Attachment 2. Technical Proposal Questionnaire.docx

DOCX document 27 KB Posted

Attached to
Motor Control Cabinet Replacement Federal contract opportunity
Solicitation number
FA521520Q0005
Issued by
Department of the Air Force Pacific Air Forces

About this file

This document contains a technical proposal questionnaire and statement of work for a federal contract solicitation to replace motor control cabinet housings at Joint Base Pearl Harbor Hickam in Hawaii. The contractor will provide all equipment, materials, labor and costs to remove the existing motor control cabinets in the Air Freight Terminal complex and install new NEMA Type 4X enclosures that comply with NFPA 70. The contractor must have experience within the last five years designing and installing television, air cargo, or combined television and air cargo systems of comparable capacity and scope. The response must address each requirement and paragraph of the statement of work, noting any exceptions or providing recommendations on attachments.

View the file

Other files for this federal contract opportunity

Other files attached to Motor Control Cabinet Replacement, newest first.
File Type Posted
FA521520Q0005 Orginal.pdf PDF
Attachment 1. Statement of Work.doc DOC document
Attachment 3. MCC Layout and Drawing.pdf PDF
Attachment 4. MCC Photos.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNICAL PROPOSAL QUESTIONNAIRE

FOR MCC Housing Replacement

Offeror:

Solicitation Number:

Project Title:
Motor Control Center Housing Replacement
Base:
JBPHH, Hawaii
CSN:
BHC717

Statement of Work, 7 June 2019

This questionnaire shall be completed by the Offeror. All entries to this questionnaire shall be typed. The questionnaire will be used to determine the Offeror's understanding of the requirements and acceptability of the proposed equipment. Attach any exceptions to the Statement of work or recommendation/design alternatives as detailed on the last page of this questionnaire.

No.
Paragraph
Characteristic

3.1.

Will the new housings meet the requirements of NEMA ICS 6 Type 4X?

Will a new MCC be provided for the refrigerated storage area as specified?

3.1.2.

Will the existing equipment removed be disposed of by your company?

3.2.2.1.

Will the installation comply with NFPA 70 (National Electrical Code)?

3.2.2.7.
Electrical enclosures provided shall be NEMA ICS 6 Type ______

NA

Will all components operate normally after being switched between normal and generator power without requiring resetting or recalibration of the equipment?

3.6.

3.6.1.

Provide a summary of relevant experience in providing TV, air cargo systems. The project must have started operational use within the last five years and the offeror must have been the prime contractor or the prime subcontractor for the TV or air cargo system for the project to be considered relevant to this acquisition. As a minimum, include the following information for the three projects proposed as relevant experience:

Customer Company Name Installation Location Date of Customer Acceptance Is the system still in use?

Company responsible for TV or air cargo system design and installation System Type (TV, air cargo, or both) Equipment Furnished with the System Include all major components Specify capacity and speed for TVs Specify capacity for the conveyors and lifts ICS manufacturer Name of Customer Contact Telephone and Fax Number of Customer Contact E-mail of Customer Contact

The Government reserves the right to contact additional customers to obtain information that will be used to evaluate the offeror’s experience.

EXCEPTIONS/RECOMMENDATIONS/DESIGN ALTERNATIVES

Attach any exceptions taken to the Statement of Work. Outline those concerns in detail. Your exceptions will be reviewed to determine acceptability.

Are exceptions taken?

Number of pages attached: ______________________________________

Attach any recommendations or design alternatives you feel may enhance operation, maintainability, or reduce system cost. Your recommendations and design alternatives will be reviewed to determine acceptability.

Recommendations/design alternatives attached?

Number of pages attached: ______________________________________

We have read the requirements of the Statement of Work and will comply with all paragraphs as written, with exception taken only to those items indicated on the attached exception sheet.

__________________________________________________
Offeror's SignatureDate

TYPED NAME:

COMPANY NAME:

ADDRESS:

PHONE:

FAX:

E-MAIL:

TPQ for Charleston Cover Purchase Description - Page 4 of 5 Attachment 2 Technical Proposal Questionnaire - Page 2 of 3 image1.wmf