 2" dogged
Stile: 2 1⁄8" minimum when used in pairs
Electric functions: Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed, sheet metal screws standard, machine screws available, specify AMS
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 8 - 425 (#10-24) SNB and 2 - 325 (1⁄4"-20) SNB. For devices with trim, specify 8 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
24-V: Latch retention (LR) top latch and bottom square bolt. 3788 strike top, 2130 flush strike bottom.
24-V-LBR: Less bottom rod vertical
Vertical rods: Furnished to length based on a 40" horizontal CL from finished floor and a 7'0" door standard. Variations from these
Shim kits: For glass lite applications; 1⁄4" thick, specify SK24-V
24/ 25 Series • Falcon • 23
Fire exit hardware When your application requires strength and durability, plus fire-rated performance, the F-24-V Series is the total package. This surface-applied vertical rod device includes a sleek touch bar design with top latch and deadlocking standard, as well as a narrow stile that fits where you need it to.
F-24-V Series Vertical rod device
2130 Strike
3788 Strike
Latch retention hold is in the top latch. Retainer is released when it engages the strike. The door is in the closed position.
Device Door size Door strike
Min stile (in)
Min door opening width
F-24-V 3' All 2 1⁄8" 2' 7 1⁄4"
F-24-V 4' All 2 1⁄8" 3' 1 1⁄4"
Functions: F-24-V-EO (exit only) has all functions built in. Order trim with the device, or add it later (see trim selection chart on page 29).
Finishes: US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619);
US19 (622); US26 (625); US26D (626); US32 (629); US32D
(630); US28 (628), 313AN (710) (see page 29 for finishes)
Strikes: 3788 top strikes are surface applied, 2130 bottom strike is mortised into floor
Latchbolt: Top stainless steel, top latch 3⁄4" throw, bottom bolt 1⁄2" throw
Latch retention hold: Standard with top latch
Deadlocking latchbolt: Standard with top latch
Stock sizes: See chart below
Doors: �1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4" thick.
Projections: 2 3⁄4" maximum
Stile: 2 1⁄8" minimum when used in pairs
Electric functions: Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed. All machine (AMS) standard.
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 8 - 425 (#10-24) SNB and 2 - 325 (1⁄4-20) SNB. For devices with trim, specify 8 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
F-24-V: Latch retention (LR) top latch and bottom square bolt. 3788 strike top, 2130 flush strike bottom.
F-24-V-LBR: Less bottom rod vertical device. Auxiliary fire pin required per pair.
Vertical rods: Furnished to length based on a 40" horizontal CL from finished floor and a 7'0" door standard. Variations from these
Shim kits: For glass lite applications; 1⁄4" thick, specify SK24-V
24 • Falcon • 24/ 25 Series
Concealed vertical rods add strength to the door, while maintaining an attractive appearance. The Falcon 24-C Series concealed vertical rod device offers great value, clean styling, a versatile narrow stile design and the security benefits of two-point latching. Falcon’s patented center slide mechanism allows easy rod adjustment in the field.
24-C Series Concealed vertical rod device
2130 Strike
4188 Strike
Cylinder dogging
Dogging key
650339 Release bracket and plunger
4567 Deadbolt guide
Device Door size Door strike
Min stile (in)
Min door opening width
24-C 3' All 2 1⁄4" (6" for wood doors) 2' 7 3⁄8"
24-C 4' All 2 1⁄4” (6" for wood doors) 3' 1 3⁄8"
Hand: Field reversible or specify handing
Functions: See trim selection chart on page 29. Delta trim only.
Finishes: US3 (605); US4 (606); US10 (612); US11 (643e); US15
(619); US19 (622); US26 (625); US26D (626); US32 (629);
US32D (630); US28 (628), 313AN (710)
(see page 29 for finishes)
Strikes: 4188 mortised top and 2130 flush strike bottom, optional bottom 2126A and 4155
Latchbolt: Top stainless steel, top latch 3⁄4" throw. Bottom bolt 1⁄2" throw.
Deadlocking latchbolt: Standard with top latch
Latch retention hold: Standard with top latch
Dogging feature: Hex Dogging Standard
Cylinder dogging: Specify “CD” prefix. Uses 1 1⁄8" long mortise cylinder dogging with standard cam.
Stock sizes: See chart below
Doors: �1 3⁄4" thick, wood or metal. Specify if other than 1 3⁄4" thick.
