Attachment 2 Locations W9124C24R0030.pdf
PDF 191 KB Posted
- Attached to
- Generator Monitoring Federal contract opportunity
- Solicitation number
- W9124C24R0030
About this file
This document appears to be an attachment titled "Attachment 2 Locations W9124C24R0030.pdf" that contains an inventory of generators located at various facilities. The attachment lists details about each generator including the building number, function, manufacturer, model, serial number, fuel type, power output, and regulatory classification status.
The related federal contract opportunity is for a non-personal services contract to provide Generator Monitoring at Fort Jackson. The contract shall provide monitoring for existing Omnimetrix cellular monitors on up to 20 generators to ensure compliance with environmental regulations. The contractor shall also provide maintenance and/or replace monitors that are no longer functioning. The maintenance technician shall be based in close proximity to the Columbia area. The solicitation number is W9124C24R0030 and the contracting agency is the Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SITE VISIT ARRANGEMENTS.pdf | ||
| Solicitation W9124C24R0030 Generator Monitoring.pdf | ||
| Attachment 1 PWS Generator Monitoring W9124C24R0030.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix A Generator Inventory
Building Number Serviced By
Specific Location
Building Function
Engine Manufacturer
Engine Model Number
Engine Serial Number
Genset Manufacturer
Genset Model Number Genset Serial Number Fuel
Generator Output (kW) Engine HP
Manufacture Date Qty
Regulatory Classification Status
2400 DPW Behind building Headquarters Cummins TD400-01 P-8376 Diesel 400 536 Jun-15 IIII
2609 DPW
Behind building, inside fence NEC Mitsubishi 4D34-T(?) Unknown Generac 3931290100 2076879 Diesel 60 80 Apr-04 1 ZZZZ
3100 DPW
Next to building, inside fence NEC Cummins Unknown Unknown Cummins DSFAE-7295859 F110221737 Diesel 80 107 Jun-11 1 IIII
J4236 DPW
Next to building, inside fence NEC Mitsubishi 4D34-T 0D5825 Generac 3617980100 2074860 Diesel 80 107 Nov-03 1 ZZZZ
4282 DPW Behind building NEC Cummins Q5X15-G9 79635574 Cummins DFEH-1220445 A130452520 Diesel 354 475? Jan-13 1 IIII
5499 DPW N/A
EMS/Fire
Department Cummins GTA855C1 25273798 Elliot Power Systems 180RN BX01J193 Natural Gas 180 293 Nov-01 1
Institutional - Not subject
5615 DPW
Behind building, inside fence NEC Cummins QSM11-G4NR3 2003245 Cummins DQHAB-8086897 J110256725 Diesel 300 402 Sep-11 1 IIII
12020 DPW N/A NEC Cummins Unknown Unknown Cummins DSFAE-7295845 F110221739 Diesel 80 107 Jun-11 1 IIII
4th Gate DPW N/A N/A John Deere Unknown PE4024R011093 Generac 10648970200 2101070 Diesel 30 40 Nov-09 1 IIII Scheduled for removal
5th Gate DPW N/A N/A John Deere Unknown PE4024R007046 Generac 10648970200 2101071 Diesel 30 40 Jan-09 1 IIII Scheduled for removal
JRR DPW
Johnson Rifle
Road NEC Unknown Unknown Generac 14861230100 2118091 Diesel 50 67 Dec-16 1 IIII
7533 LRC N/A
Emergency Operations
Center (EOC) MTU 6R1600G70S 16301001230 MTU/Marathon
Electric 433PSL6216 MX159004 PH Diesel 275 369 2010 1 IIII
7540 LRC N/A
NACA (lie detector school) John Deere 6068HF285 PE6068L118699 Stamford Unknown M10A021821 Diesel 150 177 Apr-10 1 IIII F7905 LRC Inside fence Range Control Unknown Unknown TN4T00175 Generac 12700960100 2109064 Diesel 7 51 Jan-11 1 IIII