ATTACHMENT 3 - DRAWINGS.pdf
PDF 7 MB Posted
- Solicitation number
- 1232SA26Q0694
About this file
This document is a set of electrical construction drawings for the Hatchery Complex Electrical Distribution Addition project at the Warmwater Aquiculture Research Unit in Stoneville, Mississippi, prepared by the U.S. Department of Agriculture Agricultural Research Service. The project is identified under A/E Contract No. 12405B21D0003 and A/E Task Order No. 12405B24F0123, with a project number of 2024-E and work area K-MAGEE.
The drawings comprise eight sheets including a title sheet, legend and abbreviations, site plan, power plan, details, existing single line diagram, single line diagram for new work, and panel schedules. Key work includes installation of new pole-mounted transformers providing power to underground service feeders; a new 50 kW generator; new electrical panels (P.84.N replacement with 400A capacity and new P.84.S 100A standby panel); new hanging quad and single receptacles; and associated electrical infrastructure including conduit, conductors, grounding systems, and equipment pads. The project involves disconnecting and removing existing conductors and transformers, demolishing existing devices, and installing new three-phase 480Y/277V distribution equipment. The drawings specify copper conductors, RMC conduit, equipment grounding requirements with ground rods and bonding jumpers, and contain detailed schematics for neutral and grounding systems, trench details, receptacle installations, and panel schedules for multiple buildings (46, 47, 47A, 47B, 47C, 48, 54, 58, 59, and 84) within the facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M I S S I S S I P P I
GRENADA
WINONA
HATTIESBURG
NO SCALE
GREENVILLE
VICKSBURG
HOLLANDALE1
JACKSON
ROSEDALE
GREENWOOD
VICINITY MAP
MEMPHIS
GULFPORT
STARKVILLE
COLUMBUS12
ALT
45PROJECT
LOCATION
TUPELO
N
WARMWATER AQUICULTURE RESEARCH UNIT
AGRICULTURAL RESEARCH SERVICE
U.S. DEPARTMENT OF AGRICULTURE
INDEX OF DRAWINGS
SHEET NO. TITLE
LOCATION MAP NO SCALE
N
T1 E1 E2 E3 E4 E5 E6 E7
TITLE SHEET
LEGEND AND ABBREVIATIONS
SITE PLAN
POWER PLAN
DETAILS
EXISTING SINGLE LINE
SINGLE LINE
PANEL SCHEDULES
STONEVILLE, MISSISSIPPI
HATCHERY COMPLEX ELECTRICAL DISTRIBUTION ADDITION
N
W
S
E
X
X
X X
X X
X
XX
X X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
XXX
X
X X
X X
X
X X X
X X
XX
XX
XX XXXXXX
X X X X X X X X X
X X
X
X X X X XX X XX X X X X X X
X
X X
X X X X X X X X X X X X X X X X X X X
BLDG. #46
BLDG. #58
BLDG. #59BLDG. #47
BLDG. #84
SH
OP
B
LD
G.
#4
#4 7A
#5
ENTRANCE
U. S. DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
CATFISH GENETICS UNIT
LOCATION MAP
STONEVILLE, MISSISSIPPI
XXXXXXXXXX
X
XXX
XX
X
X X X X X X X X X X X X X X X X X X X X X
X X
X
X
X
USDA
SPRAY
DISPOSAL
AREA
WELL
MAIN.SWBD
BLDG. #84 SHED
NEW GREENHOUSE
EXIST GREENHOUSE
A/E CONTRACT NO. 12405B21D0003
A/E TASK ORDER NO. 12405B24F0123
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITON
STONEVILLE, MS
TITLE SHEET
T1 1 808/16/2024
BSN
TMT
DRL
MID SOUTH AREA
STONEVILLE, MS
2024-E
K-MAGEEWORK AREA
A OR AMP AMPERE(S)
ACC AIR COOLED CHILLER
AC ALTERNATING CURRENT
AC AIR COMPRESSOR / AIR
CURTAIN
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING
CAPACITY
AL ALUMINUM
AM AMMETER
ASYM ASYMMETRICAL
AT AMP TRIP
ATS AUTOMATIC TRANSFER
SWITCH
AUTO AUTOMATIC
AWG AMERICAN WIRE GAUGE
B BOILER
BC BRANCH CONTROLLER
BCW BARE COPPER WIRE
BFF BELOW FINISHED FLOOR
BFG BELOW FINISHED GRADE
BLDG BUILDING
C CONDUIT
CAT CATEGORY
CB CIRCUIT BREAKER
CCT CORRELATED COLOR
TEMPERATURE
CCTV CLOSED CIRCUIT
TELEVISION
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CH CHILLER
CHWCP CHILLED WATER
CIRCULATING PUMP IN A
PRIMARY-SECONDARY
SYSTEM
CHWP CHILLED WATER PUMP
CHWSP CHILLED WATER SUPPLY
PUMP IN A PRIMARY-
SECONDARY SYSTEM
CKT CIRCUIT
CMH COMMUNICATIONS
MANHOLE
CP CONDENSATE PUMP
CPT CONTROL POWER
TRANSFORMER
CRAC COMPUTER ROOM AC UNIT
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CT COOLING TOWER
CU COPPER OR CONDENSING
UNIT
CWP CONDENSER WATER PUMP
D DEPTH
DC DIRECT CURRENT
DF DESTRATIFICATION FAN
DH or DUH DUCT HEATERS
DHWCP DOMESTIC HOT WATER
CIRCULATING PUMP
DISC DISCONNECT SWITCH
DOAS DEDICATED OUTSIDE AIR
SYSTEM (UNIT)
DPST DOUBLE POLE SINGLE
THROW
DPDT DOUBLE POLE DOUBLE
THROW
DSCU DUCTLESS SPLIT
CONDENSING UNIT
(POWERS THE DSS INDOOR
UNIT)
DSHP DUCTLESS SPLIT HEAT
PUMP (POWERS THE DSS
INDOOR UNIT)
DSS DUCTLESS SPLIT SYSTEM
(INDOOR UNIT)
DWBP DOMESTIC WATER
BOOSTER PUMP
DX DIRECT EXPANSION (DX)
COOLING COIL
EC EMPTY CONDUIT
EF EXHAUST FAN
ELEC ELECTRICAL
EMH ELECTRICAL MANHOLE
EMT ELECTRICAL METALLIC
TUBING
E or EMER EMERGENCY
EPA EFFECTIVE PROJECTED
AREA
EQUIP EQUIPMENT
ERV ENERGY RECOVERY
VENTILATOR
ERU ENERGY RECOVERY UNIT
ETR EXISTING TO REMAIN
NOTE: ABBREVIATIONS ABOVE
ARE FOR ELECTRICAL SHEETS
ONLY. NOT ALL ABBREVIATIONS
SHOWN WILL BE USED ON THIS
PROJECT.
