Flex Tube Environmentally Friendly – Fire Retardant 8” (EF-FR 8”)
Medium weight co-extruded polyolefin elastomer hose with a rigid external polypropylene helix
• Environmentally friendly
• Low outgassing (Low VOC vs. standard PVC hose)
• Ultra smooth interior to maximize efficiency of airflow
• Highly flexible
• Tight bend radius without crimping
• Spiral co-extruded engineered construction
• Helix must protect against wear (abrasion resistance)
• Moisture resistant
• Chemical resistant
• Fire retardant (FR) (UL 94-V2 material compliance)
• Inside Diameter: 8”
• Approx. Weight: 1.5 lbs. /ft.
• Wall Thickness .035”
• CL Bend Radius: 9.75”
• Compression Ratio: 2:1
• Negative pressure: 12 in. / hg.
• Working Pressure: 8 PSI
• Temperature Range: -20F to 160F
• Color: Based on application. See JML
• Length: 24 feet
VENT DUCT MUST BE MARKED “EF – FR” AND SHALL BE PLACED EVERY FOOT (12").
FONT SIZE, LETTER STYLE AND INK COLOR NOT SPECIFIED, BUT MARKING SHALL BE
PERMANENT AND CLEARLY LEGIBLE.