Attachment 2 Ft Wayne.doc
DOC document 68 KB Posted
- Solicitation number
- 36C25020Q1016
View the file
Other files
| File | Type | Posted |
|---|---|---|
| E-103.pdf | ||
| 36C25020Q1016.docx | DOCX document | |
| Ft Wayne 01 Site Plan.pdf | ||
| E-114.pdf | ||
| E-122.pdf | ||
| E-101.pdf | ||
| E-118.pdf | ||
| E-111.pdf | ||
| E-105.pdf | ||
| E-102.pdf | ||
| E-117.pdf | ||
| E-119.pdf | ||
| E-115.pdf | ||
| E-104.pdf | ||
| E-109.pdf | ||
| Marion Campus Site Map.pdf | ||
| E-121.pdf | ||
| E-100.pdf | ||
| 1a G Table 3.2 Marion.docx | DOCX document | |
| E-120.pdf | ||
| 08 Marion VA Site Electrical Loop Schematic Model (1).pdf | ||
| E-108.pdf | ||
| E-110.pdf | ||
| E-106.pdf | ||
| E-116.pdf | ||
| 1a D Dry Type Transformer Marion.docx | DOCX document | |
| 1a H Motor Control Centers Marion.docx | DOCX document | |
| E-107.pdf | ||
| E-113.pdf | ||
| E-112.pdf |
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
FOR ELECTRICAL TESTING
ATTACIEVIENT 2
EQUIPMENT TO BE TESTED AT FORT WAYNE CAMPUS HIGH VOLTAGE DISCONNECTS (15KV)
1. Spyrun Disconnect Cutler Hammer
WLI
2. Anthony Disconnect Cutler Hammer
WL1
3. 500KVA West Disconnect Cutler Hammer
WLI
4. 1500KVA East Disconnect Cutler Hammer
WL1
5. Metering Section Cutler Hammer
WLI
OIL FILLED TRANSFORMERS — PAD AMOUNT
1. 500 KVA West - Cooper
2. 500 KVA East - Cooper
3. 1500 KVA West - Cooper
4. 1500 KVA East - Cooper
MEDIUM VOLTAGE CABLES (15KV)
1. Spyrun
2. Anthony
—110 Mu. 15KV — 1/0 Mu. 15KV
| 3. |
| 500 KVA West Feed |
| 3 |
| — 2/0 |
| 15KV |
| 4. |
| 500 KVA West to 500 KVA East Loop |
| 3 |
| —2/0 |
| 15KV |
| 5. |
| 500 KVA East to 1500 KVA West Loop |
| 3 |
| — 2/0 |
| 15KV |
| 6. |
| 1500 KVA West to 1500 KVA East Loop |
| 3 |
| —2/0 |
| 15KV |
| 7. |
| 1500 KVA East Feed |
| 3 |
| — 2/0 |
| 15KV |
LOW VOLTAGE CABLES (600V)
| 1, |
| 500 KVA West |
| (20) |
| - 500 MCM |
| 2. |
| 500 KVA East |
| (20) |
| - 500 MCM |
| 3. |
| 1500 KVA West |
| (24) |
| - 500 MCM |
| 4. |
| 1500 KVA East |
| (24) |
| - 500 MCM |
DRY TRANSFORMERS
1. Bldg 6 Main transformer 112.5KVA 480 x 120/208 3ph
2. R00111269, Bldg I 25KVA 480 x 120/240 1 ph
Sq. D. 25$31-1F
15KVA Isolation Transformer 208 x 120/208 3 ph GE 9T23B3091G03
150KVA 480 x 120/208 3 ph Sq. D. 150T3H
15KVA 480 x 120/208 3 ph Sq. D. 15T3H
112.5KVA 480 x 120/208 3 ph GE 9T23Q9875
45KVA 480 x 120/208 3 ph GE 9T23Q9873
150KVA 480 x 120/208 3 ph GE 9T23Q9876
150KVA 480 x 120/208 3 ph GE 9T23Q9876
112.5KVA 480 x 120/208 3ph GE 9T23Q9875
30KVA 480 x 120/208 3 ph GE 9T23Q9872
GROUNDING SYSTEM TESTING
1. Room 42 and 42A
2. Bldg 16
3. Pad Mount Transformers
LOW VOLTAGE BREAKERS 277/480V Room 42
1. South Main
2. Breaker 1
3. Breaker 2
4. Breaker 3
5. Breaker 4
6. Breaker 5
7. Breaker 6
8. Breaker 7
9. Breaker 8 10.Breaker 9 11.Breaker 13
Sq D PEF362000LSGZ Micrologic
Sq D LE36225LSG Micrologic
LE36400LSG
LE36400LSG
ME36600LSG
LE36225LSG LE36225LSG LE36225LSG LX36200
LX36175
LE36250LSG
12.Breaker 14 13.Breaker 15 14.Breaker 16 15.Breaker 17 16.Breaker 18 17.Breaker 19 18.Breaker 20 19.Breaker 22 20.North Main 21.Tie Breaker