ABBREVIATIONS LIST
EUH ELECTRIC UNIT HEATER
EXP EXPLOSION PROOF
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
F FUSE
FACP FIRE ALARM CONTROL
PANEL
FCU FAN COIL UNIT
FLEX FLEXIBLE
FWE FURNISHED WITH
EQUIPMENT
G OR GND GROUND
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFI GROUND FAULT
INTERRUPTER
GRS GALVANIZED RIGID STEEL
CONDUIT
GUH GAS UNIT HEATER
GWH GAS WATER HEATER
H or HT HEIGHT
HAC HEATED AIR CURTAIN
HOA HAND-OFF AUTOMATIC
HP HORSE POWER
HP HEAT PUMP (OUTDOOR
PORTION OF SPLIT SYSTEM
HEAT PUMP, USE CU FOR
STANDARD DX OUTDOOR
UNIT)
HT HEAT TRACKING
HVU HEATING/VENTILATING UNIT
HWCP HEATING WATER
CIRCULATING PUMP IN A
PRIMARY-SECONDARY
SYSTEM
HWP HEATING WATER SUPPLY IN
A PRIMARY-ONLY SYSTEM
HWRP HOT WATER
RECIRCULATION PUMP
HWSP HEATING WATER SUPPLY
PUMP IN A PRIMARY-
SECONDARY SYSTEM
HWUH HOT WATER UNIT HEATER
HZ HERTZ
IDS INTRUSION DETECTION
SYSTEM
IMC INTERMEDIATE METAL
CONDUIT
IRH INFRARED HEATER
J OR JB JUNCTION BOX
K KILO
KAIC THOUSAND AMPERE
INTERRUPTING CAPACITY
KCM OR KCMIL THOUSAND OF CIRCULAR
MILS
KEF KITCHEN EXHAUST FAN
KH KITCHEN HOOD
KV KILOVOLT
KVA KILOVOLT-AMPERES
KW KILOWATT
KWHR KILOWATT-HOUR
L LENGTH
LA LIGHTNING ARRESTOR
LAN LOCAL AREA NETWORK
LAV LAVATORY
LM LOCKHEED MARTIN
LTG LIGHTING
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPACITY
MCB or MB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MGB MAIN GROUND BAR
MH MANHOLE or MOUNTING
HEIGHT
MIN MINIMUM
MLO MAIN LUGS ONLY
MOD MOTOR OPERATED DAMPER
MT or MTD MOUNT or MOUNTED
MRS MOTOR RATED SWITCH
N NEUTRAL
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NC NORMALLY CLOSED
NESC NATIONAL ELECTRICAL
SAFETY CODE
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
P POLE(S) or PUMP
PA PUBLIC ADDRESS
PDU POWER DISTRIBUTION UNIT
PF POWER FACTOR
PH PHASE
PIU VAV TERMINAL UNIT WITH
PARALLEL OR SERIES FAN
(PRIMARY INDUCTION UNIT)
PMT PAD MOUNTED
TRANSFORMER
PNL PANEL OR PANELBOARD
PTAC PACKAGED THRU-WALL AIR
CONDITIONER
PVC POLYVINYL CHLORIDE
RECEPT or RECP RECEPTACLE
RF RETURN FAN
RH RADIANT HEATERS
(ELECTRIC)
RMC RIGID METAL CONDUIT
RMS ROOT MEAN SQUARE
RTU ROOF TOP UNIT
RVNR REDUCED VOLTAGE NON-
REVERSING
SA SURGE ARRESTOR
SCCR SHORT CIRCUIT CURRENT
RATING
SD SMOKE DAMPER
SF SUPPLY FAN
S/N SOLID NEUTRAL
SP SUMP PUMP
SPD SURGE PROTECTIVE DEVICE
SPDT SINGLE POLE DOUBLE
THROW
SPEC SPECIFICATIONS
SPST SINGLE POLE SINGLE
THROW
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TMGB TELECOMMUNICATIONS
MAIN GROUNDING BUSBAR
TOL THERMAL OVERLOAD
TP TWISTED PAIR
TYP TYPICAL
U URINAL
UH UNIT HEATER
UG UNDERGROUND
UIO UNLESS INDICATED
OTHERWISE
UL UNDERWRITERS
LABORATORY
UTP UNSHIELDED TWISTED PAIR
V VOLTS
VA VOLT AMPERES
VAV VAV TERMINAL UNIT
VEF VEHICLE EXHAUST FAN
VM VOLTMETER
VRF VARIABLE REFRIGERANT
FLOW SYSTEM
W WATTS or WIRE or WIDTH
WC WATER CLOSET
WEF WELDING EXHAUST FAN
WH WATER HEATER
WHDM WATTHOUR DEMAND METER
WSHP WATER SOURCE HEAT
PUMP
WP WEATHERPROOF
XFMR TRANSFORMER
Z IMPEDANCE
GENERAL NOTES - ELECTRICAL:
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT
INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE
AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. REVIEW ALL PROJECT DOCUMENTS PRIOR TO START OF CONSTRUCTION. REPORT ANY
DISCREPANCIES TO CONTRACTING OFFICER PRIOR TO PROCEEDING WITH WORK.
