About this file
This document is a Confined Space Assessment Inventory that catalogues identified confined spaces across three federal facilities: BARC (Beltsville Agricultural Research Center), BHNRC (Beltsville Human Nutrition Research Center), and USNA (United States Naval Academy).
The BARC facility assessment identifies 25 confined space deficiencies across multiple buildings and exterior areas, primarily involving utility vaults, mechanical rooms, boiler spaces, crawlspaces, and catch basins. The vast majority require immediate signage installation, with 20 items rated High priority and 4 rated Medium priority. Critical deficiencies include an unsecured manure pit (BARC-CS-025) requiring immediate securing, an unsecured utility vault with open cover (BARC-CS-018), and damaged stormwater catch basin with gap cover (BARC-CS-020). Space types are classified as either Permitted Confined Spaces (PRCS) or Non-Permitted Confined Spaces (NPCS), with identified hazard types including atmospheric, engulfment, thermal, electrical, fall, and slip hazards. Several locations require standardized signage due to inconsistent labeling. The BHNRC facility assessment is minimal, with only one low-priority action required: removal of incorrect signage in Building 307C's elevator machine room. The USNA facility assessment identifies 58 confined space deficiencies, with 55 catch basins in the NACB Inventory requiring standardized signage installation, all classified as NPCS with water/slip hazards. Three additional deficiencies in Building 19 require signage installation and one requires immediate securing of an unsecured mechanical pit opening. All items are marked "Open" status under Facilities management, indicating pending action.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ID Site Building/Area Location Description Space Type Confined SClassification Signage Status Condition Hazard Type Deficiency Recommendation Priority Action Owner Status BARC-CS-001 BARC Building 003 Exterior Front Lawn Utility Vault Yes PRCS Missing Needs Attention Atmospheric/Fall Not labeled Install signage High Facilities Open BARC-CS-002 BARC Building 003 Rooms 405/018/007 Mechanical Rooms No Not CS Incorrect Good N/A Incorrect signage Remove signage Low Safety Open BARC-CS-003 BARC Building 004 Rear Exterior Utility Vault Yes PRCS Missing Needs Attention Atmospheric/Fall Not labeled Install signage High Facilities Open BARC-CS-004 BARC Building 004 Interior Rooms Mechanical Rooms No Not CS Incorrect Good N/A Incorrect signage Remove signage Low Safety Open BARC-CS-005 BARC Building 014 Boilers/Basement/Exterior Multiple PRCS Yes PRCS Mixed Needs Attention Multiple Inconsistent labeling Standardize signage High Facilities Open BARC-CS-006 BARC Building 015 Water Storage Tanks Tank Yes PRCS Missing Needs Attention Atmospheric/Engulfment Not labeled Install signage High Facilities Open BARC-CS-007 BARC Building 006 Exterior Pits Utility Pits Yes PRCS Missing Good Atmospheric Not labeled Install signage High Facilities Open BARC-CS-008 BARC Building 006 Attic Mechanical Space No Not CS Incorrect Good N/A Incorrect signage Remove signage Low Safety Open BARC-CS-009 BARC Building 010 Exterior Pits + Room M1 Pits/Utility Space Yes PRCS Missing Needs Attention Atmospheric/Slip Not labeled Install signage High Facilities Open BARC-CS-010 BARC Building 307 Room 024 Tunnel Steam Tunnel Yes PRCS Missing Wet Thermal/Slip Not labeled Install signage High Facilities Open BARC-CS-011 BARC Building 307 Rooms 015/016 Crawlspaces Yes NPCS Missing Good Restricted Access Not labeled Install signage Medium Facilities Open BARC-CS-012 BARC Building 306 Basement Rooms Crawlspaces Yes PRCS Missing Wet Atmospheric/Slip Not labeled Install signage High Facilities Open BARC-CS-013 BARC Building 434 Front/Rear Vaults Utility Vaults Yes PRCS Missing Good Atmospheric Not labeled Install signage High Facilities Open BARC-CS-014 BARC Building 426 Boiler Room Boiler Space Yes PRCS Missing Wet Thermal/Slip Not labeled Install signage High Facilities Open BARC-CS-015 BARC 1st Street Multiple Vaults Utility Vaults Yes PRCS Missing Mixed Atmospheric Not inventoried Add signage + inventory High Facilities Open BARC-CS-016 BARC South Drive Vaults Utility Vaults Yes PRCS Missing Good Atmospheric Not inventoried Add signage High Facilities Open BARC-CS-017 BARC 3rd Street Vaults/Manholes Utility Vaults Yes PRCS Partial Mixed Atmospheric Inconsistent labeling Standardize High Facilities Open BARC-CS-018 BARC Building 012 Exterior Vault Utility Vault Yes PRCS Missing Unsecured Atmospheric/Fall Open cover Secure + signage High Facilities Open BARC-CS-019 BARC Shop Drive Field Vault Utility Vault Yes PRCS Missing Good Atmospheric Not labeled Install signage High Facilities Open BARC-CS-020 BARC Range 2 Drive Catch Basins Stormwater Yes PRCS Missing Needs Repair Atmospheric Gap cover Repair + signage High Facilities Open BARC-CS-021 BARC Building 310 Tunnel/Boilers/Vault Multiple Yes PRCS Missing Wet Multiple Not labeled Install signage High Facilities Open BARC-CS-022 BARC Building 309 Manhole/Electric Vault Utility Structures Yes PRCS Missing Good Electrical/Atmospheric Not labeled Install signage High Facilities Open BARC-CS-023 BARC Powder Mill Rd Sewer Manhole Manhole Yes PRCS Missing Good Atmospheric Not labeled Install signage High Facilities Open BARC-CS-024 BARC Building 218 Treatment Area Multiple PRCS Yes PRCS Missing Open Hazard Atmospheric/Engulfment Not labeled Install signage High Facilities Open BARC-CS-025 BARC Building 178-2 Manure Pit Wet Well Yes PRCS Missing Open Hazard Atmospheric/Engulfment Open pit Secure immediately High Facilities Open
BARC W
es t-E as t C am pu s
ID Site Building/Area Location Description Space Type Confined Space Classification Signage Status Condition Hazard Type Deficiency Recommendation Priority Action Owner Status BHNRC-CS-001 BHNRC Building 307B Entire Building N/A No Not CS N/A Good N/A None No action requried Low Safety Open BHNRC-CS-001 BHNRC Building 307C Elevator Machine Room Basement Mehanical Room No Not CS Incorrect Good N/A Incorrect Signage Remove Signage Low Safety Open BHNRC-CS-001 BHNRC Building 307C All Other Areas N/A No Not CS N/A Good N/A None No action requried Low Safety Open
