ATTACHMENT 2 - 100 Bid Document Drawings.pdf
PDF 18 MB Posted
- Solicitation number
- 36C24826Q0105
About this file
This document is a comprehensive set of construction documents for a renovation project at the Lake Nona VA Medical Center in Orlando, Florida, with project number 675-23-105. The project involves renovating various spaces across multiple areas including a pharmacy, computer tomography room, medical media area, Office of Information and Technology (OIT), tool crib, and warehouse spaces across the 1st and 4th floors of Building 1.
The renovation scope includes architectural, structural, mechanical, plumbing, and electrical work, with a focus on maintaining the facility's operational status during construction. Key design specifications include using Construction Type IB, fully sprinklering the building, and adhering to multiple building codes including the 2018 International Building Code. The project requires strict infection control measures, including maintaining negative air pressure, constructing critical barriers, and implementing comprehensive cleaning protocols. The design team includes AESUS Design Group as the primary architectural and engineering firm, with Simply Structural providing structural engineering services. The total renovation area is approximately 8,272 square feet, with work concentrated on modernizing and upgrading various medical and administrative spaces within the VA Medical Center.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ATTACHMENT 8 - Past Performance Questionnaire.docx | DOCX document | |
| ATTACHMENT 9 - Base Offer Price Breakdown.xlsx | XLSX spreadsheet | |
| ATTACHMENT 7 - EMR.pdf | ||
| ATTACHMENT 1 - 100 Bid Document Specifications.pdf | ||
| ATTACHMENT 4 - DBA Wage Determination 01.02.2026.pdf | ||
| ATTACHMENT 5 - Limitation of Subcontracting Certificate.pdf | ||
| 36C24826Q0105_1.docx | DOCX document | |
| ATTACHMENT 6 - Specialized Experience Form.pdf | ||
| Solicitation 36C24826Q0105.docx | DOCX document | |
| ATTACHMENT 3 - 100 Bid Document Narratives.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DX
A3-301
X
XX
X
DETAIL FLAG NUMBER
DOOR NUMBER
AE-501
BUILDING SECTION CUT
OTHER SECTION CUT
SHEET WHERE APPEARS (TYPICAL)
AE-301
AA
SHEET WHERE APPEARS
ELEVATION NUMBER
SHEET WHERE APPEARS
x x x x
EXISTING COLUMN CENTER LINEA
X
WINDOW TAG
AE-301
AA
AE-301
AA
ELEVATION NUMBER
AE-710
4 2
DASHED LINE
AROUND
AREA DETAILED
PLAN OR DETAIL NUMBERX
NOTE: IN ADDITION TO THE FOLLOWING INFECTION CONTROL MEASURES OF ICRA
CLASS & PERMIT LEVEL IV, THE CONTRACTOR SHALL REVIEW THE VA SAFETY-QUALITY
CONTROL-INFECTION CONTROL DOCUMENTS IN THE SPECIFICATIONS. THE AE WILL
PROVIDE A FORM FOR THE CONTRACTOR TO FILL OUT
DURING CONSTRUCTION:
A. ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
B. COMPLETE ALL CRITICAL BARRIERS I.E. SHEET ROCK, PLYWOOD, PLASTIC,
TO SEAL AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE
METHOD (CART WITH PLASTIC COVERING AND SEALED CONNECTION TO
WORK SITE WITH HEPA VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE
CONSTRUCTION BEGINS.
C. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA
EQUIPPED AIR FILTRATION UNITS. PROVIDE NEGATIVE AIR PRESSURE
MONITOR.
D. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY.
E. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH
THIS ROOM SO THEY CAN BE VACUUMED USING A HEPA VACUUM CLEANER
BEFORE LEAVING WORK SITE OR THEY CAN WEAR CLOTH OR PAPER
COVERALLS THAT ARE REMOVED EACH TIME THEY LEAVE THE WORK SITE.
F. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT
IS INSPECTED BY A SAFETY OFFICER AND INFECTION CONTROL
COORDINATOR AND THOROUGHLY CLEANED BY THE ENVIRONMENTAL
MANAGEMENT SERVICES.
UPON COMPLETION OF PROJECT:
A. REMOVE BARRIER MATERIAL CAREFULLY TO MINIMIZE SPREADING OF DIRT
AND DEBRIS ASSOCIATED WITH CONSTRUCTION.
B. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY
COVERED CONTAINERS.
C. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS
SOLID LID.
D. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.
E. WET MOP AREA WITH DISINFECTANT.
F. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE WORK IS BEING
PERFORMED.
Approved: Associate Director
Approved: Chief Facilities
Management
Approved: Manager / Engineer
Approved: Director
Approved: Union representative
Approved: Safety Officer
EQ-X
CPT1
W-X
E
EA EACH
E EAST
EWC ELECTRIC WATER COOLER
ELEC ELECTRIC (AL)
EL ELEVATION
ELEV ELEVATOR
EMER EMERGENCY
ENGR ENGINEER
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
ETR EXISTING TO REMAIN
EXP EXPANSION
EXP BT EXPANSION BOLT
EJ EXPANSION JOINT
EXP EXPOSED
EXT EXTERIOR
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
F
FWC FABRIC WALL COVERING
FT FEET, FOOT
FGL FIBERGLASS
FIN FINISH
FIN GR FINISH GRADE
FDV FIRE DEPARTMENT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FHC FIRE HOSE CABINET
FP FIREPROOF
FIXT FIXTURE
FLASH FLASHING
FLEX FLEXIBLE
FLR FLOOR
FD FLOOR DRAIN
FLUOR FLUORESCENT
FTG FOOTING
FDTN FOUNDATION
FRMG FRAMING
FURN FURNACE, FURNITURE
G
GA GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GL GLASS
GL BLK GLASS BLOCK
GB GRAB BAR
GR GRADE
GRAN GRANITE
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GUT GUTTER
GYP BD GYPSUM BOARD
H
HNDRL HANDRAIL
HDW HARDWARE
HDWD HARDWOOD
HD HEAD
HVAC HEATING, VENTILATING, AIR CONDITIONING
HT HEIGHT
HPT HIGH POINT
HC HOLLOW CORE
HM HOLLOW METAL
HORIZ HORIZONTAL
HB HOSE BIBB
HOSP HOSPITAL
HR HOUR
I
IN INCH
INFO INFORMATION
ID INSIDE DIAMETER
INSUL INSULATED,INSULATION
INT INTERIOR
J
JAN JANITOR
JT JOINT
K
KPL KICKPLATE
KIT KITCHEN
KB KNEE BRACE
L
LAB LABORATORY
LAM LAMINATE
LC LAUNDRY CHUTE
LV LAVATORY
LT LIGHT
LD LINEAR DIFFUSER
L CL LINEN CLOSET
LL LIVE LOAD
LLV LONG LEG VERTICAL
LPT LOW POINT
M
MACH MACHINE
MH MANHOLE
MFD MANUFACTURED
MFR MANUFACTURER
MRB MARBLE BASE
MRF MARBLE FLOOR
MKR BD MARKER BOARD
MO MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDICAL
MC MEDICINE CABINET
MEMB MEMBRANE
MTL METAL
MIN MINIMUM, MINUTE
MISC MISCELLANEOUS
MOD MODIFIED
MLDG MOLDING
N
NAT FIN NATURAL FINISH
NOM NOMINAL
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NO NUMBER
O
OFF OFFICE
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
OPH OPPOSITE HAND
ORCH ORCHESTRA
ORN ORNAMENTAL
OD OUTSIDE DIAMETER
OH OVERHANG, OVERHEAD
OF/CI OWNER FURNISHED/
CONTRACTOR INSTALLED
O OXYGEN
P
P PAINT
PR PAIR
PNL PANEL
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PERF PERFORATED
PC PIECE
PLAM PLASTIC LAMINATE
PLAS PLASTIC, PLASTER
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PCC PRECAST CONCRETE
PREFAB PREFABRICATE
PREFIN PREFINISH
PROD PRODUCTION
Q
QTY QUANTITY
QT QUARRY TILE
A
AFF ABOVE FINISHED FLOOR
ACST ACOUSTIC (AL)
ACT ACOUSTICAL CEILING TILE
APC ACOUSTICAL PANEL CEILING
AWP ACOUSTICAL WALL PANEL