DIMENSIONS RELATING TO EXISTING CONSTRUCTION ARE TO BE FIELD VERIFIED. THE
CONTRACTOR SHALL IMMEDIATELY COMMUNICATE, IN WRITING TO THE CONTRACTING
OFFICER, CONCERNS WHERE THEY BELIEVE DESIGN DOCUMENTS ARE INSUFFICIENT,
INADEQUATE OR INCORRECT FOR PERFORMING THE CONSTRUCTION WORK.
3. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT
DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR
IMPLIED THEREFROM.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF WORK SEQUENCING SUCH
THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
5. PRODUCTS SHALL BE INSTALLED PER MORE STRINGENT REQUIREMENTS OF THE DESIGN
DOCUMENTS OR THE MANUFACTURER'S PRINTED INSTRUCTIONS FOR THE INDICATED
APPLICATION. THESE INSTRUCTIONS SHALL BE MAINTAINED ON SITE FOR THE DURATION OF
THE INSTALLATION AT A MINIMUM.
6. WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED
STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, THE
REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING
REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE
CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
7. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW WORK.
8. WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF WORK
AGREEMENT.
9. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL
OF MATERIALS AND RUBBISH.
10. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY DIMENSIONS AND SHALL VERIFY NEW AND
EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE
CONTRACTING OFFICER IN WRITING OF ANY DIFFERING CONDITIONS BEFORE
COMMENCEMENT OF WORK.
11. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER
SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN
WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
12. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH APPLICABLE CODES,
ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY BUILDING AND
FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
13. PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS SHALL
BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE
RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.
14. THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION FOR
PERSONS AND PROPERTY, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY
HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
15. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN
OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE OWNER'S REPRESENTATIVE
PRIOR TO START OF SUCH WORK.
16. MINIMUM RACEWAY SIZE SHALL BE 3/4". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT
RACEWAY FILL RATIO TO LESS THAN 40% FULL.
17. THE ELECTRICAL CONTRACTOR SHALL CAREFULLY COORDINATE WORK WITH OTHER
TRADES THROUGH THE GENERAL CONTRACTOR AND SHALL BE RESPONSIBLE FOR
SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT CLEARANCE AND CORRECT
ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS.
18. FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A GREEN INSULATED GROUND
CONDUCTOR, SIZE PER NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH
DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS.
PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. MULTIPLE
BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE GROUND CONDUCTOR. SINGLE
GROUND CONDUCTOR IN ONE RACEWAY MUST BE SIZED FOR THE LARGEST OVERCURRENT
DEVICE.
19. REFER TO ONE-LINE DIAGRAM, SCHEDULES AND RISER DIAGRAMS FOR CONDUCTOR AND
CONDUIT SIZES NOT SHOWN ON PLANS.
20. PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE
ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE TO STORE, FURNISH, INSTALL,
MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS
APPURTENANCES REQUIRED TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED
WITHIN THESE DRAWINGS AND SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.
21. DEMOLISH IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE
ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE CONTRACTOR TO DISCONNECT
EQUIPMENT FROM CONNECTIONS, REMOVE FROM THE OWNER'S SITE, AND DISPOSE OF IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND ORDINANCES. COST OF
DISPOSAL IS ENTIRELY THE CONTRACTOR'S RESPONSIBILITY.
22. ALL CONDUCTORS ARE COPPER UNLESS SPECIFICALLY NOTED AS ALUMINUM.
23. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS
BEFORE PROCUREMENT OF ANY MATERIALS AND DEVELOPMENT OF ANY SHOP DRAWINGS
OR SUBMITTALS.
24. THE CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
25. PROVIDE LABELS ON NEW RECEPTACLES, WALL MOUNTED LIGHT SWITCHES/OCCUPANCY
SENSORS AND JUNCTION BOXES INDICATING THE SOURCE PANEL & CIRCUIT(S). TEXT SHALL
BE BLACK, 1/4 ” IN HEIGHT PRINTED ON A CLEAR LABEL. HANDWRITTEN LABELS ARE NOT
PERMITTED.
26. NEW EQUIPMENT AND DEVICES ARE TO BE SURFACE MOUNTED UNLESS OTHERWISE NOTED.
27. DEVICES NOTED AS "GFI" SHALL BE GROUND FAULT CIRCUIT INTERRUPTING DEVICES.
28. DEVICES NOTED AS "WP" SHALL BE WEATHERPROOF WHILE-IN-USE
APPLICABLE CODES AND STANDARDS:
ABBREVIATIONS TITLE EDITION
NFPA 101 LSC LIFE SAFETY CODE (LSC) 2021
NFPA 70 NEC NATIONAL ELECTRICAL CODE (NEC) 2023
P&P 242.1M-ARS ARS FACILITIES DESIGN STANDARDS 2022
IESLL IES LIGHTING LIBRARY STANDARDS COLLECTION 2023
SYMBOL / KEY
REVISION TAG DESIGNATION
DESCRIPTION
TOP DESIGNATION IS SECTION DESIGNATION
KEY NOTE DESIGNATION
BOTTOM DESIGNATION IS SECTION SHEET LOCATION (STANDARD SYMBOL SCALED DOWN FOR LEGEND)
NOTE: ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 WIRE #10AWG CIRCUIT WITH A #10AWG
GND. A GREATER NUMBER OF WIRES IS INDICATED AS FOLLOWS:
4 WIRE, 2 CIRCUITS & GROUND (LONGER SLASH INDICATES NEUTRAL)
6 WIRE, 3 CIRCUITS & GROUND, ETC.(WIRING LARGER THAN #10AWG SHALL BE AS NOTED)
INDICATES #10 GROUND CONDUCTOR UOI (DOUBLE TICK/SLASH INDICATES ISOLATED GROUND)
PANELBOARD AND CIRCUIT DESIGNATION
RACEWAY CONCEALED IN WALL OR CEILING OR EXPOSED ON STRUCTURE AS REQUIRED
HOMERUN TO PANELBOARD - LETTERS INDICATE PANEL, NUMBERS INDICATE CIRCUIT
RACEWAY CONCEALED UNDER FLOOR OR BELOW GRADE. UNDER SLAB APPLICATIONS: RUN BELOW GRAVEL
(NOT ALL SYMBOLS MAY APPLY, TYP.)