BHNRC
ID Site Building/Area Location Description Space Type Confined Space Classification Signage Status Condition Hazard Type Deficiency Recommendation Status USNA-CS-001 USNA Building 19 Room 118 – Crawl Space Crawl Space Yes PRCS Missing Needs Attention Atmospheric Not labeled Install signage Open USNA-CS-002 USNA Building 19 Room 120A – Ceiling Crawl Space Crawl Space Yes PRCS Missing Needs Attention Atmospheric/Low Visibility Not labeled Install signage Open USNA-CS-003 USNA Building 19 Room 038 – Mechanical Pit Utility Pit Yes PRCS Missing Critical Atmospheric/Fall Unsecured opening Secure + signage Open USNA-CS-004 USNA NACB Inventory Catch Basin #1 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-005 USNA NACB Inventory Catch Basin #2 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-006 USNA NACB Inventory Catch Basin #3 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-007 USNA NACB Inventory Catch Basin #4 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-008 USNA NACB Inventory Catch Basin #5 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-009 USNA NACB Inventory Catch Basin #6 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-010 USNA NACB Inventory Catch Basin #7 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-011 USNA NACB Inventory Catch Basin #8 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-012 USNA NACB Inventory Catch Basin #9 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-013 USNA NACB Inventory Catch Basin #10 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-014 USNA NACB Inventory Catch Basin #11 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-015 USNA NACB Inventory Catch Basin #12 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-016 USNA NACB Inventory Catch Basin #13 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-017 USNA NACB Inventory Catch Basin #14 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-018 USNA NACB Inventory Catch Basin #15 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-019 USNA NACB Inventory Catch Basin #16 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-020 USNA NACB Inventory Catch Basin #17 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-021 USNA NACB Inventory Catch Basin #18 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-022 USNA NACB Inventory Catch Basin #19 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-023 USNA NACB Inventory Catch Basin #20 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-024 USNA NACB Inventory Catch Basin #21 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-025 USNA NACB Inventory Catch Basin #22 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-026 USNA NACB Inventory Catch Basin #23 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-027 USNA NACB Inventory Catch Basin #24 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-028 USNA NACB Inventory Catch Basin #25 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-029 USNA NACB Inventory Catch Basin #26 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-030 USNA NACB Inventory Catch Basin #27 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-031 USNA NACB Inventory Catch Basin #28 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-032 USNA NACB Inventory Catch Basin #29 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-033 USNA NACB Inventory Catch Basin #30 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-034 USNA NACB Inventory Catch Basin #31 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-035 USNA NACB Inventory Catch Basin #32 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-036 USNA NACB Inventory Catch Basin #33 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-037 USNA NACB Inventory Catch Basin #34 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-038 USNA NACB Inventory Catch Basin #35 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-039 USNA NACB Inventory Catch Basin #36 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-040 USNA NACB Inventory Catch Basin #37 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-041 USNA NACB Inventory Catch Basin #38 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-042 USNA NACB Inventory Catch Basin #39 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-043 USNA NACB Inventory Catch Basin #40 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-044 USNA NACB Inventory Catch Basin #41 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-045 USNA NACB Inventory Catch Basin #42 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-046 USNA NACB Inventory Catch Basin #43 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-047 USNA NACB Inventory Catch Basin #44 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-048 USNA NACB Inventory Catch Basin #45 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-049 USNA NACB Inventory Catch Basin #46 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-050 USNA NACB Inventory Catch Basin #47 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-051 USNA NACB Inventory Catch Basin #48 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-052 USNA NACB Inventory Catch Basin #49 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-053 USNA NACB Inventory Catch Basin #50 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-054 USNA NACB Inventory Catch Basin #51 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-055 USNA NACB Inventory Catch Basin #52 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-056 USNA NACB Inventory Catch Basin #53 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-057 USNA NACB Inventory Catch Basin #54 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open USNA-CS-058 USNA NACB Inventory Catch Basin #55 Catch Basin Yes NPCS Missing Verified Water/Slip No signage Install signage Open
USNA
| BARC West-East Campus |
| BHNRC |
| USNA |
File details come from the government source that posted it. Updated .