Onsite Evaluation Report – A. Macy – 9044 Palmer Way, Warm Springs, OR
Completed by Darcey Jones, IHS, Project Manager
Test Pit Evaluation – Conducted July, 2020:
Overview:
The IHS proposes to construct an equal distribution drainfield system and community water connection to the home. On July 09, 2020, suitable soil for an on-site individual septic system was found near the
West side of the property. Two out of Five test pits were limited at around 21-inches by bedrock and no signs of a seasonal water table were evident.
New Home Details:
4 BDRM – 2.5 BA w/ 3 occupants
Design Flow = 450 GPD (OAR 340-071-0220 Table 1)
Site Plan: Attached
Test Pit #1- Not suitable for drainfield
0”-22” Soil Group B – Sandy Loam
22”-43” Soil Group A – Loamy Sand
43”-62” Soil Group B – Sandy Loam
Limiting Layer was found at 21”
Allowable Trench Depth – 21”
Effective Soil Depth – 18” min. 21 max.
Test Pit #2- Not suitable for drainfield
0”-22” Soil Group B - Clay Loam
22”-39” Soil Group B – Sandy Loam
39”-69” Soil Group B – Sandy Loam
Limiting Layer was found at 42”
Allowable Trench Depth- 18”min 36”max
Effective Soil Depth – 24”-36” Bedrock Limited
Test Pit #3
0-39” Soil Group C – Clay 39”-72” Soil Group B – Clay Loam No limiting layer was present Effective Soil Depth – 24”-36”
Test Pit #4
0-48” Soil Group C - Clay 48”-72” Soil Group B – Sandy Clay Loam No limiting layer was present Effective Soil Depth – 48” or more
Test Pit #5 – Suitable Soil Approval Area
0”-44” Soil Group B – Loam 44”-70” Soil Group B – Loam No limiting layer was present Allowable Trench Depth- 18”min 36”max Effective Soil Depth – 48” or more
STDF Site Approval NEAR TEST PIT #5:
Home Size: 4BDRM/2.5 BA
Design Flow = 450 gpd
Required Septic Tank Volume = 1,500 gallons
Allowable Trench Depth: 18”min 36”max
Effective Soil Depth: 48” or more
Soil Group B – Loam
Required Minimum Drainfield Length = 375LF
Narrative Approval: Construct an equal distribution conventional drainfield (375LF) in accordance with
Oregon Administrative Rules On-site Wastewater Individual Septic System.
Site Photos:
Figure 1Test Pit #5 (Approved drainfield area)