This document is a Sources Sought announcement for a construction contract to correct HVAC deficiencies in Building 2 Laundry/Warehouse at the Vancouver VA Medical Center in Vancouver, WA. The Department of Veterans Affairs, VISN 20 is seeking contractors with NAICS code 238220 - Plumbing, Heating, and Air Conditioning to provide labor, materials, equipment, commissioning, and supervision to replace HVAC equipment and controls. The estimated magnitude of the project is between $5,000,000 and $10,000,000, with a period of performance of 120 calendar days. Small business contractors, including WOSB, 8(a), SDVOSB, and HUBZone firms, are highly encouraged to respond. Responses should include company information, capabilities, project experience, estimated timeline, product details, and past performance on similar projects. Responses are due by 4:00 pm PDT on September 22, 2024. The government will use the responses to shape the acquisition strategy before issuing a formal solicitation.

View the file

Other files

File Type Posted
36C26025Q0010_1.docx DOCX document
Attachment 2 - Sources Sought Questionnaire 648-20-117 Rev.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

648-20-117 Correct FCA HVAC Deficiencies Bldg 2 Laundry/Warehouse Vancouver, WA.

Scope of work

Refer to the drawings, contract documents and specifica�ons to upgrade HVAC infrastructure in Building 2 Laundry/Warehouse (Vancouver) to correct FCA HVAC deficiencies. Contractor shall completely prepare site for building opera�ons, including demoli�on and removal of exis�ng structures, and furnish labor and materials and perform work for Correct HVAC FCA Deficiencies as required by drawings and specifica�ons.

The execute work is, in such a manner as to interfere as litle as possible, with work being done by others. Keep roads clear of construc�on materials, debris, standing construc�on equipment, and vehicles always. Execute work to minimize interference with normal func�oning of Medical Center as a whole, including opera�ons of u�lity services, fire protec�on systems and any exis�ng equipment, and with work being done by others. The use of equipment and tools, that transmit vibra�ons, and noises through the building structure, are not permited in buildings that are occupied, during construc�on. To include, jointly by pa�ents or medical personnel, and Contractor's personnel, except as permited by the COR where required by limited working space.

Laundry and Warehouse Building(s) will be occupied during performance of work. The contractor shall take all measures, and provide all material necessary for protec�ng exis�ng equipment, and property in affected areas of construc�on against dust and debris. So that equipment, and affected areas to be used in the medical facility opera�ons, will not be hindered. Also, the contractor shall permit access to The Department of Veterans Affairs personnel, through other construc�on areas, which serve as routes of access to such affected areas and equipment. These routes whether access or egress, shall be isolated from the construc�on areas, by temporary par��ons and have walking surfaces, ligh�ng etc. to facilitate both pa�ent and staff access. Moreover, to also coordinate altera�on work in areas occupied by Department of Veterans Affairs, so that medical facility opera�ons will con�nue during the construc�on period.

Certain areas of Building No. 2 will be occupied by Medical Center personnel for various periods as listed below:

AREA PERIOD

LAUNDRY - MON – FRIDAY 0530 - 1630

WAREHOUSE - MON – SAT 0630 - 1600