Attachment 2 Signed and Sealed Drawings Replace ICU and 200N Roofs.pdf
PDF 5 MB Posted
- Solicitation number
- 36C24224B0027
About this file
This document is a Solicitation for the replacement of the Building 200ICU roof (approximately 7,000 sq.ft.) and Building 200N flat roof (approximately 14,000 sq.ft.) at the Northport VA Medical Center. The project includes furnishing all necessary professional construction services to replace the roofs, including new roofing systems, flashing, insulation, drainage, and lightning protection. Key details include:
The scope of work involves removing the existing roofing systems down to the decking, installing new TPO roofing systems with tapered insulation, new flashing, and new roof drainage. All work must be coordinated with the Contracting Officer Representative to maintain operations at the occupied medical center. The project is expected to take up to 400 calendar days and be completed in 4 phases. The contractor must utilize the VA's Autodesk Build Construction management platform for all project communications and document management. There are various safety, security, quality control, and records management requirements the contractor must comply with. The solicitation number is 36C24224B0027 and the project number is 632-21-118.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
TITLE SHEET & DRAWING INDEX FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GI001
632-21-118
JPK CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
REPLACE ICU AND 200 NORTH
ROOFS
ICU
PARKING
LOT L
KEYPLAN
200N
PARKING LOT L
STAGING AREA
BUILDING 200
ICU
BUILDING 200N
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
NORTHPORT VAMC
AutoCAD SHX Text
79 MIDDLEVILLE ROAD NORTHPORT, NY 11768
AutoCAD SHX Text N
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
NOTES AND LEGENDS FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GI002
632-21-118
JPK CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
ROOF DRAIN
VENT PIPE
VENTILATION HOOD WITH CURB
ROOF OR SMOKE HATCH
ARCHITECTURAL GENERAL NOTES:
1. THE CONTRACTOR SHALL COORDINATE ALL WORK ASSOCIATED WITH THIS PROJECT WITH THE SUB-CONTRACTORS, TO
PROVIDE A COMPLETE AND FINISHED PROJECT.
2. THIS FACILITY IS OCCUPIED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF
CONSTRUCTION AND SHALL BE RESPONSIBLE TO THE VA COR FOR PROVIDING A SAFE WORK ENVIRONMENT DURING THE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL ENSURE THE SAFETY OF PATIENTS AND VA STAFF IS NOT
COMPROMISED DUE TO ANY CONSTRUCTION RELATED ACTIVITIES.
3. ALL MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND
RECOMMENDATIONS.
4. DIMENSIONS AND DETAILS ARE BASED ON THE BEST AVAILABLE INFORMATION AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIELD DIMENSIONS BEFORE ORDERING MATERIALS AND PREFABRICATED ITEMS.
5. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CONTRACTOR SKILLED IN THEIR
RESPECTIVE TRADES.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING AND CORRECTING HIS/HER OWN WORKMANSHIP.
7. ALL WORKMANSHIP AND MATERIALS, UNLESS CARRYING A GUARANTEE BY A MANUFACTURER FOR A LONGER PERIOD
OF TIME SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR PER CONTRACT AND FAR REGULATIONS AS STIPULATED
BY THE CONTRACTING OFFICER.
8. THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY FIELD CONDITIONS.
9. THE CONTRACTOR SHALL MAKE EVERY EFFORT TO PREVENT THE SPREAD OF DUST, SMOKE, FUMES, ETC., THROUGHOUT THE BUILDING AND NEIGHBORHOOD. PROTECT ALL AIR INTAKES WITH CHARCOAL FILTERS FOR ROOF
APPLICATIONS.
10. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY SERVICES INCLUDING, ADEQUATE LIGHTING, WATER, TOILETS, POWER, HEAT, ETC. AS REQUIRED FOR WORKMAN, MATERIAL INSTALLATION, WORK PROTECTION, ETC. OR AS
DISCUSSED AND ALLOWED BY THE VA COR.
11. THE CONTRACTOR SHALL PROVIDE THE VA COR A COMPLETE MAINTENANCE & OPERATIONAL INSTRUCTIONS IN BOTH
WRITTEN & VERBAL FORM FOR ALL CONTRACTOR PROVIDED EQUIPMENT.
12. THE CONTRACTOR SHALL REVIEW ALL CONSTRUCTION DOCUMENTS AND NOTIFY THE VA COR OF ANY INACCURACIES OR DISCREPANCIES IN THE DOCUMENTS AND IN FIELD CONDITIONS SHOWN ON THE DRAWINGS IN A TIMELY MANNER.
13. THE CONTRACTOR SHALL PERFORM ALL WORK IN STRICT ACCORDANCE WITH ALL FEDERAL CODES, RULES, REGULATIONS AND ORDINANCES INCLUDING, BUT NOT LIMITED TO, THE INTERNATIONAL ENERGY CONSERVATION CODE, THE INTERNATIONAL BUILDING CODE, AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) WHETHER OR
NOT INFORMATION AND/OR WORK IS SPECIFICALLY SHOWN ON THE DRAWINGS.
14. THE CONTRACTOR SHALL BE AWARE THAT THE EXISTING FACILITY HAS THE POTENTIAL OF HAVING OTHER
CONSTRUCTION PROJECTS GOING ON AT THE SAME TIME. COORDINATE WITH VA COR.
15. THE CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL MATERIAL DELIVERIES WITH VA COR AND VA STAFF IN CHARGE OF THE LOADING DOCK. NO CONTRACTOR MATERIAL WILL BE STORED ON OR AROUND LOADING DOCK UNLESS
AUTHORIZED BY THE VA COR. THE VA WILL NOT RECEIVE CONTRACTOR MATERIAL.
16. CONTRACTOR TO PROVIDE MULTIPLE CHUTES TO CONVEY CONSTRUCTION WASTE FROM ROOF DOWN TO GROUND LEVEL. CONTRACTOR TO PROVIDE TEMPORARY WASTE RECEPTACLES UNDER OUTPUT OF CHUTES TO TRANSPORT WASTE BETWEEN CHUTES AND DUMPSTER. PROTECT ALL AREAS THAT TEMPORARY WASTE RECEPTACLES TRAVERSE.
WASTE SHALL NOT PILE UP ON LOWER ROOFS OR GROUND. IMMEDIATELY RELOCATE WASTE TO DUMPSTER. NO
CHUTES ARE ALLOWED FOR ASBESTOS CONTAINING MATERIAL.
17. STOCK PILING OF NEW ROOFING MATERIALS ON EXISTING AND NEW ROOF AREAS IS NOT PERMITTED.
18. ALL WOOD BLOCKING SHALL BE PRESSURE TREATED AND FIRE RETARDANT WITH STAMP SHOWN.
19. CONTRACTOR SHALL SUBMIT A PLAN TO THE COR WITHIN 10 CALENDAR DAYS OF THE NTP FOR EACH OF THE
FOLLOWING: STAGING AREA IN PARKING LOT L AS WELL AS THE SCAFFOLDING, ELECTRIC WINCH HOIST, DUMPSTER
AND CHUTE AREA FOR EACH PHASE OF WORK.
20. CONTRACTOR TO PROVIDE FIRE PREVENTION PLAN TO VA COR FOR REVIEW AND APPROVAL.
21. ALL LIFE-SAFETY SYSTEMS SHALL REMAIN OPERATIONAL THROUGHOUT THE DURATION OF THE PROJECT. ANY
INTERRUPTION OF THE LIFE-SAFETY SHALL BE COORDINATED WITH THE COR AHEAD OF TIME.
22. THE CONTRACTOR WILL FOLLOW THE REQUIREMENTS SPELLED OUT ON THE HOT WORK PERMIT AND SAFETY
PROTOCOLS WHILE PERFORMING HOT WORK.