NEW WORK LINE WEIGHT
EXISTING WORK LINEWEIGHT
TOP DESIGNATION IS PLAN / ENLARGED PLAN / DETAIL NUMBER
BOTTOM DESIGNATION IS SHEET LOCATION (STANDARD SYMBOL SCALED DOWN FOR LEGEND)
LA1:13
LA1:13
EP101
A
EP101
GENERAL SYMBOLS LEGEND
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
LEGEND AND ABBREVIATIONS
E1 2 808/16/2024
BSN
TMT
DRL
K-MAGEE
T
T
T
X X
X
X
X
X X X X X X X X X X X
X X X X X X
X
X
X
X X
XX
XXXXXXXXXX
X X
X X
X X
X
X X X X X X X X X X X X
X
X X
X X
X X
XXXX
X X
X X
TANK
E
E
E
LP
OEP
O
EP
OEP
OEP
O
EP
O
EP
PP
PP
PP PP
PP
PP
PP
O
EP
O
EP
O
EP
OEP OEP OEP
OEP OEP OEP OEP OEP OEP OEP OEP OEP OEP OEP OEP OEP
PP
PP
PP
SI
G
N
SIGN
SIGN
BLDG
# 47
BLDG
# 59 BL
DG
# 4
7A
BLDG
# 58
BLDG
# 48
OEP
OEP
UE
UE
PP
SHED
X X
X
GATE
BLDG
# 84
BLDG
# 54
MAIN.SWGR
WATER
COOLANT
AREA
GRATE
ELEV.:
120.1
W W
W W
NEW
GREENHOUSE
P.84. SHED
T T
OEP OEP
OEP
O
EP
O
EP
PP
UE
UE
O
EP
O
EP
O
EP
UEUE
UE
UE
E
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
REFER TOE3 FOR WORK IN THIS AREA
EXISTING
GREENHOUSES
SCALE:1"=20'-0"
0 20'20' 10'
SCALE:
SITE PLAN
1" = 20'-0"
E2
KEYED NOTES
GENERAL NOTES
1. PANEL MAIN.SWBD. EXISTING POINT OF SERVICE FOR
84.N and 84.E FEEDERS.
2. BLDG 84 POINT OF CONNECTION FOR 84.N AND 84.E
FEEDERS.
3. DISCONNECT POWER AND REMOVE CONDUCTORS.
ABANDON CONDUIT IN PLACE. CUT CONDUIT FLUSH
WITH GRADE AND CAP.
4. DEMO SWITCH.
5. DEMOLISH THE EXISTING TRANSFORMER.
6. NEW GREENHOUSE PANELS. REFER TO 2/E4.9. PROVIDE
NEW PANELS. REFER TO E6 AND 2/E4 FOR WORK IN
THIS AREA. PROVISION PANELS AS SCHEDULED,
BRANCH CIRCUITS TO BE INSTALLED BY OTHERS.
7. INSTALL NEW POWER POLE WITH NEW POLE MOUNTED
TRANSFORMERS PROVIDING POWER TO NEW
UNDERGROUND SERVICE FEEDERS. REFER TO 1/E4.
8. INSTALL NEW 50KW GENERATOR PROVIDING POWER TO
NEW UNDERGROUND SERVICE FEEDERS.
9. MINIMUM CLEARANCE OF ELECTRICAL CROSSING IS TO
MATCH CLEARANCE OF EXISTING ELECTRICAL
CROSSINGS
1. REVIEW ALL PROJECT DOCUMENTS PRIOR TO START
OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO
CONTRACTING OFFICER PRIOR TO PROCEEDING WITH
WORK. DIMENSIONS RELATING TO EXISTING
CONSTRUCTION ARE TO BE FIELD VERIFIED. THE
CONTRACTOR SHALL IMMEDIATELY COMMUNICATE, IN
WRITING TO THE CONTRACTING OFFICER, CONCERNS
WHERE THEY BELIEVE DESIGN DOCUMENTS ARE
INSUFFICIENT, INADEQUATE OR INCORRECT FOR
PERFORMING THE CONSTRUCTION WORK.
2. EXISTING UNDERGROUND INSTALLATIONS, SUCH AS
WATER MAINS, GAS MAINS, SEWER, TELEPHONE LINES,
FIBER OPTICS, POWER LINES, AND BURIED
STRUCTURES IN THE VICINITY OF THE WORK AREA ARE
INDICATED ON THE DRAWINGS ONLY TO THE EXTENT
SUCH INFORMATION HAS BEEN MADE AVAILABLE TO OR
DISCOVERED BY THE SURVEYOR IN PREPARING THE
DRAWINGS. THERE IS NO GUARANTEE AS TO THE
ACCURACY OR COMPLETENESS THEREOF AND IS
EXPRESSLY DISCLAIMED. THE CONTRACTOR SHALL BE
SOLELY RESPONSIBLE FOR LOCATING ALL EXISTING
UNDERGROUND INSTALLATIONS, INCLUDING SERVICE
CONNECTIONS, IN ADVANCE OF EXCAVATING OR
TRENCHING.
3. OVERHEAD ELECTRICAL LINES MAY ALSO SUPPORT
OTHER OVERHEAD UTILITIES.
4. VERIFY EXISTING CONDITIONS, WHEN SPECIFIC
INFORMATION IS INCORRECT, MISSING OR IS IN
CONFLICT, BRING THE CONFLICT TO THE ATTENTION OF
THE CONTRACTING OFFICER PRIOR TO BEGINNING
WORK RELATED TO THAT ITEM.