For wood doors, specify as 24-C-WDC
Projections: 2 3⁄4" maximum, 2" dogged
Stile: 2 1⁄4" minimum when used in pairs (6" minimum on wood doors)
Electric functions: Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed, sheet metal screws standard, machine screws available, specify AMS
Sex bolts: Recommended when device is used with hollow core wood, composite or light gauge hollow metal doors. For EO device, specify 2 - 425 (#10-24) SNB and 2 - 325 (1⁄4-20) SNB.
For devices with trim, specify 2 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
24-V-LBR: Less bottom rod concealed vertical device
Vertical rods: �Furnished to length based on 40" horizontal CL to finished floor and a 7'0" door. Variations from these standards must be specified when ordering.
Patented centerslide: For ease of adjustment
24/ 25 Series • Falcon • 25
Fire Exit Hardware The Falcon F-24-C Series device lets you combine the safety of a fire-rated device with the clean aesthetics that come with a narrow stile and concealed vertical rod installation. In-field adjustment is simple thanks to our patented center slide mechanism. Two-point latching ensures optimal security at the door.
F-24-C Series Concealed Vertical Rod Device
2130 Strike
650339 Release bracket and plunger
4567 Deadbolt guide
4188 Strike
Specifications
Hand: Field reversible
Functions: See trim selection chart on page 29. Delta trim only.
Finishes: �US3 (605); US4 (606); US10 (612); US11 (643e); US15
(619); US19 (622); US26 (625); US26D (626); US32
(629); US32D (630); US28 (628), 313AN (710)
(see page 29 for finishes)
Strikes: 4188 mortised top, 2130 flush strike bottom
Latchbolt: Top stainless steel, 3⁄4" throw. Bottom bolt 1⁄2" throw.
Latch retention hold: Standard with top latch
Deadlocking latchbolt: Standard with top latch
Stock sizes: See chart below
Doors: 1 3⁄4" thick metal. Specify if other than 1 3⁄4" thick. For wood doors, specify as F-24-C-WDC.
Projections: 2 3⁄4" maximum
Stile: 3 5⁄8" minimum when used in pairs (6" minimum on wood doors)
Electric functions: Can be interfaced with building security systems.
Motorized electric latch retraction (fail secure only), security monitoring, delayed egress and exit alarm available.
Fasteners: All mounting screws are concealed. All machine screws standard.
Sex bolts: Required when used with wood, composite or non-reinforced hollow metal doors. For EO device specify 2 - 425 (#10-24) SNB and 2 - 325 (1⁄4"-20) SNB.
For devices with trim, specify 2 - 425 (#10-24) SNB.
ANSI: Certified ANSI A156.3-2001 grade 1 standards
F-24-C-LBR Less bottom rod concealed vertical device. Auxiliary fire pin required per pair.
Vertical rods: Furnished to length based on 40" horizontal CL to finished floor and a 7'0" door. Variations from these standards must be specified when ordering.
Patented centerslide: For ease of adjustment
Shim kits: Consult factory
Device Door size Door strike
Min stile (in)
Min door opening width
F-24-C 3' All 3 5⁄8" (6" for wood doors) 2' 7 3⁄8"
F-24-C 4' All 2 1⁄4" (6" for wood doors) 3' 1 3⁄8"
26 • Falcon • 24/ 25 Series
Removable mullion
§ The 2923, 4023, KR4023 steel mullions are for use with the 24-R devices on double door openings. Advantage:
Increased security and tighter closure. Minimizes door warpage and sag. Regulates the flow of in-and-out traffic.
§ Removable mullions are easily removed and reinstalled for full width access.
§ Rim devices are used on both leaves, attaining a perfectly symmetrical opening.
§ The mullion assembly consists of a mullion, top and bottom mounting brackets and a screw pack. Soffit adapters are available for use with either the 2923 or the 4023 mullion.
§ Strikes are not furnished with the mullion. Please see page 27 for strike information.
§ Mullions may be cut on the job for doors under stock lengths.