AWT ACOUSTICAL WALL
ADJ ADJUSTABLE
A/C AIR CONDITIONING
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AB ANCHOR BOLT
AL ANGLE
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASPH ASPHALT
ASSY ASSEMBLY
AUTO AUTOMATIC
AWN AWNING
B
BALC BALCONY
BSMT BASEMENT
BM BEAM, BENCHMARK
BR BEDROOM
BLKG BLOCKING
BD BOARD
BOT BOTTOM
BRKT BRACKET
BRK BRICK
B CL BROOM CLOSET
BLDG BUILDING
BLT IN BUILT-IN
BUR BUILT-UP ROOFING
C
CAB CABINET
CPT CARPET
CSMT CASEMENT
CI CAST IRON
CB CATCH BASIN
CLG CEILING
CEM CEMENT
CL CENTER LINE
CER CERAMIC
CT CERAMIC TILE
CO CLEANOUT, CASED OPENING
CLR CLEAR, COLOR
CLO CLOSET
COL COLUMN
CMPST COMPOSITE
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COTR CONTRACTING OFFICER
CJ CONTROL JOINT
COP COPING
CU COPPER
CG CORNER GUARD
CORR CORRIDOR
CNTR COUNTER
CSK COUNTER SUNK
D
DMPF DAMPPROOFING
DL DEAD LOAD
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DR DOOR, DRAIN
DH DOUBLE HUNG
DN DOWN
DS DOWNSPOUT
DWR DRAWER
DWG DRAWING
DF DRINKING FOUNTAIN
DUPL DUPLICATE
R
R RADIUS, RISER
RWD REDWOOD
REF REFERENCE, REFRIGERATOR
REINF REINFORCE
REQD REQUIRED
RB RESILIENT BASE
RF RESILIENT FLOORING
RA RETURN AIR
REV REVISION
RD ROOF DRAIN
RM ROOM
RO ROUGH OPENING
RS ROUGH SAWN
S
SCHED SCHEDULE
SECT SECTION
SHTHG SHEATHING
SHT SHEET
SHV SHELVING
SIM SIMILAR
S SOUTH
SP FIN SPECIAL FINISH
SPEC SPECIFICATION
SQ SQUARE
SF SQUARE FEET
SST STAINLESS STEEL
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STOR STORAGE
STRUCT STRUCTURAL
S4S SURFACED FOUR SIDES
SUSP SUSPEND
SW SWITCH
SYMM SYMMETRICAL
T
TK BD TACKBOARD
TEL TELEPHONE
TV TELEVISION
TMPD TEMPERED
TEMP TEMPORARY
TER TERRAZZO
THK THICKNESS
TPD TOILET PAPER DISPENSER
T&G TONGUE AND GROOVE
TOS TOP OF SLAB, STEEL
T TREAD
TYP TYPICAL
U
UC UNDERCUT
UNFIN UNFINISH
UNO UNLESS NOTED OTHERWISE
V
VAC VACUUM
VR VAPOR RETARDER
VNR VENEER
VP VENEER PLASTER
VIF VERIFY IN FIELD
VERT VERTICAL
VEST VESTIBULE
VCT VINYL COMPOSITION TILE
VWC VINYL WALL COVERING
W
W CAB WALL CABINETS
WC WALL COVERING, WATER CLOSET
WP WATERPROOFING, WEATHER
PROOF, WORKING POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
W WEST
WF WIDE FLANGE
WDW WINDOW
W/ WITH
W/O WITHOUT
WD WOOD
WDP WOOD PANELING
13800 Veterans Way
Florida Department of Veterans Affairs
KEYED NOTE
WALL TYPE
X
X WINDOW TREATMENT TYPE
EQUIPMENT
INTERIOR FINISH TYPE
FURNITURE, FIXTURE, EQUIPMENT
CONTRACT LIMIT LINE
COLUMN CENTER LINE
NEW WALL
DEMOLITION
EXISTING WALL
NORTH
APPROVED FOR CONSTRUCTION
Project No: 675-23-105
Orlando, FL 32827
DESIGN TEAM
ABBREVIATIONS
OWNER
CODE REFERENCES
BUILDING CODE:
2018 INTERNATIONAL BUILDING CODE
2018 EXISTING BUILDING CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL FIRE CODE
ACCESSIBILITY CODE & GUIDELINES:
ABAAS & BFDG
MECHANICAL CODE:
2018 INTERNATIONAL MECHANICAL CODE
PLUMBING CODE:
2018 INTERNATIONAL PLUMBING CODE
ELECTRICAL CODE:
2018 INTERNATIONAL ELECTRICAL CODE
PROJECT DESCRIPTION
FACILITY MAP
SYMBOL LEGEND
BUILDING INFORMATION
DESCRIPTION OF BUILDING: EXISTING BUILDING
PROJECT INCLUDES ARCHITECTURAL, STRUCTURAL,
MECHANICAL, PLUMBING, AND ELECTRICAL.
GENERAL NOTES
VICINITY MAP
INFECTION CONTROL MEASURES
SHEET INDEX
DESCRIPTIONSYMBOL
RENOVATE VARIOUS SPACES AT LAKE NONA 675-23-105
ORLANDO VA MEDICAL CENTER
Department of Veterans Affairs
Architect
MPE Engineers
1050 E. Southern Ave. Suite 5, Tempe, Arizona 85282
AESUS Design Group
1053 10th Ave, San Diego, CA 92101
San Diego, CA 92101
Davy Architecture
Orlando Gonzales (ogonzales@aesusdesign.com)
480-454-2861
Davyarchitecture.com
619-238-3811
Structural Engineers
NORTH
PROJECT AREA
BUILDING OCCUPANCY:
INSTITUTIONAL GROUP I-2 PER IBC 308.3
CLINIC/AMBULATORY CARE - BUISINESS "B"
OFFICES & LOCKERS - BUSINESS - "B"
ACCESSORY USE = STORAGE S-1
CONSTRUCTION TYPE:
CONSTRUCTION TYPE: IB (222)
FIRE RESISTANCE IN ACCORDANCE WITH IBC TABLES 601 & 602
FULLY SPRINKLERED
BUILDING AREA:
ACTUAL ALLOWABLE (IBC 506.2)
OVERALL EXISTING 4TH FLOOR 189,500 SF
4TH FLOOR RENOVATION AREA 8,272 SF
BUILDING HEIGHT:
ACTUAL ALLOWABLE (TABLE 504.3)
4TH FLOOR HEIGHT 20 FT
EXISTING BUILDING STORIES 5
MINIMUM NUMBER OF EXITS (TABLE 1006.3.2)
OCCUPANT LOAD PER STORY MIN EXITS PER STORY
1-500 2
EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2)
I-2 OCCUPANCY WITH SPRINKLERS = 200 FEET
DEAD END CORRIDORS (IBC 1020.4)
I-2 OCCUPANCY WITH SPRINKLERS = 20 FEET
PROJECT SITE
NFPA
NFPA 101 LIFE SAFETY CODE
NFPA NATIONAL FIRE CODES
NFPA 900 (OSHA)
Orlando VA Medical Center
A.
B.
C.
D.
E.
F.
ANY CHANGES MUST BE APPROVED BY COR BEFORE DOING ANY
ADDITIONAL WORK. WORK SCHEDULE TO BE PERFORMED DURING
REGULAR DAY SHIFT HOURS (8AM-4:30PM) ANY WORK OUTSIDE OF
REGULAR SCHEDULE REQUIRES APPROVAL FROM COR.
COORDINATE STAGING AREA WITH COR, AND FIND INTERIOR
COVERED STORAGE ON SITE FOR MATERIALS THAT MUST BE
PROTECTED FROM ELEMENTS - COORDINATE WITH COR.
PERFORM WORK IN ACCORDANCE WITH VHA DIRECTIVE 2004-012
SAFETY AND HEALTH DURING CONSTRUCTION ACTIVITIES AND VHA
DIRECTIVE 7701 OCCUPATIONAL SAFETY AND HEALTH (OSH) .
WORK PERFORMED FOR THIS PROJECT MAY INTERRUPT SERVICE TO
ADJACENT AREAS AT TIMES BUT WILL NOT INTERRUPT OVERALL
FACILITY OPERATION. SEE ELECTRICAL FOR POWER INTERRUPTION
AND OUTAGE REQUIREMENTS.
CONTRACTOR TO VERIFY ALL DETAILS AGAINST EXISTING
CONDITIONS PRIOR TO PURCHASE OF EQUIPMENT AND PRIOR TO
CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR BRINGING ANY
DISCREPANCIES IN PLANS AND EXISTING SITE CONDITIONS TO
IMMEDIATE ATTENTION OF CONTRACTING OFFICER
REPRESENTATIVE.
CONTRACTOR SHALL PERFORM ALL WORK AND PROVIDE ALL
MATERIALS IN ACCORDANCE WITH VA MASTER CONSTRUCTION
SPECIFICATIONS, WHICH CAN BE FOUND AT
HTTP://WWW.CFM.VA.GOV/TIL/. WHERE DISCREPANCIES ARE FOUND
THE MORE STRINGENT SHALL APPLY.
G. NOT ALL KEYNOTES ARE ON ALL SHEETS.
730 N. 52 nd
Street, Suite 105
Phoenix, AZ 85008
Office: (602) 443-0303 Ext. 101
Simply Structural
Mike Wilda (mwilda@simplystructural.com)
GI000 COVER SHEET
ARCHITECTURAL
GI002 ADA GRAPHICS
GI003 EXISTING SITE PLAN
GI004 OVERALL PLAN - BUILDING 1 & BUILDING 9 - 1ST FLOOR
GI005 OVERALL PLAN - BUILDING 1 - 4TH FLOOR
GI001
AE101 1ST FLOOR PLANS - PHARMACY
AE102 1ST FLOOR PLANS - COMPUTER TOMOGRAPHY
AE103 4TH FLOOR PLANS - MEDICAL MEDIA
AE104 4TH FLOOR PLANS - O.I.T.
AE105 1ST FLOOR PLANS - DOMICILIARY STORAGE
AE106 WAREHOUSE FLOOR PLANS - ADD ALT 1
AE201 INTERIOR ELEVATIONS
AE501 DETAILS
AE502 DETAILS
STRUCTURAL
S101 GSN
S201 PLANS
S301 TYPICAL AND FOUNDATION DETAILS
S302 FRAMING DETAILS
GENERAL
SYMBOLS AND ABBREVIATIONS
THE SCOPE OF WORK SHALL BE DEMOLISH, REDESIGN AND RENOVATION OF
VARIOUS SPACES LOCATED AT LAKE NONA VAMC. SPACES INCLUDE: PHARMACY,
MEDICAL MEDIA, DOM STORAGE, OIT OFFICE, AND WAREHOUSE SPACES.
THIS WORK SHALL INCLUDE BUT NOT BE LIMITED TO ARCHITECTURAL, STRUCTURAL,
MECHANICAL, PLUMBING, & ELECTRICAL.