23. CONTRACTOR SHALL SUBMIT SCAFFOLDING SHOP DRAWINGS FOR EACH LOCATION SIGNED AND SEALED BY A PE. EACH
DRAWING IS TO BE SIGNED AND SEALED.
24. THE CONTRACTOR SHALL PROVIDE WRITTEN NOTIFICATION TO THE CONTRACTING OFFICER'S REPRESENTATIVE THIRTY
(30) CALENDAR DAYS IN ADVANCE OF THE DATE WHICH THE SPECIAL INSPECTION IS REQUIRED TO TAKE PLACE ON.
25. THE CONTRACTOR TO SUBMIT A PLAN TO PROTECT ODORS FROM ENTERING ANY OUTSIDE AIR INTAKES IN THE VICINITY
OF CONSTRUCTION ACTIVITIES.
AREA BOUNDARY
ELECTRICAL GENERAL NOTES:
1. ENCORUS GROUP ENGINEERING, P.C. ACKNOWLEDGES THE VA PROHIBITION AGAINST USING ALUMINUM COMPONENTS
FOR LIGHTNING PROTECTION. ENCORUS GROUP ENGINEERING, P.C. WILL PROVIDE A DESIGN FOR COPPER LIGHTNING PROTECTION COMPONENTS ON ALUMINUM ROOFING, IN DIRECT VIOLATION OF NFPA 780 CODE AND UL STANDARDS 96A, AT THE DEMAND OF THE VETERANS ADMINISTRATION, HOWEVER ENCORUS GROUP ENGINEERING, P.C. ACCEPTS NO LIABILITY FOR ANY DAMAGES RESULTING FROM GALVANIC CORROSION OF EITHER THE ROOF OR THE LIGHTNING
PROTECTION COMPONENTS.
2. LOCATE AIR TERMINALS AS SHOWN. TAKE CARE TO INSURE THAT ALL POINTS ARE WITHIN 2'-0" OF OUTSIDE BUILDING EDGE, OUTSIDE CORNERS, AND RIDGE ENDS, AND THAT MAXIMUM SPACING DOES NOT EXCEED 20'-0", AND THAT MINIMUM PROJECTION ABOVE OBJECT PROTECTED IS 10". (POINTS PROJECTING 24" MAY BE SPACED AT 25' MAX).
3. MAINTAIN HORIZONTAL OR DOWNWARD COURSING OF MAIN CONDUCTOR AND INSURE THAT ALL BENDS HAVE AT
LEAST AN 8" RADIUS AND DO NOT EXCEED 90°.
4. ATTACH ALL EXPOSED ROOF, DOWN LEAD AND BONDING CABLES AT 3'-0" ON CENTER MAXIMUM. VERIFY
COMPATIBILITY OF ADHESIVE ON MEMBRANE ROOF APPLICATIONS PRIOR TO INSTALLATION.
5. GROUND ELECTRODES SHALL BE INSTALLED AS SHOWN BUT IN NO INSTANCE SHALL THEY BE LESS THAN 1'-0" BELOW GRADE AND 2'-0" FROM FOUNDATION WALL DRIVEN RODS SHALL PENETRATE EARTH AT LEAST 10'-0".
6. BOND TO WATER SERVICE AND OTHER PIPING SYSTEMS AS SHOWN AND AS REQUIRED BY CODES.
7. INTERCONNECT LIGHTNING PROTECTION GROUND TO ELECTRIC, TELEPHONE, AND OTHER BUILDING GROUND
SYSTEMS AS SHOWN OR AS REQUIRED BY CODE.
8. SYSTEM SHALL BE INSTALLED AS SHOWN TO INSURE PROPER CODE COMPLIANCE AND SYSTEM CERTIFICATION. ANY
MAJOR VARIANCE SHALL ENTAIL RE-SUBMITTAL AND NEW APPROVAL.
9. "AS-BUILT" DRAWINGS SHALL BE SUBMITTED IN ACCORDANCE WITH CERTIFICATION PROCEDURES.
10. ALL MATERIALS ARE UNDERWRITERS LABORATORIES APPROVED WITH LABELS ON CONDUCTORS AT 10'-0" INTERVALS
AND LABELS ON ALL AIR TERMINALS.
RD
AT LIGHTNING ROD
GND GROUND CONDUCTOR
DEMOLITION
E ELECTRIC
LINE TYPES
ABBREVIATIONS
NORTH ARROW
DETAIL NUMBER
DETAIL NUMBER
DRAWING REF NUMBER
DRAWING REF NUMBER
DETAIL NUMBER
DRAWING REF NUMBER
DETAIL NUMBER
DRAWING REF NUMBER
DETAIL NUMBER
DRAWING REF NUMBER
VIEWING
DIRECTION
VIEWING
DIRECTION
VIEW TITLE
BUILDING/WALL SECTION CUT
ELEVATION
DETAIL SECTION CUT
DETAIL CALLOUT
DRAWING SYMBOLS
SCALE: X" = 1'-0"
DETAIL TITLEXX
XXXXX
XXXXX
X
XXXXX
X
XXXXX
X
XXXXX
X
SYMBOLS & LEGEND
SYMBOL DESCRIPTION
AREA OF COVERED WALKWAY CANOPIES.
CONSTRUCTION FENCING AND GATE PER SPEC REQUIRED.
CRICKET SLOPE - 1/4" PER FOOT = MAXIMUM OVERALL THICKNESS.
SADDLE SLOPE - 1/4" PER FOOT = MAXIMUM OVERALL THICKNESS.
ROOF SLOPE - 1/4" PER FOOT FLAT ROOF AREAS MIN.
HIGH POINT INSULATION THICKNESS. X = APPROXIMATE THICKNESS BASED UPON
AN AVERAGE R VALUE PRESCRIBED IN THE SPECIFICATIONS AND THE INDICATED
ROOF SLOPE. FIELD VERIFY ALL VALUES.
LOW POINT INSULATION THICKNESS. X = APPROXIMATE THICKNESS BASED UPON
AN AVERAGE R VALUE PRESCRIBED IN THE SPECIFICATIONS AND THE INDICATED
ROOF SLOPE. FIELD VERIFY ALL VALUES.
X
DEMOLISH/REMOVE
L x x x x
ABBREVIATION MEANING
A/E ARCHITECT/ENGINEER
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
ALT ALTERNATE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
AUX AUXILIARY
AVG AVERAGE
BD BOARD
BKG BACKING
BLDG BUILDING
BM BEAM OR BENCHMARK
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BSMT BASEMENT
BTWN BETWEEN
CBB CEMENTITIOUS (BACKER) BOARD
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONSTR CONSTRUCTION
CONTR CONTRACTOR
CONT CONTINIOUS
CT CERAMIC TILE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DOC DOCUMENT
DN DOWN
DR DOOR, DRAIN, OR DRIVE
DS DOWNSPOUT
EA EACH
EPS EXPANDED POLYSTYRENE BOARD
EQ EQUAL
EW EACH WAY
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
EXT GR EXTERIOR GRADE
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FLR FLOOR
FLR FIN FLOOR FINISH
FRMG FRAMING
FT FEET OR FOOT
FTG FOOTING
ABBREVIATION MEANING
GALV GALVANIC OR GALVANIZED
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GWB GYPSUM WALL BOARD
GYP GYPSUM
GYP BD GYPSUM BOARD
HDR HEADER
HM HOLLOW METAL
HORIZ HORIZONTAL
HOSP HOSPITAL
HT HEIGHT
INSUL INSULATION
MAT MATERIAL
OC ON CENTER
OFD OVERFLOW DRAIN
PRELIM PRELIMINARY
PT PAINT, PNEUMATIC TUBE, OR PRESSURE
PTD PAINTED
PWR POWER
QTY QUANTITY
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REQD REQUIRED
RET RETARDANT
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RO ROUGH OPENING
SAN SANITARY
SIM SIMILAR
SPEC SPECIFICATION
SPKLR SPRINKLER
STD STANDARD
STL PL STEEL PLATE
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUSP CLG SUSPENDED CEILING
SYS SYSTEM
TBD TO BE DETERMINED
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TYP TYPICAL
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WD WOOD
WP WATERPROOF
LIGHT FIXTURE, WALL MOUNTED
HP
19" HIGH POINT MARKER
GENERAL DRAWING SYMBOLS
X KEYED NOTE
ARCHITECTURAL SYMBOLS
ELECTRICAL SYMBOLS
LOW POINT MARKER
LP
5"
HP
19"
LP
5"
FULL DOWNLEAD TO GROUND
GENERAL DEMOLITION NOTES:
1. EXISTING MECHANICAL EQUIPMENT, VENTS, PIPING, CONDUIT, EXHAUSTS, DUCTWORK SHALL EITHER BE LEFT IN PLACE
OR TEMPORARILY RELOCATED FOR DEMOLITION/RE-ROOFING/FLASHINGS WORK TO BE EXECUTED IN ACCORDANCE WITH THE DETAILS PROVIDED. ELECTRICAL AND MECHANICAL EQUIPMENT REQUIRING TEMPORARY SHUTDOWN AND RE-START SHALL BE NOTED ON THE EQUIPMENT SCHEDULES PROVIDED ON DRAWINGS. COORDINATE THOSE
SHUTDOWNS WITH THE NORTHPORT VA.