Mullion features
§ Mullion fittings – ductile iron
§ 4023 – 2" x 3" x height
§ KR4023 cylinder removable mullion – 2" x 3" x height and uses 1 1⁄4" mortise cylinder not furnished
§ 2923 mullion – 1 1⁄2" x 2 1⁄2" x height
§ 423 mullion – T shape (1" on latch edge) supplied with 4396 adjustable strike
§ Prime coat only
§ 7' or 8' door opening standard, other door opening as specified
4023 Shown
24 Series Accessories and options
Cylinder reference
Device Trim Standard key cylinder
IC key cylinder
24 Series device Cylinder dogging
985 - 1 1⁄8" Mortise (A09897-000 cam)
C987 - 1 3⁄8" Mortise #5 cam (Blocking ring plus security collar must equal 1⁄4" thick)
24 Series trims L, K 986 - Mortise (A09897-000 cam)
C987 - Mortise cylinder
24 Series trims NL - Rim and surface vertical
718C, 718NL
951- Rim cylinder C953 - Rim cylinder
24 Series trims Concealed
718C, 718NL
986 - 1 1⁄4" Mortise (#4 cam) C (Schlage B520-295 cam or similar must be used)
N/A
Strike Installed with mullion
Min stile
B*
299 2923 3 1⁄2" 2 3⁄16"
299 4023 4" 2 7⁄16"
264 2923 3 3⁄8" 2 1⁄16"
264 4023 3 5⁄8" 2 5⁄16"
1439 2923 3 7⁄16" 1 7⁄8"
1439 4023 3 11⁄16" 2 1⁄8"
1606 2923 3 5⁄16" 1 7⁄8"
1606 4023 3 11⁄16" 2 1⁄8"
24-R Double door application
Cylinders - control trim
§ Cylinder supplied only when specified.
§ Cylinders available keyed alike.
Sex bolts
§ 325 (1⁄4"-20 thread)
§ 425 (#10-24 thread)
1 21⁄32"
24/ 25 Series • Falcon • 27
24 Series Accessories and strikes
�Surface vertical extension rods
Extension rods are available in 12", 24" and 36" lengths in all finishes. Both ends tapped and all-thread included as connector.
Concealed extension rods
Extension rods are available in 12", 24" and 36". Both ends have pressed-in, threaded inserts.
Angle bracket for flush transom applications.
Does not require elimination of latch retention feature. Accepts 3788 strike for 24-V device.
Steel filler plates
| 3721 | Cylindrical lock front filler |
| 3722 | Strike filler - set no. SC for 161 cutout |
| 3723 | Mortise lock front filler |
| 3722 | Strike filler - set no. SM for 86 cutout |
3721/3722/3723
3721 3722
8"
2 1⁄4" 4 7⁄8"
1 1⁄4"
1 1⁄8"
Filler plates
1 1⁄4"
Accessories
Furnished top of (F)24-V.
41552130 (F)24-V and (F)24-C standard bottom strike for grouting into concrete or masonry floors.
Top strike for (F)24-C.
Optional strike.
Panic device only.
For surface and concealed vertical rod devices
Strikes For rim devices
7 7⁄8" x 1 1⁄4" x 13⁄16" (H x W x D) Panic device only.
2 7⁄8" x 1 1⁄4" x 9⁄16" (H x W x D) Panic device only.
299F 2 7⁄8" x 1 1⁄4" x 13⁄16" (H x W x D)
1439 Blade stop 1 3⁄4" x 1 7⁄8” x 1⁄2"
2 7⁄8" x 1 3⁄8" x 3⁄8" (H x W x D) Panic device only.
(H x W x D) Panic device only.
28 • Falcon • 24/ 25 Series
Trim designs
Lever trims (712L)
17/8” 3/4”
81/8”
712L
712L/NL
712L/DT
712L/BE
Key retracts latch bolt.
Cylinder sold separately (see page 26).
Brass and/or plated finishes.
For cylinder information see page 26.
When locking function is not required, specify trim by (BE) blank escutcheon.
Cylinder information
Athena (715)
Grip overall: 9 1⁄8" Width: 1 11⁄16" Pull: 6 1⁄4" C x C Projection: 2 1⁄4 "
715DT
711K
711-NL
Knob trim (711K)
Round ball knob Escutcheon: 8 1⁄8" x 1 7⁄8" Projection: 3 7⁄8" Brass For keyed functions, see page 26 for cylinder requirements.
Delta trims
Specify handing Escutcheon: 8 1⁄8" x 1 7⁄8" Projection: 2 1⁄4" All Delta pulls: 6 1⁄4" C x C NL and DT: 14 1⁄16" x 2 1⁄4"
718DT 717DT 718TL 718TL-BE
All levers return to within 1⁄2" of door.
Escutcheon: 8 1⁄8" (H) x 1 7⁄8" (W) (specify handing) brass finish.
Protected by easily replaceable shear pin.
Lever is reversible, supplied RHR if not specified. For keyed functions, see page 26 for cylinder requirements.