Attachment 1-Specifications .pdf

PDF 286 KB Posted

Attached to
Laser-Powered Electric Field Probe
Solicitation number
NB6750302502548
Issued by

About this file

This is a Requirements/Specification Document from the National Institute of Standards and Technology (NIST) for an E-Field Probe, issued by the Communications Technology Laboratory's Radio Frequency Technology Division, Electromagnetic Fields Group. The document details procurement requirements for two primary items: (1) an E-field Probe and (2) an E Field Probe Control Module. The E-field Probe specifications include a frequency range of 20 MHz – 60 GHz, laser-powered operation with maximum 0.5 W laser power, field strength measurement range of 2-1000 V/m, and three independent dipoles with a total probe and handle length ≤ 30 cm. The Control Module requires optical ST/FC connection, desktop form factor, USB/RS232 communication interfaces, and operates on 12 VDC. Delivery is specified for NIST-Boulder at 325 Broadway, with a 14-week delivery timeline after receipt of order. The equipment comes with a 3-year manufacturer's warranty covering labor and parts, and acceptance is not expected to exceed 7 business days.

View the file

Other files

File Type Posted
RFQ-NB6750302502548.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Requirements / Specification Document

TITLE: E-Field Probe

Requesting Laboratory / Division / Group:

Communications Technology Laboratory Radio Frequency Technology Division Electromagnetic Fields Group (672.02)

General Statement of Need:

The Electromagnetic Fields Group requires a laser-powered, three-axis RF electric field probe to cover 20 MHz – 60 GHz for calibrations of electromagnetic fields.

Item Specifications and Quantities:

Item 1: E-field Probe Quantity: 1 EACH Specifications: 1.1 Frequency Range 20 MHz – 60 GHz

1.2 Frequency Response (Flatness) +/- 1 dB

1.3 Anisotropy <= +/- 4 dB (40 – 60 GHz)

1.4 Laser-powered, maximum laser power 0.5 W

1.5 Field Strength measurement range 2 – 1000 V/m

1.6 Measurement volume 1 cm^3

1.7 3 dipoles with independent read-out

1.8 Operating temperature 0 – 40 degrees C

1.9 Relative humidity operating range 10 – 90 %

1.10 Total length of probe and handle <= 30 cm

1.11 Damage threshold 2 kV/m

1.12 Optical fiber length = 10 m

Item 2: E Field Probe Control Module

Quantity: 1 Specifications: 2.1 Optical ST/FC connection to laser powered probe

2.2 Desktop form factor

2.3 Size limited to 50 mm x 180 mm x 254 mm (HxWxD)

2.4 Weight <= 1.4 kg

2.5 Operating Temperature 10 – 40 degrees C

2.6 Supply voltage 12 VDC

2.7 Communication interface: USB, RS232

Procurement Support Information and Ancillary Services:

Section Requirements/Specifications

Planning Considerations

☒ N/A

☐ List any visits required to allow potential vendors to see site specific constraints.

[Explain Requirements.]

☐ US citizen required on-site (foreign nationals require pre-registration 30 days prior to visit.)

☐ Vendor Representative On-Site more than three (3) days.

☐ Other Considerations:

[List other considerations to ensure an accurate quote.]

Shipping & Delivery

☐ N/A

Shipping Address:

☒ NIST-Boulder Mail Stop: 672.02 325 Broadway Boulder, CO 80305

☐ NIST-Gaithersburg

ATTN:

Mail Stop:

100 Bureau Dr Gaithersburg MD 20899

☐ [Alternate Shipping Address]

Shipping Criteria:

☐ Partial Delivery Acceptable

☐ [Enter Shipping and Delivery information by item.]

☐ Direct Delivery to OU Building Required

[Explain Need for Requirement] Building /Room Number: [Enter Building/Room Number]

☐ Building has Loading Dock Containerization Preference: [Enter Container Type]

Other Requirements:

[List Any Other Requirement] Delivery Date Criteria:

☐ Delivery Shall Be Competed No Later Than:

Click or tap to enter a date.

☐ Delivery Shall Be Made No Earlier Than:

Click or tap to enter a date.

☐ Scheduled Deliveries:

Item Number Due Date

☒ Other:

14 weeks ARO

Electronic Media

☒ N/A [Enter Electronic Media Requirements by Item.]