2. REMOVE ALL EXISTING ROOFING MATERIALS AT EACH ROOF AREA AS IDENTIFIED IN THE EXISTING ROOF TYPES ON EACH DEMOLITION PLAN, DOWN TO THE EXISTING ROOF DECK. REMOVALS SHALL INCLUDE ALL BASE FLASHINGS, METAL FLASHING AND OTHER MATERIALS ASSOCIATED WITH THE ROOF AND IN ACCORDANCE WITH THE DETAILS.
3. REFER TO HAZARDOUS REMOVAL DOCUMENTS FOR ANY ROOFING MATERIAL REMOVALS ASSOCIATED WITH THAT
WORK.
4. CONTRACTOR TO POST NOTIFICATION AT BUILDING ENTRANCES IN ACCORDANCE WITH NYS CODE RULE 56, PARAGRAPH 56-3,6(a), 10 DAYS PRIOR TO COMMENCEMENT OF ABATEMENT ACTIVITIES.
5. THE CONTRACTOR SHALL REPLACE ANY EXISTING FIRESTOPPING WHICH WAS DISLODGED OR DAMAGED DURING
CONSTRUCTION.
6. REMOVE ADHESIVES, ASPHALT, AND OTHER MATERIALS DOWN TO THE DECK, TO PROVIDE A UNIFORM, EVEN
SUBSTRATE IN ACCORDANCE WITH GOOD PRACTICE AND NRCA INDUSTRY STANDARDS.
7. NO GAS POWERED EQUIPMENT WILL BE ALLOWED ON THIS PROJECT.
DESIGN DATA:
IN ITS COMPLETED STATE, AE DESIGN SERVICES FOR ROOF REPLACEMENT FOR THE
NORTHPORT VA MEDICAL CENTER IS DESIGNED FOR THE FOLLOWING SURCHARGE
LOADS. DO NOT EXCEED STATED SURCHARGE LOADS.
1. DEAD LOAD: STRUCTURE SELF WEIGHT
2. LIVE LOAD: 100 PSF
2000LB. CONCENTRATED
3. ROOF LIVE LOAD : 20 PSF
4. SNOW LOAD: FLAT ROOF SNOW LOAD Pf = 16.8 PSF GROUND SNOW LOAD Pg = 20 PSF SNOW EXPOSURE FACTOR Ce = 1.0 SNOW LOAD IMPORTANCE FACTOR Is = 1.2 THERMAL FACTOR Ct = 1.0 DRIFT SURCHARGE Pd = 23.1 PSF DRIFT WIDTH w = 5'-6"
5. WIND LOAD : ULTIMATE DESIGN WIND SPEED, Vult = 120 MPH NOMINAL DESIGN WIND SPEED, Vasd = 93 MPH
RISK CATEGORY IV
IMPORTANCE FACTOR, Iw = 1.00
WIND EXPOSURE CATEGORY, B
INTERNAL PRESSURE COEFFICIENT, GCpi = +/-0.18
COMPONENTS AND CLADDING WIND PRESSURES
6. SEISMIC LOAD :
RISK CATEGORY IV
IMPORTANCE FACTORS, Ie = 1.50
SOIL SITE CLASS = C
MAPPED SPECTRAL ACCELERATIONS/RESPONSES
Ss = 0.222 S1 = 0.054
SDS = 0.193
SD1 = 0.054
SEISMIC DESIGN CATEGORY = C
SEISMIC RESISTING SYSTEM = SEISMIC DEMAND ON
NONSTRUCTURAL COMPONENTS
COMPONENT AMPLIFICATION FACTOR, ap = 2.5 COMPONENT RESPONSE MODIFICATION FACTOR, Rp = 1.5
EQUIVALENT LATERAL FORCE METHOD
HORIZONTAL FORCE, Fph = 0.193 x SELF WEIGHT VERTICAL FORCE, Fpv = ± 0.039 x SELF WEIGHT
X COLUMN CENTER LINE
200 North
Zone Net Pressure, p (psf) Net Pressure, p (psf)
A -50 15
B -50 15
C -37 15
D -37 15
E -31 15
ICU
Zone Net Pressure, p (psf) Net Pressure, p (psf)
A -39 12
B -39 12
C -29 12
D -24 12
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text N
X
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
SCHEDULE OF SPECIAL
INSPECTIONS
FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GI003
632-21-118
JPK RJB
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
P – PERFORM THESE SPECIAL INSPECTIONS TASKS FOR EACH WELDED JOINT OR MEMBER. (AISC 360 & AISC 341)
O – OBSERVE THESE SPECIAL INSPECTIONS ITEMS ON A RANDOM DAILY BASIS. OPERATIONS NEED NOT
BE DELAYED PENDING THESE INSPECTIONS. (AISC 360 & 341)
D – DOCUMENT, WITH A REPORT, THAT THE WORK HAS BEEN PERFORMED IN ACCORDANCE
WITH THE CONTRACT DOCUMENTS. (AISC 341)
WOOD CONSTRUCTION
IBC TABLE 1705.5, 1705.10.1 & 1705.11.2
TASK INSPECTION
TYPE DESCRIPTION
1. HIGH-LOAD DIAPHRAGMS P VERIFY THICKNESS AND GRADE OF SHEATHING, SIZE OF FRAMING MEMBERS AT PANEL
EDGES, NAIL/STAPLE DIAMETERS AND LENGTH, AND THE NUMBER OF FASTENER LINES
AND FASTENER SPACING ARE PER APPROVED PLANS. (IBC 1705.5.1)
2. METAL-PLATE-CONNECTED WOOD TRUSSES
SPANNING 60 FEET OR GREATER
P VERIFY THAT TEMPORARY AND PERMANENT TRUSS BRACING IS INSTALLED IN
ACCORDANCE WITH APPROVED TRUSS PACKAGE. (IBC 1705.5.2)
3. FIELD GLUING C INSPECT ALL FIELD GLUING OF STRUCTURAL WOOD ELEMENT WITHIN THE MAIN
WIND-FORCE RESISTING SYSTEM. (IBC 1705.10.1 & 1705.11.2)
4. NAILING, BOLTING, ANCHORING AND OTHER
FASTENING OF COMPONENTS
P IF FASTENERS WITHIN THE MAIN WIND-FORCE RESISTING SYSTEM ARE SPACED LESS
