Attachment 2 Ft Wayne.doc

DOC document 68 KB Posted

Attached to
H159--Three (3) Year High Voltage Electrical Inspection and Calibration
Solicitation number
36C25020Q1016
Issued by

View the file

Other files

File Type Posted
E-103.pdf PDF
36C25020Q1016.docx DOCX document
Ft Wayne 01 Site Plan.pdf PDF
E-114.pdf PDF
E-122.pdf PDF
E-101.pdf PDF
E-118.pdf PDF
E-111.pdf PDF
E-105.pdf PDF
E-102.pdf PDF
E-117.pdf PDF
E-119.pdf PDF
E-115.pdf PDF
E-104.pdf PDF
E-109.pdf PDF
Marion Campus Site Map.pdf PDF
E-121.pdf PDF
E-100.pdf PDF
1a G Table 3.2 Marion.docx DOCX document
E-120.pdf PDF
08 Marion VA Site Electrical Loop Schematic Model (1).pdf PDF
E-108.pdf PDF
E-110.pdf PDF
E-106.pdf PDF
E-116.pdf PDF
1a D Dry Type Transformer Marion.docx DOCX document
1a H Motor Control Centers Marion.docx DOCX document
E-107.pdf PDF
E-113.pdf PDF
E-112.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

FOR ELECTRICAL TESTING

ATTACIEVIENT 2

EQUIPMENT TO BE TESTED AT FORT WAYNE CAMPUS HIGH VOLTAGE DISCONNECTS (15KV)

1. Spyrun Disconnect Cutler Hammer

WLI

2. Anthony Disconnect Cutler Hammer

WL1

3. 500KVA West Disconnect Cutler Hammer

WLI

4. 1500KVA East Disconnect Cutler Hammer

WL1

5. Metering Section Cutler Hammer

WLI

OIL FILLED TRANSFORMERS — PAD AMOUNT

1. 500 KVA West - Cooper

2. 500 KVA East - Cooper

3. 1500 KVA West - Cooper

4. 1500 KVA East - Cooper

MEDIUM VOLTAGE CABLES (15KV)

1. Spyrun

2. Anthony

—110 Mu. 15KV — 1/0 Mu. 15KV

3.
500 KVA West Feed
3
— 2/0
15KV
4.
500 KVA West to 500 KVA East Loop
3
—2/0
15KV
5.
500 KVA East to 1500 KVA West Loop
3
— 2/0
15KV
6.
1500 KVA West to 1500 KVA East Loop
3
—2/0
15KV
7.
1500 KVA East Feed
3
— 2/0
15KV

LOW VOLTAGE CABLES (600V)

1,
500 KVA West
(20)
- 500 MCM
2.
500 KVA East
(20)
- 500 MCM
3.
1500 KVA West
(24)
- 500 MCM
4.
1500 KVA East
(24)
- 500 MCM

DRY TRANSFORMERS

1. Bldg 6 Main transformer 112.5KVA 480 x 120/208 3ph

2. R00111269, Bldg I 25KVA 480 x 120/240 1 ph

Sq. D. 25$31-1F

15KVA Isolation Transformer 208 x 120/208 3 ph GE 9T23B3091G03

150KVA 480 x 120/208 3 ph Sq. D. 150T3H

15KVA 480 x 120/208 3 ph Sq. D. 15T3H

112.5KVA 480 x 120/208 3 ph GE 9T23Q9875

45KVA 480 x 120/208 3 ph GE 9T23Q9873

150KVA 480 x 120/208 3 ph GE 9T23Q9876

150KVA 480 x 120/208 3 ph GE 9T23Q9876

112.5KVA 480 x 120/208 3ph GE 9T23Q9875

30KVA 480 x 120/208 3 ph GE 9T23Q9872

GROUNDING SYSTEM TESTING

1. Room 42 and 42A

2. Bldg 16

3. Pad Mount Transformers

LOW VOLTAGE BREAKERS 277/480V Room 42

1. South Main

2. Breaker 1

3. Breaker 2

4. Breaker 3

5. Breaker 4

6. Breaker 5

7. Breaker 6

8. Breaker 7

9. Breaker 8 10.Breaker 9 11.Breaker 13

Sq D PEF362000LSGZ Micrologic

Sq D LE36225LSG Micrologic

LE36400LSG

LE36400LSG

ME36600LSG

LE36225LSG LE36225LSG LE36225LSG LX36200

LX36175

LE36250LSG

12.Breaker 14 13.Breaker 15 14.Breaker 16 15.Breaker 17 16.Breaker 18 17.Breaker 19 18.Breaker 20 19.Breaker 22 20.North Main 21.Tie Breaker

