This document contains a sources sought notice from the National Aeronautics and Space Administration Kennedy Space Center for a Sonic Systems, Inc. Ultrasonic Cleaning Tank System. The notice seeks capability statements from interested parties for a brand specific ultrasonic cleaning tank system manufactured by Sonic Systems, Inc. Responses are due by July 1, 2021 at 1:00 PM EST and should include the respondent's DUNS, CAGE code, and SAM expiration date. The notice indicates the requirement will be considered under set aside categories including small business, small disadvantaged business, 8(a), woman-owned small business, veteran-owned small business, and service-disabled veteran-owned small business. The NAICS code is 334419 for other electronic component manufacturing with a size standard of 750 employees. The notice specifies this is for information and planning purposes only and does not constitute a solicitation or commitment by the government.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sonic Systems, Inc. Ultrasonic Cleaning Tank Requirements

• Design

- Based on existing Sys “A” (original drawing and manufacture prior to electronic record keeping by MFG)

- Ultrasonic Console System

- Single tank, continuous use

- Required for aqueous solution degreasing

• Material of Construction

- Frame – 304 or 316 Stainless Steel

- Tank – 12 ga (min), 316L Stainless Steel

- Top – 12 ga (min), 316L Stainless Steel

- Doors & Panels – 16 ga (min), 316 Stainless Steel

- Lid – 16 ga, 304 Stainless Steel

• Console

- 316L Stainless Steel counter top, 14 ga (min)

- 304 or 316L Stainless Steel side panels and doors

- Approximate overall dimensions; 113” X 54” X 48” high

- Leveling pads, adjustable (3”)

- Lid – 16 ga, 304 Stainless Steel

• Tank

- ID; 65” X 36” X 36” deep o Processing solution volume ~290 gallons

- Radius internal corners

- Overflow weir, 20” height from bottom of work rack

- Support rail for hanging supplied cradles

- Sloping bottom for drain o 2” ball valve at low point drain

- Recessed skimmer spillway on one side at liquid level

- Sump with sludge removal drain o 1” NPT with SS ball valve

- Twelve (12) ¾” female quick disconnects (QDs), 6 per long side, in free-board area.

o Common manifold o Dedicated pump discharges tank solution through any QD (1-12) o Filtered to 10 microns absolute

- Twelve (12) ¼” quick disconnects (QDs), on one short side, in free-board zone o Common manifold o Facility supplied 100 psig gaseous nitrogen

- Low liquid level sensor

- High liquid level sensor

- Hydro-air spray wand o Separate pump

- Stainless steel immersion heater o 4” flang o 316 Stainless Steel o 36 kW o Thermostatically controlled

- Pump & Filtration o 10 HP Stainless Steel Pump o Stainless Steel bag filter type housing o Cartridge filter housing on pump discharge, 10 micron

• Ultrasonic Transducers

- Submersible type o 316L stainless steel, 14 ga o Approximate dimensions, 16” X 15” X 3” o Eight (8) units

- Internally, piezoelectric transducers, vacuum brazed (100% nickel). Note; no epoxy bonded units.

- Combined output – 9600 watts

- Bulkhead mounted at tank bottom

• Ultrasonic Generators

- Remote, solid state

- Rack mounted

- Eight (8) o Frequency 27 kHz +/- 2 kHz random sweep o Variable output o Operating in four (4) independent zones

• Generator Rack Enclosure

- Houses Generators in two enclosures

- Houses Transformer and associated electronics

- Located remote from unit

- ~ 25’ of interconnecting cable

- NEMA-12

• Controls

- Manual push button and switches for system functions

- Manual and automatic valves where applicable

- Digital thermostats

- Digital timers

- System readout via HMI

• System Requirements

- 480VAC, 3 phase, 60 Hz, 90 Amps