5. THE CONTRACTOR SHALL PROVIDE AS-BUILT
DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
SITE LEGEND
EXISTING
LPLP
PP
E
W
GENERATOR
TRANSFORMER
LIGHT POLE
POWER POLE
OVERHEAD POWER
GRAVEL
CONCRETE
ASPHALT
UNDERGROUND POWER
DEMOLITION
WATER
FENCE
OEP
T
U E
U E
U E
U E
U E
U E
U E
U E
U E
U E
UE
UE
OEP
UEUE
NEW
PP
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
SITE PLAN
E2 3 808/16/2024
BSN
TMT
DRL
X
ETR
KEYED NOTES
GENERAL NOTES
LEGEND
EXISTING PANEL
EXISTING HANGING
DUPLEX RECEPTACLE
EXISTING HANGING
QUAD RECEPTACLE
EXISTING WALL MOUNTED
RECEPTACLE
NEW HANGING QUAD
RECEPTACLE. DETAIL 6/E4.
NEW HANGING SINGLE
RECPTACLE. DETAIL 6/E4.
NEW PANEL
1. REPLACE EXISTING 225A PANEL WITH WITH A 400A PANEL
"P.84.N".
2. INSTALL A 100A STANDBY PANEL "P.84.S".
3. INSTALL 3 NEW HANGING QUAD RECEPTACLES AND 3 NEW
HANGING SINGLE RECEPTACLES.
4. DEMOLISH DEVICE. DEMOLISH CONDUCTORS AND CONDUIT
BACK TO SOURCE. CUT FLASH AND PLUG.
5. PROTECT/PRESSURE BRANCH AND FEEDER CIRCUITS FROM
THIS DEVICE FOR REUSE.
6. NEW ATS.
7. EXISTING DEVICES TO REMAIN. REWORK BRANCH CIRCUIT FEED
FROM PANEL P.84.S.
8. EXISTING BLOWER TO REMAIN.REWORK BRANCH CIRCUIT FROM
PANEL P.84.S:2,4.
9. RECONNECT EXISTING BANK CIRCUIT.
1. VERIFY EXISTING CONDITIONS, WHEN SPECIFIC
INFORMATION IS INCORRECT, MISSING OR IS IN
CONFLICT, BRING THE CONFLICT TO THE ATTENTION
OF THE CONTRACTING OFFICER PRIOR TO THE
BEGINNING WORK RELATED TO THAT ITEM.
2. THE CONTRACTOR SHOULD PROVIDE AS-BUILT
DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
3. EXISTING LIGHT FIXTURES, BRANCH CIRCUITRY, AND
CONTROLS TO REMAIN. REROUTE CIRCUIT FROM
EXISTING PANEL TO P.84.S:1.
4. ALL CIRCUITS NOT LISTED TO REMAIN ON P.84.N.
SCALE:
B.84. DEMOLITION
3/16" = 1'-0"
E3
SCALE:
B.84. NEW WORK
3/16" = 1'-0"
E3
0 4' 8' 16'
SCALE: 3/16"= 1'-0"
2'
ETR
ETR
ETR
ETR
P.84.N
TRANSFORMER
T. P.84.N
DISCONNECT
84.E
DISCONNECT
84.N
TRANSFORMER
P.84.S:12
P.84.S:7
P.84.S:9
P.84.S:11
P.84.S:3 P.84.S:10P.84.S:6
P.84.S:8
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
POWER PLAN
E3 4 808/16/2024
BSN
TMT
DRL
ETR
ETR
P.84.S
P.84.N
ETR
ATS. P.84. 6
SPD
P.84.S:26,28,30
SPD
P.84.N:19,21,23
GENERAL NOTES
1. VERIFY EXISTING CONDITIONS, WHEN SPECIFIC
INFORMATION IS INCORRECT, MISSING OR IS IN
CONFLICT, BRING THE CONFLICT TO THE ATTENTION OF
THE CONTRACTING OFFICER PRIOR TO BEGINNING
WORK RELATED TO THAT ITEM.
2. THE CONTRACTOR SHALL PROVIDE AS-BUILT
DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
120v
B
208v
208v
120v 120v
N
C
A
120.0000°
30.0000°
SCALE:
POWER POLE DETAIL
N.T.S.
E4
SCALE:
GREENHOUSE ELECTRICAL EQUIPMENT
MOUNTING DETAIL
N.T.S.
E4
SCALE:
TRENCH DETAIL
N.T.S.
E4
KEYED NOTES:
NEW PVC COATED GALVANIZED RIGID
STEEL CONDUIT. SIZE AS REQUIRED FOR
CONDUCTORS.
NEW NEMA 4XSS ELECTRICAL PANEL
"P.GH.N".
NEW NEMA STANDBY PANEL P.GH.S
NEW C6X8.2 GALVANIZED STEEL CONTROL
PANEL SUPPORT. HOT DIP GALVANIZE
AFTER FABRICATION.
NEW P1001 UNISTRUT
NEW UNDERGROUND POWER SUPPLY.
NEW 24" DIA.x30" DEEP CONCRETE
FOOTINGS FOR NEW CONTROL PANEL
SUPPORT.
PROVIDE GROUNDING BUS BAR
NEW UTILITY PRIMARY
NEW UTILITY POLE
NEW SURGE ARRESTOR
NEW SURGE ARRESTOR AND NEUTRAL GROUND
NEW EQUIPMENT SUPPORT
FUSED CUTOUT
NEW TRANSFORMER
WEATHERHEAD RMC 2"Ø.
BARE COPPER GROUND
RMC 2"Ø.
METER BASE (TYP OF 2)
3/4" X 10' COPPER GROUND ROD
PVC-RMC ADAPTER
SURGE ARRESTOR
FUSED CUTOUT
TRANSFORMER
WEATHERHEAD RMC 2"Ø.
RMC 2"Ø.
1 1
7 7
FINISHED GRADE
COMPACTED METERIAL
MARKER TAPE
CONDUIT(S)
SAND
2" 2"
SCALE:
RECPTACLE DETAIL
N.T.S.
