SALIENT CHARACTERISTICS

For

INDUSTRIAL SHEAR

1.0. SCOPE OF EQUIPMENT:

All proposed products shall meet or exceed the following specifications outlined in this Salient Characterizes. All items shall be delivered to the 309th Aerospace Maintenance and Regeneration Group (AMARG) – FOB DESTINATION

1.1. PRODUCT PERFORMANCE SPECIFICATION:

Industrial Shear must meet the minimum specifications below:

SPECIFICATIONS

Industrial Shear Dimensions Not to Exceed (NTE):
· Machine Width with Back Gauge: 80" (NTE)

· Height: 97" (NTE)

· Length: 173" (NTE)

· Table Height: 32" (NTE)

Shearing Capacity:
· 36-Mild Steel: 3/4" x 144"

· 304-Stainless Steel: 1/2" x 144"

Back-Gauge specs:
· Manual Back-Gauge

· 36" Powered Back-Gauge with Multi-Job Programming LED Touch Screen/Display:

· Manual and Programmable Functions

· Inch/Metric conversion and Stroke Counter

· Programmable X (backstop)

· +/-0.005" Backstop Repeatability

Standard Options:
· 48" Squaring Arm with Inlaid Scale (0-48"):

· Flip Up Stops

· Solid Tabletop with :

· Heavy Duty Ball Transfer in Table

· Automatic Lubricant Assembly or One Shot

· Oil Cooler for Hydraulic System

· Power Adjustable Rake

· Powered Blade Gap Adjustment

· Hydraulic Self-Compensating Hold Downs with Anti-Marking Caps

· Knives with Four Cutting Edges

· Must Be Steel Construction

· Hour Meter

· All Hydraulic Oil Supplied for Machine Start-Up

· Work Light

· Bolt/Shim Kit for Leveling

Manufacture/Power Specs:
· Country Of Manufacture must be United States

· Available Power: 460v 3 Phase

· Electrical Standard Compliant NFPA 79

· Safety Interlock for Foot Guard Operation with 120v

· Power Disconnect Switch

Safety/Warranty/ Training:

· All Safeguarding Features Must Be OSHA/ANSI compliant but not limited to:

· 1910.212(a)(1); 1910.212(a)(3)-(iii)

· ANSI B 11.4-2003

· Master Keylock Switch

· 5-Year Parts AND 5-Year On-Site Labor

· Must Have On-Site Machine Start-Up and Training of Operators up to (3) Personal And (2) Maintenance Personal