AE601
DOOR SCHEDULE, NOTES, DETAILS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
GI000
COVER SHEET
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseDESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10
RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 VETERANS WAY ORLANDO, FL 32827
675-23-105
VARIOUS
08/04/2023 AESUSRevisions: Date:
321 4 5 6
90% CONSTRUCTION
DOCUMENTS
AESUS
MECHANICAL/PLUMBING
M001 MECHANICAL SYMBOLS AND ABBREVIATIONS
M101 MECHANICAL 1ST FLOOR PLANS
M102 MECHANICAL 4TH FLOOR PLANS
P001 PLUMBING SYMBOLS AND ABBREVIATIONS
P101 PLUMBING PLANS
ELECTRICAL
ED-101 ELECTRICAL DEMOLITION PLANS
ED-102 ELECTRICAL DEMOLITION PLANS - WAREHOUSE
EL-101 ELECTRICAL LIGHTING PLANS
EL-102 ELECTRICAL LIGHTING PLANS - WAREHOUSE
E-001 SYMBOLS AND ABBREVIATIONS
EP-101 ELECTRICAL POWER PLANS OVERALL PLANS - LEVEL 1 & 4
EP-102 ELECTRICAL POWER PLANS
F101 FIRE PLANS
EP-103 ELECTRICAL POWER PLANS - WAREHOUSE
EP-701 ELECTRICAL PANEL SCHEDULES
M501 MECHANICAL DETAILS & CONTROL DIAGRAMS
EP-401 ELECTRICAL DETAILS
AE503 TYPICAL CEILING DETAILS
AE504 TYPICAL CEILING DETAILS
AE505 SUSPENDED ACOUSTIC TILE CEILING DETAILS
AE506 SUSPENDED GYPSUM BOARD CEILING DETAILS
AE507 SUSPENDED GYPSUM BOARD CEILING DETAILS
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, and, Sustainable Design group
FEC
DOOR IDENTIFICATION
REFER TO DOOR
SCHEDULE
WINDOW IDENTIFICATION
REFER TO WINDOW
SCHEDULE
KEYNOTE
IDENTIFICATION
WALL TYPE, REFER
TO WALL TYPES
LEGEND
FINISH IDENTIFICATION
REFER TO FINISH
SCHEDULE
REVISION
REFERENCE
DIMENSION LINE TO
CENTERLINE
LEVEL IDENTIFICATION
HIDDEN, FUTURE, OR
EXISTING TO BE REMOVED
MATCHLINE
ADA CLEARANCE
PROPERTY LINE
INTERIOR ELEVATION
REFERENCE, TYP.- --
CLR
DIM
EQUIPMENT
IDENTIFICATION
GENERAL IDENTIFICATION TAGS
ROOM IDENTIFICATION TAGS
VIEW REFERENCE SYMBOLS
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
FLOOR PLAN
REFERENCE
LOCATION SYMBOLS
DIMENSION TO ELEVATION
GRID BUBBLE AND LINE
DIMENSIONS
LINE STYLES
LEVEL NAME
x' - x"
AREA OF WORK
DIMENSION TO FACE
OF STUD U.O.N.
INDICATES CLEAR
DIMENSION REQUIRED
W
H D
CASEWORK TAG
CASEWORK IDENTIFICATION
CASEWORK DEPTH
(INCHES)
CASEWORK HEIGHT
(INCHES)
CASEWORK WIDTH
(INCHES)
COMMENT
NORTH ARROW
EXISTING GRID BUBBLE
AND LINE
SIM
DIM
TOTAL
OCCUPANT LOAD
ROOM
OCCUPANT LOAD
FACTOR
ROOM AREA
ROOM NUMBER
ROOM NAME
OCCUPANCY TYPE
WALL SECTION
NUMBER
SHEET NUMBER
INDICATES SIMILAR
CONDITION
SIM
BUILDING SECTION
NUMBER
SHEET NUMBER
INDICATES SIMILAR
CONDITION
BUILDING
ELEVATION NUMBER
SHEET NUMBER
ROOM AREA
ROOM NUMBER
ROOM NAME
100 SF
ROOM
ARCHITECTURAL PLAN LEGEND
EXISTING WALL TO REMAIN
PARTIAL HEIGHT WALL
NON RATED PARTITION
1 HOUR FIRE RATED WALL
2 HOUR FIRE RATED WALL
SMOKE WALL
DOOR AND FRAME ASSEMBLY,
REFERENCE DOOR SCHEDULE -/--
WINDOW AND FRAME ASSEMBLY,
REFERENCE DOOR SCHEDULE -/--
ARCHITECTURAL CEILING PLAN LEGEND
2 X 4 SUSPENDED ACOUSTICAL
CEILING SYSTEM
2 X 2 SUPPLY AIR REGISTER
2 X 2 RETURN AIR REGISTER
2 X 2 EXHAUST AIR REGISTER
LINEAR DIFFUSER
30" x 42" ACCESSIBLE
CLEAR SPACE
5' - 0" ACCESSIBLE CLEAR
TURNING SPACE
GYPSUM CEILING
PLASTER CEILING
PENDANT LIGHT FIXTURE,
PER SCHEDULE
RECESSED CAN LIGHT FIXTURE,
PER SCHEDULE
24" X 24" LIGHT FIXTURE,
PER SCHEDULE
24" X 48" LIGHT FIXTURE,
PER SCHEDULE
12" X 48" LIGHT FIXTURE,
PER SCHEDULE
SURFACE MOUNTED LIGHT
FIXTURE, PER SCHEDULE
ILLUMINATED EXIT SIGN, REFERENCE
ELECTRICAL DRAWINGS
S
SMOKE DETECTOR, REFERENCE
ELECTRICAL DRAWINGS
OS
OCCUPANCY SENSOR, REFERENCE
ELECTRICAL DRAWINGS
SYMBOL LEGEND
AP
SECURITY CAMARA, REFERENCE
ELECTRICAL DRAWINGS
ACCESS POINT, REFERENCE
ELECTRICAL DRAWINGS
SMOKE DETECTOR, REFERENCE
FIRE PROTECTION DRAWINGS
S
SPEAKER, REFERENCE
ELECTRICAL DRAWINGS
FIRE EXTINGUISHER CABINET
PER DETAIL:
2 X 2 SUSPENDED ACOUSTICAL
CEILING SYSTEM
CARD READER
CMU WALL
CR
DEMOLITION NOTES
A. REFER TO SHEET G-001 FOR ARCH DWG REFERENCE AND MATERIAL SYMBOLS AS WELL AS ABBREVIATIONS USED ON THIS SET OF
DRAWINGS.
B. THIS AREA OF WORK CONTAINS BUILDING INFRASTRUCTURE, WHICH IS CRITICAL TO THE ONGOING OPERATIONS OF THE HOSPITAL. ALL UTILITY WORK SHALL HAVE A PRE-CONSTRUCTION MEETING AND SCHEDULED PRIOR TO ANY DEMOLITION OR SHUT-DOWNS.
C. DEMOLITION OPERATIONS ARE TO PROCEED WITH NECESSARY PREPARATIONS AND PRECAUTIONS TAKEN TO PROTECT ITEMS AND FINISHES TO REMAIN. THE CONTRACTOR SHALL COORDINATE DEMOLITION OPERATIONS WITH THE VA AND REACH SPECIFIC
DEPARTMENTS PRIOR TO ANY DEMO WORK.
D. REMOVE AND DISPOSE ALL DEMOLISHED MATERIALS OFF SITE WHICH ARE NOT SCHEDULED TO REMAIN, BE RELOCATED, OR BECOME THE
PROPERTY OF THE OWNER.
E. ANY PIPE REMAINING AFTER DEMOLITION MUST BE IDENTIFIED AT ITS TERMINATION WITH A LABEL BY THE CONTRACTOR.
F. DO NOT PENETRATE THE FLOOR FLAB WITHOUT COORDINATING WITH STRUCTURAL REQUIREMENTS.
G. UNLESS SPECIFICALLY NOTED OTHERWISE, EXISTING FLOOR AND CEILING MATERIALS SHALL REMAIN IN PLACE. PROTECT FLOORS AND
CEILINGS FROM DAMAGE DURING DEMOLITION AND RENOVATION WORK.
H. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY
ACTUAL EXISTING CONDITIONS AND NOTIFY THE VA OF ANY DISCREPANCIES.
I. DEMO WORK SHALL BE DONE IN A MANNER WHICH WILL NOT CAUSE UNNECESSARY INCONVENIENCE OR DANGER TO USERS OF THE PREMISES AND ADJACENT AREAS AND NOT INTERFERE WITH ITS OPERATION. ANY DEMO WORK TO BE PERFORMED MUST BE PLANNED IN
ADVANCE AND APPROVED BY THE OWNER.
J. ANY EQUIPMENT, MATERIALS AND SUPPLIES TEMPORARILY REMOVED FOR THE PURPOSE OF PROTECTION SHALL BE REPLACED IN ORIGINAL LOCATIONS AND CONDITIONS. ANY MATERIAL DAMAGED SHALL BE REPLACED WITH NEW MATERIALS OF LIKE AND QUANTITY.
K. REFER TO AND COORDINATE WITH MECHANICAL AND ELECTRICAL DWGS. FOR ADDITIONAL DEMOLITION INFORMATION.
L. ALL MATERIALS INDICATED TO BE REMOVED SHALL BE DISPOSED OF AND REMOVED FROM THE SITE. COORDINATE WITH THE COR, THE REMOVAL AND FINAL DISPOSAL LOCATION/DESTINATION(S) OF DEMOLITION. THE GC SHALL PROVIDE MONTHLY NEMA TRACKING
REPORTS.
M. ALL REMOVED MATERIALS AND EQUIPMENT WHICH IS SALVAGEABLE SHALL REMAIN THE PROPERTY OF THE OWNER. DELIVER SUCH SALVAGED MATERIALS AND EQUIPMENT ON THE PREMISES AS DIRECTED BY THE COR AND NEATLY STORE THEM AND PROTECT FROM DAMAGE. ALL OTHER MATERIAL AND EQUIPMENT SHALL BE REMOVED FROM THE PROJECT SITE AT THE CONTRACTOR'S EXPENSE, SEE
SPECIFICATIONS.
N. THE GOVERNMENT SHALL REMOVE THE FOLLOWING EXISTING ITEMS PRIOR TO ANY DEMO WORK. THE CONTRACTOR SHALL NOTIFY THE OWNER 72 HOURS IN ADVANCE OF ANY SCHEDULED DEMO WORK IN THE AREA OF THE ITEM TO ALLOW REMOVAL BY THE OWNER:
FURNITURE, MEDICAL AND OTHER EQUIP., STORAGE ITEMS AND PERSONAL BELONGINGS.
O. PATCH/REPAIR ALL ELEMENTS THAT ARE TO REMAIN AND ARE DAMAGED FROM THE DEMO WORK, BACK WITH CONSTRUCTION TO MATCH
EXISTING CONDITIONS.