E4
SCALE:
GEN PAD
N.T.S.
S100
(2) #5 BARS CONTINUOUS
3"
1'-4"
1/2" CHAMFER ALL
EXPOSED EDGES
(TYPICAL)
EQUIPMENT PAD
AS SPECIFIED
6"
TURNDOWN
PROVIDE APPROX 8" CLEAR
AROUND ALL EQUIPMENT SIDES
TURN-DOWN (TYP.
ALL SIDES)
UNDISTURBED OR
COMPACTED/STABLE
NATIVE SOIL
QUAD RECEPTACLE
CEILING STRAIN RELIEF
P.GH.N P.GH.S
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
DETAILS
E4 5 808/16/2024
BSN
TMT
DRL
SO CABLE
SINGLE RECEPTACLE
CEILING STRAIN RELIEF
SO CABLE
ATS.GH
1'-6"
SCALE:
NEUTRAL AND GROUNDING DIAGRAM
N.T.S.
E4
MBJ MAIN BONDING JUMPER
SBJ SYSTEM BONDING JUMPER
SSBJ SUPPLY SIDE BONDING JUMPER
EGC EQUIPMENT GROUNDING CONDUCTOR
GEC GROUNDING ELECTRODE CONDUCTOR
NC NEUTRAL CONDUCTOR
GE GROUNDING ELECTRODE
GES GROUNDNG ELECTRODE SYSTEM
ISBT INTERSYSTEM BONDING TERMINATION
EBJ EQUIPMENT BONDING JUMPERS
BJ GROUNDING ELECTRODE SYSTEM BONDING JUMPER
ABBREVIATIONS:
NEW P.84.N (B84)
SE RATED
N
G
N
G
NEW P.84.S (B84)
EBJ
EBJ
TRANSFORMER
MBJ
N
G
BMGB (B84)
2 31
WATER PIPE
(MAIN SERVICE)
BUILDING
STEEL
#4(G), 3/4" PVC C.
#6(G), 3/4" PVC C.
SBB (GH)
WATER PIPE
(MAIN SERVICE)
BUILDING
STEEL
#4(G), 3/4" PVC C.
#6(G), 3/4" PVC C.
3/4"X10' COPPER
CLAD DRIVEN
GROUND ROD
#3/0(G), 1" PVC C.
#3/0 AWG BARE COPPER
GROUDING CONDUCTOR
BURIED 30" BELOW GRADE.
FUTURE BY OTHERS
N
G
NEW ATS.84.S (B84)
EBJ
3/4"X10' COPPER
CLAD DRIVEN
GROUND ROD
#3/0(G), 1" PVC C.
#3/0 AWG BARE COPPER
GROUDING CONDUCTOR
BURIED 30" BELOW GRADE.
N
G
NEW GENERATOR
EBJ
3/4"X10' COPPER
CLAD DRIVEN
GROUND ROD
#3/0(G), 1" PVC C.
#3/0 AWG BARE COPPER
GROUDING CONDUCTOR
BURIED 30" BELOW GRADE.
GEN-G(GH)
GEN-N(GH)
NEW P.84.N (B84)
SE RATED
N
G
N
G
NEW P.84.S (B84)
EBJ
EBJ
MBJ
N
G
NEW ATS.84.S (B84)
EBJ
GEN-N(GH)
GEN-G(GH)
PROVIDE GROUNDING BUSBAR
MINIMUM 4" WIDE AND 1/4"
THICK.4 5 2 31
PROVIDE GROUNDING BUSBAR
MINIMUM 2" WIDE AND 1/4" THICK.
MOUNT 36" ABOVE GRADE.4 5
GROUNDING NOTES
1. PROVIDE CONNECTION TO ANY ADDITIONAL
GROUNDS IN THIS ROOM USING INSULATED #6 AWG
IN 3/4" PVC. C.
2. PROVIDE CONNECTIONS TO HVAC/CRAC UNITS IN
THE ROOM USING INSULATED #6 AWG.
3. PROVIDE CONNECTION TO BUILDING STEEL IF
ACCESSIBLE IN ROOM USING INSULATED #4 AWG.
4. BUSBAR MUST BE TIN PLATED COPPER WITH
PRE-DRILLED HOLES FOR USE WITH TWO-HOLE
COMPRESSION LIGHTS WITH 5/16" OR 7/16" BOLT
HOLES.
5. GROUND CONNECTION TO EXTERIOR GROUND MUST
BE EXOTHERMIC TYPE. ALL OTHER GROUND
CONNECTIONS MUST BE TWO HOLE BOLTED
CONNECTIONS.
SPD SPD
GEN1
100kVA
GEN2
75kVA
UTILITY TFMR
500kVA 480Y/277V
3PH/4W
MAIN
800AF
600AT
2 SETS:
4#500kCMIL
B.
P.
E
0A
F
AT
.P
.E
0A F
AT
A.
P.
ED
P
0A F
AT
.P
.H V1
0A
F
AT
.P
.E
0A F
ATW
0A
F
AT
ED
P2
.N
0A F
5A
T
ED
P1
.N
0A F
0A
T
A.
P.
HV
0A F
5A
T46
0A F
0A
T
.P
.N
0/3
BLDG
BLDG
47A
BLDG
47B
BLDG
BLDG
BLDG
WELL
WO1
BLDG
47C
B.
P.
N
0/3
WELL
WO3
WELL
WO2
WELL
WO4
.P
.N
0/3
B
0/3 47
C
0/2
175/3
RK1
B.
P.