THAN 4-INCHES, VERIFY THAT PROPER NAILING, BOLTING, ANCHORING, AND OTHER
FASTENING OF SHEAR WALLS, DIAPHRAGMS, DRAG STRUTS, BRACES, AND
HOLD-DOWNS. (IBC 1705.10.1 & 1705.11.2)
5. NAILING, BOLTING, ANCHORING AND OTHER
FASTENING OF COMPONENTS
P VERIFY PROPER NAILING, BOLTING, ANCHORING, AND OTHER FASTENING COMPONENTS
WITHIN THE PROGRESSIVE COLLAPSE RESISTING SYSTEM, INCLUDING HORIZONTAL TIE
FORCE ELEMENTS, VERTICAL TIE FORCE ELEMENTS AND BRIDGING ELEMENTS. (UFC
4-023-03, 1717.3)
C – CONTINUOUS SPECIAL INSPECTIONS IS THE CONSTANT MONITORING OF SPECIFIC TASKS BY A SPECIAL INSPECTOR. THESE INSPECTIONS MUST BE CARRIED OUT CONTINUOUSLY OVER THE DURATION OF THE PARTICULAR TASKS. (IBC) P – PERIODIC SPECIAL INSPECTIONS IS SPECIAL INSPECTIONS BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. (IBC)
SPRAYED FIRE-RESISTANT MATERIALS (SFRM)
IBC 1705.13
TASK INSPECTION
TYPE DESCRIPTION
1. SURFACE CONDITION P PRIOR TO APPLICATION CONFIRM THAT SURFACE HAS BEEN PREPARED PER THE
APPROVED FIRE-RESISTANCE DESIGN AND MANUFACTURER'S INSTRUCTIONS. (IBC
1705.13.2)
2. APPLICATION P PRIOR TO APPLICATION CONFIRM THAT THE SUBSTRATE MEETS THE MINIMUM AMBIENT
TEMPERATURE PER THE APPROVED FIRE-RESISTANCE DESIGN AND MANUFACTURER'S
INSTRUCTIONS. (IBC 1705.13.3)
3. MATERIAL THICKNESS P VERIFY THAT THE THICKNESS OF THE SFRM TO STRUCTURAL ELEMENTS IS NOT LESS
THAN THE THICKNESS REQUIRED BY THE FIRE-RESISTANT DESIGN IN MORE THAN 10
PERCENT OF THE MEASUREMENT, BUT IN NO CASE LESS THAN MINIMUM ALLOWABLE
THICKNESS REQUIRED BY 1705.13.4.1 (IBC 1705.13.4)
4. MATERIAL DENSITY P VERIFY THAT THE DENSITY OF THE SFRM TO STRUCTURAL ELEMENTS IS NOT LESS
THAN THE DENSITY SPECIFIED IN THE FIRE-RESISTANT DESIGN. (IBC 1705.13.5)
5. BOND STRENGTH P VERIFY COHESIVE/ADHESIVE BOND STRENGTH OF THE CURED SFRM APPLIED TO THE
STRUCTURAL ELEMENTS IS NOT LESS THAN 150 PSF. (IBC 1705.13.6)
C – CONTINUOUS SPECIAL INSPECTIONS IS THE CONSTANT MONITORING OF SPECIFIC TASKS BY A SPECIAL INSPECTOR. THESE INSPECTIONS MUST BE CARRIED OUT CONTINUOUSLY OVER THE DURATION OF THE PARTICULAR TASKS. (IBC)
P – PERIODIC SPECIAL INSPECTIONS IS SPECIAL INSPECTIONS BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. (IBC)
FIRE-RESISTANT PENETRATIONS AND JOINTS
IBC 1705.16
TASK INSPECTION
TYPE DESCRIPTION
1. PENETRATION FIRESTOPS P LISTED SYSTEMS SHALL BE INSPECTED IN ACCORDANCE WITH ASTM E 2174. (IBC 1705.16.1)
2. FIRE-RESISTANT JOINT SYSTEMS P LISTED SYSTEMS SHALL BE INSPECTED IN ACCORDANCE WITH ASTM E 2393. (IBC 1705.16.2)
C – CONTINUOUS SPECIAL INSPECTIONS IS THE CONSTANT MONITORING OF SPECIFIC TASKS BY A SPECIAL INSPECTOR. THESE INSPECTIONS MUST BE CARRIED OUT CONTINUOUSLY OVER THE DURATION OF THE PARTICULAR TASKS. (IBC) P – PERIODIC SPECIAL INSPECTIONS IS SPECIAL INSPECTIONS BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. (IBC)
ARCHITECTURAL COMPONENTS
IBC 1705.10.3, 1705.11.5 & 1705.11.7
TASK INSPECTION
TYPE DESCRIPTION
1. ROOF AND WALL CLADDING P VERIFY APPROPRIATE MATERIALS, FASTENERS AND ATTACHMENT AT COMMENCEMENT
OF WORK AND AT COMPLETION. (IBC 1705.10.3.1)
C – CONTINUOUS SPECIAL INSPECTIONS IS THE CONSTANT MONITORING OF SPECIFIC TASKS BY A SPECIAL INSPECTOR. THESE INSPECTIONS MUST BE CARRIED OUT CONTINUOUSLY OVER THE DURATION OF THE PARTICULAR TASKS. (IBC)
P – PERIODIC SPECIAL INSPECTIONS IS SPECIAL INSPECTIONS BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. (IBC)
STRUCTURAL STEEL
PRIOR TO WELDING (Table N5.4-1, AISC 360-10 & TABLE J6-1, AISC 341-10):
TASK INSPECTION
TYPE DESCRIPTION
1. VERIFY WELDING PROCEDURES (WPS) AND
CONSUMABLE CERTIFICATES
P (AISC 360 – TABLE N5.4-1)
2. MATERIAL IDENTIFICATION (TYPE/GRADE) O (AISC 360 – TABLE N5.4-1 & AISC 341 – TABLE J6-1)
3. WELDER IDENTIFICATION SYSTEM O A SYSTEM SHALL BE MAINTAINED BY WHICH A WELDER WHO HAS WELDED A JOINT OR
MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS DYE TYPE.