P. IN WALLS TO BE REMOVED, STRIP ALL EXISTING ELECTRICAL WIRING TO NEAREST ACTIVE J-BOX & CONDUIT.
Q. INTERIM LIFE SAFETY MEASURES MAY APPLY. COORDINATE WITH HOSPITAL'S SAFETY OFFICER AND COR.
R. MATERIALS AND EQUIPMENT ACCRUING FROM WORK REMOVED AND FROM DEMOLITION OF BUILDING OR STRUCTURES, OR PARTS
THEREOF, SHALL BE DISPOSED PER SPECIFICATION SECTION 01 74 19.
S. REMOVE ALL EXISTING ABANDONED CONDUITS, WIRES, AND PIPES ASSOCIATES WITH THIS CONTRACT.
T. DIMENSIONS ON DEMO PLANS TO BE VERIFIED WITH CONDITIONS ON SITE BY G.C.
GENERAL NOTES
A. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE. LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. THE GC SHALL NOTIFY THE VA OF ANY DISCREPANCIES OR CONFLICTS BEFORE PROCEEDING WITH
THAT PORTION OF THE WORK.
B. THE CONTRACTORS SHALL COORDINATE EQUIPMENT AND MATERIAL TRAFFIC AND STORAGE WITH COR.
C. ALL UTILITY WORK SHALL BE COORDINATED WITH MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION.
D. ALL ASPECTS OF CONTRACTOR STAGING AND CONSTRUCTION PHASING SHALL BE APPROVED BY COR.
E. REFER AND ADHERE TO THE INFECTION PREVENTION MEASURE REQUIREMENTS IN SPECIFICATION SECTION 01 00 00 GENERAL REQUIREMENTS. TEMPORARY ICRA BARRIER SHALL BE PROVIDED AT ALL PATIENT RELATED AREAS AND COMPLETED PRIOR TO THE
START OF ANY WORK.
F. THE CONTRACTOR TO REFER TO THE VA COR AND ASBESTOS REMEDIATION STUDY FOR ACTIONS CONCERNING THE POSSIBLE PRESENCE OF ASBESTOS. IF ASBESTOS CONTAINING MATERIALS ARE SUSPECTED, STOP WORK IN THE AREA AND CONTACT COR.
G. THE GC IS RESPONSIBLE FOR REMOVING, STORING AND RELOCATING ALL MOVEABLE EQUIPMENT, FURNITURE, SHELVING AND RELATED
ACCESSORIES. COORDINATE W/ COR.
H. PRIOR TO THE START OF ANY WORK. IT IS RECOMMENDED THAT THE CONTRACTOR VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE EXTENT AND NATURE OF WORK TO BE PERFORMED. EXISTING CONDITIONS MAY SLIGHTLY VARY FROM THOSE SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, DIMENSIONS AND MATERIALS IN THE FIELD AND REPORT ANY
DISCREPANCIES TO THE COR.
I. THE CONTRACTOR SHALL VERIFY ALL ITEMS AND OR MATERIALS TO BE SALVAGED BY THE VA PRIOR TO THE START OF DEMOLITION
WORK.
J. ALL DIMENSIONS ARE TAKEN FROM EXISTING FACE OF WALLS.
K. ANY REMOVED SIGNAGE SHALL BE STORED FOR FUTURE USE. COORDINATE WITH COR.
L. ALL HOSPITAL ACCESS POINTS, AND ALL BUILDING EXITS, MUST REMAIN ACCESSIBLE, CLEAR AND UNOBSTRUCTED THROUGHOUT ALL PHASES OF DEMOLITION AND CONSTRUCTION. SHORT-TERM CLOSURE MAY BE ACCEPTABLE AS COORDINATED WITH COR.
M. THE CONTRACTOR SHALL PATCH AND REPAIR ALL FIREPROOFING DAMAGED DURING CONSTRUCTION PRIOR TO PROJECT CLOSEOUT. ALL
WORK SHALL MEET CODE AND SPECIFICATION REQUIREMENTS.
N. ALL COPPER MATERIALS REMOVED FROM THE BUILDING SHALL BE STORED AND TURNED OVER TO VA.
O. ALL EXISTING PENETRATIONS, WITHIN LIMIT OF WORK AND NEW CONSTRUCTION, ARE TO BE SEALED TO MATCH EXISTING CONSTRUCTION
AND RATING. ALL WORK SHALL MEET CODE AND SPECIFICATION REQUIREMENTS.
P. PROTECT ALL EXISTING CONDITIONS & EQUIPMENT DURING CONSTRUCTION.
Q. ALL EXPOSED CONCRETE FLOORS & WALLS SHALL BE SEALED. SEE SPECIFICATIONS.
R. THE CONTRACTOR SHALL COORDINATE ALL ROOF TOP WORK WITH COR. THE EXISTING ROOF WARRANTIES WITH BAKER AND SONS
ROOFING INC. SHALL BE MAINTAINED.
S. THE CONTRACTOR SHALL SCAN (GPR - GROUND PENETRATING RADAR) THE EXISTING CONCRETE SLAB PRIOR TO SAW CUTTING ANY NEW
OPENING.
A
ABV ABOVE
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT
B
B.O. BOTTOM OF
BALC BALCONY
BD BOARD
BET BETWEEN
BLDG BUILDNG
BLKG BLOCKING
BLW BELOW
BM BEAM
BOT BOTTOM
BRKT BRACKET
BULKHD BULKHEAD
BUR BUILT UP ROOF
C
C.G. CORNER GUARD
CAB CABINET
CALK CAULKING
CEM CEMENT
CER CERAMIC
CJ CONTROL JOINT
CLG CEILING
CLOS CLOSET
CLR CLEAR
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
CR CARD READER
CT CERAMIC TILE
CTR CENTER
D
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWN SPOUT
DW DISHWASHER
DWG DRAWING
E
E EAST
EA EACH
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
ELEC ELECTRIC
ELEV ELEVATION
EMER EMERGENCY
ENCL ENCLOSURE
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EW EACH WAY
EXP. JT. EXPANSION JOINT
EXST EXISTING
F
F.O. FACE OF
FA FIRE ALARM
FAP FIRE ANNUNCIATOR
PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
PANEL
FG FINISH GROUP
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FLUOR FLOURESCENT
FT FOOT OR FEET
FUR FURRING
G
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GL GLASS
GND GROUND
GWB GYPSUM BOARD
GYP GYPSUM
H
H.W.H. HOT WATER HEATER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
I
ID INNER DIAMETER
INCAN INCANDESCENT
INSUL INSULATION
INT INTERIOR
J
JAN JANITOR
JST JOIST
JT JOINT
L
LAM LAMINATE
LAV LAVATORY
LB(S) POUNDS
LDG LANDING
LT LIGHT
M
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
O.P. OVERFLOW PIPE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
P
PART PARTITION
PERM PERIMETER
PG PAINT GRADE
PIV PERSONAL IDENTITY
VERIFICATION
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
PT PAINT
PTD PAINTED
R
R RISER
RAD RADIUS
RCP REFLECTED CEILING
PLAN
RD ROOF DRAIN
RE REFER
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
RM ROOM
S
RO ROUGH OPENING
RTU ROOF TOP UNIT (MECH)
S SOUTH
SAFB SOUND ATTENUATION
FIBER BATT
SC SCUPPER
SCHED SCHEDULE
SEAL SEALANT
SECT SECTION
SF SQUARE FOOT
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQURE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUPSPENDED
SYM SYMMMETRICAL
T
T TREAD
T&G TONGUE & GROOVE
TEL TELEPHONE
TER TERRAZZO
THK THICK
THR THRESHOLD
TO TOP OF
TYP TYPICAL
U
UC UNDERCUT
UNFIN UNFINISHED
UNO ULNESS NOTED
OTHERWISE
UON UNLESS OTHERWISE
NOTED
UTIL UTILITY
V
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VENT TERMINATION PIPE
VWC VINYL WALL COVERING
W
W WEST
W/ WITH
W/O WITHOUT
WC WATERCLOSET
WD WOOD
WIN WINDOW
WP WATERPROOF
WS WETSTACK
WSCT WAINSCOT
WT WEIGHT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
GENERAL NOTESSYMBOL LEGEND CONT.SYMBOL LEGENDABBREVIATIONS
C
U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:5
P
M
GI001
SYMBOLS AND ABBREVIATIONS RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
Revisions: Date:
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, ADA RAMP SECTION VIEW
RAIN-LIP SLAB DEPRESSION
TAP-CONS OR APPROPRIATE
FASTENERS FOR EXISTING
MATERIAL
METAL RAMP 1/12"
MAX. SLOPE
ACCESSIBILITY SIGN - MUST BE
VISIBLY PLACED OUTSIDE THE UNIT
DOOR HARDWARE
11B-404.2.7
(A) HINGED DOOR
(B) SLIDING DOOR(C) FOLDING DOOR
GENERAL NOTES:
1. DETAILS INCLUDED ON THIS SHEET ARE NOT PROJECT SPECIFIC. DETAILS ARE
GENERAL AND MAY NOT APPLY TO THIS DRAWING PACKAGE. THESE DETAILS ARE
SUPPLEMENTAL TO WORK INDICATED ON PLAN AND DRAWINGS.
2. PROVIDE BACKING PLATE PER DETAILS. FOR ALL HANDRAIL BRACKETS, GRAB BARS,
BENCHES, AND ALL OTHER WALL MOUNTED ITEMS WHERE DETAILED OR CALLED
FOR.
3. DOORS SHALL PROVIDE A CLEAR WIDTH OF 32" MINIMUM. CLEAR OPENINGS OF
DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF
THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES (11B-404.2.3).
4. HARDWARE: OPERABLE FROM INSIDE WITHOUT USE OF KEY OR SPECIAL
KNOWLEDGE OR EFFORT. OPERABLE BY SINGLE EFFORT LEVER-TYPE DEVICE (NOT
REQUIRING GRASPING). MOUNTED 34" TO 44" ABOVE FINISH FLOOR.