E
0A
F
ATEL
0A F
AT
SP
AR
E
0/3 SP
D
0/3
MAIN.SWBD -480Y/277V, 3PH, 4WI, 1200AF, 35KAIC OUTSIDE CONSTRUCTION
E N E N E N E N N N E N E NE ENN
MAIN.SWBD.MDP - 1200A BUSMAIN.SWBD.EDP2 - 400A PANELBOARDMAIN.SWBD.EDP1 - 400A PANELBOARD
.P
.A
5/3
.P
.B
0/3
47B.P.NH 400AF
W
0/3
48.P.N 400AF
W 02 60 /3
.P
.A
/3
47B.P.NL 250AF
15kVA
EL
100/3
EL
SP
AR
E
0A F
AT
.P
.N
0/3
SP
D
/3
SP
D
/360kVA
208V 3P/4W
175/3
RK1
GE
N2
.IN
0A F
5A
T
GE
N1
.IN
0A F
5A
T
BLDG
N
E
KEYED NOTES
1. DISCONNECT E AND N FOR BUILDING 84.
1. VERIFY EXISTING CONDITIONS, WHEN SPECIFIC
INFORMATION IS INCORRECT, MISSING OR IS IN
CONFLICT, BRING THE CONFLICT TO THE ATTENTION
OF THE CONTRACTING OFFICER PRIOR TO THE
BEGINNING WORK RELATED TO THAT ITEM.
2. THE CONTRACTOR SHOULD PROVIDE AS-BUILT
DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
EXISTING SINGLE LINE
E5 6 808/16/2024
BSN
TMT
DRL
GENERAL NOTES
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
SINGLE LINE
E6 7 808/16/2024
BSN
TMT
DRL
325/3
LSI100/330/3
SPD
TYPE #2
100A4NG
'P.84.N', NEMA 1 400AF 325AT -208Y/120V, 3PHASE, 4WIRE, 22kAIC
50A2G
BLOWER
100A4NG
ATS-84
208V,100A 3P, 22kAIC
100/3
LSI
'P.84.S', NEMA 1 100A-208Y/120V, 3PHASE, 4WIRE, 22AIC
100A4NG
SPD
TYPE #2
30A4NG
T-UTIL
UTIL
350A4
100A4NG
50KW GENERATOR
200/3
LSI 60/3
'P.GH.N', NEMA 3R 225AF 200AT -208Y/120V, 3PHASE, 4WIRE, 22kAIC 200A4
60A4NG
60A4NG
ATS-GH
208V,60A 3P, 22kAIC
60A
MCB
208V
P.GH.S
60A4NG
COPPER FEEDER SCHEDULE
KEY
QTY.
OF
RUNS
CONDUCTORS C
(IN)
200A4 1 4#3/0 2-1/2 350A4 1 4#500 3-1/2
50A2G 1 2#6,1#10G 1
30A4NG 1 3#8,1#6N,1#8G 1
60A4NG 1 3#4,1#1N,1#10G 1-1/2
100A4NG 1 3#1/0,1#250N,1#4G 2-1/2
GBJ
REFER TO GROUNDING
AND BONDING JUMPER
SCHEDULE
XFMR REFER TO XFMR
SCHEDULE
REFER TO NATIONAL ELECTRICAL CODE FOR
INSTALLATION OF CONDUIT TYPE.
ALL CONDUCTORS ARE COPPER.
50/2 30/3
M M
GENERAL NOTES
1. VERIFY EXISTING CONDITIONS, WHEN SPECIFIC
INFORMATION IS INCORRECT, MISSING OR IS IN
CONFLICT, BRING THE CONFLICT TO THE ATTENTION
OF THE CONTRACTING OFFICER PRIOR TO THE
BEGINNING WORK RELATED TO THAT ITEM.
2. THE CONTRACTOR SHOULD PROVIDE AS-BUILT
DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
3. COORDINATE METERING REQUIREMENTS WITH UTILITY.
30/3
SPD
TYPE #2
30A4NG
SPD
TYPE #2
Panel Name: P.84.N MLO or Main C.B.:MCB Panel Location: B.84. Surface or Flush:SURFACE
Voltage: 120/208V Frame Amps:225 Phase/Wire: 3PH/4W Grounding:EQUIPMENT GROUND
Minimum Interrupting Rating: 225A Sections:ONE SECTION - 30X New/Existing: Existing Nema Rating:NEMA 1
Load VA Branch Load Data Breaker Breaker Branch Load Data Load VA Ph A Ph B Ph C Trip Pole No. Ph. No. Trip Pole Ph A Ph B Ph C
THREE PHASE LOAD - LHS 125 6
1 a 2 20 1 SPACE 3 b 4 20 1 SPACE 5 c 6 20 1 SPACE 7 a 8 20 1 SPACE 9 b 10 60 2 LIGHTS11 c 12
R - N WALL 20 1 13 a 14 20 1 EMERGENCY LIGHTS R - N WALL 20 1 15 b 16 30 1 OUTSIDE BLOWER R - E WALL 20 1 17 c 18 20 1 FAN
SPD 100 3
19 a 20 20 1 E LIGHTS 21 b 22 20 1 W LIGHTS 23 c 24 20 1 SPARE
R - S WALL 20 1 25 a 26 20 1 R - SOUTH WALL GATE 20 1 27 b 28 20 1 SPARE SPACE 20 1 29 c 30 20 1 SPARE
Panel Name: P.84.N MLO or Main C.B.:MCB Panel Location: B.84. Surface or Flush:SURFACE
Voltage: 120/208V Frame Amps:325 Phase/Wire: 3PH/4W Grounding:EQUIPMENT GROUND
Minimum Interrupting Rating: 325A Sections:ONE SECTION - 42X New/Existing: New Nema Rating:NEMA 1
Load VA Branch Load Data Breaker Breaker Branch Load Data Load VA Ph A Ph B Ph C Trip Pole No. Ph. No. Trip Pole Ph A Ph B Ph C
EXISTING LOAD 125 6
1 a 2 100 3 P.B84.S3 b 4
5 c 6 7 a 8 20 1 SPACE 9 b 10 60 2 LIGHTS11 c 12
R - N WALL 20 1 13 a 14 20 1 EMERGENCY LIGHTS R - N WALL 20 1 15 b 16 30 1 OUTSIDE BLOWER R - E WALL 20 1 17 c 18 20 1 FAN
SPD 100 3
19 a 20 20 1 E LIGHTS (1) 21 b 22 20 1 W LIGHTS (1) 23 c 24 20 1 SPARE
R - S WALL 20 1 25 a 26 20 1 R - SOUTH WALL GATE 20 1 27 b 28 20 1 SPARE SPACE 20 1 29 c 30 20 1 SPARE SPACE 20 1 31 a 32 20 1 SPARE SPACE 20 1 33 b 34 20 1 SPARE SPACE 20 1 35 c 36 20 1 SPACE SPACE 20 1 37 a 38 20 1 SPACE SPACE 20 1 39 b 40 20 1 SPACE SPACE 20 1 41 c 42 20 1 SPACE
P.84.N EXISTING PANEL SCHEDULE
P.84.N NEW PANEL SCHEDULE
P.84.S NEW PANEL SCHEDULE
GENERAL NOTES
1. VERIFY EXISTING CONDITIONS, WHEN SPECIFIC
INFORMATION IS INCORRECT, MISSING OR IS IN
CONFLICT, BRING THE CONFLICT TO THE ATTENTION
OF THE CONTRACTING OFFICER PRIOR TO THE
BEGINNING WORK RELATED TO THAT ITEM.
