Attachment_2__Drawings.pdf
PDF 504 KB Posted
- Attached to
- Bunkhouse HVAC National Key Deer Refuge, FL
- Solicitation number
- 140FC225Q0012
About this file
This file contains architectural/mechanical drawings showing floor plans for what appears to be a bunkhouse facility. The drawings, labeled M-101, show both a main floor plan and lower floor plan at 1/4" = 1'-0" scale. The main floor includes several bunkrooms (including an ADA-compliant room), toilets, a kitchen, work room, maintenance office, laundry room, and storage areas. The drawings detail HVAC components including ductwork, condensate drains, exhaust fans (EF), and a Dedicated Outdoor Air System (DOAS). Multiple supply air diffusers (S-1) are shown with varying CFM ratings from 50-150 CFM. The lower floor plan shows a utility room and shower area.
The drawings include detailed mechanical specifications like duct sizes (ranging from 6" to 18" diameter), filter box locations, and various mechanical equipment placements. Notes indicate some elements are "NIC / BY OWNER" (Not In Contract). The drawings are copyrighted by Bilfinger Industrial Services Inc. and appear to be part of a renovation/construction project for the National Key Deer Refuge in Florida, with an estimated construction magnitude of less than $25,000.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_3__Provisions_and_Clauses.pdf | ||
| Sol_140FC225Q0012.pdf | ||
| Attachment_1__SOW.pdf | ||
| Attachment_4__Wage_Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W a s h e r
D ry e r
D ry e r
W a s h e r
UP
UP
R e fr ig e ra to r
Refrigerator
W a s h e r
D ry e r
64321
D
C
B
DINING / TV
TOILET
101B
LAUNDRY
103A
CLOSET
103B
ADA TOILET
106A TOILET
105A
TOILET
101A
BUNKROOM
BUNKROOM
ADA BUNKROOM
BUNKROOM
MAINTENANCE
OFFICE
TOILET
110A
STORAGE
110B
WORK ROOM
KITCHEN
A
4.63.8
EF
EF
EF
EF
EF
CONDENSATE
DRAIN
CONDENSATE
DRAIN
CONDENSATE
DRAIN
CONDENSATE
DRAIN
CONDENSATE
DRAIN
NIC / BY OWNER
LIFT WORK IS
NIC / BY OWNER
NOTE:
VERIFY LOCATION REQUIRING INSULATION
OF REFRIGERANT LINES
CU
CU
CAS
CAS
CAS
CAS
CAS
CAS
CAS
CAS
S-1
50 CFM
S-1
50 CFM
S-1
50 CFM
S-1
50 CFM
S-1
50 CFM
S-1
150 CFM
S-1
150 CFM
S-1
50 CFM S-1
100 CFM
S-1
100 CFM
S-1
100 CFM
S-1
50 CFM
DOAS
LVR
BCC
14"ø 14"ø
"ø 6
"ø
"ø
"ø
8"ø16"ø
"ø
18"ø16"ø
"ø
14"ø12"ø10"ø
"ø
10"ø6"ø
"ø
"ø
"ø
"ø
"ø
"ø
FILTER BOX
D
C
EF
CONDENSATE
DRAIN
UTILITY
SHOWER
001A
CAS
S-1
110 CFM
"ø
S C
A L E
S C
A L E
S C
A L E
S C
A L E
/1
S C
A L E
/3
S C
A L E
/4
S C
A L E
/8
S C
A L E
/2
S C
A L E
/1
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
T H
IS
S
E A
L
P
P L
IE
S
O N
L Y
T
O T
H
IS
D
C
U M
E N
T I
C L
A
IM
A N
R E
S P
O N
S
IB
IL
IT
F
R A
L L
O T
H E
R D
O C
U M
E N
T S
IN
S T
R U
M E
N
L A
T
IN
G T
O
IN
E N
D E
D T
O B
U
E D
F O
R A
R
T O
R P
A R
F T
O
J E
C T
Y
O T
H
O J E
C T
In te g ra te d
D e s ig n -B u ild
S e rv ic e s
B
IL
F
IN
G E
R P
R O
J E
C T
N O
C
L A
Y T
O N
R D
S
U
IT
E
B A
L L W
IN
S T
L O
U
IS
M
IS
S
O U
R I
U
S A
P H
O N
E
F
A X
F L E
N G
IN
E
E R
IN
G
C O
A
A P
P R
O V
E D
C O
N
N O
W .O
N
O
C H
E C
K E
D
D E
S
IG
N E
D
D R
A W
N
DRAWING NO.
