Attachment 1-Technical Capability Statement 26QE046.docx

DOCX document 23 KB Posted

Attached to
Emerson by Flexim Transmitter, Transducer, Mounting Frame
Solicitation number
N4215826QE046
Issued by

About this file

This is a Technical Capability Statement that serves as a certification document for vendors responding to a Request for Quote (RFQ) issued by Norfolk Naval Shipyard in Portsmouth, Virginia for Emerson by Flexim brand equipment.

The procurement (RFQ #N4215826QE046) is a 100% Small Business set-aside solicitation for three line items totaling six units of specialized ultrasonic flow measurement equipment. CLIN 0001 requires two Emerson by Flexim Meter Transmitters for liquid measurement with dual measuring channels, 3% accuracy, operating instructions, carrying case, pipe mounting fixture, power supply units (-100 to 230V AC, 50/60 Hz), data transmission kit, measuring tape, and output adapter (P/N DE6-F601GP-NNNNN-2PG3-NN.CS2). CLIN 0002 requires two clamp-on transducers (TRD-FSQ-NNNN-NNNL-003 CDQ1NZ7) with shear wave frequency capability, calibration at six measuring points with factory calibration certificate, and coupling foils and compound for liquid measurement. CLIN 0003 requires two mounting frames with fastening shoes and rails for transducers at 4 MHz frequency in a diagonal measurement arrangement (P/N MOU-FSQ-DS-C0250). All quotes must include shipping with all costs incorporated into the bid; no additional costs can be added after award. Vendors must complete and sign Attachment 1 certifying that their products meet or exceed all specifications with no exceptions. Quotes are due by May 7, 2026, at 10:00 AM EST, submitted to john.e.faircloth2.civ@us.navy.mil. Award will be accompanied by an electronic copy and Certificate of Compliance to the winning vendor.

View the file

Other files

File Type Posted
Request for Quote Solicitation - N4215826QE046.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment (1) – Solicitation# N4215826QE046

EMERSON BY FLEXIM ITEMS 0001-0003

Vendor shall certify that item quoted meets the capabilities, features and specifications listed below and that vendor can assume all contractor responsibilities stated below by initialing at the bottom. In order to be considered for award, this must be completed and submitted with the vendor quote.

TECHNICAL CAPABILITES STATEMENT

General Specifications for CLIN/ITEM 0001 through 0003

Shall be provided with the following capabilities, features and specifications:
Yes
No

Please check yes or no next to each listing/description.

CLIN 0001 Quantity: 2 each

EMERSON BY FLEXIM

METER

TRANSMITTER

FOR THE MEASUREMENT OF: LIQUIDS

GENERAL PURPOSE

NO EXPLOSION PROTECTION

NON-INTRINSICALLY SAFE

NO ADDITIONAL CERTIFICATE

MEASURING CHANNELS: 2

3% ACCURACY OF MEASURED FLOWRATE

PROVIDED WITH TRANSMITTER:

OPERATING INSTRUCTIONS, ENGLISH,

CARRYING CASE

PIPE MOUNTING FIXTURE

POWER SUPPLY UNITS -100 TO 230 V AC, 50/60 HZ,

POWER CABLE

MAINS CABLE FOR CHARGING AND POWER SUPPLY UNIT (FOR USA)

DATA TRANSMISSION KIT

MEASURING TAPE - 9 FT,

OUTPUT ADAPTER WITH SIGNAL CABLE, 2 CURRENT OUTPUTS

P/N DE6-F601GP-NNNNN-2PG3-NN.CS2

CERTIFICATE OF COMPLIANCE CLAUSE INVOKED

CLIN 0002 Quantity: 2 each

EMERSON BY FLEXIM

TRANSDUCER

CLAMP-ON TRANSDUCER

TRD-FSQ-NNNN-NNNL-003

CDQ1NZ7

TRANSDUCER CALIBRATION WITH APERTURE CALIBRATION

6 MEASURING POINTS, INCLUDING CALIBRATION

CERTIFICATE (FACTORY CALIBRATION, NO ACCREDITED REPORT)

FOR THE MEASUREMENT OF: LIQUIDS

TYP: SHEAR WAVE

TRANSDUCER FREQUENCY

WITH COUPLING FOILS AND COUPLING COMPOUND.

CERTIFICATE OF COMPLIANCE CLAUSE INVOKED

CLIN 0003 Quantity: 2 each

EMERSON BY FLEXIM

MOUNTING FRAME

FASTENING SHOES

INCLUDING RAIL

FOR TRANSDUCER FREQUENCY Q – 4 MHZ

MEASUREMENT ARRANGEMENT: DIAGONAL

P/N MOU-FSQ-DS-C0250

CERTIFICATE OF COMPLIANCE CLAUSE INVOKED

TECHNICAL CAPABILITY/CONTRACTOR RESPONSIBILITY CERTIFICATION

Vendor hereby certifies that vendor’s item meets or exceeds all specifications and contractor responsibilities stated in this solicitation, in their entirety, with no exceptions. _________(Initials Vendor Representative )

DATE: _________________________________________

File details come from the government source that posted it. Updated .