Attachment 1 - Specifications.pdf
PDF 177 KB Posted
- Solicitation number
- 12305B24Q0166
About this file
This document is a solicitation for the procurement of automated soil gas flux sampling chambers, multiplexers, and associated hardware. The government is seeking 24 chambers, 3 multiplexers, and related accessories. The chambers must meet specific technical requirements, including internal mixing fans, weight, volume, surface area, and power specifications. Delivery is required within 90 days of contract award to the USDA/ARS facility in Beltsville, Maryland. The solicitation includes a statement of the required items, delivery schedule, point of contact, and additional training requirements. The procurement will be conducted as a full and open competition using commercial item procedures under FAR Part 13, with a Lowest Price Technically Acceptable evaluation method. Offers are due by 2:00 PM EST on 9/06/2024 and must include a technical capability statement, firm fixed price quote, and other required documentation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 3 - CLIN Structure.xlsx | XLSX spreadsheet | |
| Attachement 2 - Contract Terms and Conditions.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATIONS
1.0 Specifications Description:
BRAND NAME OR EQUAL (EOSENSE Automated Soil Gas Flux Sampling Chambers, Multiplexers, and Associated Hardware
Quantity: 24 chambers, 3 multiplexers; 24 custom accessory kits for chambers, 3 accessory kits for multiplexers
Unit Type: Each
Minimum Requirements:
Soil gas flux measurement chambers and multiplexer
• Chambers must have internal chamber mixing fan
• Chambers must weigh 17 kg or less for ease of handing
• Chambers must have volume of 0.072 m3
• Chambers must have surface area of 0.21 m2
• Chambers must have diameter of 52 cm
• Chambers must be available in opaque option
• Must have option of adding 30 cm and 70 cm base extensions to chambers such that final chamber heights are 75 cm and 115 cm, respectively
• Operating voltage for both chambers and multiplexer must be 12-15 V DC
• Operating power when in motion must be < 17 W
• Weight of multiplexer must be less than 12 kg
Associate Hardware
• Custom accessory kits (tubing, cables, collars for chambers) must be compatible with chambers and multiplexers defined above
• Power cable, USB A-miniB data cable, Analyzer-to-Muliplexer tube pair, and analyzer fittings must be compatible with multiplexers defined above
2.0 Place of Delivery
USDA/ARS
ATTN: Gwen Bagley Building 001 10300 Baltimore Avenue Beltsville, Maryland. 20705
A delivery dock is available at this location.
3.0 Delivery Schedule
Item QTY Unit Place of Delivery Delivery Date
Chambers and custom accessory kits 24 Each See Section 2.0 90 Days After Award
Multiplexers and custom accessory kits 3 Each See Section 2.0 90 Days After Award
4.0 Delivery Point of Contact
Gwen Bagley, gwen.bagley@ncsu.edu, (301) 848-9656
5.0 Additional Requirements
Must offer 3-day on-site training consisting of field setups and hands on training.
mailto:gwen.bagley@ncsu.edu
Soil gas flux measurement chambers and multiplexer
File details come from the government source that posted it. Updated .