(AISC 360 – TABLE N5.4-1 & AISC 341 – TABLE J6-1)
4. FIT-UP GROOVE WELDS (INCLUDING JOINT
GEOMETRY)
O · JOINT PREPARATION
· DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
· CLEANLINESS (CONDITION OF STEEL SURFACES)
· TACKING (TACK WELD QUALITY AND LOCATION)
· BACKING TYPE AND FIT (IF APPLICABLE) (AISC 360 – TABLE N5.4-1 & AISC 341 – TABLE J6-1)
5. CONFIGURATION AND FINISH OF ACCESS
HOLES
O (AISC 360 – TABLE N5.4-1 & AISC 341 – TABLE J6-1)
6. FIT-UP OF FILLET WELDS O · DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
· CLEANLINESS (CONDITION OF STEEL SURFACES)
· TACKING (TACK WELD QUALITY AND LOCATION) (AISC 360 – TABLE
N5.4-1 & AISC 341 – TABLE J6-1)
DURING WELDING (Table N5.4-2, AISC 360-10 & TABLE J6-2, AISC 341-10):
TASK INSPECTION
TYPE DESCRIPTION
1. USE OF QUALIFIED WELDERS O (AISC 360 – TABLE N5.4-2)
2. CONTROL AND HANDLING OF WELDING
CONSUMABLES
O · PACKAGING
· EXPOSURE CONTROL. (AISC 360 – TABLE N5.4-2 & AISC 341 – TABLE J6-2)
3. NO WELDING OVER CRACKED TACK WELDS O (AISC 360 – TABLE N5.4-2 & AISC 341 – TABLE J6-2)
4. ENVIRONMENTAL CONDITIONS O · WIND SPEED WITHIN LIMITS
· PRECIPITATION AND TEMPERATURE (AISC 360 – TABLE N5.4-2 & AISC 341 – TABLE
J6-2)
5. WPS FOLLOWED O · SETTINGS ON WELDING EQUIPMENT
· TRAVEL SPEED
· SELECTED WELDING MATERIALS
· SHIELDING GAS TYPE/FLOW RATE
· PREHEAT APPLIED
· INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)
· PROPER POSITION (F, V, H, OH)
· INTERMIX OF FILLER METALS AVOIDED UNLESS APPROVED (AISC 360 – TABLE
N5.4-2 & AISC 341 – TABLE J6-2)
6. WELDING TECHNIQUES O · INTERPASS AND FINAL CLEANING
· EACH PASS WITHIN PROFILE LIMITATIONS
· EACH PASS MEETS QUALITY REQUIREMENTS (AISC 360 – TABLE
N5.4-2 & AISC 341 – TABLE J6-2)
AFTER WELDING (TABLE N5.4-3, AISC 360-10 & TABLE J6-3, AISC 341-10):
TASK INSPECTION
TYPE DESCRIPTION
1. WELDS CLEANED O (AISC 360 – TABLE N5.4-3 & AISC 341 – TABLE J6-3)
2. SIZE, LENGTH, AND LOCATION OF WELDS P (AISC 360 – TABLE N5.4-3 & AISC 341 – TABLE J6-3)
3. WELDS MEET VISUAL ACCEPTANCE
CRITERIA
P/D · CRACK PROHIBITION
· WELD/BASE-METAL FUSION
· CRATER CROSS SECTION
· WELD PROFILES
· WELD SIZE
· UNDERCUT
· POROSITY (AISC 360 – TABLE N5.4-3 & AISC 341 – TABLE J6-3)
4. ARC STRIKES P (AISC 360 – TABLE N5.4-3)
5. K-AREA P WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN
PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS
WITHIN 3 IN. OF THE WELD. (AISC 360 – TABLE N5.4-3)
6. BACKING REMOVED AND WELD TABS
REMOVED (IF REQUIRED)
P (AISC 360 – TABLE N5.4-3)
7. BACKING REMOVED, WELD TABS REMOVED
AND FINISHED, AND FILLET WELDS ADDED
(IF REQUIRED)
P/D (AISC 341 – TABLE J6-3)
8. PLACEMENT OF REINFORCING OR
CONTOURING FILLET WELDS (IF REQUIRED)
P/D (AISC 341 – TABLE J6-3)
9. REPAIR ACTIVITIES P/D (AISC 360 – TABLE N5.4-3 & AISC 341 – TABLE J6-3)
10. DOCUMENT ACCEPTANCE OR REJECTION
OF WELDED JOINT/MEMBER
P (AISC 360 – TABLE N5.4-3)
NONDESTRUCTIVE TESTING OF WELDED JOINTS (AISC 360-10: SECTION N5.5, IBC 1705.2.1):
TASK INSPECTION
TYPE DESCRIPTION
1. USE OF QUALIFIED NONDESTRUCTIVE
TESTING PERSONNEL
P VISUAL WELD INSPECTION AND NONDESTRUCTIVE TESTING (NDT) SHALL BE
CONDUCTED BY PERSONNEL QUALIFIED IN ACCORDANCE WITH AWS D1.8 CLAUSE 7.2.
2. CJP GROOVE WELDS O DYE PENETRANT TESTING (DT) AND ULTRASONIC TESTING (UT) SHALL BE PERFORMED
ON 20% OF CJP GROOVE WELDS FOR MATERIALS GREATER THAN 5
16" (8MM) THICK.
TESTING RATE MUST BE INCREASED TO 100% IF GREATER THAN 5% OF WELDS TESTED
HAVE UNACCEPTABLE DEFECTS.
3. WELDED JOINTS SUBJECT TO FATIGUE O DYE PENETRANT TESTING (DT) AND ULTRASONIC TESTING (UT) SHALL BE PERFORMED
ON 100% WELDED JOINTS IDENTIFIED ON CONTRACT DRAWINGS AS BEING SUBJECT TO
FATIGUE.
4. WELD TAB REMOVAL SITES O AT THE END OF WELDS WHERE WELD TABS HAVE BEEN REMOVED, MAGNETIC PARTICLE
TESTING SHALL BE PERFORMED ON THE SAME BEAM-TO-COLUMN JOINTS RECEIVING
UT.
PRIOR TO BOLTING (TABLE N5.6-1, AISC 360-10 & TABLE J7-1, AISC 341-10):
TASK INSPECTION
TYPE DESCRIPTION
1. MANUFACTURE'S CERTIFICATION
AVAILABLE FOR FASTENER MATERIALS
P (AISC 360 – TABLE N5.6-1)
2. FASTENERS MARKED IN ACCORDANCE WITH
ASTM REQUIREMENTS
O (AISC 360 – TABLE N5.6-1)
3. PROPER FASTENERS SELECTED FOR JOINT
DETAIL (GRADE, TYPE, BOLT LENGTH IF
THREADS ARE TO BE EXCLUDED FROM
SHEAR PLANE)
O (AISC 360 – TABLE N5.6-1 & AISC 341 – TABLE J7-1)
4. PROPER BOLTING PROCEDURE SELECTED
FOR JOINT DETAIL
O (AISC 360 – TABLE N5.6-1 & AISC 341 – TABLE J7-1)
5. CONNECTING ELEMENTS, INCLUDING
APPROPRIATE FAYING SURFACE CONDITION
AND HOLE PREPARATION, IF SPECIFIED,
MEET APPLICABLE REQUIREMENTS
O (AISC 360 – TABLE N5.6-1 & AISC 341 – TABLE J7-1)
6. PRE-INSTALLATION VERIFICATION TESTING
BY INSTALLATION PERSONNEL OBSERVED
AND DOCUMENTED FOR FASTENER
ASSEMBLIES AND METHODS USED
O/D (AISC 360 – TABLE N5.6-1 & AISC 341 – TABLE J7-1)
7. PROPER STORAGE PROVIDED FOR BOLTS,
NUTS, WASHERS, AND OTHER FASTENER
COMPONENTS
O (AISC 360 – TABLE N5.6-1 & AISC 341 – TABLE J7-1)
DURING BOLTING (TABLE N5.6-2, AISC 360-10 & TABLE J7-2, AISC 341-10)
TASK INSPECTION
TYPE DESCRIPTION
1. FASTENER ASSEMBLIES OF SUITABLE
CONDITION, PLACED IN ALL HOLES AND
WASHERS (IF REQUIRED) ARE POSITIONED
AS REQUIRED
O (AISC 360 – TABLE N5.6-2 & AISC 341 – TABLE J7-2)
2. JOINT BROUGHT TO THE SNUG-TIGHT
CONDITION PRIOR TO PRETENSIONING
OPERATIONS
O (AISC 360 – TABLE N5.6-2 & AISC 341 – TABLE J7-2)
3. FASTENER COMPONENT NOT TURNED BY
THE WRENCH PREVENTED FROM ROTATING
O (AISC 360 – TABLE N5.6-2 & AISC 341 – TABLE J7-2)
4. FASTENERS ARE PRETENSIONED IN
ACCORDANCE WITH RCSC SPECIFICATION,
PROGRESSING SYSTEMATICALLY FROM THE
MOST RIGID POINT TOWARD THE FREE
EDGES
O (AISC 360 – TABLE N5.6-2 & AISC 341 – TABLE J7-2)
AFTER BOLTING (TABLE N5.6-3, AISC 360-10 & TABLE J7-3, AISC 341-10):
TASK INSPECTION
TYPE DESCRIPTION
1. DOCUMENT ACCEPTANCE OR REJECTION
OF BOLTED CONNECTIONS
P/D (AISC 360 – TABLE N5.6-3 & AISC 341 – TABLE J7-2)
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
200N
ICU
PHASE 1
PHASE 4
PARKING
PARKING
LOT L
PARKING
TENNIS
COURT
PHASE 2
FOLLOW EXPANSION
JOINT LINE TO DIVIDE
PHASING
PHASE 3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
PROJECT PHASING PLAN FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GC101
632-21-118
JPK CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
GENERAL NOTES
1. SEE GI002 FOR NOTES AND LEGENDS.
2.