☐ Software

☐ Electronic Manuals

☐ License Key

☐ Other:

[List Any Other Electronic Media Requirements]

☐ US Government Email Address for Software Delivery:

[Enter Address]

Installation

☒ N/A

[Enter Installation Requirements by Item]

☐ Vendor Technician on Site

☐ Rigging

☐ Uncrating / Unpackaging

☐ Removal of Packaging Material

☐ Equipment Set Up

☐ Start-Up Services

☐ Turnkey Installation

☐ Other:

NOTE: SME shall be the coordination POC.

Facility / Utility Considerations

☒ N/A

[List Site Specific Utility Considerations by Item]

☐ OFPM Work Order Numbers

[List Work Order Numbers]

☐ Power Available

Voltage: [Enter voltage] (V)

Maximum Current:

[Enter max current draw] (A)

Phase: [Choose Phase]

Frequency: [Typically 60Hz] (Hz)

NEMA Plug Type: [Enter Plug Type] (i.e.: NEMA L5-20P)

Environment: [Choose Environment]

Other Power Considerations:

[List Any Other Power Considerations.]

☐ Utility Connections:

[List Relevant Available Utilities, Pressure(s) and Flowrate(s).]

☐ Other Considerations:

[List Other Considerations to Ensure an Accurate Quote.]

Inspection and Acceptance

☐ N/A

[Inspection Requirements Per Item (Who, When, What, Where)]

☐ On-Site

☒ Acceptance Not Expected to Exceed 7 Business Days

☐ Acceptance Expected to Exceed 7 Business Days:

[Duration]

☐ Inspection and Acceptance Plan:

[Explanation]

[Enter Other Requirements]

Training

Training Requirements (Who, When, What, Where)

☐ Number of Trainees: [Enter Number of Trainees]

☐ On-Site

☐ Off-Site Location: [Enter Location(s)]

Is Trainee Travel Required: [Choose Answer]

Scope of Training ☐ Operation ☐ Maintenance ☐ Troubleshooting

☐ Safety ☐ Other

[Enter Other Scope of Training Requirements] ☐ Training Materials to be Provided by Government:

[Describe Materials]

☐ Training Materials to be Provided by Vendor:

[Describe Materials]

☐ Other

NOTE: SME shall be coordination POC.

Warranty

☐ N/A

Base Manufacturer Warranty is acceptable

Warranty Length: 3 Years

What is included?

☒ Labor ☒ Parts ☐ Travel

☐ Cost and Liability for Returns

☐ Other [Enter Other Requirements]

☐ 1 Option Period

☐ 2 Option Periods

☐ 3 Option Periods

☐ 4 Option Periods (Maximum)

Calibration

[Describe Calibration Requirements Per Item] Calibration Plan Length: [i.e. 3 - Years] What is Included?

☐ Labor ☐ Spare Parts ☐ Consumables

☐ Travel ☐ Cost and Liability for Shipment

☐ Software Updates ☐ Manuals

☐ Other

[Enter Other Requirements] ☐ Requirements:

[Enter Requirements] (i.e.: On-Site Within 72 hours, etc.)

☐ 1 Option Period Length: [i.e. 1 – Year / 6 - Months]

☐ 2 Option Periods

Maintenance

[Describe Maintenance Requirements Per Item] Maintenance Plan Length: [i.e. 3 - Years] What is Included?

☐ Labor ☐ Spare Parts ☐ Consumables

☐ Travel ☐ Cost and Liability for Shipment

☐ Software Updates ☐ Manuals

☐ Other

[Enter Other Requirements] ☐ Requirements:

[Enter Requirements] (i.e.: On-Site Within 72 hours, etc.)

☐ 1 Option Period Length: [i.e. 1 – Year / 6 - Months]

☐ 2 Option Periods

Government Furnished Material / Equipment

☒ N/A

List Any Government Furnished Material / Equipment Per Item]

☐ Samples for Testing

☐ Equipment which will leave Government Site

Description:

Serial Number:

NIST Property Number:

[Enter Description] [Enter Serial Number] [Enter NIST Property Number]

☐ Other: [Enter Other Details]

Travel

[Describe any Travel Requirements Per Item]

☐ Explain:

[Enter Justification / Requirement]

[Enter Other Requirements]

NOTE TO VENDOR: To the maximum extent possible, include travel requirement estimates as part of pertinent sections above (Installation, Maintenance, Repair, etc.). Otherwise, Travel will be a separate line item, reimbursable per the Federal Travel Regulation.