LE36400LSG LE36400LSG LE36400LSG LE36400LSG LE36300LSG LE36400LSG LE36100LSG ME36800LSG PEF362000LSGZ PEF362000LSGZ
Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic Micrologic
LOW VOLTAGE BREAKERS 120/208V (Room 42) - Bldg 1
| 1. North Main |
| 30208 |
| Westinghouse |
| DS-420 |
| 2. Cubical #1 |
| 30208 |
| Westinghouse |
| DS-206 |
| 3. Cubical #2 |
| 30208 |
| Westinghouse |
| DS-206 |
| 4. Cubical #3 |
| 30208 |
| Westinghouse |
| DS-206 |
| 5. Cubical #4 |
| 30208 |
| Westinghouse |
| DS-206 |
| 6. Cubical #5 |
| 30208 |
| Westinghouse |
| DS-206 |
| 7. Cubical #6 |
| 30208 |
| Westinghouse |
| DS-206 |
| 8. Cubical #7 |
| 30208 |
| Westinghouse |
| DS-206 |
| 9. Cubical #8 |
| 30208 |
| Westinghouse |
| DS-206 |
| 10. Tie Breaker |
| 30208 |
| Westinghouse |
| DS-416 |
| 11. Cubical #9 |
| 30208 |
| Westinghouse |
| DS-206 |
| 12. Cubical #10 |
| 30208 |
| Westinghouse |
| DS-206 |
| 13. Cubical #11 |
| 30208 |
| Westinghouse |
| DS-206 |
| 14. Cubical #12 |
| 30208 |
| Westinghouse |
| DS-206 |
| 15. Cubical #13 |
| 30208 |
| Westinghouse |
| DS-206 |
| 16. Cubical #14 |
| 30208 |
| Westinghouse |
| DS-206 |
| 17. Cubical #15 |
| 30208 |
| Westinghouse |
| DS-206 |
| 18. Cubical #16 |
| 30208 |
| Westinghouse |
| DS-206 |
| 19. Cubical #17 |
| 30208 |
| Westinghouse • |
| DS-206 |
| 20. South Main |
| 30208 |
| Westinghouse |
| DS-420 |
LOW VOLTAGE BREAKERS 120/208V Bldg 16
1. Em. Generator Breaker 30208 Westinghouse DS-206
2. INFRARED SCAN
1. All Connections Transformers
1. Building 1 room 41 75KVA-480x120/208 3ph Eaton V48M28T7516CULS47
2. Trailer Feed Pad mount outside trailers 112.5KVA-12470x120/208 3ph Howard industries
3. Building 3 pad mount outside 75KVA-480x120/208 3ph Eaton V48M28T7516CU
4. Building 7 Mechanical Room A 15KVA-480x120/240 1ph Westinghouse T-6E358
5. Building 7 Mechanical Room B 15KVA-480x120/240 1ph Westinghouse T-6E358
6. Building 5 Mechanical Room 25KVA-480x120/240 1ph Square D EE25S3H
Trailer DP Panel 120/208 pad mount outside trailers
1. Siemans HFXD6 125A
2. Blank
3. Siemans HFXD6 125A
4. Siemans HFXD6 125A
5. Siemans HFXD6 125A
6. Siemans HFXD6 125A
7. Siemans HFXD6 125A
8. Siemans HFXD6 125A
9. Siemans HFXD6 125A
10. Siemans HFXD6 125A
11. Siemans HFXD6 125A
12. Siemans HFXD6 125A
13. Siemans HFXD6 125A
14. Siemans HFXD6 125A
15. Siemans HFXD6 125A
16. Siemans HFXD6 125A
17. Siemans 1200A service disconnect
Low Voltage Breakers 277/480 Room 42
1. Breaker #7 LJA36400CU44X MICROLOGIC
2. BREAKER #12 PJA36080CU44A MICROLOGIC
3. BREAKER #5 LJA36400CU44X MICROLOGIC
4. BREAKER #11 HJA36150U44XENYH2
5. BREAKER #21 JJA36250U44XENYH2
6. BREAKER #23 LJA36400CU44X MICROLOGIC
7. BREAKER #24 LJA36400CU44X MICROLOGIC
3. Room 57, Bldg 1
4. Room A155, Bldg 1
5. Bldg 16
6. Room 42A, Bldg 1
"T101"
7. Room 42, Bldg 1
"T102"
8. Room 399 Bldg 1
"T103"
9. Room 399 Bldg 1
"T104"
10. Boiler Plant�"T$201"
10. Room 111 A155 Bldg 1
File details come from the government source that posted it. Updated .