Attachment 1 - SOW - Tritium Monitors.pdf

PDF 71 KB Posted

Attached to
Tritium Monitors Federal contract opportunity
Solicitation number
W911KF24Q0053
Issued by
Department of the Army Materiel Command Contracting Command Detroit Arsenal

About this file

This document is a Statement of Work (SOW) for a federal contract opportunity to provide Anniston Army Depot with eight (8) Tritium Monitors.

The key requirements are: 1) The monitors must have an alarm able to be set no higher than 2x10-5 microcuries/ml, 2) The monitors must have continuous monitoring capability, and 3) The monitors must not require an internet connection to function. The contractor shall not make any changes to the scope of work without written approval from the Contracting Officer. All provided monitors must have a standard 1-year manufacturer's warranty.

The related federal contract opportunity is solicitation W911KF24Q0053, issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal, to procure the Tritium Monitors in accordance with the provided Statement of Work.

View the file

Other files for this federal contract opportunity

Other files attached to Tritium Monitors, newest first.
File Type Posted
Conformed Solicitation.pdf PDF
Amendment 1 Released.pdf PDF
Attachment 1 - SOW Revised 5 Sep - Tritium Monitors.pdf PDF
Attachment 3 - Request for Technical Literature.pdf PDF
W911KF-24-Q-0053 Released.pdf PDF
Attachment 2 - Evidence of Authority.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tritium Monitors Statement of Work

1.0 OBJECTIVE: The government has a need to continuously monitor tritium gas under a fume hood.

2.0 SCOPE: Anniston Army Depot (ANAD) has relocated a radioactive work room that must have continuous monitoring for tritium in the storage room and in the fume hoods. There is a need for 8 tritium monitors.

3.0 REQUIREMENTS:

3.1. The monitor shall have an alarm able to be set no higher than 2x10-5 microcuries/ml.

3.2. The monitors shall have continuous monitoring capability.

3.3. The monitors shall not require internet connection to function.

4.0 The contractor shall not proceed with any verbal or written change(s) to the scope of work from sources other than the Contracting Officer, who will provide changes in writing.

5.0 Warranty: All provided monitors shall have a standard 1-year manufacturer’s warranty.

1.0 OBJECTIVE: The government has a need to continuously monitor tritium gas under a fume hood.