5. THRESHOLDS, IF ANY, SHALL BE 1/2" HIGH MAXIMUM BEVELED. (11B-404.2.5).
6. DOOR HARDWARE CAN BE OPERATED WITH A CLOSED FIST OR A LOOSE GRIP TO
ACCOMMODATE GREAT RANGE OF USERS.
7. DOORS SURFACE WITHIN 10" FROM FINISH FLOOR OR GROUND VERTICALLY
MEASURED SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE
FULL WIDTH OF THE DOOR. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN
THESE SURFACES SHALL BE WITHIN 1/16" OF THE SAME PLANE AS THE OTHER.
CAVITIES CREATED BY ADDED KICK PLATE SHALL BE CAPPED (11B-404.2.10).
8. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED THE FOLLOWING PER
THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE, TITLE 24, 1008.1.3 AND
11B-404.2.9.
A. INTERIOR DOORS - 5 POUNDS
B. EXTERIOR DOORS - 5 POUNDS
C. FIRE DOORS - 15 POUNDS
OPENING WIDTH
32" MIN
M
IN
D
O O
R H
E
IG
H T
F
IN
IS
H
F L O
O R
A B
O V
E
F
IN
IS
H
F L O
O R
A B
O V
E
U P
T O
-1
/2
11B-404.2.2. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH
TWO LEAVES SHALL COMPLY WITH 11B-404.2.3. CLEAR WIDTH AND
11B-404.2.4. MANEUVERING CLEARANCES.
11B-404.2.3. CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR
WIDTH OF 32" (813 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH
SWINGING DOOR SHALL BE MEASURED BETWEEN THE FACE OF THE
DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENING
MORE THAN 24" (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36"
(914 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO REQUIRED
CLEAR OPENING WIDTH LOWER THAN 34" (864 MM) ABOVE THE FINISH
FLOOR OR GROUND. PROJECTIONS INTO CLEAR OPENING WIDTH
BETWEEN 34" (864 MM) AND 80" (2032 MM) ABOVE THE FINISH FLOOR OR
GROUND SHALL NOT EXCEED 4" (102 MM).
32" MIN
32" MIN
32" MIN
PUSH SIDE
PULL SIDE
DOOR
18" MIN AT INTERIOR
DOOR
24" MIN AT EXTERIOR
A CLOSER & LATCH
12" MIN IF DOOR HAS BOTH
FOF
FOF
30"x48" CLR
M
IN
M
IN
56" MIN WALL-MOUNTED
59" MIN FLOOR-MOUNTED
48" MIN
FINISH
FLOOR EVEN
COMPRESSED
CARPET 1/4" MAX
BELOW THRESHOLD
/4
/4
/4
M A
X
/4
M A
X
WALKING PERPENDICULAR TO WALL
OVERHEAD OBSTRUCTION
CANE RANGE
LOBBY
ANY AMOUNT
M
IN
O R
B E
L O
W
W H
E N
M
IN
4" MAX
W H
E N
O R
B E
L O
W
SUB-SURFACE IMAGE
CENTERED ON SIGN
WOMEN'S MEN'S
1/4" THICK, 12" ∅ CIRCLE 1/4" THICK
12" EQUILATERAL TRIANGLE
BACKGROUND COLOR
SHALL CONTRAST W/
DOOR COLOR
SUB-SURFACE IMAGE
CENTERED ON SIGN
BACKGROUND COLOR
SHALL CONTRAST W/
DOOR COLOR
NOTES:
1. SYMBOLS ARE TO BE
CENTERED ON THE DOOR
AND ARE TO BE DISTINCTLY
DIFFERENT FROM THE
DOOR IN COLOR AND IN 70%
MIN CONTRAST.
2. ATTACH SIGNS USING
ADHESIVE AND THREE (3)
FLATHEAD CHROME,
TAMPER-RESISTANT WOOD
SCREWS, COUNTERSUNK.UNISEX
1/4" THICK, EQUILATERAL
TRIANGLE ON 1/4" THICK,
12" ∅ CIRCLE
T
O F
F
T O
F F
NOTES:
1. PROVIDE ACCESSIBLE ENTRY SIGNAGE AT ALL EXTERIOR ENTRY DOORS
2. PROVIDE ACCESSIBLE ROOM SIGNAGE AT ALL ACCESSIBLE ROOMS.
3. BRAILLE SHALL BE FLUSH LEFT OR CENTERED - PER APPLICABLE CODES
ROOM 101
INTERNATIONAL SYMBOL
OF ACCESSIBILITY, WHITE
SEE CBC FIG. 11B-703.7.2.3
BLUE BACKGROUND
PICTOGRAM ADJACENT
TO ROOM SIGN AT
MAIN ENTRY DOORS ONLY
ROOM NAME
AND NUMBER
+/- 5" - 9" +/- 13" - 10"
L E
T T
E R
IN
G
/8
H E
IG
H
T O
F1 3/4"1 3/4" EQ EQ
BRAILLE
CHARACTERS
/2
M
IN
M
IN
B
O T
O F
B R
A
IL
L E
M
IN
B
O T
O F
T O
P T
E X
T L
IN
E
CARD READER ON
FREE STANDING PEDESTAL
WHEN D = 10" OR LESS, H = 54"MAX
WHEN D = 11", H = 53.5" MAX
WHEN D = 11", H = 53.0" MAX
WHEN D = 11", H = 52.5" MAX
WHEN D = 11", H = 51.5" MAX
WHEN D = 11", H = 51.0" MAX
WHEN D = 11", H = 50.5" MAX
WHEN D = 11", H = 50.0" MAX
WHEN D = 11", H = 49.5" MAX
WHEN D = 11", H = 49.0" MAX
WHEN D = 11", H = 48.5" MAX
WHEN D = 11", H = 47.5" MAX
WHEN D = 11", H = 47.0" MAX
WHEN D = 11", H = 46.5" MAX
WHEN D = 11", H = 46.0" MAX
CORRESPONDING REACH
HEIGHTS FOR GIVEN DEPTHS
HIGH AND LOW
SIDE REACH LIMITS
MAXIMUM SIDE REACH
OVER OBSTRUCTION
HIGH FORWARD
REACH LIMIT
(D) ARM REACH RANGE LIMITS
SIDE ELEVATIONFRONT ELEVATION
X SHALL BE LESS THAN OR EQUAL
TO 25 INCHES. Z SHALL BE
GREATER THAN OR EQUAL TO X.
WHEN X IS LESS THAN 20 INCHES,
THEN Y SHALL BE 48 INCHES MAX
WHEN X IS 20 TO 25 INCHES, THEN Y
SHALL BE 44 INCHES MAXIMUM.
1. PROVIDE MOUNTING OF
ACCESSIBLE CONTROLS AND
OPERATING MECHANISMS PER CBC
1117B.6
2. INSTALL ACCESSIBLE ELECTRICAL
SWITCHES AND RECEPTACLE
OUTLETS PER CBC 1117B.6 ITEM 5
M A
X
LEVEL
ACCESSIBLE
AREA
LOCATED ON FREE-
STANDING PEDESTALS
REACH
DEPTH
10" MAX
M A
X
M A
X
30" MIN
MAX
10"
M
IN
"4
M A
X
MAX
10" 30" MIN
M A
X
M
IN
48" MIN
48" MIN
Y
Z
X
MAXIMUM FORWARD REACH
OVER AN OBSTRUCTION
M
IN
M A
X
ACCESSIBLE CONTROLS
AND OPERATING SYSTEMS
X
Z
M
IN
FRONT APPROACH
SIDE APPROACH
M
IN
10" MAX
M A
XR
E
A C
H H
E
IG
H T
H
M A
X
D
REACH
24" MAX
M A
X
M A
X
30" MIN
MAX
>10"- 24"
(D) CLEAR FLOOR SPACEMANEUVERING CLEARANCE FOR ALCOVES
(C) SPACE REQUIRED FOR WHEELCHAIR SEATING
PERPENDICULAR APPROACHPARALLEL APPROACH
NOTE : IF X > 24 INCHES, THEN
AN ADDITIONAL MANEUVERING
CLEARANCE OF 6 INCHES SHALL
BE PROVIDED AS SHOWN.
NOTE : IF X > 15 INCHES, THAN
AN ADDITIONAL MANEUVERING
CLEARANCE OF 12 INCHES
SHALL BE PROVIDED AS SHOWN.
REAR ACCESS
FRONT ACCESS
S
ID
E A
C C
E S
S A
IS
L E
M
IN
33" MIN
M
IN
33" MIN
30" 6"
X
M O
R E
O
R
X
48" 12"
48" MIN
M
IN
10"
30" MIN
M
IN
48" MIN
M
IN
36" MIN 60" MIN
33" MIN 33" MIN
TWO SPACES
36" MIN
SINGLE SPACE
M
IN
FRONT ACCESS
REAR ACCESS
D O
O R
F R
A M
E W
H E
N D
IM
A
B V
D O
O R
H E
A D
I S
ALIGN TOP OF
PLATE OR DEVICE
HIGHEST OPERABLE PARTS OF:
SWITCHES, CONTROLS
THERMOSTATS, INTERCOM &
FIRE ALARM MANUAL STATION
(B) BULLETIN
BOARD
(A) COAT
HOOK
(C) EMERGENCY
SIGNAGE
(D) BROCHURE
HOLDER
(F) AUDIBLE AND
VISUAL FIRE
ALARM
(E) CLOCK OR
CLOCK
OUTLET
(G) FIRE
EXTINGUISHER
CABINET
(J) AUTO DOOR
OPENER
(H) CARD
READER
(K) OPERATING
SYSTEMS/SWITCHES
EMERGENCY SIGN,
LIVE LOAD SIGN OR
OCCUPANT LOAD SIGN
(S)
COAT HOOK
DOOR MOUNT
(R)
ELECTRICAL
PANEL BOARD
(U)
EXIT SIGNAGE
WALL MOUNT
S
ID
E W
H E
N D
IM
A
B V
D O
O R
H E
A D
EXIT
EXIT
(A) MIRROR (B) RECESSED
WASTER
DISPENSER
(C) TOILET
SEAT COVER
DISPENSER
(D) SOAP
DISPENSER
(E) TOILET
PAPER
DISPENSER
(F) GRAB BARS & WATER
CLOSET
(G) URINAL
FF
NOTES: 1. FLUSH
VALVE TO BE LOCATED
TO THE WIDE SIDE OF
COMPARTMENT
M A
X
M
IN
M
IN
M A
X
6" MAX
25" MAX
8" MIN
11" MIN
M
IN
DASHED LINE
INDICATES CLEAR
SPACE
M A
X
M A
X
12" MAX 42" MIN
54" MIN
24" MIN
T O
O U
T L E
T
M
IN
7" - 9" 36" MAX
17" - 18"
6" MAX 36" MIN
12" MIN
24" MIN
M
IN
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
FF
F R
O N
T R
E A
C H
S
ID
E R
E A
C H
H A
N D
L E
T
.O
M
A X
M
IN
FF
A T
H A
N D
L E
EQ EQ
A L
IG
N
W
IT
H T
O P
O F
A D
J F
R A
M E
O N
S T
R
IK
E
L O
C A
T E
A B
V
HEIGHT OF
LETTERING TO BE 5/8"
MIN TO 2" MAX
LETTERS RAISED 1/32"
NOTES:
1. LETTERS, BRAILLE CHARACTERS & PICTOGRAM SYMBOL
TO BE RAISED .025" to .037" ABOVE THEIR BACKGROUND.
