Attachment 2.pdf

PDF 175 KB Posted

Attached to
Pump & Treat Services of Contaminated Groundwater
Solicitation number
300000268185761
Issued by
Missouri

About this file

This is a system monitoring form for the Valley Park TCE Site Groundwater Extraction System, a remediation operation focused on managing contaminated groundwater. The form provides a standardized inspection checklist and data collection template for personnel conducting routine monitoring and maintenance of the extraction and treatment system. Key components monitored include extraction well operations, flow rates, water levels, antiscalant metering systems, sediment bag filters, air stripper performance, and variable frequency drive (VFD) settings. The form tracks physical component readings against typical operating ranges, such as extraction well flow rates of 178 to 182 gpm, water level depths of 35 to 50 feet below top of casing, and air stripper pressure readings of 35 to 42 inches of water. Site personnel are required to conduct daily system status checks and monthly maintenance tasks including antiscalant level verification, air stripper tray inspections, monitoring well gauging at locations MW-55 and MW-56, and equipment runtime documentation through the SiteLink Controls remote monitoring system.

The form establishes specific setpoints and control parameters for automated operation, including pump on levels at 50 feet below top of casing, dosing pump settings at 50 percent manual setpoint with 200 gpm automatic setpoint, and VFD frequency commands between 37 to 42 Hz. Inspectors must verify that appropriate indicator lights are illuminated and switch positions are set to designated AUTO/OFF configurations to ensure proper system function. The document was last revised on March 13, 2020, and serves as the operational record for ongoing groundwater remediation activities at this contaminated site, supporting both compliance documentation and system optimization through continuous performance monitoring.

View the file

Other files

File Type Posted
STATE 0000000524SL-01.docx DOCX document
Attachment 1.pdf PDF
STATE 0000000524SL.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Inspected: ___________________ System Status At Arrival: [ ] running [ ] stopped [ ] alarmed

Time Inspected: ___________________ [ ] running [ ] stopped [ ] alarmed

Inspected By: ______________________

Check Physical Components

Component Reading Units (typical operating range)

Extraction Well and Flow Meter

E+H Flow Meter gpm (178 to 182 gpm)

E+H Flow Meter Kgl

E+H Flow Meter gal (use the plus sign only)

Extraction Well Water Level ft below TOC (35 to 50 ft.)

Extraction Well Pressure Gauge psi (8 to 15 psi)

Antiscalant and Metering Pump

Metering Rate gal/day (~0.03 gal/day)

Pump Pressure bar (~3.5 bar)

50:50 Antiscalant Volume gal

Undiluted Antiscalant Onhand drums

Sediment Bag Filters

Pre Bag Filter Pressure psi (5 to 9 psi)

6591A-pre psi (3 to 9 psi)

6591A-post psi (2.5 to 7 psi)

6591A-pre psi (3 to 9 psi)

6591B-post psi (2.5 to 7 psi)

Post Bag Filter Pressure psi (5 to 7 psi)

Capsu-Photohelic Reading (black) (DP-10) in H2O

Capsu-Photohelic Gauge Setpoint (red) (DP-10) ~ 300 in H2O Note: 300 in H2O = 11 psi

Air Stripper Blower

Air Stripper Pressure in H2O (35 to 42 in H2O)

Air Stripper Input Flow cfm x 10 (350 - 450 cfm x10)

TECO-Westinghouse Variable Frequency Drive (VFD)

VFD Freq. Cmd Hz (37 to 42)

VALLEY PARK TCE SITE

GROUNDWATER EXTRACTION SYSTEM MONITORING

System Status When Leaving:

Form Revised 3/13/2020

Control Panel and PLC

Site Walk-Around, Well Gauging, and Other Items

Check Each Visit Check Monthly (first week of month)

[ ] Site walk-around [ ] Check antiscalant level

[ ] Check outfall in storm grate [ ] Check air stripper trays

[ ] Drain air stripper stack [ ] Tighten Fernco fittings on air stripper trays

[ ] Gauge monitoring wells

MW-55

MW-56

SiteLink Controls (https://sitelink.newterra.com/)

Flow Meter Readings

FM-10 Flowrate gpm (178 to 182 gpm)

FM-10 Total Volume gal.

Water Level (LC-10) Control

Water over LC-10 ft.

Water Level ft. below TOC

LC-10 Position ft. below TOC (58 ft)

Low Water Well (Low SP) ft. below TOC (56 ft)

Pump On Level (ON SP) ft. below TOC (50 ft)

Dosing Pump (DP-CH) Setpoints

Manual SP % (50 %)

Automatic SP gpm (200 gpm)

Runtimes

VB-SVE & FAN HRS 0 hrs

ASP-10 Blower HRS hrs

P-10 WELL HRS hrs

DP-VLS PUMP HRS 0 hrs

Notes

Depth to Water

(ft btoc)

Total Depth

(ft btoc)

Verify: Are ASP-10 BLOWER-ON and VFD P-10 ON lights illuminated red and all others are off?

[ ] yes [ ] no, explain:

Verify: Are switch positions: AUTO, OFF, OFF, OFF, AUTO [ ] yes [ ] no, explain:

Form Revised 3/13/2020

File details come from the government source that posted it. Updated .