CONTRACTOR RESPONSIBLE FOR ALL MEANS AND METHODS, MOVEMENT OF
MATERIAL, SAFETY PRECAUTIONS, STORAGE AND MAINTENANCE OF EXITS FROM THE
BUILDING.
3. NOTIFY THE VA IN WRITING OF ALL SHUTDOWNS FOR EQUIPMENT. PER THE
GUIDELINES SET FORTH ON THE DRAWINGS AND SPECIFICATIONS.
PHASING
PHASING AREA BUILDINGS
PHASE 1 ICU ROOF
PHASE 2 200N WEST ROOF
PHASE 3 LOW ROOF AT ENTRANCE
PHASE 4 200N EAST ROOF
SCALE:
PROJECT PHASING PLAN1 100'
1"=100'-0"
0 200'
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
X
X
X X
X X
PARKING
PARKING
LOT L
PARKING
TENNIS
COURT
ICU
200N
X
X
X
EXISTING TUNNEL
ENTRANCE
12' GATE & FENCE
12' GATE
STAGING AREA 3
TEMPORARY FENCE
STAGING AREA 1
X
12' GATE
12' GATE
STAGING AREA 2
X
TEMPORARY FENCE
TEMPORARY FENCE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
PROJECT STAGING PLAN FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GC102
632-21-118
JPK CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
GENERAL NOTES
1. SEE GI002 FOR NOTES AND LEGENDS.
2.
CONTRACTOR RESPONSIBLE FOR ALL MEANS AND METHODS, MOVEMENT OF
MATERIAL, SAFETY PRECAUTIONS, STORAGE AND MAINTENANCE OF EXITS FROM THE
BUILDING.
3.
NOTIFY THE VA IN WRITING OF ALL SHUTDOWNS FOR EQUIPMENT, CELL SERVICE,
RADIO SERVICE, ETC. PER THE GUIDELINES SET FORTH ON THE DRAWINGS AND
SPECIFICATIONS.
4.
CONTRACTOR IS TO SUBMIT A STAGING PLAN FOR EACH PHASE AT THE START OF THE
CONSTRUCTION PROJECT (WITHIN 10 CALENDAR DAYS OF THE NTP.)
5. GAS POWERED EQUIPMENT IS NOT PERMITTED ON THIS PROJECT. THIS INCLUDES,
BUT IS NOT LIMITED TO WINCHES, LIFTS, ETC., WHICH SHALL BE ELECTRIC.
6. CONTRACTOR'S VEHICLES SHALL NOT BE IDLING WITHIN 50 FEET OF ANY OUTSIDE AIR
INTAKE.
7.
THE CONDENSING UNIT LOCATED ON THE EAST SIDE OF BUILDING 200 NORTH SHALL
BE PROTECTED FROM DAMAGE AND NOT ENCLOSED IN ANY STAGING AREA VA AC
SHOP TECHNICIANS NEED TO BE ABLE TO ACCESS IT 24/7.
8.
ENSURE THAT FREE ACCESS FROM THE STREET FOR FIRE HYDRANTS AND THE SPRINKLER
SYSTEM FIRE DEPARTMENT CONNECTION IS MAINTAINED AT ALL TIMES. ADD NECESSARY
GUIDANCE AND DETAILS TO THE DRAWING TO ENSURE TEMPORARY FENCING DOES NOT
OBSTRUCT THESE ITEMS.
STAGING
STAGING BUILDING
STAGING AREA 1 ICU
STAGING AREA 2 ICU & 200N
STAGING AREA 3 200N
KEYED NOTES
1 TEMPORARY FENCING TO BE 8' HIGH CHAIN LINK WITH LOCKABLE SWING GATES AND LOCKABLE
PEDESTRIAN GATES AS REQUIRED.
2 PROVIDE COVERED TEMPORARY PROTECTION TO MAINTAIN PATHWAY FROM BUILDING DURING
CONSTRUCTION REFER TO SECTION 01 35 26 SAFETY REQUIREMENTS.
PROVIDE COVERED TEMPORARY PROTECTION OVER ENTRANCE AWNINGS AND UNDER COVERED
CANOPY TO MAINTAIN PATHWAY FROM BUILDING. REFER TO SECTION 01 35 26 SAFETY
REQUIREMENTS.
4 PROVIDE COVERED TEMPORARY PROTECTION OVER AREAWAY AND GROUND MOUNTED HVAC
UNITS. MAINTAIN EGRESS INTO AREAWAY. REFER TO 01 35 26 SAFETY REQUIREMENTS.
5 DUMPSTER
6 SCAFFOLD AREA AS REQUIRED TO PERFORM ROOF WORK AND STAGING.
7 SCAFFOLD OVER COVERED PROTECTED AREA TO PERFORM ROOF ABOVE.
CONTRACTOR TO PROTECT OUTSIDE AIR INTAKES FROM ANY CONSTRUCTION RELATED ODORS
AND DUST. ALL DEBRIS AND ODOR GENERATING ACTIVITIES WILL BE AT LEAST 25 FEET FROM THE
OAI.
9 PROVIDE COVERED TEMPORARY PROTECTION OVER CONDENSING UNITS AND PROVIDE ROOM
BETWEEN BUILDING & TEMPORARY FENCE FOR 24/7 ACCESS TO THESE UNITS.
10 TRASH CHUTE FROM ROOF TO DUMPSTER SUPPORTED OVER PROTECTED CONDENSING UNITS
BELOW.
11 TRASH CHUTE
SCALE:
PROJECT STAGING PLAN1 100'
1"=100'-0"
0 200'
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
PHASE 2A
PHASE 2C PHASE 4C
PHASE 4A
PHASE 2B PHASE 2B
PHASE 2B
PHASE
2B PHASE 2B
PHASE
2B
PHASE
2B
PHASE 3A
PHASE 4B
PHASE
4B
PHASE 4B PHASE 4B
PHASE 4B
PHASE 2A
S R.9 R Q P N M L K
J.5 J H.5
H.5 H GG.2 F.9 F E D C B AA.1
23.3
SKYLIGHT
RD33RD32RD31RD30RD29
RD28RD22
RD21
RD19RD18
RD17
RD16RD15
RD1
RD2
RD6
RD7 RD8
RD9 RD14
RD20 RD23
RD24
RD3 RD4 RD5 RD10 RD11 RD12 RD13
RD27
RD26
RD25
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ROOF PHASE & DESCRIPTION - 200N FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GC103
632-21-118
GHR CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
ICU
PARKING
LOT L
KEYPLAN
200N
SCALE: 3/32" = 1'-0"
ROOF PHASE & DESCRIPTION - 200N1
ROOFING SYSTEM SCHEDULE
BUILDING ROOFING MATERIALS ROOF
DETAIL
ROOFING
SPEC.
SECTION
ROOF
REFLECTANCE
RATING (MIN)
INSULATION
TYPE
INSULATION
R VALUE
INSULATION
SPEC.