2. UPPER CASE CHARACTERS TO BE SANS SERIF, 5/8" MIN
TO 2" MAX HEIGHT.
3. WIDTH OF UPPER CASE "O" IS 60% MIN AND 110% MAX
OF THE HEIGHT OF THE UPPERCASE "I".
4. STROKE WIDTH TO HEIGHT RATIO TO BE BETWEEN 15%
OF CHARACTER HEIGHT.
5. CHARACTERS & SYMBOLS SHALL CONTRAST WITH
6. PICTOGRAM ACCOMPANIED BY EQUIVALENT VERBAL
DESCRIPTION DIRECTLY BELOW.
7. PICTOGRAM IDENTIFICATION SIGN TO MATCH DOOR
SIGN.
8. SIGN TO BE A MINIMUM OF 6" x 6".
9. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE
LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" X 18",
CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED
BEYOND THE ARC OF ANY DOOR SWING.
10. BRAILLE CHARACTERS TO BE CONTRACTED GRADE II,
3/8" TO 1/2" MAXIMUM BELOW TACTILE.
11. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED
48" MINIMUM ABOVE THE FINISH FLOOR GROUND
SURFACE, MEASURED FROM THE BASELINE OF THE
LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM
ABOVE THE FINISH FLOOR OR GROUND SURFACE
MEASURED FROM THE BASELINE OF THE HIGHEST LINE
OF RAISED CHARACTERS.
DOOR SIGN
PER DETAIL:
MAX
24"
SPACE
CLEAR FLOOR
4" - 12"
EQ EQ EQ EQ
A
F F
DOOR SIGN
PER DETAIL:
FF
EQUIPMENT, PANEL
BOARD, CABINET OR
SIMILAR FEATURECORNER
GUARD
TYP
CHAIR RAIL
UON
OUTLET OR
SIMILAR
OPEN
CEILING PER
PLAN
CORNER GUARD AT
END WALL
OPEN
BARN DOORS FULLY
OPEN. MAINTAIN
GUARD RAIL GAP
FROM DOOR OF 1" TYP
U O
N
PROVIDE RESILIENT CORNER GUARDS AT
CORRIDORS AND ADMINISTRATIVE AREAS.
PROVIDE STAINLESS STEEL CORNER
GUARDS IN ALL CLINICAL AREAS
1" TYP
H A
N D
R A
IL
T
O
C H
A
IR
R A
IL
T
O
1" TYP
FF
M A
X
BABY
CHANGING
STATION
M
IN
INSULATE ENTIRE
HOT WATER AND
DRAIN PIPE
1/2" = 1'-0"
DOOR REQUIREMENTS
1/2" = 1'-0"
DOOR CLEARANCE
1/2" = 1'-0"
ACCESSIBLE RESTROOM
6" = 1'-0"
ALLOWABLE THRESHOLD
1/4" = 1'-0"
PROTRUDING OBJECTS
1 1/2" = 1'-0"
RESTROOM SIGNAGE
3" = 1'-0"
DOOR SIGNAGE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
C U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:5
P
M
GI002
ACCESSIBILITY DETAILS RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"
SPACE AND REACH RANGE
1/4" = 1'-0"
WHEELCHAIR CLEARANCE
1/4" = 1'-0"
STANDARD MOUNTING HEIGHTS
Revisions: Date:
ADMIN. REVIEW 12/07/2019
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, "Q
R O
A D
LAUREATE BLVD.
E
E
107326.A01
+0
+0
+0
+0
+8 5.
10+
11+
12+
13+00
14+00
15+00
16+
+0
+0
+0
+0
+0
40+ 32.12
31+
32+00
33+00
34+00
35+00
36+
37+
38+00
39+00
40+
10+
11+
12+
+0
27+ 38.
+0
+0
23+
24+
25+
26+
27+
11+00
12+00
PC
: 12+
21.00
PCC: 13+19.16
PCC: 14+79.56
PT
+6 4.
PC
+1 7.
P T:
.9
P C 2+ 2.
PRC
: 23
+56 .66
P T:
.9
P C 6+ 7.
PC
C : 31+
06.96
PT:
+1 4 .2
PC:
+1 5.9
PT: 39+
68.86
L1
L2
L3
L4
L5
L6
L7
PC
12+
63.17
PCC: 16+09.14 PT
+5 8.
PC: 18+70.73
PRC: 20+72.27
PT:
+13 .23
L8
L9
L1
PI : 10+50.00
L1
L1
C7
C
C1
C
C
C4
C
C
C
C10
C11
C12
C13
TC
4.
.2
RO
PE
C
OU
RS
E RO
PE
C
OU
RS
E
25'
UTIL
ITIES
, TR
AIL,
AND
LA
NDS
CAP
E E
ASE
MEN
T
25' UTILITIES, TRAIL,
AND LANDSCAPE EASEMENT
U
TI
LI
TI
E S
AN
D
LA
N D S C
AP
E
EA
S E M E N T
PEDESTRIAN
TR
AIL
EASEM
EN
T
25' PEDESTRIAN
TRAIL EASEMENT
LAU
REA
TE
BLV
D.
A8
NAVE
SECR ETAR Y
BL ES SED
SACR AMEN T
CH
AP EL
SAC RIS
T Y
TOI LE T
TOI LET
CO M M
EL E C
COR RI DO R
CH APLA I N
DR INK IN
G
FOU NT A I N
N O
P A R K
IN
G
N O
P A R K
IN
G
N O
P A R K
IN
G
N O
P A R K
IN
G
MERGE
ONLY
ONLY
ONLY
ONLY ONLY
ONLY
ONLY
ONLY
ONLY
3.
A1
1 AS0
1a
S
TA
IR
S
TA
IR
ADMIN
IST RA TIO
N
P A
TIE
N T
A C
T
IV
IT
Y A
R E A
O U T D O
O R R
E
CR
E
ATIO
N A
R
EA
M
AIN
E N
TRA
N C E
M E C
H
AN
IC
A L
S P
AC
E
L O
AD
IN
G
D O
C
K AIR
IN
TAKE
SHAFT
F
IR
E
P R O
TE
C
TIO
N
R
IS
E R
1B20
M ec han ic al
1B40
H
AC
1A70
O ff ic e
1A70
O ff ic e
1A70
O ff ic e
1A70
O ff ic e
1A71
O ff ic e
1A71
O ff ic e
1A71
O ff ic e
1A71
O ff ic e
1A80
St af f
T l t
1B30
R es id en t
T l t
1A80
O ff ic e
1A80
O ff ic e
1A80
O ff ic e
1A71
O ff ic e
1AC
b
L ou ng e
1A60
O ff ic e
1A60
O ff ic e
1A60
O ff ic e
1A70
O ff ic e
1A60
O ff ic e
1A60
O ff ic e
1A60
V olu nte e r s
1A40
Pa tie nt
S to r
1A10
C on fe re nc e
1A20
Pu bl ic
T l t
1A50
St af f
T l t
1AC
a
R ec e pt io n
1A40
Q uie t
R oo m
1A C
V est ib u le
1B10
Fi tn es s
R oo m
1A10
R ec r e at io n/ M u lti
P ur po se
1B
3a
Kitc h en et te
1B10
M ul ti
P ur po se
R oo m
1B10
K itc he n
1B10
In si de
D in in g
Ar ea
1B50
M ed s
1B50
Exa m
Tre atm en t
1B20
G en era l
S to r
1B30
N ur se
1B C
W ai tin g
1B20
Soile d
Li nen
C ol le ct io n
1B20
N on
-F ood
S to r
1B20
Bu lk
F oo d
C ar ts
B1
02c
H
AC
1A40
C om m
1A40
Ele c
O utd oo r D in in g Are a
1A10
C ra ft
1B20 3A
E le ct ric a l
1A50
St af f
L ou ng e
1B40
ST
G
D
D
T ectonic Cop yright 2007
T ectonic Cop yright 2007
DN
BUIL
DIN
G
CLIN
IC
BUIL
DIN
G
HO
SPIT
AL
BUIL
DIN
G
PARKIN
G
E
AST
BUIL
DIN
G
PARKIN
G
W
EST
BUIL
DIN
G
W
AREHO
USE
BUILDING 04
CENTRAL
ENERGY PLANT
BUILDING 06
GATE HOUSE
MAIN ENTRY
BUILDING 08
GATE HOUSE
SERVICE ENTRY
BUIL
DIN
G
DO
M
IC
IL
LIA
RY
BUILDING 10
CHAPEL
BUILDING 11
COMMUNITY
LIVING CENTER
1. NO SITE WORK IS BEING PERFORMED. THIS SHEET IS FOR REFERENCE ONLY.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
KEY PLAN - 1ST FLOOR
LEGEND
GENERAL NOTES
NOT TO SCALE
MAIN HOSPITAL
BUILDING 1
PARKING -
EAST
PARKING -
WEST
PHARMACY
DOMICILIARY
BUILDING 9
MAIN ENTRY
COMPUTER TOMOGRAPHY
TOOL CRIB
WAREHOUSE - BUILDING 5
SHOPS
PATIENT STORAGE
C U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:0
P
M
GI003
EXISTING SITE PLAN RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
1" = 100'-0"1
EXISTING SITE PLAN
Revisions: Date:
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, UP
DN
UP
UP
DN
DN
UP
UP UP
UPUP
UP
UP
UP
DN
UP
DN DN
UP
UP
UP
UP
UPUP
1AS01a
STAIR
STAIR
ADMINISTRATION
PATIENT ACTIVITY AREA
OUTDOOR RECREATION AREA
MAIN ENTRANCE
MECHANICAL
SPACE
LOADING DOCK
AIR INTAKESHAFT
FIRE
PROTECTION
RISER
1B203
Mechanical
1B404
HAC
1A702
Office 1A704
Office 1A706
Office 1A708
Office 1A710
Office 1A712
Office 1A714
Office 1A716
Office
1A803 Staff
Tlt
1B302
Resident
Tlt
1A805
Office
1A804
Office
1A802
Office
1A711
Office
1AC01b
Lounge
1A601
Office
1A605
Office
1A606
Office
1A701
Office
1A603
Office
1A602
Office
1A604
Volunteers
1A401
Patient
Stor
1A101
Conference
1A201
Public
Tlt
1A502 Staff
Tlt
1AC02a
Reception
1A402
Quiet
Room
1AC03
Vestibule
1B101
Fitness
Room
1A105
Recreation/Multi
Purpose
1B103a
Kitchenette
1B103 Multi
Purpose
Room
1B102
Kitchen
1B105
Inside
Dining Area
1B502
Meds
1B501
Exam/
Treatment
1B206
General
Stor
1B301
Nurse
1BC03
Waiting
1B208
Soiled
Linen
Collection
1B202
Non-Food
Stor
1B204 Bulk
Food
Carts 1B102c
HAC
1A405 Comm
1A403 Elec
Outdoor Dining Area
1A103 Craft
1B203A
Electrical
1A501 Staff
Lounge
1B402
STG
D1
D2
AREA OF WORK
NOT IN SCOPE OF WORK
1. REFER TO SHEET GI001 FOR DEMOLITION GENERAL NOTES.
2. REFER TO SHEET GI001 FOR GENERAL NOTES.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
KEY PLAN - 1ST FLOOR
LEGEND
GENERAL NOTES
NOT TO SCALE
MAIN HOSPITAL
BUILDING 1
PARKING -
EAST
PARKING -
WEST
PHARMACY
DOMICILIARY
BUILDING 9
MAIN ENTRY
COMPUTER TOMOGRAPHY
TOOL CRIB
WAREHOUSE - BUILDING 5
SHOPS
PATIENT STORAGE
C U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:1
P
M
GI004
OVERALL PLAN - BUILDING 1 &
BUILDING 9 - 1ST FLOOR
RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
N
0 20' 40' 80'
1" = 40'-0"1
OVERALL PLAN - BUILDING 1 - 1ST
FLOOR
1" = 40'-0"2
OVERALL PLAN - BUILDING 9 - 1ST
FLOOR
Revisions: Date:
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, DN
DN
DN
DN
UP
DN
UP
DN
DN DN
UPDNUP
UP
UP UP UP
UP
UP
DN
UP
UP
AREA OF WORK
NOT IN SCOPE OF WORK
1. REFER TO SHEET GI001 FOR DEMOLITION GENERAL NOTES.
2. REFER TO SHEET GI001 FOR GENERAL NOTES.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
LEGEND
GENERAL NOTES
NOT TO SCALE
MAIN HOSPITAL
BUILDING 1
PARKING -
EAST
PARKING -
WEST
KEY PLAN - 4TH FLOOR
OFFICE OF INFORMATION AND TECHNOLOGY (OIT)
MEDICAL MEDIA
C U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:3
P
M
GI005
OVERALL PLAN - BUILDING 1 - 4TH
FLOOR
RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
N
0 20' 40' 80'
1" = 40'-0"1
OVERALL PLAN - BUILDING 1 - 4TH
FLOOR
Revisions: Date:
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, UPUPUPUP
J J
K K
K.7 K.7
K.6 K.6K.7K.6K.7K.6
REMOVE (E)
MOP SINK
REMOVE (E) FULL-
HEIGHT WALL.
REMOVE (E) FINISHES
THROUGHOUT.
REMOVE (E) FINISHES
7' - 2"
47 SF
HAC
1U501c
61 SF
HAC
1U302
REMOVE (E) WALLS
AND DOORS AND
DOOR FRAMES
REMOVE (E) ROLL-UP
GRILLE GATE
ASSEMBLY, TYP. OF (2)
REMOVE (E) GLAZING
ASSEMBLY AT
TRANSACTION COUNTER,
TYP. OF (4)
PHARMACY
1U501
PICK-UP
WINDOW
1U502
COMM
1U301
ELEC
1U303
PASSAGE
1UC03
SODA CLOSET
1V102
STAIR -
PHARMACY
1US01
O.P. SECURE
PRESCRIPTION
STORAGE
1U501b
DEMO (E) STUD WALLS
AND COUNTERTOPS,
TYP OF (6)
REMOVE (E)
WIRE SHELVING
REMOVE (E) SHELVING
AND SALVAGE FOR
OWNER USE
8' - 2"
1' - 9"
/8
CONSULT
1U501a
REMOVE (E) FLOORING
AND FINISHES AND
PREP FOR (N)
REMOVE (E) FLOORING
AND FINISHES AND
PREP FOR (N)
J J
K K
REMOVE (E) 2X2 ACT AND
GRID ASSEMBY
REMOVE (E) LIGHTING,
MECHANICAL, AND
EXHAUST FIXTURES, TYP.
PHARMACY
1U501
PICK-UP
WINDOW
1U502
COMM
1U301
ELEC
1U303
PASSAGE
1UC03
SODA CLOSET
1V102
STAIR -
PHARMACY
1US01
O.P. SECURE
PRESCRIPTION
STORAGE
1U501b
HAC
1U501c
HAC
1U302
REMOVE (E) EXHAUST
GRILLES, SEE MECHANICAL
J J
K K
K.7 K.7
K.6 K.6K.7K.6K.7K.6 ø 5' - 0"
61 SF
HAC
1U302
STAFF
RESTROOM
1U501c
INSTALL (N) FINISHES AND
FIXTURES THROUGHOUT.
INSTALL (N) 2-HR SMOKE FIRE RATED
WALL PARTITION TO MATCH EXISTING
WITH WATER RESISTANT GYP BD AND
CERAMIC TILE ON ONE SIDE. PATCH AND
REPAIR FINISHES TO MATCH EXISTING.
INSTALL (N) CLASS V
BALLISTIC WINDOW
ASSEMBLY WITH PASS-THRU
AND SPEAKER, TYP. OF (6)
INSTALL (N) TYPE X GYP BOARD
OVER 9-GAUGE EXPANDED
METAL SPOT WELDED EVERY
(6) INCHES TO EACH SIDE OF (E)
FRAMING FROM TOP OF ACT
CEILING TO BOTTOM OF
STRUCTURE, AT FULL LENGTH
OF PHARMACY, TYP
AE2011
ADA
STATION
ADA
STATION
PHARMACY
1U501
PICK-UP
WINDOW
1U502
COMM
1U301 ELEC
1U303
PASSAGE
1UC03
SODA CLOSET
1V102
STAIR -
PHARMACY
1US01
BREAK ROOM
1U501b
INSTALL (N) FLOOR DRAIN AND
SLOPE TILE FLOOR 2% MAX
/4 "1
A
B TYP
E
E
E
E
E
E
INSTALL (N) CMU WALL TO
STRUCTURE WITH GYP BOARD
BOTH SIDES, TYP. OF (6)
AE201
1U501b
1U501c
INSTALL (N) DOOR AND DOOR FRAME
INSTALL (N) PIV
CARD READER ON
PUSH SIDE OF DOOR
CONSULT
1U501a1
1' - 7"
16' - 2"
5' - 5" 12' - 4"
2' - 2" 21' - 0"
AE20116
1U501a.2
INSTALL (N) DOOR AND DOOR FRAME
AND INFILL OPENING TO MATCH
EXISTING, SEE DETAIL /4 AE501
J J
K K
INSTALL (N) HARD LID
CEILING ASSEMBLY, TYP.
INSTALL (N) LIGHTING,
MECHANICAL, AND
EXHAUST FIXTURES, TYP.
12' - 9"
2' - 11 1/4"
PHARMACY
1U501
PICK-UP
WINDOW
1U502
COMM
1U301
ELEC
1U303
PASSAGE
1UC03
SODA CLOSET
1V102
STAIR -
PHARMACY
1US01
BREAK ROOM
1U501b
STAFF
RESTROOM
1U501c
HAC
1U302INSTALL (N) 2x2
ACT AND GRID
ASSEMBLY, TYP
INSTALL (N) EXHAUST
DIFFUSERS, SEE
MECHANICAL, TYP
INSTALL (N) CEILING
MOUNTED CAMERA
1. REFER TO MECHANICAL, PLUMBING, ELECRICAL, AND STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
2. REFER TO SHEET GI001 FOR DEMOLITION GENERAL NOTES.
3. REFER TO SHEET GI001 FOR GENERAL NOTES.
4. REFER TO SHEET AE601 FOR FINISH, DOOR, AND WINDOW SCHEDULES, NOTES, AND DETAILS.
5. REFER TO SHEET GI002 FOR ACCESSIBILITY DETAILS AND MOUNTING HEIGHTS.
6. REFER TO SHEET AE501 FOR WALL TYPES.
7. REFER TO SHEETS AE503 - AE507 FOR CEILING DETAILS.
8. DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.
9. LOCATE NEW DOORS FRAMES SO HINGED SIDE IS 3" INCHES FROM EDGE OF FRAME TO FACE OF
PERPENDICULAR STUD, UNLESS OTHERWISE NOTED.
