This document is a Statement of Work (SOW) for the procurement of two Coriolis flow meters by the Air Force Institute of Technology (AFIT). The first meter must have a 1/12 inch sensor size, 0.0005 g/cm3 density measurement accuracy, 316L stainless steel material, #8 VCO 316/316L Swagelok compatible fitting, 4-wire electronic interface, and 0.05% mass flow and 0.0002 g/cc density calibration. The second meter must have a 1/6 inch sensor size and match the other technical requirements. The meters must be compatible with AFIT's existing Micro Motion 2700 Multiple Variable Flow Transmitter. Delivery is required no later than September 30, 2024, to the AFIT facility at Wright-Patterson AFB, Ohio. The procurement is being conducted via Solicitation FA8601-24-Q-0090 as a commercial item acquisition under FAR Parts 12 and 13. Award will be made to the lowest-priced, technically acceptable offer.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

FOR

MICRO MOTION ELITE FLOW METER

2 Apr 2024

I. BACKGROUND: The Air Force Institute of Technology requires two Coriolis Flow Meters. These meters will be used to measure flow rates of lubricants and fuel.

II. MINIMUM TECHNICAL REQUIREMENTS:

The Coriolis Meters shall meet the following characteristics:

The FIRST Coriolis meter shall meet the following minimum capabilities:

1. Sensor Size: 1/12 inch

2. Density measurement accuracy to +/- 0.0005 g/cm3

3. Material: 316L stainless steel

4. Process Connection: #8 VCO 316/316L Swagelok compatible fitting 1/2in 316 NPT female adapter.

5. Electronic Interface: 4-Wire (For remote mount transmitters)

6. Calibration Options: 0.05% mass flow & 0.0002 g/cc density calibration

7. Compatible with existing Micro Motion 2700 Multiple Variable Flow Transmitter

The SECOND Coriolis meter shall meet the following minimum capabilities:

1. Sensor Size: 1/6 inch

2. Density measurement accuracy to +/- 0.0005 g/cm3

3. Material: 316L stainless steel

4. Process Connection: #8 VCO 316/316L Swagelok compatible fitting 1/2in 316 NPT female adapter.

5. Electronic Interface: 4-Wire (For remote mount transmitters)

6. Calibration Options: 0.05% mass flow & 0.0002 g/cc density calibration

7. Compatible with existing Micro Motion 2700 Multiple Variable Flow Transmitter

III. QUALIFYING COUNTRY PRODUCTS: All products proposed/delivered to satisfy these requirements shall be either domestic or qualifying country end products in accordance with DFARS 252.225-7001. Buy American and Balance of Payments Program.

IV. DELIVERY: The contractor shall deliver a complete system to the following address:

SHIP TO DODAAC: F4F5AV

POC: JAMIE SMITH

Air Force Institute of Technology/ENY 2950 Hobson Way

WPAFB, OH 45433

Phone number 937-656-6096

Email address JAMIE.SMITH.1@US.AF.MIL ranell.easterday@us.af.mil

V. LEAD TIME: The contractor shall deliver a complete system no later than 30 Sept 2024.

VI. DELIVERY PROCEDURES COMMERCIAL VEHICLES: All vehicles larger than a large pick‐up truck is required to be inspected by the Wright‐ Patterson Air Force Base Commercial Vehicle Delivery Gate (CVDG) prior to entering the installation.

1. Vehicles to be inspected include, but are not limited to, the following:

1.1 Step van/panel truck

1.2 Tractor/trailer, box, and flatbed containing cargo

1.3 Tanker trucks

1.4 Box Trucks

1.5 Tour buses

1.6 Garbage/recycled waste trucks

1.7 Concrete trucks/mixers, dump trucks

1.8 Cranes, recreational vehicles, petroleum tanker

2 This inspection will be conducted at Gate 16A located off State Route 444. The following are exceptions to vehicles utilizing the CVDG:

2.1 If the vehicle has the product inside (concrete and asphalt trucks) and timely delivery is necessary due to product deterioration it does not need to enter the

CVDG. To bypass the CVDG, the contractor shall submit a list containing drivers’ names, social security numbers and the state in which the driver's license is held for those drivers who will be entering the base. This shall be accomplished 24 hours prior to requested entry time. If entry is requested on Monday, this list must be submitted by Friday at 1630 hours. All lists shall be submitted to the 88th ABW/CE Directorate contract inspector. The only gates that may be used under this exemption shall be 15A, 26A, 38A, and gate 1B.

If the driver's name is not on the list, he/she will not be allowed access to the installation through these gates and the base will not assume liability for denied access.

2.2 If a delivery vehicle must exit, and then re‐enter the base to complete its route, the vehicle shall be resealed upon exiting the base. After initially passing through the commercial vehicle delivery gate, trucks shall be resealed at Gates 15A, 38A and 22B. The resealing of the trucks will allow them to continue to any other area of the installation (Areas A, B, or Kittyhawk) without reprocessing through the CVDG. To receive resealing assistance, the drivers shall physically stop at one of the three authorized gates and request the installation entry controller to reseal their truck and provide the next location of their delivery. The controller will reseal the truck and give the delivery driver a pre‐clearance form. The driver shall present the pre‐clearance form to the entry controller at the next point of installation entry. This reentry can be at any base gate.

2.3 Wright Patterson Integrated Defense Plan, paragraph 3.10.12.9.2. All irregular deliveries will be sent to the CVDG for inspection. All visitors, which include contractors and commercial vendors without proper background checks and contractor passes, will not be allowed on WPAFB unless escorted by the receiving agency. This will take place after the individual(s) are issued a pre‐ clearance form at the CVDG. After successful completion of the vehicle inspection, the receiving agency will escort the individual to and from their destination on WPAFB. An inspector at the CVDG will contact the receiving.

agency, informing them to send an escort to the CVDG. Escorts will remain with the vehicle at all times while it is on WPAFB.

3 Vehicles may be subject to an inspection at any of installation entry control points during a directed random antiterrorism measure (RAM). Any commercial vehicle, regardless of size, can be directed to the CVDG at the discretion of the installation entry controller.

VII. PAYMENT: 100% payment upon completion of all requirements specified in this Statement of

Work. Payment shall be made on a net 30 basis. Invoices shall be submitted and paid through Wide Area Work Flow (https://wawf.eb.mil).

https://wawf.eb.mil/

II. MINIMUM TECHNICAL REQUIREMENTS:
IV. DELIVERY: The contractor shall deliver a complete system to the following address:
SHIP TO DODAAC: F4F5AV
POC: JAMIE SMITH
Air Force Institute of Technology/ENY
2950 Hobson Way
WPAFB, OH 45433
Phone number 937-656-6096
Email address JAMIE.SMITH.1@US.AF.MIL
ranell.easterday@us.af.mil

File details come from the government source that posted it. Updated .