SECTION
COMMENTS
PHASE 1 ICU
ICU MINA ROOF (1A) TPO ROOF 4/A-503 NOTE 6 78 FLAT 33 MIN. NOTE 1 NOTE 4
ICU STAIR ROOF (1B) TPO ROOF 6/A-503 NOTE 6 78 FLAT 33 MIN. NOTE 1 NOTE 5
PHASE 2 200N WEST ROOF AREA
200N WEST ROOF (2A) TPO ROOF 4/A-501 NOTE 8 78 FLAT 33 MIN. NOTE 1 NOTE 8
200N WEST ROOF (2B) TPO ROOF 3/A-501 NOTE 9 78 TAPERED 33 AVG. NOTE 2 NOTE 9
200N WEST STAIR ROOF (2C) TPO ROOF 5/A-501 NOTE 7 78 TAPERED 33 AVG. NOTE 2 NOTE 7
PHASE 3 200N LOW ROOF AT MAIN ENTRANCE
200N LOW ROOF (3A) TPO ROOF 5/A-501 NOTE 7 78 TAPERED 33 AVG. NOTE 2 NOTE 7
PHASE 4 200N EAST ROOF AREA
200N EAST ROOF (4A) TPO ROOF 4/A-501 NOTE 8 78 FLAT 33 MIN. NOTE 1 NOTE 8
200N EAST ROOF (4B) TPO ROOF 3/A-501 NOTE 9 78 TAPERED 33 AVG. NOTE 2 NOTE 9
200N EAST STAIR ROOF (4C) TPO ROOF 5/A-501 NOTE 7 78 TAPERED 33 AVG. NOTE 2 NOTE 7
200N TOTAL
NOTES:
1. SPEC. SECTION 07 22 00 ROOF AND DECK INSULATION, 2.1.A.1 FLAT INSULATION
2. SPEC. SECTION 07 22 00 ROOF AND DECK INSULATION, 2.1.A.2 TAPERED INSULATION
3. ALL ROOF AREAS PROVIDED ARE APPROXIMATE AND SHALL BE VERIFIED BY THE CONTRACTOR.
4. STEEL ROOF DECK AND STRUCTURE ARE SLOPED TO LOW AREAS, PROIVDE CRICKETS AS SHOWN ON DRAWINGS TO ADDITIONAL DRAINAGE
5. STEEL ROOF DECK AND STRUCTURE ARE FLAT AT HIGH AND LOW ROOFS, AND SLOPED AT THE ELEVATION CHANGE. PROVIDE CRICKETS AS SHOWN ON DRAWINGS TO ADDITIONAL DRAINAGE
6. SPEC. SECTION 07 54 23.THERMOPLASRIC POLYOLEFIN (TPO) 2.1.A.2
7. STEEL ROOF STRUCTURE IS FLAT, PROVIDE TAPERED INSULATION AND SLOPE TO LOW PORTION OF ROOF
8. CONCRETE DECK STRUCTURE IS SLOPED TO DRAINS, PROVIDE CRICKETS FOR ADDITIONAL DRAINAGE.
9. CONCRETE DECK IS FLAT, PROVIDE TAPERED INSULATION, AND CRICKETS FOR DRAINAGE.
HATCH &
PHASE
PHASE 1
PHASE 2
PHASE 3
PHASE 4
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text N
Q N L
RO
OF
PI
TC
H
RO
OF
PI
TC
H
PITCH
PITCH
OPENOPEN
SL
OP
ED
RO
OF
RD1 RD2 RD3
RD4
PHASE 1B
PHASE 1A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
ROOF PHASE & DESCRIPTION - ICU FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
GC104
632-21-118
GHR CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
ICU
PARKING
LOT L
KEYPLAN
200N
SCALE: 1/4" = 1'-0"
ROOF PHASE & DESCRIPTION - ICU1
GENERAL NOTES
1. SEE GC103 FOR ROOF PHASE AND DESCRIPTION.
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text N
Q N L
RO
OF
PI
TC
H
RO
OF
PI
TC
H
PITCH
PITCH
OPENOPEN
SL
OP
ED
RO
OF
RD1 RD2 RD3
RD4
1 1
IC
U
RO
OF
T O
BE
R
EP
LA
CE
D
BL
DG
EX
IS
TI
NG
R
OO
F
TO
R
EM
AI
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
HAZARDOUS ABATEMENT- ICU
ROOF PLAN
FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18
HA101
632-21-118
JPK CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
ICU
PARKING
LOT L
KEYPLAN
200N
SCALE: 1/4" = 1'-0"
HAZARDOUS ABATEMENT - ICU ROOF PLAN1
GENERAL NOTES
1. SEE GI002 FOR NOTES AND LEGENDS.
2. PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND
FEDERAL RULES, REGULATIONS, GUIDELINES, AND THE CONTRACT DOCUMENTS
3. IF ANY PREVIOUSLY-UNIDENTIFIED OR OTHERWISE UNANTICIPATED SUSPECT
MATERIAL IS IDENTIFIED DURING CONSTRUCTION, STOP WORK AND NOTIFY THE
OWNER OR THEIR REPRESENTATIVE FOR FURTHER DIRECTION. UNDER NO
CIRCUMSTANCES SHALL THE CONTRACTOR COLLECT AND/OR ANALYZE BULK
SAMPLES OF SUSPECT MATERIALS WITHOUT THE APPROVAL OF THE OWNER OR
THEIR REPRESENTATIVE.
4. THE DISTURBANCE OF ANY ASBESTOS-CONTAINING MATERIAL (ACM), OR SUSPECT
ACM, SHALL BE PERFORMED BY A LICENSED ASBESTOS ABATEMENT CONTRACTOR.
5. ALL MATERIAL MEASUREMENTS AND/OR QUANTITIES AND LOCATIONS ARE
APPROXIMATE AND FOR GENERAL ORIENTATION ONLY.
6. THE LOCATION OF SITE STORAGE OF MATERIAL, EQUIPMENT, WASTE
TRAILER/DUMPSTER(S), AS WELL AS CONTRACTOR PARKING, ETC. SHALL BE
COORDINATED WITH AND APPROVED BY THE OWNER/OWNER'S REPRESENTATIVE.
7. CONTRACTOR IS RESPONSIBLE FOR ALL TOOLS, EQUIPMENT, AND SUPPLIES.
CONTRACTOR IS ALSO RESPONSIBLE FOR PROVIDING LADDERS, SCAFFOLDING, LIFTS,
PLANKING, ETC. AS REQUIRED TO PERFORM WORK. THE OWNER OR THEIR
REPRESENTATIVE WILL NOT BE RESPONSIBLE FOR LOST, DAMAGED, OR STOLEN
ITEMS.
8. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING THE WORK AREA IN A CLEAN AND
SAFE CONDITION, PROVIDING TEMPORARY PROTECTION, PROTECTING BUILDING
MATERIALS SCHEDULED TO REMAIN, AND TO PREVENT UNAUTHORIZED ACCESS
DURING THE DURATION OF THE PROJECT. REPAIR OF DAMAGE CAUSED AS A RESULT
OF INADEQUATE TEMPORARY PROTECTION OR CONTRACTOR ACTIVITIES WILL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
9. ALL REMOVED ASBESTOS-CONTAINING MATERIALS AND ASBESTOS-CONTAMINATED
WASTE SHALL BE PROPERLY PACKAGED PRIOR TO BEING REMOVED FROM THE WORK
AREA(S). WARNING LABELS SHALL BE APPLIED TO ASBESTOS WASTE CONTAINERS AS
APPROPRIATE. ALL ASBESTOS-CONTAINING MATERIALS/ASBESTOS-CONTAMINATED
WASTE REMOVED FROM THE WORK AREA(S) SHALL BE ACCOMPANIED BY A WASTE
SHIPMENT RECORD. COMPLETED WASTE SHIPMENT RECORDS MUST BE PROVIDED TO
THE OWNER AS PART OF THE CLOSEOUT DOCUMENTATION. ALL ORIGINAL WASTE
SHIPMENT RECORDS MUST BE PROVIDED TO THE OWNER WITHIN 35 DAYS OF THE
WASTE LEAVING THE SITE
10. COORDINATE ALL WORK ACTIVITIES WITH THE OWNER/OWNER'S REPRESENTATIVE TO
ENSURE ONSITE ACTIVITIES ARE ACCEPTABLE TO THE OWNER, AND THAT REMOVALS
ARE SUFFICIENT TO ACCOMMODATE THE PROJECT ACTIVITIES.