10. CONTRACTOR TO REVIEW INTERIOR ELEVATIONS, AND CONFIRM WALL ASSEMBLY APPROPRIATE FOR
FINISHES AT WET AREAS, KITCHEN, RESTROOMS, AND JANITOR CLOSETS.
11. CONTRACTOR TO REVIEW ELEVATIONS FOR WINDOW VARIATIONS ON WINDOW SCHEDULE.
12. PROVIDE BACKING FOR ALL CASEWORK.
13. CASEWORK FINISHES TO BE HPDL-6 AND COUNTERTOP FINISHES TO BE SSM-7.
EXISTING WALL TO REMAIN
PARTIAL HEIGHT WALL
NON RATED PARTITION
1 HOUR FIRE RATED WALL
2 HOUR FIRE RATED WALL
SMOKE WALL
CMU WALL
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
KEY PLAN - 1ST FLOOR
LEGEND
GENERAL NOTES
NOT TO SCALE
MAIN HOSPITAL
BUILDING 1
PARKING -
EAST
PARKING -
WEST
PHARMACY
DOMICILIARY
BUILDING 9
MAIN ENTRY
COMPUTER TOMOGRAPHY
TOOL CRIB
WAREHOUSE - BUILDING 5
SHOPS
PATIENT STORAGE
C U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:5
P
M
AE101
1ST FLOOR PLANS - PHARMACY RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
N
0 4' 8' 16'
1/8" = 1'-0"1
1ST FLOOR PLAN - PHARMACY
DEMOLITION
1/8" = 1'-0"2
1ST FLOOR RCP - PHARMACY
DEMOLITION
1/8" = 1'-0"3
1ST FLOOR PLAN - PHARMACY
PROPOSED
1/8" = 1'-0"4
1ST FLOOR RCP - PHARMACY
PROPOSED
Revisions: Date:
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, C
C
663 SF
C.T. (ED)
1E702
82 SF
CONTROL RM
1E602
REMOVE (E)
COUNTER AND
SUPPORTS
REMOVE (E) WALL.
PREP FOR (N) DOOR
AND FRAME ASSEMBLY
REMOVE (E) WALL.
PREP FOR (N) DOOR
AND FRAME ASSEMBLY
2' - 8"
REMOVE (E)
CASEWORK AND
COUNTERTOP
REMOVE (E) WALL
PROTECTION
CC
82 SF
CONTROL RM
1E602
663 SF
C.T. (ED)
1E702
DEMOLISH (E)
GYP BD SOFFIT
C
C
82 SF
CONTROL RM
1E602
663 SF
C.T. (ED)
1E702
INSTALL (N) SOLID
SURFACE COUNTER
AND SUPPORTS
INSTALL (N) 36X84 DOOR
AND FRAME ASSEMBLY
INSTALL (N) 72X84
DOOR AND FRAME
ASSEMBLY
4K802g
4K802f
ID OUTLETS/DATA/ETC
TO BE RELOCATED
AE201
AE2012
INSTALL (N) PLAM CASEWORK AND
SOLID SURFACE COUNTERTOP
INSTALL (N) PIV CARD READER
AUTOMATIC OPENER ON PUSH
SIDE OF DOOR
C
C
82 SF
CONTROL RM
1E602
663 SF
C.T. (ED)
1E702
INSTALL (N)
GYP BD SOFFIT
1. REFER TO MECHANICAL, PLUMBING, ELECRICAL, AND STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
2. REFER TO SHEET GI001 FOR DEMOLITION GENERAL NOTES.
3. REFER TO SHEET GI001 FOR GENERAL NOTES.
4. REFER TO SHEET AE601 FOR FINISH, DOOR, AND WINDOW SCHEDULES, NOTES, AND DETAILS.
5. REFER TO SHEET GI002 FOR ACCESSIBILITY DETAILS AND MOUNTING HEIGHTS.
6. REFER TO SHEET AE501 FOR WALL TYPES.
7. REFER TO SHEETS AE503 - AE507 FOR CEILING DETAILS.
8. DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.
9. LOCATE NEW DOORS FRAMES SO HINGED SIDE IS 3" INCHES FROM EDGE OF FRAME TO FACE OF
PERPENDICULAR STUD, UNLESS OTHERWISE NOTED.
10. CONTRACTOR TO REVIEW INTERIOR ELEVATIONS, AND CONFIRM WALL ASSEMBLY APPROPRIATE FOR
FINISHES AT WET AREAS, KITCHEN, RESTROOMS, AND JANITOR CLOSETS.
11. CONTRACTOR TO REVIEW ELEVATIONS FOR WINDOW VARIATIONS ON WINDOW SCHEDULE.
12. PROVIDE BACKING FOR ALL CASEWORK.
13. CASEWORK FINISHES TO BE HPDL-6 AND COUNTERTOP FINISHES TO BE SSM-7.
EXISTING WALL TO REMAIN
PARTIAL HEIGHT WALL
NON RATED PARTITION
1 HOUR FIRE RATED WALL
2 HOUR FIRE RATED WALL
SMOKE WALL
CMU WALL
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
KEY PLAN - 1ST FLOOR
LEGEND
GENERAL NOTES
NOT TO SCALE
MAIN HOSPITAL
BUILDING 1
PARKING -
EAST
PARKING -
WEST
PHARMACY
DOMICILIARY
BUILDING 9
MAIN ENTRY
COMPUTER TOMOGRAPHY
TOOL CRIB
WAREHOUSE - BUILDING 5
SHOPS
PATIENT STORAGE
C U s e rs \h h o rt o n
\D o c u m e n ts
\A R
C H
-V
A L N
V
S H h o rt o n
H S
M .r v t
/2 /2
:1
:5
P
M
AE102
1ST FLOOR PLANS - COMPUTER
TOMOGRAPHY
RENOVATE VARIOUS SPACES AT
LAKE NONA
13800 Veterans Way, Orlando FL 32827
675-23-105
STANDARD APPROVING TEAM
09/28/2023 MR HH
100% CONSTRUCTION
DOCUMENTS
N
0 4' 8' 16'
1/8" = 1'-0"1
1ST FLOOR PLAN - COMPUTER
TOMOGRAPHY DEMOLITION
1/8" = 1'-0"2
1ST FLOOR RCP - COMPUTER
TOMOGRAPHY DEMOLITION
1/8" = 1'-0"3
1ST FLOOR PLAN - COMPUTER
TOMOGRAPHY PROPOSED
1/8" = 1'-0"4
1ST FLOOR RCP - COMPUTER
TOMOGRAPHY PROPOSED
Revisions: Date:
design
AESUS
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 454-2861
Architecture, Engineering, D18
D18
DH
DHDH
D18
DH
AV EQUIPMENT
CHECK-OUT
4G208
REMOVE (E) BASE AND
FLOORING THROUGHOUT.
D18
D18
DH
DHDH
D18
DH
76 SF
AV EQUIPMENT
CHECK-OUT
4G208
REMOVE (E) 2X2
ACT AND GRID
ASSEMBY
REMOVE (E)
LIGHTING AND
MECHANICAL
FIXTURES, TYP.
REMOVE (E)
SUPPLY/RETURN
DIFFUSERS, SEE
MECHANICAL, TYP.
D18
D18
DH
DHDH
D18
DH
MEDICAL
MEDIAL
4G208
216 SF
MEDICAL MCS
' - 1
/8
21' - 6 1/8"
INSTALL (N) FULL-HEIGHT
WALL.
INSTALL (N) FLOOR
AND BASE AS
SCHEDULED, TYP.
INSTALL (N) 84x144 (4) PANEL
SLIDING GLASS DOOR AND
FRAME ASSEMBLY
5' - 6"
16' - 0 1/8"
G056
162"
24"
(E) ELECTRICAL
RACK TO REMAIN
C
D18
D18
DH
DHDH
D18
DH
MEDICAL MCS
MEDICAL
MEDIAL
4G208
CEILING OPEN
TO STRUCTURE
INSTALL (N) LIGHTING,
MECHANICAL, AND
FIXTURES, TYP.
INSTALL (N) 2x2 ACT
AND GRID ASSEMBLY
INSTALL (N)
SUPPLY/RETURN
DIFFUSERS, SEE
MECHANICAL, TYP.
1. REFER TO MECHANICAL, PLUMBING, ELECRICAL, AND STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
2. REFER TO SHEET GI001 FOR DEMOLITION GENERAL NOTES.
3. REFER TO SHEET GI001 FOR GENERAL NOTES.
4. REFER TO SHEET AE601 FOR FINISH, DOOR, AND WINDOW SCHEDULES, NOTES, AND DETAILS.
5. REFER TO SHEET GI002 FOR ACCESSIBILITY DETAILS AND MOUNTING HEIGHTS.
6. REFER TO SHEET AE501 FOR WALL TYPES.
7. REFER TO SHEETS AE503 - AE507 FOR CEILING DETAILS.
8. DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.
9. LOCATE NEW DOORS FRAMES SO HINGED SIDE IS 3" INCHES FROM EDGE OF FRAME TO FACE OF
PERPENDICULAR STUD, UNLESS OTHERWISE NOTED.
10. CONTRACTOR TO REVIEW INTERIOR ELEVATIONS, AND CONFIRM WALL ASSEMBLY APPROPRIATE FOR
FINISHES AT WET AREAS, KITCHEN, RESTROOMS, AND JANITOR CLOSETS.
11. CONTRACTOR TO REVIEW ELEVATIONS FOR WINDOW VARIATIONS ON WINDOW SCHEDULE.
12. PROVIDE BACKING FOR ALL CASEWORK.
13. CASEWORK FINISHES TO BE HPDL-6 AND COUNTERTOP FINISHES TO BE SSM-7.
EXISTING WALL TO REMAIN
PARTIAL HEIGHT WALL
NON RATED PARTITION
1 HOUR FIRE RATED WALL
2 HOUR FIRE RATED WALL
SMOKE WALL
CMU WALL
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
7…