2. THE CONTRACTOR SHOULD PROVIDE AS-BUILT
DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
JAMIE WHITTEN DELTA STATES RESEARCH CENTER
HATCHERY COMPLEX ELECTRICAL ADDITION
STONEVILLE, MS
PANEL SCHEDULES
E7 8 808/16/2024
BSN
TMT
DRL
Panel Name: P.GH.N MLO or Main C.B.: MCB Panel Location: GH Surface or Flush: SURFACE
Voltage: 120/208V Frame Amps: 225 Phase/Wire: 3PH/4W Grounding: EQUIPMENT GROUND
Minimum Interrupting Rating: 200A Sections: ONE SECTION - 30X New/Existing: New Nema Rating: NEMA 4X
Load VA LOAD
Co nt
No tes Branch Load Data Wire Breaker Breaker
No tes Wire Branch Load Data
Co nt
# LOAD Load VA Ph A Ph B Ph C TYPE Trip Pole No. Ph. No. Trip Pole TYPE Ph A Ph B Ph C
P.GH.S 60 3
1 a 2 20 1 SPARE 3 b 4 20 1 SPARE 5 c 6 20 1 SPARE
SPARE 20 1 7 a 8 20 1 SPARE SPARE 20 1 9 b 10 20 1 SPARE SPARE 20 1 11 c 12 20 1 SPARE SPARE 20 1 13 a 14 20 1 SPARE SPARE 20 1 15 b 16 20 1 SPARE SPARE 20 1 17 c 18 20 1 SPARE SPARE 20 1 19 a 20 20 1 SPARE SPARE 20 1 21 b 22 20 1 SPARE SPARE 20 1 23 c 24 20 1 SPARE SPARE 20 1 25 a 26
30 3 SPDSPARE 20 1 27 b 28 SPARE 20 1 29 c 30
Panel Name: P.GH.S MLO or Main C.B.: MCB Panel Location: GH Surface or Flush: SURFACE
Voltage: 120/208V Frame Amps: 60 Phase/Wire: 3PH/4W Grounding: EQUIPMENT GROUND
Minimum Interrupting Rating: 60A Sections: ONE SECTION - 18X New/Existing: New Nema Rating: NEMA 4X
Load VA LOAD
Co nt
No tes Branch Load Data Wire Breaker Breaker
No tes Wire Branch Load Data
Co nt
# LOAD Load VA Ph A Ph B Ph C TYPE Trip Pole No. Ph. No. Trip Pole TYPE Ph A Ph B Ph C
SPARE 20 1 1 a 2 20 1 SPARE SPARE 20 1 3 b 4 20 1 SPARE SPARE 20 1 5 c 6 20 1 SPARE SPARE 20 1 7 a 8 20 1 SPARE SPARE 20 1 9 b 10 20 1 SPARE SPARE 20 1 11 c 12 20 1 SPARE SPARE 20 1 13 a 14
30 3 SPDSPARE 20 1 15 b 16 SPARE 20 1 17 c 18
Panel Name: P.84.S MLO or Main C.B.:MCB Panel Location: B.84. Surface or Flush:SURFACE
Voltage: 120/208V Frame Amps:100 Phase/Wire: 3PH/4W Grounding:EQUIPMENT GROUND
Minimum Interrupting Rating: 100A Sections:ONE SECTION - 24X New/Existing: New Nema Rating:NEMA 1
Load VA Branch Load Data Breaker Breaker Branch Load Data Load VA Ph A Ph B Ph C Trip Pole No. Ph. No. Trip Pole Ph A Ph B Ph C 441 LIGHTING (1) 20 1 1 a 2 50 2 BLOWER (1) 182
1398 UV/PUMP 20 1 3 b 4 182 SPARE 20 1 5 c 6 20 1 HEATER (1) 1800
1800 HEATER 20 1 7 a 8 20 1 HEATER (1) 1800 1800 HEATER 20 1 9 b 10 20 1 UV&PUMP (1) 1398
1800 HEATER 20 1 11 c 12 20 1 UV/PUMP 699 SPARE 20 1 13 a 14 20 1 SPARE SPARE 20 1 15 b 16 20 1 SPACE SPARE 20 1 17 c 18 20 1 SPACE SPACE 20 1 19 a 20 20 1 SPACE SPACE 20 1 21 b 22 20 1 SPACE SPACE 20 1 23 c 24 20 1 SPACE SPACE 20 1 25 a 26
30 3 SPDSPACE 20 1 27 b 28 SPACE 20 1 29 c 30
P.GH.N NEW PANEL SCHEDULE
P.GH.S NEW PANEL SCHEDULE
| Sheets and Views |
| T1 |
| E1 |
| E2 |
| E3 |
| E4 |
| E5 |
| E6 |
| E7 |
File details come from the government source that posted it. Updated .