Attachment 1 is a specification sheet detailing requirements for three 20-yard roll-off environmental containers for Sheppard Air Force Base. The containers must meet specific technical specifications, including standard dimensions of 22 feet long by 3.5 feet high by 8 feet wide, a standard cable understructure, minimum 7-gauge floor, 10-gauge walls, specific rail and cross-member configurations, a sealed rear door, installed tarp system, and interior liner hooks. The containers must be capable of holding Petroleum Contaminated Waste (PCW), which is classified as non-hazardous and non-DoT regulated, for several months before disposal.

The solicitation (FA302025Q0014) is a 100% small business set-aside for a Firm Fixed Price contract, with a NAICS code of 336212 and a small business size standard of 1,000 employees. The solicitation will close at 2:00 PM CST on 21 May 2025, with all questions due by 2:00 PM CST on 16 May 2025. The contract will be awarded by the Department of the Air Force Air Education and Training Command, with the important caveat that funds are not currently available and no award will be made until funding is secured.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1 - Specification Sheet Environmental Roll-off Container

Three roll-off containers that meet or is "EQUAL" to the following parameters:

- Must be standard 20-yard roll-off containers (approximate dimensions: 22 feet long by 3.5 feet high by 8 feet wide).

- Must have a standard cable understructure

- At least a 7-gauge floor

- At least 10-gauge walls

- At least 6x2x3/16-inch main rail

- Cross-members on 18-inch centers,

- At least a 4x3x3/16-inch top rail

- Sealed rear door

- Installed tarp system

- Liner hooks on the interior

- Painted any standard color.

- Must be able to hold Petroleum Contaminated Waste (PCW) for several months before being hauled off for disposal.

o PCW is classified as a non-hazardous, non-DoT regulated waste based on analytical testing and Air Force Environmental Section's waste determination/classifications procedures.