11. REFER TO SPECIFICATION SECTIONS 028213.21 AND 028333.13 AND THE CONTRACT
DOCUMENTS FOR ADDITIONAL INFORMATION AND COORDINATION.
12. CONTRACTOR SHALL POST SIGNAGE AHEAD OF ABATEMENT ACTIVITIES IN
ACCORDANCE WITH NY STATE CODE RULE 56.
ABATEMENT LOG
KEY LOCATION MATERIAL SIZE PIECES
200 ICU ROOF
REMOVE CONCRETE DUNNAGE SUPPORTS AT
BOTH SIDES OF HVAC DUCTWORK SUPPORT.
ASBESTOS TAR HAS BEEN FOUND ON
CONCRETE SUPPORTS, PROVIDE TEMPORARY
SUPPORTS WHILE UNDER CONSTRUCTION.
30 SF 21
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text N
A
A
1 1/2"x1/4" GALV PL
POST 48" OC MAX
4"
3"
8" 8"
8"
1 1/2" DIA GALV PIPE RAILING
1 1/4" DIA GALV STEEL
PIPE (3) TYP
1/2"x4" MIN. THREADED ROD ANCHORS
FOR USE IN CRACKED AND UNCRACKED
CONCRETE, (2) PER BRACKET, ATTACH
TO EXISTING PRECAST COPING OVER
NEW FLASHING. FASTENERS TO COMPLY
WITH ICC-ESR-3699 OR EQUIVALENT
1 1/2"x1/4" GALV PLATE
POST AT 48" OC MAX
SECTION A-A
NEW COPING
HIGH ROOF
ELEV
" F
RO
M
TO
P
OF
R
OO
F
AT
H
IG
HE
ST
P
OI
NT
5"x3x1/4"x4" STL GALV BRACKET
WELDED TO PLATE AND POST
6"x1/4"x1/4" ANCHORS
ATTACHED TO PLATE
1'- 1 1
/4"
2 1 /2"
OC
8" 8"
8"
1/8" THK x7" HIGH GALV STEEL
CONT BAND ATTACHED TO
METAL STUDS
1/4"x4" SELF-DRILLING
FASTENERS, (2) PER BRACKET,
ATTACH TO EXISTING OR NEW
STEEL BAND. FASTENERS TO
COMPLY WITH ICC-ESR-1976 OR
EQUIVALENT
A
A
1 1/2"x1/4" GALV PL
POST 48" OC MAX
3"
NEW COPING
HIGH ROOF
ELEV
" F
RO
M
TO
P
OF
R
OO
F
AT
H
IG
HE
ST
P
OI
NT
5"x3x1/4"x4" STL GALV BRACKET
WELDED TO PLATE AND POST
SECTION A-A
1'- 1 1
/4"
4"
6"x1/4"x1/4" ANCHORS
ATTACHED TO PLATE
2 1 /2"
OC
PREMOLDED PIPE SEAL
INNER CUT OFF MASTIC
BASIS OF DESIGN "FRONTLINE
ANCHOR 70870-L16FL
LAP SEALANT
CAP SPLICE
SPLICING CEMENT
1'- 6"
8" MI
N
CONNECTION POINT
FALL PROTECTION ANCHOR 18" HIGH 4"
Ø SCH 40 PIPE WITH PLATE ON BOTTOM
THROUGH BOLTED TO PLATE BELOW
(8) 1/2" HEX NUT THROUGH BOLTED
TO BOTTOM OF DECK WITH LOCK
NUTS AND WASHERS
11"x11"x3/4" THK PLATE
11"x11x5/8" THK PLATE
ATTACHED TO ANCHOR
1 1/2" DIA PIPE RAILING
C8x11.5 CHANNEL STRINGER
3'-0" WIDE OPEN GRATED PLATFORM
& TREADS WELDED TO ANGLES
2" x 2" X1/4" ANGLE WELDED TO
CHANNEL AND STAIR TREADS (TYP)
1"
1"
3'- 6"
1'- 9"
1'- 9"
2'-
3'-0"
7 9 /16
CONCRETE PAVER
ROOF SYSTEM
AS SPECIFIED
CONC DECK
2"x6" TREATED BLOCKING
AS REQUIRED
FLASH OVER WD BLOCKING
ATTACH STAIR TO WD BLOCKING
USE SS BOLTS FOR ALL
BOLTED CONNECTIONS
ALL STEEL TO BE GALVANIZED
AFTER FABRICATION
12" TREADS
3"X3"X1/4" CLIP WELDED TO STRINGER
WITH HOLES FOR BOLTS
ATTACH TO WOOD BLOCKING WITH (2) SS 1/2"x6"
LAG BOLTS AND WASHERS AT EACH STRINGER
11"
TYP
1'-0"
TYP
7" 7"
4" 7"
1"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
STRUCTURAL DETAILS FINAL BID DOCUMENTS REPLACE ICU AND 200 NORTH
ROOFS
79 MIDDLEVILLE ROAD
NORTHPORT, NY 11768
2022-03-18 S-501
632-21-118
DJS CJR
REV 0 FINAL BID DOCUMENTS 2022-03-18
"Unauthorized alteration or addition to any plans, specifications or reports bearing a Licensed Professional Engineer's seal is a violation of Section 7209, subdivision 2, of the New York State Education Law".
ACM TESTING
MABBETT & ASSOCIATES, INC.
105 CENTRAL STREET, SUITE 4100
STONEHAM, MA 02180
TEL: 781-275-6050
INFO@MABBETT.COM
WWW.MABBETT.COM
DRONE THERMAL IMAGING
EAGLEHAWK ONE, INC.
3819 SOUTH PARK AVE,
BUFFALO, NY 14219
CELL: 716-698-2385
AHERR@EAGLEHAWK.IO
SCALE: 1-1/2"=1'-0"
STRUCTURAL RAILING DETAIL AT ICU1
A-103
SCALE: 1-1/2"=1'-0"
STRUCTURAL RAILING DETAIL AT 200N2
A-101 A-102
SCALE: 1-1/2" = 1'-0"
FALL PROTECTION TIE DOWN DETAIL AT ICU3
A-103
SCALE: 1-1/2" = 1'-0"
STRUCTURAL STAIR DETAIL AT 200N4
A-102
GENERAL NOTES
1. SEE GI002 FOR NOTES AND LEGENDS.
KEYED NOTES
THE NEW GUARDRAILS AT COLUMN LINE 23.3 AT THE NORTH HIGH ROOF AT EACH SIDE OF
THE SKYLIGHT WILL REQUIRE A NEW SUPPORT PLATE AT THE PARAPET. THIS PLATE NEEDS
TO BE INSTALLED AT THE NEW RAILING LOCATIONS. CONTRACTOR IS TO REMOVE THE
PLYWOOD WALL SHEATHING, INSTALL A NEW HORIZONTAL 1/8” THICK, X 7” HIGH
GALV. STEEL CONTINUOUS PLATE BAND IN THE WALL. COVER WALL WITH NEW TREATED
PLYWOOD SHEATHING, COVER WALL WITH FLASHING, AND INSTALL NEW GUARDRAIL.
PROTECT AND REPAIR AND DISTURBED MATERIALS INSIDE PARAPETS SUCH AS WIRING,
INSULATION, FIRE SAFING, ETC
3/18/2022
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
Aut…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .