Attachment 2 - Statement Of Objectives.pdf
PDF 1 MB Posted
- Attached to
- 307th Fall Restraint System
- Solicitation number
- FA460824QC055
About this file
This document is a Statement of Objectives (SOO) for a federal contract opportunity to design and install two (2) Fall Arrest Systems in Building 6604, Hanger 1 at Barksdale Air Force Base, Louisiana. The key objectives are to design and install two code-compliant Fall Arrest Systems that cover the working area of the wingspan of a B-52 using an overhead, enclosed dual rail track system capable of supporting three simultaneous users per wing. The contractor is responsible for ensuring the existing structure can support the load, providing as-built drawings, and performing annual inspections and certifications for a minimum of ten years. This contract opportunity is a total small business set-aside with a North American Industry Classification System (NAICS) code of 333923 and a size standard of 1,250 employees. Quotes are due by 12:00 PM CDT on September 3, 2024, and a site visit is scheduled for August 21, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 - Provisions and Clauses.pdf | ||
| Combined Synopsis-Solicitation - FA460824QC055.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF OBJECTIVES (SOO)
Project: 307 AMXS Fall Restraint System, Building 6604, Hanger 1
1.0 Purpose: Install two (2) Fall Arrest Systems in Building 6604, Hanger 1 in accordance with (IAW) the Occupational Safety and Health Administration (OSHA) standards.
2.0 Scope or Mission: Design and install two (2) code compliant Fall Arrest Systems that covers the working area of the wingspan of a B-52 using an overhead, enclosed dual rail track system capable of supporting three (3) simultaneous users or the equivalent per wing. The fall arrest system shall be a mechanical installation using a bolt on application.
3.0 Period and Place of Performance: 817 Lindberg Road, Barksdale Air Force Base, Louisiana, 71110; Building 6604, Hanger 1; Timeframe as soon as possible.
4.0 Background: The 307th Aircraft Maintenance Squadron (307 AMXS) does not have an existing Fall Arrest System.
5.0 Performance Objectives:
o Design two (2) code compliant Fall Arrest Systems and submit for approval to 307 AMXS and 2d Civil Engineering Squadron (2 CES). Any proposed structural modification(s) must be clearly identified in the design plan and must be approved by 2 CES.
o Submit approved scaled drawings/design plan stamped by a licensed engineer in the State of Louisiana for review and approval to 307 AMXS and 2 CES before installation begins.
o It is the responsibility of the contractor to ensure the existing structure is sufficient to support the load of the two (2) Fall Arrest Systems.
o Supply and install two (2) code compliant Fall Arrest Systems. Both systems must be certified pending final testing and inspection.
o Timely submission of deliverables is essential to successful completing this requirement.
o Provide means of secondary attachment (i.e. safety cable or equivalent) to safeguard against collapse o Safeguarding all government property.
o Reattachment of bird netting that is removed to facilitate Fall Arrest Systems install.
o No later than (NLT) 30 days after conclusion of the project, provide one (1) hard copy and one (1) digital copy of as-built drawings to 307 AMXS and 2 CES.
o Provide the annual inspection and certification of the two (2) Fall Arrest Systems for a minimum of ten (10) years.
6.0 Operating Constraints:
o All work must be scheduled ahead of time with the 2 AMXS POC. Every attempt possible to “stay on schedule” needs to be adhered to.
o All materials must be on hand before work commences.
o Hanger is located on an active base with security requirements to gain access.
o No work/installation/assembly of the fall protection system will be performed at any time above a parked aircraft.
o Safety signage and barricades shall be provided and kept in place by the contractor for the entirety of installation.
FA460824QC055
Attachment 2
File details come from the government source that posted it. Updated .