This document is a Request for Quotation (RFQ) for the supply and installation of a sunshade structure at Nellis Air Force Base in Nevada. The project consists of providing a 132ft x 44ft powder-coated steel sunshade structure with 3 fabric tops and 8 columns, rated for 115 MPH wind loads. The vendor will be responsible for delivering all materials, supplies, tools, equipment, and labor to install the sunshade. The anticipated contract type is Firm Fixed Price, with a required delivery within 60 days of award. This is a total small business set-aside solicitation with NAICS code 236220 and a size standard of $45 million. Quotes are due by September 13, 2024, and the government will award the contract to the lowest-priced, technically acceptable offer.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work – Sunshade Bldg 811
Nellis AFB | 6155 McGough Pkwy, Supply Bldg. 811 – This project consists of supplying and installing a second shade structure in the outdoor storage area.
Sunshade Specifications. Structure size 132Ft X 44Ft, entry height 14Ft, powder-coated finish steel structure with 3 each fabric tops and 8 columns. Footing type drilled pier, recessed base plate, anchor bolts. Roof shape oversized hips with custom join to minimize gaps between fabrics with “quick links”.
Rated for wind load 115MPH.
Installation. Location Nellis AFB, NV, BLDG 811, East-side Open Storage. Vendor to deliver all materials, supplies, tools, equipment, personnel to install, assemble, and prepare site for sunshades.
Contractor will prepare the site to install footings to support the sunshade structure; best layout to avoid underground conduits (utility, communications, drainage, water, electrical).
99LRS will provide access to restrooms at BLDG 811.
The shade structures design shall conform to the latest version of the International Building Codes (IBC), the American Institute of Steel Construction (AISC) Steel Construction Manual (14th Edition or newer), the American Concrete Institute’s Building Code Requirements for Structural Concrete (ACI 318-14 or newer), the National Electric Code (NEC), the AF Instructions (AFI), the Unified Facilities Criteria (UFCs), and the Nellis Installation Facility Standards (IFS).