Attachment 1 Technical Specification Sheet .pdf
PDF 761 KB Posted
- Attached to
- Vacuum Relief Furnace
- Solicitation number
- FA9101VRF
About this file
This is a Technical Specifications Sheet for a Horizontal Front-Loading, Internal Gas Quench Vacuum Furnace that must be brand-new and compliant with SAE Aerospace Material Specification (AMS) 2750G and National Fire Protection Association (NFPA) standards 70, 79, and 86D.
The furnace chamber shall feature double-walled, water-cooled 304 stainless steel construction with an all-metal insulated hot zone and all-metallic shield pack. The usable work zone minimum dimensions are 12" (W) x 12" (H) x 18" (D) with a hearth capacity rated for a minimum of 250 pounds. Performance requirements include a maximum operating temperature of 2400°F (1315°C), maximum cleanup cycle temperature of 2500°F (1371°C), temperature uniformity of ±10°F at 1000°F, 1500°F, and 2100°F, ultimate vacuum in the 10⁻⁶ Torr range, operating vacuum in the 10⁻⁵ Torr range, and leak-up rate less than 5 microns per hour. The furnace shall include a vacuum pumping system with a mechanical roughing pump (minimum 35 SCFM), high-vacuum diffusion pump (minimum 6"), and holding pump with full interlock for automatic fail-safe operation; an internal gas quenching/cooling system with minimum 7.5 HP motor designed for 2 bar (15 PSIG) positive pressure using Nitrogen or Argon; a partial pressure system for Nitrogen and Argon gas processes; and a self-contained, closed-loop water cooling system with pump station (minimum 40 GPM capacity), power-loss diaphragm backup pump, and minimum two dry coolers with 460V controls. Control systems shall include an Allen-Bradley or equivalent Programmable Logic Controller (PLC), Human Machine Interface (HMI) touchscreen display, data logging capability to verify temperature uniformity, and SCR-controlled hot zone power supply rated for minimum 65 KVA. The contractor shall provide a manual load truck, operator and maintenance training at no additional charge covering all furnace systems, and digital documentation including operation and maintenance manuals, component-specific manufacturer's manuals, mechanical and electrical drawings, and recommended spare parts list.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought Vacuum Relief Furnace.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Specifications Sheet:
Vacuum Relief Furnace General Requirements
• Furnace Type: Horizontal Front-Loading, Internal Gas Quench Vacuum Furnace.
• Condition: All components and materials used in the furnace must be brand-new.
• Compliance: The furnace system must conform to SAE Aerospace Material
Specification (AMS) 2750G and National Fire Protection Association (NFPA) standards 70, 79, and 86D.
Technical Specifications
Chamber and Hot Zone
• Chamber: Double-walled, water-cooled, 304 stainless steel construction.
• Hot Zone: All-Metal insulated hot zone, to include an all-metallic shield pack.
• Usable Work Zone (minimum): 12" (W) x 12" (H) x 18" (D).
• Hearth Capacity: Minimum rated weight capacity of 250 pounds.
Performance
• Maximum Operating Temperature: 2400∘F (1315∘C).
• Maximum Cleanup Cycle Temperature: 2500∘F (1371∘C).
• Temperature Uniformity: ±10∘F at 1000∘F, 1500∘F, and 2100∘F.
• Ultimate Vacuum: Must achieve a vacuum level in the 10−6 Torr range (clean, dry, empty).
• Operating Vacuum: Must operate in the 10−5 Torr range.
• Leak-Up Rate: Less than 5 microns per hour.
Subsystems
• Vacuum Pumping System: vacuum system including a mechanical roughing pump
(min. 35 SCFM), a high-vacuum diffusion pump (min. 6"), and a holding pump. The system must be fully interlocked for automatic, fail-safe operation.
DRAFT
• Gas Quenching/Cooling System: Internal gas cooling system with a minimum 7.5 HP motor, designed for 2 bar (15 PSIG) positive pressure cooling using Nitrogen or Argon.
• Partial Pressure System: Must include a system for running processes under partial pressure of Nitrogen and Argon gas.
• Closed-Loop Water System: A self-contained, closed-loop water cooling system is required. The system must include a pump station with a minimum 40 GPM capacity, a power-loss diaphragm backup pump, and minimum two (2) dry coolers (fans) with 460V controls.
Control and Power Systems
• Controller: Allen-Bradley (or equivalent) Programmable Logic Controller (PLC).
• Interface: Human Machine Interface (HMI) touchscreen display is required.
• Control & Data Logging: System must provide data to verify temperature uniformity across furnace
• Power Supply: SCR-controlled hot zone power supply rated for a minimum of 65
KVA.
Required Accessories
• Manual Load Truck: A manual load truck designed for loading and unloading the furnace is required.
Training
• Operator and Maintenance Training: The contractor shall provide training for maintenance and operation before final commissioning. This training will cover the operation and preventive maintenance of all furnace systems and must be provided at no additional charge.
Documentation
• Digital copies of Operation and Maintenance Manuals, component-specific
Manufacturer's Manuals, mechanical and electrical drawings, and a recommended spare parts list must be provided.
DRAFT
| Technical Specifications Sheet: Vacuum Relief Furnace |
| General Requirements |
| Technical Specifications |
| Chamber and Hot Zone |
| Performance |
| Subsystems |
| Control and Power Systems |
| Required Accessories |
| Training |
| Documentation |