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N B
Y D
A T
E N
O
N A
M E
D
IS
C
IP
L
IN
E
L
IC
E N
S E
N O
D A
T E
SHEET REVISION NO.
D=24x36 1
F
E
D
C
B
A
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 T
H
IS
D O
C U
M E
N T
C O
N T
A
IN
S P
R O
P R
IE
T
A R
Y I N
F O
R M
A T
IO
N
B E
L O
N G
IN
G
T O
B
IL
F
IN
G E
R I N
D U
S T
R
IA
L S
E R
V
IC
E S
I N
C
IT
S
A F
F
IL
IA
T
E D
C O
M P
A N
IE
S
A
N D
T H
E
IR
C L
IE
N T
S A
N D
S H
A L L B
E U
S
L Y
F O
R T
H E
P U
R P
O S
E F
O R
W H
IC
H
I T
W A
S S
U P
P L
IE
D
I T
S H
A L L N
O T
B E
C O
P
IE
D
R E
P R
O D
U C
E D
O
R O
T H
E R
W
IS
E U
S E
D N
O R
S H
A L L S
U C
H I N
F O
R M
A T
IO
N
B E
F U
R N
IS
H
E D
I N
W H
O L E
O R
I
R
T T
O O
T H
E R
S
E X
C E
P T
I N
A C
C O
R D
A N
C E
W
IT
H T
H E
T E
R M
S O
F A
N Y
A G
R E
E M
E N
T U
N D
E R
W H
IC
H
I T
W A
S S
U P
P L
IE
D O
R W
IT
H
T H
E P
R
IO
R W
R
IT
T E
N C
O N
S E
N T
O F
T H
E C
O M
P A
N Y
A
A
L L B
E R
E T
U R
N E
D U
P O
N R
E Q
U E
S T
B
IL
F
IN
G
E R
I N
D U
S T
R
IA
L S
E R
V
IC
E S
I N
C
A L L R
IG
H
T S
R E
S E
R V
E D
F
E
D
C
B
A
B
IL
FI
N
G E
R
IN
D U
S
TR
IA
L
S E
R V
IC
E
S
IN
C
E N
G
IN
E E
R
IN
G p ro j\ p \7
P ro j_
\7
C e n te n n ia l- D e e r K e y
E n g in e e ri n g \0
.6
D ra w in g s \0
.6
.7
R e v it M o d e l\
C e n tr a l.
rv t
/2 /2
:1
:2
P M
.0
M E
C H
A N
IC
A
L
M E
C H
A N
IC
A
L P
L A
N
C K
F
A W
J
C K
F
A W
J
C K
F
M-101
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N A
W J
-0
-1
-1
-2
M E
C H
A N
IC
A
L
C H
A R
L E
S K
F
IE
D
L E
R
U .S
F
IS
H
W
IL
D
L
IF
E S
E R
V
IC
E B
IG
P
IN
E
K E
Y
F L
O R
ID
A
N E
W B
U N
K H
O U
S E
A T
N U
T F
A R
M M
A
IN
T E
N A
N C
E C
O M
P L
E X
F
F
SCALE: 1/4" = 1'-0"M-101
FLOOR PLAN13
SCALE: 1/4" = 1'-0"M-101
LOWER FLOOR PLAN15
PLAN NORTH
RFI 8
https://app.procore.com//1293877/project/rfi/show/8878581
| 20240716 SOW NKDR Bunkhouse HVAC FINAL.pdf |
| M-101_ MECHANICAL PLAN Rev.0 markup.pdf |
File details come from the government source that posted it. Updated .