LE36400LSG LE36400LSG LE36400LSG LE36400LSG LE36300LSG LE36400LSG LE36100LSG ME36800LSG PEF362000LSGZ PEF362000LSGZ

Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic

LOW VOLTAGE BREAKERS 120/208V (Room 42) - Bldg 1

1. North Main
30208
Westinghouse
DS-420
2. Cubical #1
30208
Westinghouse
DS-206
3. Cubical #2
30208
Westinghouse
DS-206
4. Cubical #3
30208
Westinghouse
DS-206
5. Cubical #4
30208
Westinghouse
DS-206
6. Cubical #5
30208
Westinghouse
DS-206
7. Cubical #6
30208
Westinghouse
DS-206
8. Cubical #7
30208
Westinghouse
DS-206
9. Cubical #8
30208
Westinghouse
DS-206
10. Tie Breaker
30208
Westinghouse
DS-416
11. Cubical #9
30208
Westinghouse
DS-206
12. Cubical #10
30208
Westinghouse
DS-206
13. Cubical #11
30208
Westinghouse
DS-206
14. Cubical #12
30208
Westinghouse
DS-206
15. Cubical #13
30208
Westinghouse
DS-206
16. Cubical #14
30208
Westinghouse
DS-206
17. Cubical #15
30208
Westinghouse
DS-206
18. Cubical #16
30208
Westinghouse
DS-206
19. Cubical #17
30208
Westinghouse •
DS-206
20. South Main
30208
Westinghouse
DS-420

LOW VOLTAGE BREAKERS 120/208V Bldg 16

1. Em. Generator Breaker 30208 Westinghouse DS-206

2. INFRARED SCAN

1. All Connections Transformers

1. Building 1 room 41 75KVA-480x120/208 3ph Eaton V48M28T7516CULS47

2. Trailer Feed Pad mount outside trailers 112.5KVA-12470x120/208 3ph Howard industries

3. Building 3 pad mount outside 75KVA-480x120/208 3ph Eaton V48M28T7516CU

4. Building 7 Mechanical Room A 15KVA-480x120/240 1ph Westinghouse T-6E358

5. Building 7 Mechanical Room B 15KVA-480x120/240 1ph Westinghouse T-6E358

6. Building 5 Mechanical Room 25KVA-480x120/240 1ph Square D EE25S3H

Trailer DP Panel 120/208 pad mount outside trailers

1. Siemans HFXD6 125A

2. Blank

3. Siemans HFXD6 125A

4. Siemans HFXD6 125A

5. Siemans HFXD6 125A

6. Siemans HFXD6 125A

7. Siemans HFXD6 125A

8. Siemans HFXD6 125A

9. Siemans HFXD6 125A

10. Siemans HFXD6 125A

11. Siemans HFXD6 125A

12. Siemans HFXD6 125A

13. Siemans HFXD6 125A

14. Siemans HFXD6 125A

15. Siemans HFXD6 125A

16. Siemans HFXD6 125A

17. Siemans 1200A service disconnect

Low Voltage Breakers 277/480 Room 42

1. Breaker #7 LJA36400CU44X MICROLOGIC

2. BREAKER #12 PJA36080CU44A MICROLOGIC

3. BREAKER #5 LJA36400CU44X MICROLOGIC

4. BREAKER #11 HJA36150U44XENYH2

5. BREAKER #21 JJA36250U44XENYH2

6. BREAKER #23 LJA36400CU44X MICROLOGIC

7. BREAKER #24 LJA36400CU44X MICROLOGIC

3. Room 57, Bldg 1

4. Room A155, Bldg 1

5. Bldg 16

6. Room 42A, Bldg 1

"T101"

7. Room 42, Bldg 1

"T102"

8. Room 399 Bldg 1

"T103"

9. Room 399 Bldg 1

"T104"

10. Boiler Plant�"T$201"

10. Room 111 A155 Bldg 1